Exploration of Interventionists' Technical Manipulation Skills for Robot-Assisted Intravascular PCI Catheterization

Despite the great proven advantages of imaging techniques in percutaneous coronary interventions (PCIs), the recent rapid increase in the number of PCI procedures exposes both surgical experts and patients to more radiation and orthopedic hazards in the intervention room. While patients are minimall...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE access 2020, Vol.8, p.53750-53765
Hauptverfasser: Du, Wenjing, Omisore, Olatunji Mumini, Duan, Wenke, Zhou, Tao, Lv, Xiaodan, Li, Yifa, Han, Shipeng, Al-Handarish, Yousef, Liu, Qiuhua, Wang, Lei
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 53765
container_issue
container_start_page 53750
container_title IEEE access
container_volume 8
creator Du, Wenjing
Omisore, Olatunji Mumini
Duan, Wenke
Zhou, Tao
Lv, Xiaodan
Li, Yifa
Han, Shipeng
Al-Handarish, Yousef
Liu, Qiuhua
Wang, Lei
description Despite the great proven advantages of imaging techniques in percutaneous coronary interventions (PCIs), the recent rapid increase in the number of PCI procedures exposes both surgical experts and patients to more radiation and orthopedic hazards in the intervention room. While patients are minimally exposed, many appearance of interventionists subject them to frequent exposure of the operational hazards. Despite promoting the use of robot-assisted intravascular PCI in the Cath-Labs, cognitive and technical skills of interventionists' are yet to be explored towards reducing procedure time and minimal exposure of surgeon to operational hazards. In this study, a random forest classification framework is developed for proper identification of technical manipulation skills of surgeons along with underlying motion patterns of the flexible intravascular tools ( viz. guidewire and catheter) during PCI catheterization. For this purpose, analysis of interventionists' muscular activities and related hand motion were decoded from physiological signals recorded with sensors. Surface electromyography, electromagnetic, and tactile force signals were acquired concurrently from seven interventionists during specified guidewire movement viz. pull, push, rotate-pull (clockwise rotation with pull), rotate-push (counterclockwise rotation with push) , CR (clockwise rotation), and CCR (counterclockwise rotation). While relations were established between force and muscle activities in the surgeon groups using Spearman's Rank-Order statistical method, Wilcoxon test and Kruskal-Wallis one-way ANOVA test were employed to identify intra-group and inter-group differences. From the experimental results obtained, guidewire delivery patterns exhibit stable characteristics with overall classification accuracies of 94.11% based on nineteen features subset from muscle activities and hand motion, followed by 88.01% based on twelve features subset from muscle activities, 71.97% based on seven features subset from hand motion, 84.56% based on ten features subset from part muscle activities and hand motion. Thus, this study shows existence of significant correlation (p < 0.05) between force and muscle activity during intravascular catheterization for PCIs, while comparably high tactile force values were experience in vascular model with plaque or stenosis.
doi_str_mv 10.1109/ACCESS.2020.2980579
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2453664788</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>9035494</ieee_id><doaj_id>oai_doaj_org_article_1f7a27c1d5344f389eed8216158861df</doaj_id><sourcerecordid>2453664788</sourcerecordid><originalsourceid>FETCH-LOGICAL-c408t-608210a617ccd15bd0a51009014ba87ed059f57560d401a29726f56a05cab2283</originalsourceid><addsrcrecordid>eNpNkc1u1DAUhSNEpValT9BNJBasMlw7_l2OogFGKgJ12rV1x3aohxAPdqYqPD1OU1V4Y_vqfOdYPlV1TWBFCOiP667b7HYrChRWVCvgUr-pLigRuml5K97-dz6vrnI-QFmqjLi8qPLm6TjEhFOIYx37ejtOPj36cb6HPOUP9Z23D2OwONRfcQzH07Bodz_DMOS6j6m-jfs4NeucC-DdbJHwEbMt0lR_77Z1h9ODL77h7zP7rjrrccj-6mW_rO4_be66L83Nt8_bbn3TWAZqagQoSgAFkdY6wvcOkBMADYTtUUnvgOueSy7AMSBItaSi5wKBW9xTqtrLarv4uogHc0zhF6Y_JmIwz4OYfhhMU7CDN6SXSKUljreM9a3S3ruSLghXShDXF6_3i9cxxd8nnydziKc0lucbysrPCibVnNguKptizsn3r6kEzFyWWcoyc1nmpaxCXS9U8N6_EhpazjRr_wHSqJB7</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2453664788</pqid></control><display><type>article</type><title>Exploration