A cavity ion source for high-ionization efficiency neodymium isotope-ratio analyses in the geosciences

The principles governing ionization techniques used in thermal ionization mass spectrometers are relatively well understood and have remained largely unchanged for many decades. Though significant advances have been made in ion signal quantification for isotope ratio measurements, particularly for a...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of analytical atomic spectrometry 2020-10, Vol.35 (1), p.2337-235
Hauptverfasser: Reimink, Jesse R, Carlson, Richard W, Mock, Timothy D
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 235
container_issue 1
container_start_page 2337
container_title Journal of analytical atomic spectrometry
container_volume 35
creator Reimink, Jesse R
Carlson, Richard W
Mock, Timothy D
description The principles governing ionization techniques used in thermal ionization mass spectrometers are relatively well understood and have remained largely unchanged for many decades. Though significant advances have been made in ion signal quantification for isotope ratio measurements, particularly for analyses of small samples by using multiple detector systems and low-noise amplifiers, the fundamental approach to sample ionization has received little focus. Modern TIMS techniques attempting to achieve parts-per-million level isotope ratios precisions are realizing limits imposed by the physics of the ionization source. A type of high-ionization efficiency thermal source employed in nuclear physics communities for decades is the so-called cavity thermal ionization source. Here, we provide a proof-of-concept study that shows cavity sources may provide a path forward to achieve a new level of precision in isotope ratio measurements from solid samples. We document our new, simple, cavity ion source design, show preliminary results from Nd isotope measurements, and discuss these new data in the context of current precision limits imposed during traditional thermal ionization methods. We show that, within the limits of our testbed mass spectrometer, mass fractionation within the cavity ion source appears similar to that from filament ion sources. We also demonstrate that oxide- versus -metal ion production plays a significant role in cavity ionization processes for Nd. Cavity ion sources may provide a viable path forward to achieving isotope ratios precisions at the sub-ppm precision level. Precision in Nd isotope ratios measurements is dominated by the number of ions counted. We show that cavity ion sources can provide ion beams capable of producing much more precise Nd isotope data.
doi_str_mv 10.1039/d0ja00228c
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2449460410</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2449460410</sourcerecordid><originalsourceid>FETCH-LOGICAL-c281t-3af34143a6cbb7e5515d1c2703530a09721290fe1390b5d251e3ff5facba2ecd3</originalsourceid><addsrcrecordid>eNpFkE1LAzEQhoMoWKsX70LAmxCdfO12j6V-U_Ci5yWbnbQp7aYmu8L66922oqeBmWeGeR9CLjnccpDFXQ0rAyDExB6REZeZYlordUxGILKcFSrPT8lZSisAUFroEXFTas2Xb3vqQ0NT6KJF6kKkS79YsqHnv027G6Fz3npsbE8bDHW_8d2G-hTasEUWdww1jVn3CRP1DW2XSBcY0n4F0zk5cWad8OK3jsnH48P77JnN355eZtM5s2LCWyaNk4oraTJbVTlqzXXNrchBagkGilxwUYBDLguodC00R-mcdsZWRqCt5ZhcH-5uY_jsMLXlaog0_JVKoVShMlCDpzG5OVA2hpQiunIb_cbEvuRQ7jyW9_A63XucDfDVAY7J_nH_nuUPLnlwcA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2449460410</pqid></control><display><type>article</type><title>A cavity ion source for high-ionization efficiency neodymium isotope-ratio analyses in the geosciences</title><source>Royal Society Of Chemistry Journals 2008-</source><source>Alma/SFX Local Collection</source><creator>Reimink, Jesse R ; Carlson, Richard W ; Mock, Timothy D</creator><creatorcontrib>Reimink, Jesse R ; Carlson, Richard W ; Mock, Timothy D</creatorcontrib><description>The principles governing ionization techniques used in thermal ionization mass spectrometers are relatively well understood and have remained largely unchanged for many decades. Though significant advances have been made in ion signal quantification for isotope ratio measurements, particularly for analyses of small samples by using multiple detector systems and low-noise amplifiers, the fundamental approach to sample ionization has received little focus. Modern TIMS techniques attempting to achieve parts-per-million level isotope ratios precisions are realizing limits imposed by the physics of the ionization source. A type of high-ionization efficiency thermal source employed in nuclear physics communities for decades is the so-called cavity thermal ionization source. Here, we provide a proof-of-concept study that shows cavity sources may provide a path forward to achieve a new level of precision in isotope ratio measurements from solid samples. We