Dynamic performance analysis of inverter-driven split air conditioner

Variable speed technology has a great potential for improving energy efficiency and performance of vapor compression refrigeration cycle. Therefore, the study of dynamic characteristics of the refrigeration cycle using this new technology becomes essential. This study experimentally investigates the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International journal of refrigeration 2020-10, Vol.118, p.443-452
Hauptverfasser: Elsayed, Amr Owes, Kayed, T.S.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 452
container_issue
container_start_page 443
container_title International journal of refrigeration
container_volume 118
creator Elsayed, Amr Owes
Kayed, T.S.
description Variable speed technology has a great potential for improving energy efficiency and performance of vapor compression refrigeration cycle. Therefore, the study of dynamic characteristics of the refrigeration cycle using this new technology becomes essential. This study experimentally investigates the dynamic behavior of a split R-410A air conditioner comprising variable speed compressor, variable speed condenser fan, three speed evaporator fan and electronic expansion valve. The characteristics of the conditioner have been presented during the startup and shutdown periods. Furthermore, the effect of changing evaporator fan speed during the running of the conditioner has been illustrated and discussed. The influence of evaporator and condenser inlet air temperatures on the power consumption and coefficient of performance of the conditioner has also been investigated. The experimental results show that increasing the condenser entering air temperature by 7 °C, the power consumption has been increased by 18% and the coefficient of performance decreased by 15%.
doi_str_mv 10.1016/j.ijrefrig.2020.05.014
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2450792973</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0140700720302140</els_id><sourcerecordid>2450792973</sourcerecordid><originalsourceid>FETCH-LOGICAL-c340t-6ed3b85c044a5a597db517e265134ee238846f143c258bc1f9b024139a90286f3</originalsourceid><addsrcrecordid>eNqFkEtLAzEUhYMoWKt_QQZcz3jzmmR2Sq0PKLjRdchk7kiGdlKTaaH_3pTq2tWByzmHez5CbilUFGh9P1R-iNhH_1UxYFCBrICKMzKjWjUlA03PySxfoFQA6pJcpTQAUAVSz8jy6TDajXfFFmMf4saODgs72vUh-VSEvvDjHuOEseyi3-NYpO3aT4X1sXBh7Pzkw4jxmlz0dp3w5lfn5PN5-bF4LVfvL2-Lx1XpuICprLHjrZYOhLDSykZ1raQKWS0pF4iMay3qngrumNSto33TAhOUN7YBpuuez8ndqXcbw_cO02SGsIv522SYkKAa1iieXfXJ5WJIKaMx2-g3Nh4MBXNEZgbzh8wckRmQJgPKwYdTEPOGvcdokvOYiXQ-optMF_x_FT9c_He0</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2450792973</pqid></control><display><type>article</type><title>Dynamic performance analysis of inverter-driven split air conditioner</title><source>Elsevier ScienceDirect Journals</source><creator>Elsayed, Amr Owes ; Kayed, T.S.</creator><creatorcontrib>Elsayed, Amr Owes ; Kayed, T.S.</creatorcontrib><description>Variable speed technology has a great potential for improving energy efficiency and performance of vapor compression refrigeration cycle. Therefore, the study of dynamic characteristics of the refrigeration cycle using this new technology becomes essential. This study experimentally investigates the dynamic behavior of a split R-410A air conditioner comprising variable speed compressor, variable speed condenser fan, three speed evaporator fan and electronic expansion valve. The characteristics of the conditioner have been presented during the startup and shutdown periods. Furthermore, the effect of changing evaporator fan speed during the running of the conditioner has been illustrated and discussed. The influence of evaporator and condenser inlet air temperatures on the power consumption and coefficient of performance of the conditioner has also been investigated. The experimental results show that increasing the condenser entering air temperature by 7 °C, the power consumption has been increased by 18% and the coefficient of performance decreased by 15%.