of Interventionists' Technical Manipulation Skills for Robot-Assisted Intravascular PCI Catheterization</title><source>IEEE Open Access Journals</source><source>DOAJ Directory of Open Access Journals</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><creator>Du, Wenjing ; Omisore, Olatunji Mumini ; Duan, Wenke ; Zhou, Tao ; Lv, Xiaodan ; Li, Yifa ; Han, Shipeng ; Al-Handarish, Yousef ; Liu, Qiuhua ; Wang, Lei</creator><creatorcontrib>Du, Wenjing ; Omisore, Olatunji Mumini ; Duan, Wenke ; Zhou, Tao ; Lv, Xiaodan ; Li, Yifa ; Han, Shipeng ; Al-Handarish, Yousef ; Liu, Qiuhua ; Wang, Lei</creatorcontrib><description>Despite the great proven advantages of imaging techniques in percutaneous coronary interventions (PCIs), the recent rapid increase in the number of PCI procedures exposes both surgical experts and patients to more radiation and orthopedic hazards in the intervention room. While patients are minimally exposed, many appearance of interventionists subject them to frequent exposure of the operational hazards. Despite promoting the use of robot-assisted intravascular PCI in the Cath-Labs, cognitive and technical skills of interventionists' are yet to be explored towards reducing procedure time and minimal exposure of surgeon to operational hazards. In this study, a random forest classification framework is developed for proper identification of technical manipulation skills of surgeons along with underlying motion patterns of the flexible intravascular tools ( viz. guidewire and catheter) during PCI catheterization. For this purpose, analysis of interventionists' muscular activities and related hand motion were decoded from physiological signals recorded with sensors. Surface electromyography, electromagnetic, and tactile force signals were acquired concurrently from seven interventionists during specified guidewire movement viz. pull, push, rotate-pull (clockwise rotation with pull), rotate-push (counterclockwise rotation with push) , CR (clockwise rotation), and CCR (counterclockwise rotation). While relations were established between force and muscle activities in the surgeon groups using Spearman's Rank-Order statistical method, Wilcoxon test and Kruskal-Wallis one-way ANOVA test were employed to identify intra-group and inter-group differences. From the experimental results obtained, guidewire delivery patterns exhibit stable characteristics with overall classification accuracies of 94.11% based on nineteen features subset from muscle activities and hand motion, followed by 88.01% based on twelve features subset from muscle activities, 71.97% based on seven features subset from hand motion, 84.56% based on ten features subset from part muscle activities and hand motion. Thus, this study shows existence of significant correlation (p &lt; 0.05) between force and muscle activity during intravascular catheterization for PCIs, while comparably high tactile force values were experience in vascular model with plaque or stenosis.</description><identifier>ISSN: 2169-3536</identifier><identifier>EISSN: 2169-3536</identifier><identifier>DOI: 10.1109/ACCESS.2020.2980579</identifier><identifier>CODEN: IAECCG</identifier><language>eng</language><publisher>Piscataway: IEEE</publisher><subject>Catheterization ; Catheters ; Classification ; Correlation analysis ; Exposure ; Force ; Forest management ; Imaging techniques ; Intravascular surgery ; Intubation ; Kruskal-Wallis test ; Muscles ; Operational hazards ; Orthopedics ; percutaneous coronary intervention ; Radiation hazards ; recognition accuracy ; Robot kinematics ; Robot sensing systems ; robotic catheterization ; Robots ; Rotation ; Skills ; surface electromyography ; Surgeons ; Surgery</subject><ispartof>IEEE access, 2020, Vol.8, p.53750-53765</ispartof><rights>Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) 2020</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c408t-608210a617ccd15bd0a51009014ba87ed059f57560d401a29726f56a05cab2283</citedby><cites>FETCH-LOGICAL-c408t-608210a617ccd15bd0a51009014ba87ed059f57560d401a29726f56a05cab2283</cites><orcidid>0000-0002-9740-5471 ; 0000-0001-7509-7538 ; 0000-0003-1168-8683 ; 0000-0002-0571-3398 ; 