Development of a Polydimethylsiloxane‐Based Electrode Array for Electrocorticography

Neural interfaces play an essential role to disclose neural networks and to assist paralyzed patients in past decades. As the conformability and longevity become vital issues for neural interfaces, flexible materials are increasingly engaged in the development of such devices. However, the developme...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Advanced materials interfaces 2020-12, Vol.7 (24), p.n/a
Hauptverfasser: Lee, Kyeong Yeon, Moon, Hyunmin, Kim, Boil, Kang, Yoo Na, Jang, Jae‐Won, Choe, Han Kyoung, Kim, Sohee
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page n/a
container_issue 24
container_start_page
container_title Advanced materials interfaces
container_volume 7
creator Lee, Kyeong Yeon
Moon, Hyunmin
Kim, Boil
Kang, Yoo Na
Jang, Jae‐Won
Choe, Han Kyoung
Kim, Sohee
description Neural interfaces play an essential role to disclose neural networks and to assist paralyzed patients in past decades. As the conformability and longevity become vital issues for neural interfaces, flexible materials are increasingly engaged in the development of such devices. However, the development of devices comprised of polydimethylsiloxane (PDMS) is bothered because of its incompatibility with silicon microfabrication technology, mainly caused by different thermal expansion coefficients between metals and PDMS. Here, a PDMS‐based electrode array is developed through a single‐wafer processing by employing an intermediate parylene‐C layer, which allows stable and simple fabrication as well as easy miniaturization and integration with other components. The developed electrode array can detect visual evoked potentials (VEPs) through in vivo experiments using mice. The conformal contact and high spatial resolution are achieved by detecting distinctive VEPs from all 16 channels. To investigate the effect of electrode sizes on signal quality, three different diameters ranging from 20 to 120 µm are used, resulting in no clear correlation between the electrode size and signal quality. The developed device suggests the potential of PDMS‐based bioelectronics in various applications where the flexibility and conformability as well as the robustness of the device are all desired. A polydimethylsiloxane (PDMS)‐based microelectrode array for electrocorticography is reported in this study. Employing a thin intermediate parylene‐C layer between PDMS and metals enables the miniaturization in feature size and easy integration with hard components through a single‐wafer processing. The fabricated device can effectively detect in vivo visual evoked potentials, with high conformability, spatial resolution, and signal quality.
doi_str_mv 10.1002/admi.202001152
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2470567587</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2470567587</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3172-ce4809cbafbdb46c8b74ac46c3c53af70847116be37dfbc43a32cc91872add033</originalsourceid><addsrcrecordid>eNqFkMtOwzAQRS0EElVhyzoS6xQ_kjhZlrZApSJYAFvLscc0lVMHOwWy4xP4Rr6EVOW1YzVXo3NnpIPQCcEjgjE9k7quRhRTjAlJ6R4aUFJkMWcp3v-TD9FxCCu8hSihORughyk8g3VNDes2ciaS0a2zna5qaJedDZV1r3INH2_v5zKAjmYWVOudhmjsvewi4_z3TjnfVso9etksuyN0YKQNcPw1h-j-YnY3uYoXN5fzyXgRK0Y4jRUkOS5UKU2pyyRTeckTqfrAVMqk4ThPOCFZCYxrU6qESUaVKkjOqdQaMzZEp7u7jXdPGwitWLmNX_cvBU04TjOe5rynRjtKeReCByMaX9XSd4JgsdUntvrEj76-UOwKL5WF7h9ajKfX89_uJyjUdhg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2470567587</pqid></control><display><type>article</type><title>Development of a Polydimethylsiloxane‐Based Electrode Array for Electrocorticography</title><source>Wiley Online Library Journals Frontfile Complete</source><creator>Lee, Kyeong Yeon ; Moon, Hyunmin ; Kim, Boil ; Kang, Yoo Na ; Jang, Jae‐Won ; Choe, Han Kyoung ; Kim, Sohee</creator><creatorcontrib>Lee, Kyeong Yeon ; Moon, Hyunmin ; Kim, Boil ; Kang, Yoo Na ; Jang, Jae‐Won ; Choe, Han Kyoung ; Kim, Sohee</creatorcontrib><description>Neural interfaces