Effects of Heart Rate on Myocardial Native T1 Value Acquired by 5s(3s)3s MOLLI Sequence

Quantitative evaluation of myocardial native T1 value by measuring modified Look-Locker inversion recovery (MOLLI) method is clinically useful and is used for follow-up of various myocardial diseases. The heart rate during the scan can vary even in the same subjects. Therefore, it is important to kn...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Japanese Journal of Radiological Technology 2021, Vol.77(2), pp.172-181
Hauptverfasser: Ando, Chisato, Yamamoto, Hiroshi, Shinoda, Naoki, Maeda, Hitoshi, Ozawa, Kazuo, Ohmori, Yuko, Yanagisawa, Fumi, Amano, Yasuo
Format: Artikel
Sprache:jpn
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 181
container_issue 2
container_start_page 172
container_title Japanese Journal of Radiological Technology
container_volume 77
creator Ando, Chisato
Yamamoto, Hiroshi
Shinoda, Naoki
Maeda, Hitoshi
Ozawa, Kazuo
Ohmori, Yuko
Yanagisawa, Fumi
Amano, Yasuo
description Quantitative evaluation of myocardial native T1 value by measuring modified Look-Locker inversion recovery (MOLLI) method is clinically useful and is used for follow-up of various myocardial diseases. The heart rate during the scan can vary even in the same subjects. Therefore, it is important to know the effects of the heart rate on the native T1 value of the myocardium. In this study, we evaluated the effect of the heart rate on the T1 value in the 5s (3s) 3s scheme, time control data collection period of the MOLLI method, using phantom experiments and experiments of healthy volunteers. The 5s (3s) 3s scheme of the MOLLI method is considered to have little dependence on the heart rate, but the T1 value still varied up to about 7% depending on the heart rate, and was underestimated up to 8% during low heart rate using phantom experiments.
doi_str_mv 10.6009/jjrt.2021_JSRT_77.2.172
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2495022850</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2495022850</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2330-7bb9d4564f6122d6f69aaaf9e2a685c050eb9f68d90d22e0e72a62e6f3c932d33</originalsourceid><addsrcrecordid>eNplkN9LwzAQx4MoOOb-BgO-6ENrfrRp8zjGdJPNwTb1MaTpRTvmuiWtsP_ezMkQfLmDu-_nDj4IXVMSC0Lk_WrlmpgRRtXTYr5UWRazmGbsDHVontMoyXN-jjqECxklnKSXqOd9VZCAhhFJOuhtaC2YxuPa4hFo1-C5bgDXGzzd10a7stJr_Kyb6gvwkuJXvW4B982urRyUuNjj1N9yf8c9ns4mkzFewK6FjYErdGH12kPvt3fRy8NwORhFk9njeNCfRIZxTqKsKGSZpCKxgjJWCiuk1tpKYFrkqSEpgUJakZeSlIwBgSwsGAjLjeSs5LyLbo53t64On32jVnXrNuGlYolMCWN5SkIqO6aMq713YNXWVZ_a7RUl6iBSHUSqvyIVU0FkIKdHcuUb_Q4nLpiqzBqO3E_6UP7xp5z50E7Bhn8DBk2Bhg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2495022850</pqid></control><display><type>article</type><title>Effects of Heart Rate on Myocardial Native T1 Value Acquired by 5s(3s)3s MOLLI Sequence</title><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><creator>Ando, Chisato ; Yamamoto, Hiroshi ; Shinoda, Naoki ; Maeda, Hitoshi ; Ozawa, Kazuo ; Ohmori, Yuko ; Yanagisawa, Fumi ; Amano, Yasuo</creator><creatorcontrib>Ando, Chisato ; Yamamoto, Hiroshi ; Shinoda, Naoki ; Maeda, Hitoshi ; Ozawa, Kazuo ; Ohmori, Yuko ; Yanagisawa, Fumi ; Amano, Yasuo</creatorcontrib><description>Quantitative evaluation of myocardial native T1 value by measuring modified Look-Locker inversion recovery (MOLLI) method is clinically useful and is used for follow-up of various myocardial diseases. The heart rate during the scan can vary even in the same subjects. Therefore, it is important to know the effects of the heart rate on the native T1 value of the myocardium. In this study, we evaluated the effect of the heart rate on the T1 value in the 5s (3s) 3s scheme, time control data collection period of the MOLLI method, using phantom experiments and experiments of healthy volunteers. The 5s (3s) 3s scheme of the MOLLI method is considered to have little dependence on the heart rate, but the T1 value still varied up to about 7% depending on the heart rate, and was underestimated up to 8% during low heart rate using phantom experiments.