0000-0002-2215-5922</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/9035494$$EHTML$$P50$$Gieee$$Hfree_for_read</linktohtml><link.rule.ids>314,780,784,864,2102,4024,27633,27923,27924,27925,54933</link.rule.ids></links><search><creatorcontrib>Du, Wenjing</creatorcontrib><creatorcontrib>Omisore, Olatunji Mumini</creatorcontrib><creatorcontrib>Duan, Wenke</creatorcontrib><creatorcontrib>Zhou, Tao</creatorcontrib><creatorcontrib>Lv, Xiaodan</creatorcontrib><creatorcontrib>Li, Yifa</creatorcontrib><creatorcontrib>Han, Shipeng</creatorcontrib><creatorcontrib>Al-Handarish, Yousef</creatorcontrib><creatorcontrib>Liu, Qiuhua</creatorcontrib><creatorcontrib>Wang, Lei</creatorcontrib><title>Exploration of Interventionists' Technical Manipulation Skills for Robot-Assisted Intravascular PCI Catheterization</title><title>IEEE access</title><addtitle>Access</addtitle><description>Despite the great proven advantages of imaging techniques in percutaneous coronary interventions (PCIs), the recent rapid increase in the number of PCI procedures exposes both surgical experts and patients to more radiation and orthopedic hazards in the intervention room. While patients are minimally exposed, many appearance of interventionists subject them to frequent exposure of the operational hazards. Despite promoting the use of robot-assisted intravascular PCI in the Cath-Labs, cognitive and technical skills of interventionists' are yet to be explored towards reducing procedure time and minimal exposure of surgeon to operational hazards. In this study, a random forest classification framework is developed for proper identification of technical manipulation skills of surgeons along with underlying motion patterns of the flexible intravascular tools ( viz. guidewire and catheter) during PCI catheterization. For this purpose, analysis of interventionists' muscular activities and related hand motion were decoded from physiological signals recorded with sensors. Surface electromyography, electromagnetic, and tactile force signals were acquired concurrently from seven interventionists during specified guidewire movement viz. pull, push, rotate-pull (clockwise rotation with pull), rotate-push (counterclockwise rotation with push) , CR (clockwise rotation), and CCR (counterclockwise rotation). While relations were established between force and muscle activities in the surgeon groups using Spearman's Rank-Order statistical method, Wilcoxon test and Kruskal-Wallis one-way ANOVA test were employed to identify intra-group and inter-group differences. From the experimental results obtained, guidewire delivery patterns exhibit stable characteristics with overall classification accuracies of 94.11% based on nineteen features subset from muscle activities and hand motion, followed by 88.01% based on twelve features subset from muscle activities, 71.97% based on seven features subset from hand motion, 84.56% based on ten features subset from part muscle activities and hand motion. Thus, this study shows existence of significant correlation (p &lt; 0.05) between force and muscle activity during intravascular catheterization for PCIs, while comparably high tactile force values were experience in vascular model with plaque or stenosis.</description><subject>Catheterization</subject><subject>Catheters</subject><subject>Classification</subject><subject>Correlation analysis</subject><subject>Exposure</subject><subject>Force</subject><subject>Forest management</subject><subject>Imaging techniques</subject><subject>Intravascular surgery</subject><subject>Intubation</subject><subject>Kruskal-Wallis test</subject><subject>Muscles</subject><subject>Operational hazards</subject><subject>Orthopedics</subject><subject>percutaneous coronary intervention</subject><subject>Radiation hazards</subject><subject>recognition accuracy</subject><subject>Robot kinematics</subject><subject>Robot sensing systems</subject><subject>robotic catheterization</subject><subject>Robots</subject><subject>Rotation</subject><subject>Skills</subject><subject>surface