Electromagnetic Interference Caused by Parasitic Electric-line Current on a Digital Module in a Closed Cabinet

This paper conducts an electromagnetic analysis of the closed cabinet used for instrumentation and control in nuclear power plants for the case of a parasitic electric-line current that is undesirably generated onto an interior digital module. Based on the Helmholtz equation in conjunction with both...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE access 2019, Vol.7, p.59806-59812
Hauptverfasser: Choo, Jaeyul, Park, Jong-Eon, Choo, Hosung, Kim, Yong-Hwa
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This paper conducts an electromagnetic analysis of the closed cabinet used for instrumentation and control in nuclear power plants for the case of a parasitic electric-line current that is undesirably generated onto an interior digital module. Based on the Helmholtz equation in conjunction with both the separation of variables and superposition principle, we employed a mode-matching method to obtain the analytic solution to an electromagnetic interference problem. Using modal coefficients from a set of simultaneous equations by enforcing boundary conditions, we computationally derive electromagnetic-field distributions in terms of various geometric parameters. The results provide us with information useful for estimating the level of influence of the undesired current source on the adjacent digital modules.
ISSN:2169-3536
2169-3536
DOI:10.1109/ACCESS.2019.2914126