Performance ratings of concentric and lateral (taped, brazed and extruded) capillary tube suction line heat exchangers running with isobutane

•Comparative analysis of conventional and novel capillary tube-suction line heat exchanger (CTSLHX) designs.•Extruded and lateral brazed arrangements presented the highest effectiveness.•Performance of lateral taped design depends strongly on the tape tightness and assembling process.•Tube material...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied thermal engineering 2020-05, Vol.171, p.115079, Article 115079
Hauptverfasser: Boeng, Joel, Stahelin, Rodrigues, Gonçalves, Joaquim M., Hermes, Christian J.L.