</description><identifier>ISSN: 0140-7007</identifier><identifier>EISSN: 1879-2081</identifier><identifier>DOI: 10.1016/j.ijrefrig.2020.05.014</identifier><language>eng</language><publisher>Paris: Elsevier Ltd</publisher><subject>Air conditioners ; Air conditioning equipment ; Air temperature ; Caractéristiques dynamiques du conditionneur ; Compresseur et ventilateurs à vitesse variable ; Compressors ; Condensers ; Conditionneur d’air entraîné par un variateur de fréquence ; Dynamic characteristics ; Dynamic characteristics of conditioner ; Efficacité énergétique du conditionneur d’air ; Energy efficiency of air conditioner ; Evaporation ; Evaporators ; Gas expanders ; Inverter-driven air conditioner ; New technology ; Power consumption ; Refrigeration ; Shutdowns ; Vapor compression refrigeration ; Variable speed compressor and fans</subject><ispartof>International journal of refrigeration, 2020-10, Vol.118, p.443-452</ispartof><rights>2020 Elsevier Ltd and IIR</rights><rights>Copyright Elsevier Science Ltd. Oct 2020</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c340t-6ed3b85c044a5a597db517e265134ee238846f143c258bc1f9b024139a90286f3</citedby><cites>FETCH-LOGICAL-c340t-6ed3b85c044a5a597db517e265134ee238846f143c258bc1f9b024139a90286f3</cites><orcidid>0000-0001-6677-1551</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0140700720302140$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65534</link.rule.ids></links><search><creatorcontrib>Elsayed, Amr Owes</creatorcontrib><creatorcontrib>Kayed, T.S.</creatorcontrib><title>Dynamic performance analysis of inverter-driven split air conditioner</title><title>International journal of refrigeration</title><description>Variable speed technology has a great potential for improving energy efficiency and performance of vapor compression refrigeration cycle. Therefore, the study of dynamic characteristics of the refrigeration cycle using this new technology becomes essential. This study experimentally investigates the dynamic behavior of a split R-410A air conditioner comprising variable speed compressor, variable speed condenser fan, three speed evaporator fan and electronic expansion valve. The characteristics of the conditioner have been presented during the startup and shutdown periods. Furthermore, the effect of changing evaporator fan speed during the running of the conditioner has been illustrated and discussed. The influence of evaporator and condenser inlet air temperatures on the power consumption and coefficient of performance of the conditioner has also been investigated. The experimental results show that increasing the condenser entering air temperature by 7 °C, the power consumption has been increased by 18% and the coefficient of performance decreased by 15%.</description><subject>Air conditioners</subject><subject>Air conditioning equipment</subject><subject>Air temperature</subject><subject>Caractéristiques dynamiques du conditionneur</subject><subject>Compresseur et ventilateurs à vitesse variable</subject><subject>Compressors</subject><subject>Condensers</subject><subject>Conditionneur d’air entraîné par un variateur de fréquence</subject><subject>Dynamic characteristics</subject><subject>Dynamic characteristics of conditioner</subject><subject>Efficacité énergétique du conditionneur d’air</subject><subject>Energy efficiency of air conditioner</subject><subject>Evaporation</subject><subject>Evaporators</subject><subject>Gas expanders</subject><subject>Inverter-driven air conditioner</subject><subject>New technology</subject><subject>Power consumption</subject><subject>Refrigeration</subject><subject>Shutdowns</subject><subject>Vapor compression refrigeration</subject><subject>Variable speed compressor and fans</subject><issn>0140-7007</issn><issn>1879-2081</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNqFkEtLAzEUhYMoWKt_QQZcz3jzmmR2Sq0PKLjRdchk7kiGdlKTaaH_3pTq2tWByzmHez5CbilUFGh9P1R-iNhH_1UxYFCBrICKMzKjWjUlA03PySxfoFQA6pJcpTQAUAVSz8jy6TDajXfFFmMf4saODgs72vUh-VSEvvDjHuOEseyi3-NYpO3aT4X1sXBh7Pzkw4jxmlz0dp3w5lfn5PN5-bF4LVfvL2-Lx1XpuICprLHjrZYOhLDSykZ1raQKWS0pF4iMay3qngrumNSto33TAhOUN7YBpuuez8ndqXcbw_cO02SGsIv522SYkKAa1iieXfXJ5WJIKaMx2-g3Nh4MBXNEZgbzh8wckRmQJgPKwYdTEPOGvcdokvOYiXQ-optMF_x_FT9c_He0</recordid><startdate>202010</startdate><enddate>202010</enddate><creator>Elsayed, Amr Owes</creator><creator>Kayed, T.S.</creator><general>Elsevier Ltd</general><general>Elsevier Science Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7TB</scope><scope>8FD</scope><scope>FR3</scope><orcidid>https://orcid.org/0000-0001-6677-1551</orcidid></search><sort><creationdate>202010</creationdate><title>Dynamic performance analysis of inverter-driven split air conditioner</title><author>Elsayed, Amr Owes ; Kayed, T.S.