</description><identifier>ISSN: 0369-4305</identifier><identifier>EISSN: 1881-4883</identifier><identifier>DOI: 10.6009/jjrt.2021_JSRT_77.2.172</identifier><language>jpn</language><publisher>Kyoto: Japanese Society of Radiological Technology</publisher><subject>Control data (computers) ; Coronary artery disease ; Data collection ; Experiments ; Heart diseases ; Heart rate ; Inversion ; modified Look-Locker inversion recovery (MOLLI) method ; Myocardium ; native T1 value ; Recovery</subject><ispartof>Japanese Journal of Radiological Technology, 2021, Vol.77(2), pp.172-181</ispartof><rights>2021 Japanese Society of Radiological Technology</rights><rights>Copyright Japan Science and Technology Agency 2021</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c2330-7bb9d4564f6122d6f69aaaf9e2a685c050eb9f68d90d22e0e72a62e6f3c932d33</citedby><cites>FETCH-LOGICAL-c2330-7bb9d4564f6122d6f69aaaf9e2a685c050eb9f68d90d22e0e72a62e6f3c932d33</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,4010,27900,27901,27902</link.rule.ids></links><search><creatorcontrib>Ando, Chisato</creatorcontrib><creatorcontrib>Yamamoto, Hiroshi</creatorcontrib><creatorcontrib>Shinoda, Naoki</creatorcontrib><creatorcontrib>Maeda, Hitoshi</creatorcontrib><creatorcontrib>Ozawa, Kazuo</creatorcontrib><creatorcontrib>Ohmori, Yuko</creatorcontrib><creatorcontrib>Yanagisawa, Fumi</creatorcontrib><creatorcontrib>Amano, Yasuo</creatorcontrib><title>Effects of Heart Rate on Myocardial Native T1 Value Acquired by 5s(3s)3s MOLLI Sequence</title><title>Japanese Journal of Radiological Technology</title><addtitle>Jpn. J. Radiol. Technol.</addtitle><description>Quantitative evaluation of myocardial native T1 value by measuring modified Look-Locker inversion recovery (MOLLI) method is clinically useful and is used for follow-up of various myocardial diseases. The heart rate during the scan can vary even in the same subjects. Therefore, it is important to know the effects of the heart rate on the native T1 value of the myocardium. In this study, we evaluated the effect of the heart rate on the T1 value in the 5s (3s) 3s scheme, time control data collection period of the MOLLI method, using phantom experiments and experiments of healthy volunteers. The 5s (3s) 3s scheme of the MOLLI method is considered to have little dependence on the heart rate, but the T1 value still varied up to about 7% depending on the heart rate, and was underestimated up to 8% during low heart rate using phantom experiments.</description><subject>Control data (computers)</subject><subject>Coronary artery disease</subject><subject>Data collection</subject><subject>Experiments</subject><subject>Heart diseases</subject><subject>Heart rate</subject><subject>Inversion</subject><subject>modified Look-Locker inversion recovery (MOLLI) method</subject><subject>Myocardium</subject><subject>native T1 value</subject><subject>Recovery</subject><issn>0369-4305</issn><issn>1881-4883</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><recordid>eNplkN9LwzAQx4MoOOb-BgO-6ENrfrRp8zjGdJPNwTb1MaTpRTvmuiWtsP_ezMkQfLmDu-_nDj4IXVMSC0Lk_WrlmpgRRtXTYr5UWRazmGbsDHVontMoyXN-jjqECxklnKSXqOd9VZCAhhFJOuhtaC2YxuPa4hFo1-C5bgDXGzzd10a7stJr_Kyb6gvwkuJXvW4B982urRyUuNjj1N9yf8c9ns4mkzFewK6FjYErdGH12kPvt3fRy8NwORhFk9njeNCfRIZxTqKsKGSZpCKxgjJWCiuk1tpKYFrkqSEpgUJakZeSlIwBgSwsGAjLjeSs5LyLbo53t64On32jVnXrNuGlYolMCWN5SkIqO6aMq713YNXWVZ_a7RUl6iBSHUSqvyIVU0FkIKdHcuUb_Q4nLpiqzBqO3E_6UP7xp5z50E7Bhn8DBk2Bhg</recordid><startdate>2021</startdate><enddate>2021</enddate><creator>Ando, Chisato</creator><creator>Yamamoto, Hiroshi</creator><creator>Shinoda, Naoki</creator><creator>Maeda, Hitoshi</creator><creator>Ozawa, Kazuo</creator><creator>Ohmori, Yuko</creator><creator>Yanagisawa, Fumi</creator><creator>Amano, Yasuo</creator><general>Japanese Society of Radiological Technology</general><general>Japan Science and Technology Agency</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7QO</scope><scope>7SC</scope><scope>7U5</scope><scope>8FD</scope><scope>FR3</scope><scope>JQ2</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope><scope>P64</scope></search><sort><creationdate>2021</creationdate><title>Effects of Heart Rate on Myocardial Native T1 Value Acquired by 5s(3s)3s MOLLI Sequence</title><author>Ando, Chisato ; Yamamoto, Hiroshi ; Shinoda, Naoki ; Maeda, Hitoshi ; Ozawa, Kazuo ; Ohmori, Yuko ; Yanagisawa, Fumi ; Amano, Yasuo</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2330-7bb9d4564f6122d6f69aaaf9e2a685c050eb9f68d90d22e0e72a62e6f3c932d33</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>jpn</language><creationdate>2021</creationdate><topic>Control data (computers)</topic><topic>Coronary artery disease</topic><topic>Data collection</topic><topic>Experiments</topic><topic>Heart diseases</topic><topic>Heart rate</topic><topic>Inversion</topic><topic>modified Look-Locker inversion recovery (MOLLI) method</topic><topic>Myocardium</topic><topic>native T1 value</topic><topic>Recovery</topic><toplevel>online_resources</toplevel><creatorcontrib>Ando, Chisato</creatorcontrib><creatorcontrib>Yamamoto, Hiroshi</creatorcontrib><creatorcontrib>Shinoda, Naoki</creatorcontrib><creatorcontrib>Maeda, Hitoshi</creatorcontrib><creatorcontrib>Ozawa, Kazuo</creatorcontrib><creatorcontrib>Ohmori, Yuko</creatorcontrib><creatorcontrib>Yanagisawa, Fumi</creatorcontrib><creatorcontrib>Amano, Yasuo</creatorcontrib><collection>CrossRef</collection><collection>Biotechnology Research Abstracts</collection><collection>Computer and Information Systems Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts – Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>Biotechnology and BioEngineering Abstracts</collection><jtitle>Japanese Journal of Radiological Technology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ando, Chisato</au><au>Yamamoto, Hiroshi</au><au>Shinoda, Naoki</au><au>Maeda, Hitoshi</au><au>Ozawa, Kazuo</au><au>Ohmori, Yuko</au><au>Yanagisawa, Fumi</au><au>Amano, Yasuo</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Effects of Heart Rate on Myocardial Native T1 Value Acquired by 5s(3s)3s MOLLI Sequence</atitle><jtitle>Japanese Journal of Radiological Technology</jtitle><addtitle>Jpn. J. Radiol. Technol.</addtitle><date>2021</date><risdate>2021</risdate><volume>77</volume><issue>2</issue><spage>172</spage><epage>181</epage><pages>172-181</pages><issn>0369-4305</issn><eissn>1881-4883</eissn><abstract>Quantitative evaluation of myocardial native T1 value by measuring modified Look-Locker inversion recovery (MOLLI) method is clinically useful and is used for follow-up of various myocardial diseases. The heart rate during the scan can vary even in the same subjects. Therefore, it is important to know the effects of the heart rate on the native T1 value of the myocardium. In this study, we evaluated the effect of the heart rate on the T1 value in the 5s (3s) 3s scheme, time control data collection period of the MOLLI method, using phantom experiments and experiments of healthy volunteers. The 5s (3s) 3s scheme of the MOLLI method is considered to have little dependence on the heart rate, but the T1 value still varied up to about 7% depending on the heart rate, and was underestimated up to 8% during low heart rate using phantom experiments.</abstract><cop>Kyoto</cop><pub>Japanese Society of Radiological Technology</pub><doi>10.6009/jjrt.2021_JSRT_77.2.172</doi><tpages>10</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0369-4305
ispartof Japanese Journal of Radiological Technology, 2021, Vol.77(2), pp.172-181
issn 0369-4305
1881-4883
language jpn
recordid cdi_proquest_journals_2495022850
source Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals
subjects Control data (computers)
Coronary artery disease
Data collection
Experiments
Heart diseases
Heart rate
Inversion
modified Look-Locker inversion recovery (MOLLI) method
Myocardium
native T1 value
Recovery
title Effects of Heart Rate on Myocardial Native T1 Value Acquired by 5s(3s)3s MOLLI Sequence
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-31T09%3A04%3A36IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Effects%20of%20Heart%20Rate%20on%20Myocardial%20Native%20T1%20Value%20Acquired%20by%205s(3s)3s%20MOLLI%20Sequence&rft.jtitle=Japanese%20Journal%20of%20Radiological%20Technology&rft.au=Ando,%20Chisato&rft.date=2021&rft.volume=77&rft.issue=2&rft.spage=172&rft.epage=181&rft.pages=172-181&rft.issn=0369-4305&rft.eissn=1881-4883&rft_id=info:doi/10.6009/jjrt.2021_JSRT_77.2.172&rft_dat=%3Cproquest_cross%3E2495022850%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2495022850&rft_id=info:pmid/&rfr_iscdi=true