play an essential role to disclose neural networks and to assist paralyzed patients in past decades. As the conformability and longevity become vital issues for neural interfaces, flexible materials are increasingly engaged in the development of such devices. However, the development of devices comprised of polydimethylsiloxane (PDMS) is bothered because of its incompatibility with silicon microfabrication technology, mainly caused by different thermal expansion coefficients between metals and PDMS. Here, a PDMS‐based electrode array is developed through a single‐wafer processing by employing an intermediate parylene‐C layer, which allows stable and simple fabrication as well as easy miniaturization and integration with other components. The developed electrode array can detect visual evoked potentials (VEPs) through in vivo experiments using mice. The conformal contact and high spatial resolution are achieved by detecting distinctive VEPs from all 16 channels. To investigate the effect of electrode sizes on signal quality, three different diameters ranging from 20 to 120 µm are used, resulting in no clear correlation between the electrode size and signal quality. The developed device suggests the potential of PDMS‐based bioelectronics in various applications where the flexibility and conformability as well as the robustness of the device are all desired. A polydimethylsiloxane (PDMS)‐based microelectrode array for electrocorticography is reported in this study. Employing a thin intermediate parylene‐C layer between PDMS and metals enables the miniaturization in feature size and easy integration with hard components through a single‐wafer processing. The fabricated device can effectively detect in vivo visual evoked potentials, with high conformability, spatial resolution, and signal quality.</description><identifier>ISSN: 2196-7350</identifier><identifier>EISSN: 2196-7350</identifier><identifier>DOI: 10.1002/admi.202001152</identifier><language>eng</language><publisher>Weinheim: John Wiley &amp; Sons, Inc</publisher><subject>Arrays ; electrocorticography ; Electrodes ; Incompatibility ; Miniaturization ; neural interfaces ; Neural networks ; Polydimethylsiloxane ; Signal quality ; soft electronics ; Spatial resolution ; Thermal expansion</subject><ispartof>Advanced materials interfaces, 2020-12, Vol.7 (24), p.n/a</ispartof><rights>2020 Wiley‐VCH GmbH</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3172-ce4809cbafbdb46c8b74ac46c3c53af70847116be37dfbc43a32cc91872add033</citedby><cites>FETCH-LOGICAL-c3172-ce4809cbafbdb46c8b74ac46c3c53af70847116be37dfbc43a32cc91872add033</cites><orcidid>0000-0002-4372-4864 ; 0000-0002-0972-8677 ; 0000-0001-7849-7094 ; 0000-0002-4926-8978</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Fadmi.202001152$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Fadmi.202001152$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,776,780,1411,27903,27904,45553,45554</link.rule.ids></links><search><creatorcontrib>Lee, Kyeong Yeon</creatorcontrib><creatorcontrib>Moon, Hyunmin</creatorcontrib><creatorcontrib>Kim, Boil</creatorcontrib><creatorcontrib>Kang, Yoo Na</creatorcontrib><creatorcontrib>Jang, Jae‐Won</creatorcontrib><creatorcontrib>Choe, Han Kyoung</creatorcontrib><creatorcontrib>Kim, Sohee</creatorcontrib><title>Development of a Polydimethylsiloxane‐Based Electrode Array for Electrocorticography</title><title>Advanced materials interfaces</title><description>Neural interfaces play an essential role to disclose neural networks and to assist paralyzed patients in past decades. As the conformability and longevity become vital issues for neural interfaces, flexible materials are increasingly engaged in the development of such devices. However, the development of devices comprised of polydimethylsiloxane (PDMS) is bothered because of its incompatibility with silicon microfabrication technology, mainly caused by different thermal expansion coefficients between metals and PDMS. Here, a PDMS‐based electrode array is