document our new, simple, cavity ion source design, show preliminary results from Nd isotope measurements, and discuss these new data in the context of current precision limits imposed during traditional thermal ionization methods. We show that, within the limits of our testbed mass spectrometer, mass fractionation within the cavity ion source appears similar to that from filament ion sources. We also demonstrate that oxide- versus -metal ion production plays a significant role in cavity ionization processes for Nd. Cavity ion sources may provide a viable path forward to achieving isotope ratios precisions at the sub-ppm precision level. Precision in Nd isotope ratios measurements is dominated by the number of ions counted. We show that cavity ion sources can provide ion beams capable of producing much more precise Nd isotope data.</description><identifier>ISSN: 0267-9477</identifier><identifier>EISSN: 1364-5544</identifier><identifier>DOI: 10.1039/d0ja00228c</identifier><language>eng</language><publisher>London: Royal Society of Chemistry</publisher><subject>Fractionation ; Ion sources ; Ionization ; Ions ; Isotope ratios ; Mass spectrometers ; Neodymium isotopes ; Nuclear physics</subject><ispartof>Journal of analytical atomic spectrometry, 2020-10, Vol.35 (1), p.2337-235</ispartof><rights>Copyright Royal Society of Chemistry 2020</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c281t-3af34143a6cbb7e5515d1c2703530a09721290fe1390b5d251e3ff5facba2ecd3</citedby><cites>FETCH-LOGICAL-c281t-3af34143a6cbb7e5515d1c2703530a09721290fe1390b5d251e3ff5facba2ecd3</cites><orcidid>0000-0002-5522-9369</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids></links><search><creatorcontrib>Reimink, Jesse R</creatorcontrib><creatorcontrib>Carlson, Richard W</creatorcontrib><creatorcontrib>Mock, Timothy D</creatorcontrib><title>A cavity ion source for high-ionization efficiency neodymium isotope-ratio analyses in the geosciences</title><title>Journal of analytical atomic spectrometry</title><description>The principles governing ionization techniques used in thermal ionization mass spectrometers are relatively well understood and have remained largely unchanged for many decades. Though significant advances have been made in ion signal quantification for isotope ratio measurements, particularly for analyses of small samples by using multiple detector systems and low-noise amplifiers, the fundamental approach to sample ionization has received little focus. Modern TIMS techniques attempting to achieve parts-per-million level isotope ratios precisions are realizing limits imposed by the physics of the ionization source. A type of high-ionization efficiency thermal source employed in nuclear physics communities for decades is the so-called cavity thermal ionization source. Here, we provide a proof-of-concept study that shows cavity sources may provide a path forward to achieve a new level of precision in isotope ratio measurements from solid samples. We document our new, simple, cavity ion source design, show preliminary results from Nd isotope measurements, and discuss these new data in the context of current precision limits imposed during traditional thermal ionization methods. We show that, within the limits of our testbed mass spectrometer, mass fractionation within the cavity ion source appears similar to that from filament ion sources. We also demonstrate that oxide- versus -metal ion production plays a significant role in cavity ionization processes for Nd. Cavity ion sources may provide a viable path forward to achieving isotope ratios precisions at the sub-ppm precision level. Precision in Nd isotope ratios measurements is dominated by the number of ions counted. We show that cavity ion sources can provide ion beams capable of producing much more precise Nd isotope data.</description><subject>Fractionation</subject><subject>Ion sources</subject><subject>Ionization</subject><subject>Ions</subject><subject>Isotope ratios</subject><subject>Mass spectrometers</subject><subject>Neodymium isotopes</subject><subject>Nuclear physics</subject><issn>0267-9477</issn><issn>1364-5544</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNpFkE1LAzEQhoMoWKsX70LAmxCdfO12j6V-U_Ci5yWbnbQp7aYmu8L66922oqeBmWeGeR9CLjnccpDFXQ0rAyDExB6REZeZYlordUxGILKcFSrPT8lZSisAUFroEXFTas2Xb3vqQ0NT6KJF6kKkS79YsqHnv027G6Fz3npsbE8bDHW_8d2G-hTasEUWdww1jVn3CRP1DW2XSBcY0n4F0zk5cWad8OK3jsnH48P77JnN355eZtM5s2LCWyaNk4oraTJbVTlqzXXNrchBagkGilxwUYBDLguodC00R-mcdsZWRqCt5ZhcH-5uY_jsMLXlaog0_JVKoVShMlCDpzG5OVA2hpQiunIb_cbEvuRQ7jyW9_A63XucDfDVAY7J_nH_nuUPLnlwcA</recordid><startdate>20201009</startdate><enddate>20201009</enddate><creator>Reimink, Jesse R</creator><creator>Carlson, Richard W</creator><creator>Mock, Timothy D</creator><general>Royal Society of