electromyography</subject><subject>Surgeons</subject><subject>Surgery</subject><issn>2169-3536</issn><issn>2169-3536</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><sourceid>ESBDL</sourceid><sourceid>RIE</sourceid><sourceid>DOA</sourceid><recordid>eNpNkc1u1DAUhSNEpValT9BNJBasMlw7_l2OogFGKgJ12rV1x3aohxAPdqYqPD1OU1V4Y_vqfOdYPlV1TWBFCOiP667b7HYrChRWVCvgUr-pLigRuml5K97-dz6vrnI-QFmqjLi8qPLm6TjEhFOIYx37ejtOPj36cb6HPOUP9Z23D2OwONRfcQzH07Bodz_DMOS6j6m-jfs4NeucC-DdbJHwEbMt0lR_77Z1h9ODL77h7zP7rjrrccj-6mW_rO4_be66L83Nt8_bbn3TWAZqagQoSgAFkdY6wvcOkBMADYTtUUnvgOueSy7AMSBItaSi5wKBW9xTqtrLarv4uogHc0zhF6Y_JmIwz4OYfhhMU7CDN6SXSKUljreM9a3S3ruSLghXShDXF6_3i9cxxd8nnydziKc0lucbysrPCibVnNguKptizsn3r6kEzFyWWcoyc1nmpaxCXS9U8N6_EhpazjRr_wHSqJB7</recordid><startdate>2020</startdate><enddate>2020</enddate><creator>Du, Wenjing</creator><creator>Omisore, Olatunji Mumini</creator><creator>Duan, Wenke</creator><creator>Zhou, Tao</creator><creator>Lv, Xiaodan</creator><creator>Li, Yifa</creator><creator>Han, Shipeng</creator><creator>Al-Handarish, Yousef</creator><creator>Liu, Qiuhua</creator><creator>Wang, Lei</creator><general>IEEE</general><general>The Institute of Electrical and Electronics Engineers, Inc. (IEEE)</general><scope>97E</scope><scope>ESBDL</scope><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SC</scope><scope>7SP</scope><scope>7SR</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope><scope>JQ2</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope><scope>DOA</scope><orcidid>https://orcid.org/0000-0002-9740-5471</orcidid><orcidid>https://orcid.org/0000-0001-7509-7538</orcidid><orcidid>https://orcid.org/0000-0003-1168-8683</orcidid><orcidid>https://orcid.org/0000-0002-0571-3398</orcidid><orcidid>https://orcid.org/0000-0002-2215-5922</orcidid></search><sort><creationdate>2020</creationdate><title>Exploration of Interventionists' Technical Manipulation Skills for Robot-Assisted Intravascular PCI Catheterization</title><author>Du, Wenjing ; Omisore, Olatunji Mumini ; Duan, Wenke ; Zhou, Tao ; Lv, Xiaodan ; Li, Yifa ; Han, Shipeng ; Al-Handarish, Yousef ; Liu, Qiuhua ; Wang, Lei</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c408t-608210a617ccd15bd0a51009014ba87ed059f57560d401a29726f56a05cab2283</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Catheterization</topic><topic>Catheters</topic><topic>Classification</topic><topic>Correlation analysis</topic><topic>Exposure</topic><topic>Force</topic><topic>Forest management</topic><topic>Imaging techniques</topic><topic>Intravascular surgery</topic><topic>Intubation</topic><topic>Kruskal-Wallis test</topic><topic>Muscles</topic><topic>Operational hazards</topic><topic>Orthopedics</topic><topic>percutaneous coronary intervention</topic><topic>Radiation hazards</topic><topic>recognition accuracy</topic><topic>Robot kinematics</topic><topic>Robot sensing systems</topic><topic>robotic catheterization</topic><topic>Robots</topic><topic>Rotation</topic><topic>Skills</topic><topic>surface electromyography</topic><topic>Surgeons</topic><topic>Surgery</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Du, Wenjing</creatorcontrib><creatorcontrib>Omisore, Olatunji Mumini</creatorcontrib><creatorcontrib>Duan, Wenke</creatorcontrib><creatorcontrib>Zhou, Tao</creatorcontrib><creatorcontrib>Lv, Xiaodan</creatorcontrib><creatorcontrib>Li, Yifa</creatorcontrib><creatorcontrib>Han, Shipeng</creatorcontrib><creatorcontrib>Al-Handarish, Yousef</creatorcontrib><creatorcontrib>Liu, Qiuhua</creatorcontrib><creatorcontrib>Wang, Lei</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 2005-present</collection><collection>IEEE Open Access Journals</collection><collection>IEEE All-Society Periodicals Package (ASPP) 1998-Present</collection><collection>IEEE Electronic Library (IEL)</collection><collection>CrossRef</collection><collection>Computer and Information Systems Abstracts</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts – Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>IEEE access</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Du, Wenjing</au><au>Omisore, Olatunji Mumini</au><au>Duan, Wenke</au><au>Zhou, Tao</au><au>Lv, Xiaodan</au><au>Li, Yifa</au><au>Han, Shipeng</au><au>Al-Handarish, Yousef</au><au>Liu, Qiuhua</au><au>Wang, Lei</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Exploration of Interventionists' Technical Manipulation Skills for Robot-Assisted Intravascular PCI Catheterization</atitle><jtitle>IEEE access</jtitle><stitle>Access</stitle><date>2020</date><risdate>2020</risdate><volume>8</volume><spage>53750</spage><epage>53765</epage><pages>53750-53765</pages><issn>2169-3536</issn><eissn>2169-3536</eissn><coden>IAECCG</coden><abstract>Despite