developed through a single‐wafer processing by employing an intermediate parylene‐C layer, which allows stable and simple fabrication as well as easy miniaturization and integration with other components. The developed electrode array can detect visual evoked potentials (VEPs) through in vivo experiments using mice. The conformal contact and high spatial resolution are achieved by detecting distinctive VEPs from all 16 channels. To investigate the effect of electrode sizes on signal quality, three different diameters ranging from 20 to 120 µm are used, resulting in no clear correlation between the electrode size and signal quality. The developed device suggests the potential of PDMS‐based bioelectronics in various applications where the flexibility and conformability as well as the robustness of the device are all desired. A polydimethylsiloxane (PDMS)‐based microelectrode array for electrocorticography is reported in this study. Employing a thin intermediate parylene‐C layer between PDMS and metals enables the miniaturization in feature size and easy integration with hard components through a single‐wafer processing. The fabricated device can effectively detect in vivo visual evoked potentials, with high conformability, spatial resolution, and signal quality.</description><subject>Arrays</subject><subject>electrocorticography</subject><subject>Electrodes</subject><subject>Incompatibility</subject><subject>Miniaturization</subject><subject>neural interfaces</subject><subject>Neural networks</subject><subject>Polydimethylsiloxane</subject><subject>Signal quality</subject><subject>soft electronics</subject><subject>Spatial resolution</subject><subject>Thermal expansion</subject><issn>2196-7350</issn><issn>2196-7350</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNqFkMtOwzAQRS0EElVhyzoS6xQ_kjhZlrZApSJYAFvLscc0lVMHOwWy4xP4Rr6EVOW1YzVXo3NnpIPQCcEjgjE9k7quRhRTjAlJ6R4aUFJkMWcp3v-TD9FxCCu8hSihORughyk8g3VNDes2ciaS0a2zna5qaJedDZV1r3INH2_v5zKAjmYWVOudhmjsvewi4_z3TjnfVso9etksuyN0YKQNcPw1h-j-YnY3uYoXN5fzyXgRK0Y4jRUkOS5UKU2pyyRTeckTqfrAVMqk4ThPOCFZCYxrU6qESUaVKkjOqdQaMzZEp7u7jXdPGwitWLmNX_cvBU04TjOe5rynRjtKeReCByMaX9XSd4JgsdUntvrEj76-UOwKL5WF7h9ajKfX89_uJyjUdhg</recordid><startdate>20201201</startdate><enddate>20201201</enddate><creator>Lee, Kyeong Yeon</creator><creator>Moon, Hyunmin</creator><creator>Kim, Boil</creator><creator>Kang, Yoo Na</creator><creator>Jang, Jae‐Won</creator><creator>Choe, Han Kyoung</creator><creator>Kim, Sohee</creator><general>John Wiley &amp; Sons, Inc</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SR</scope><scope>7U5</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope><scope>L7M</scope><orcidid>https://orcid.org/0000-0002-4372-4864</orcidid><orcidid>https://orcid.org/0000-0002-0972-8677</orcidid><orcidid>https://orcid.org/0000-0001-7849-7094</orcidid><orcidid>https://orcid.org/0000-0002-4926-8978</orcidid></search><sort><creationdate>20201201</creationdate><title>Development of a Polydimethylsiloxane‐Based Electrode Array for Electrocorticography</title><author>Lee, Kyeong Yeon ; Moon, Hyunmin ; Kim, Boil ; Kang, Yoo Na ; Jang, Jae‐Won ; Choe, Han Kyoung ; Kim, Sohee</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3172-ce4809cbafbdb46c8b74ac46c3c53af70847116be37dfbc43a32cc91872add033</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Arrays</topic><topic>electrocorticography</topic><topic>Electrodes</topic><topic>Incompatibility</topic><topic>Miniaturization</topic><topic>neural interfaces</topic><topic>Neural networks</topic><topic>Polydimethylsiloxane</topic><topic>Signal quality</topic><topic>soft electronics</topic><topic>Spatial resolution</topic><topic>Thermal expansion</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Lee, Kyeong Yeon</creatorcontrib><creatorcontrib>Moon, Hyunmin</creatorcontrib><creatorcontrib>Kim, Boil</creatorcontrib><creatorcontrib>Kang, Yoo Na</creatorcontrib><creatorcontrib>Jang, Jae‐Won</creatorcontrib><creatorcontrib>Choe, Han