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c340t-6ed3b85c044a5a597db517e265134ee238846f143c258bc1f9b024139a90286f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Air conditioners</topic><topic>Air conditioning equipment</topic><topic>Air temperature</topic><topic>Caractéristiques dynamiques du conditionneur</topic><topic>Compresseur et ventilateurs à vitesse variable</topic><topic>Compressors</topic><topic>Condensers</topic><topic>Conditionneur d’air entraîné par un variateur de fréquence</topic><topic>Dynamic characteristics</topic><topic>Dynamic characteristics of conditioner</topic><topic>Efficacité énergétique du conditionneur d’air</topic><topic>Energy efficiency of air conditioner</topic><topic>Evaporation</topic><topic>Evaporators</topic><topic>Gas expanders</topic><topic>Inverter-driven air conditioner</topic><topic>New technology</topic><topic>Power consumption</topic><topic>Refrigeration</topic><topic>Shutdowns</topic><topic>Vapor compression refrigeration</topic><topic>Variable speed compressor and fans</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Elsayed, Amr Owes</creatorcontrib><creatorcontrib>Kayed, T.S.</creatorcontrib><collection>CrossRef</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><jtitle>International journal of refrigeration</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Elsayed, Amr Owes</au><au>Kayed, T.S.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Dynamic performance analysis of inverter-driven split air conditioner</atitle><jtitle>International journal of refrigeration</jtitle><date>2020-10</date><risdate>2020</risdate><volume>118</volume><spage>443</spage><epage>452</epage><pages>443-452</pages><issn>0140-7007</issn><eissn>1879-2081</eissn><abstract>Variable speed technology has a great potential for improving energy efficiency and performance of vapor compression refrigeration cycle. Therefore, the study of dynamic characteristics of the refrigeration cycle using this new technology becomes essential. This study experimentally investigates the dynamic behavior of a split R-410A air conditioner comprising variable speed compressor, variable speed condenser fan, three speed evaporator fan and electronic expansion valve. The characteristics of the conditioner have been presented during the startup and shutdown periods. Furthermore, the effect of changing evaporator fan speed during the running of the conditioner has been illustrated and discussed. The influence of evaporator and condenser inlet air temperatures on the power consumption and coefficient of performance of the conditioner has also been investigated. The experimental results show that increasing the condenser entering air temperature by 7 °C, the power consumption has been increased by 18% and the coefficient of performance decreased by 15%.</abstract><cop>Paris</cop><pub>Elsevier Ltd</pub><doi>10.1016/j.ijrefrig.2020.05.014</doi><tpages>10</tpages><orcidid>https://orcid.org/0000-0001-6677-1551</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0140-7007
ispartof International journal of refrigeration, 2020-10, Vol.118, p.443-452
issn 0140-7007
1879-2081
language eng
recordid cdi_proquest_journals_2450792973
source Elsevier ScienceDirect Journals
subjects Air conditioners
Air conditioning equipment
Air temperature
Caractéristiques dynamiques du conditionneur
Compresseur et ventilateurs à vitesse variable
Compressors
Condensers
Conditionneur d’air entraîné par un variateur de fréquence
Dynamic characteristics
Dynamic characteristics of conditioner
Efficacité énergétique du conditionneur d’air
Energy efficiency of air conditioner
Evaporation
Evaporators
Gas expanders
Inverter-driven air conditioner
New technology
Power consumption
Refrigeration
Shutdowns
Vapor compression refrigeration
Variable speed compressor and fans
title Dynamic performance analysis of inverter-driven split air conditioner
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-21T22%3A14%3A45IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Dynamic%20performance%20analysis%20of%20inverter-driven%20split%20air%20conditioner&rft.jtitle=International%20journal%20of%20refrigeration&rft.au=Elsayed,%20Amr%20Owes&rft.date=2020-10&rft.volume=118&rft.spage=443&rft.epage=452&rft.pages=443-452&rft.issn=0140-7007&rft.eissn=1879-2081&rft_id=info:doi/10.1016/j.ijrefrig.2020.05.014&rft_dat=%3Cproquest_cross%3E2450792973%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2450792973&rft_id=info:pmid/&rft_els_id=S0140700720302140&rfr_iscdi=true