the great proven advantages of imaging techniques in percutaneous coronary interventions (PCIs), the recent rapid increase in the number of PCI procedures exposes both surgical experts and patients to more radiation and orthopedic hazards in the intervention room. While patients are minimally exposed, many appearance of interventionists subject them to frequent exposure of the operational hazards. Despite promoting the use of robot-assisted intravascular PCI in the Cath-Labs, cognitive and technical skills of interventionists' are yet to be explored towards reducing procedure time and minimal exposure of surgeon to operational hazards. In this study, a random forest classification framework is developed for proper identification of technical manipulation skills of surgeons along with underlying motion patterns of the flexible intravascular tools ( viz. guidewire and catheter) during PCI catheterization. For this purpose, analysis of interventionists' muscular activities and related hand motion were decoded from physiological signals recorded with sensors. Surface electromyography, electromagnetic, and tactile force signals were acquired concurrently from seven interventionists during specified guidewire movement viz. pull, push, rotate-pull (clockwise rotation with pull), rotate-push (counterclockwise rotation with push) , CR (clockwise rotation), and CCR (counterclockwise rotation). While relations were established between force and muscle activities in the surgeon groups using Spearman's Rank-Order statistical method, Wilcoxon test and Kruskal-Wallis one-way ANOVA test were employed to identify intra-group and inter-group differences. From the experimental results obtained, guidewire delivery patterns exhibit stable characteristics with overall classification accuracies of 94.11% based on nineteen features subset from muscle activities and hand motion, followed by 88.01% based on twelve features subset from muscle activities, 71.97% based on seven features subset from hand motion, 84.56% based on ten features subset from part muscle activities and hand motion. Thus, this study shows existence of significant correlation (p &lt; 0.05) between force and muscle activity during intravascular catheterization for PCIs, while comparably high tactile force values were experience in vascular model with plaque or stenosis.</abstract><cop>Piscataway</cop><pub>IEEE</pub><doi>10.1109/ACCESS.2020.2980579</doi><tpages>16</tpages><orcidid>https://orcid.org/0000-0002-9740-5471</orcidid><orcidid>https://orcid.org/0000-0001-7509-7538</orcidid><orcidid>https://orcid.org/0000-0003-1168-8683</orcidid><orcidid>https://orcid.org/0000-0002-0571-3398</orcidid><orcidid>https://orcid.org/0000-0002-2215-5922</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2169-3536
ispartof IEEE access, 2020, Vol.8, p.53750-53765
issn 2169-3536
2169-3536
language eng
recordid cdi_proquest_journals_2453664788
source IEEE Open Access Journals; DOAJ Directory of Open Access Journals; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals
subjects Catheterization
Catheters
Classification
Correlation analysis
Exposure
Force
Forest management
Imaging techniques
Intravascular surgery
Intubation
Kruskal-Wallis test
Muscles
Operational hazards
Orthopedics
percutaneous coronary intervention
Radiation hazards
recognition accuracy
Robot kinematics
Robot sensing systems
robotic catheterization
Robots
Rotation
Skills
surface electromyography
Surgeons
Surgery
title Exploration of Interventionists' Technical Manipulation Skills for Robot-Assisted Intravascular PCI Catheterization
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T17%3A02%3A17IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Exploration%20of%20Interventionists'%20Technical%20Manipulation%20Skills%20for%20Robot-Assisted%20Intravascular%20PCI%20Catheterization&rft.jtitle=IEEE%20access&rft.au=Du,%20Wenjing&rft.date=2020&rft.volume=8&rft.spage=53750&rft.epage=53765&rft.pages=53750-53765&rft.issn=2169-3536&rft.eissn=2169-3536&rft.coden=IAECCG&rft_id=info:doi/10.1109/ACCESS.2020.2980579&rft_dat=%3Cproquest_cross%3E2453664788%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2453664788&rft_id=info:pmid/&rft_ieee_id=9035494&rft_doaj_id=oai_doaj_org_article_1f7a27c1d5344f389eed8216158861df&rfr_iscdi=true