Kyoung</creatorcontrib><creatorcontrib>Kim, Sohee</creatorcontrib><collection>CrossRef</collection><collection>Engineered Materials Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Advanced materials interfaces</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Lee, Kyeong Yeon</au><au>Moon, Hyunmin</au><au>Kim, Boil</au><au>Kang, Yoo Na</au><au>Jang, Jae‐Won</au><au>Choe, Han Kyoung</au><au>Kim, Sohee</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Development of a Polydimethylsiloxane‐Based Electrode Array for Electrocorticography</atitle><jtitle>Advanced materials interfaces</jtitle><date>2020-12-01</date><risdate>2020</risdate><volume>7</volume><issue>24</issue><epage>n/a</epage><issn>2196-7350</issn><eissn>2196-7350</eissn><abstract>Neural interfaces play an essential role to disclose neural networks and to assist paralyzed patients in past decades. As the conformability and longevity become vital issues for neural interfaces, flexible materials are increasingly engaged in the development of such devices. However, the development of devices comprised of polydimethylsiloxane (PDMS) is bothered because of its incompatibility with silicon microfabrication technology, mainly caused by different thermal expansion coefficients between metals and PDMS. Here, a PDMS‐based electrode array is developed through a single‐wafer processing by employing an intermediate parylene‐C layer, which allows stable and simple fabrication as well as easy miniaturization and integration with other components. The developed electrode array can detect visual evoked potentials (VEPs) through in vivo experiments using mice. The conformal contact and high spatial resolution are achieved by detecting distinctive VEPs from all 16 channels. To investigate the effect of electrode sizes on signal quality, three different diameters ranging from 20 to 120 µm are used, resulting in no clear correlation between the electrode size and signal quality. The developed device suggests the potential of PDMS‐based bioelectronics in various applications where the flexibility and conformability as well as the robustness of the device are all desired. A polydimethylsiloxane (PDMS)‐based microelectrode array for electrocorticography is reported in this study. Employing a thin intermediate parylene‐C layer between PDMS and metals enables the miniaturization in feature size and easy integration with hard components through a single‐wafer processing. The fabricated device can effectively detect in vivo visual evoked potentials, with high conformability, spatial resolution, and signal quality.</abstract><cop>Weinheim</cop><pub>John Wiley &amp; Sons, Inc</pub><doi>10.1002/admi.202001152</doi><tpages>10</tpages><orcidid>https://orcid.org/0000-0002-4372-4864</orcidid><orcidid>https://orcid.org/0000-0002-0972-8677</orcidid><orcidid>https://orcid.org/0000-0001-7849-7094</orcidid><orcidid>https://orcid.org/0000-0002-4926-8978</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 2196-7350
ispartof Advanced materials interfaces, 2020-12, Vol.7 (24), p.n/a
issn 2196-7350
2196-7350
language eng
recordid cdi_proquest_journals_2470567587
source Wiley Online Library Journals Frontfile Complete
subjects Arrays
electrocorticography
Electrodes
Incompatibility
Miniaturization
neural interfaces
Neural networks
Polydimethylsiloxane
Signal quality
soft electronics
Spatial resolution
Thermal expansion
title Development of a Polydimethylsiloxane‐Based Electrode Array for Electrocorticography
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-27T04%3A23%3A01IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Development%20of%20a%20Polydimethylsiloxane%E2%80%90Based%20Electrode%20Array%20for%20Electrocorticography&rft.jtitle=Advanced%20materials%20interfaces&rft.au=Lee,%20Kyeong%20Yeon&rft.date=2020-12-01&rft.volume=7&rft.issue=24&rft.epage=n/a&rft.issn=2196-7350&rft.eissn=2196-7350&rft_id=info:doi/10.1002/admi.202001152&rft_dat=%3Cproquest_cross%3E2470567587%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2470567587&rft_id=info:pmid/&rfr_iscdi=true