Chemistry</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SR</scope><scope>7U5</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope><scope>L7M</scope><orcidid>https://orcid.org/0000-0002-5522-9369</orcidid></search><sort><creationdate>20201009</creationdate><title>A cavity ion source for high-ionization efficiency neodymium isotope-ratio analyses in the geosciences</title><author>Reimink, Jesse R ; Carlson, Richard W ; Mock, Timothy D</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c281t-3af34143a6cbb7e5515d1c2703530a09721290fe1390b5d251e3ff5facba2ecd3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Fractionation</topic><topic>Ion sources</topic><topic>Ionization</topic><topic>Ions</topic><topic>Isotope ratios</topic><topic>Mass spectrometers</topic><topic>Neodymium isotopes</topic><topic>Nuclear physics</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Reimink, Jesse R</creatorcontrib><creatorcontrib>Carlson, Richard W</creatorcontrib><creatorcontrib>Mock, Timothy D</creatorcontrib><collection>CrossRef</collection><collection>Engineered Materials Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Journal of analytical atomic spectrometry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Reimink, Jesse R</au><au>Carlson, Richard W</au><au>Mock, Timothy D</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A cavity ion source for high-ionization efficiency neodymium isotope-ratio analyses in the geosciences</atitle><jtitle>Journal of analytical atomic spectrometry</jtitle><date>2020-10-09</date><risdate>2020</risdate><volume>35</volume><issue>1</issue><spage>2337</spage><epage>235</epage><pages>2337-235</pages><issn>0267-9477</issn><eissn>1364-5544</eissn><abstract>The principles governing ionization techniques used in thermal ionization mass spectrometers are relatively well understood and have remained largely unchanged for many decades. Though significant advances have been made in ion signal quantification for isotope ratio measurements, particularly for analyses of small samples by using multiple detector systems and low-noise amplifiers, the fundamental approach to sample ionization has received little focus. Modern TIMS techniques attempting to achieve parts-per-million level isotope ratios precisions are realizing limits imposed by the physics of the ionization source. A type of high-ionization efficiency thermal source employed in nuclear physics communities for decades is the so-called cavity thermal ionization source. Here, we provide a proof-of-concept study that shows cavity sources may provide a path forward to achieve a new level of precision in isotope ratio measurements from solid samples. We document our new, simple, cavity ion source design, show preliminary results from Nd isotope measurements, and discuss these new data in the context of current precision limits imposed during traditional thermal ionization methods. We show that, within the limits of our testbed mass spectrometer, mass fractionation within the cavity ion source appears similar to that from filament ion sources. We also demonstrate that oxide- versus -metal ion production plays a significant role in cavity ionization processes for Nd. Cavity ion sources may provide a viable path forward to achieving isotope ratios precisions at the sub-ppm precision level. Precision in Nd isotope ratios measurements is dominated by the number of ions counted. We show that cavity ion sources can provide ion beams capable of producing much more precise Nd isotope data.</abstract><cop>London</cop><pub>Royal Society of Chemistry</pub><doi>10.1039/d0ja00228c</doi><tpages>14</tpages><orcidid>https://orcid.org/0000-0002-5522-9369</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0267-9477
ispartof Journal of analytical atomic spectrometry, 2020-10, Vol.35 (1), p.2337-235
issn 0267-9477
1364-5544
language eng
recordid cdi_proquest_journals_2449460410
source Royal Society Of Chemistry Journals 2008-; Alma/SFX Local Collection
subjects Fractionation
Ion sources
Ionization
Ions
Isotope ratios
Mass spectrometers
Neodymium isotopes
Nuclear physics
title A cavity ion source for high-ionization efficiency neodymium isotope-ratio analyses in the geosciences
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-05T05%3A33%3A21IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20cavity%20ion%20source%20for%20high-ionization%20efficiency%20neodymium%20isotope-ratio%20analyses%20in%20the%20geosciences&rft.jtitle=Journal%20of%20analytical%20atomic%20spectrometry&rft.au=Reimink,%20Jesse%20R&rft.date=2020-10-09&rft.volume=35&rft.issue=1&rft.spage=2337&rft.epage=235&rft.pages=2337-235&rft.issn=0267-9477&rft.eissn=1364-5544&rft_id=info:doi/10.1039/d0ja00228c&rft_dat=%3Cproquest_cross%3E2449460410%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2449460410&rft_id=info:pmid/&rfr_iscdi=true