Instant velocity and consistency of emitted cloud change by the different levels of canister filling with Metered Dose Inhalers (MDIs), but not with Soft Mist Inhalers (SMIs): a bench study
Background: Inhalation is the preferred route for respiratory drug delivery, but several factors contribute to the variability of the respirable dose fraction. Instant velocity and the dynamic characteristics of the droplet cloud represent crucial factors. Aim was to measure and compare the instant...
Gespeichert in:
Veröffentlicht in: | Multidisciplinary respiratory medicine 2017-12, Vol.12 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng ; ita |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | |
container_start_page | |
container_title | Multidisciplinary respiratory medicine |
container_volume | 12 |
creator | Dal Negro, Roberto W. Longo, Pietro Villanis Ziani, Orestepaolo Bonadiman, Luca Turco, Paola |
description | Background: Inhalation is the preferred route for respiratory drug delivery, but several factors contribute to the variability of the respirable dose fraction. Instant velocity and the dynamic characteristics of the droplet cloud represent crucial factors. Aim was to measure and compare the instant velocity and the consistency of emitted cloud from five different MDIs (A - Salbutamol sulphate 100mcg, GSK; B - Salbutamol sulphate 100mcg, Valeas; C - Salmeterol xinafoate/Fluticasone propionate 25/125mcg, GSK; D - Formoterol fumarate/Bechlomethasone propionate 6/100mcg, Chiesi; E - Formoterol fumarate/Fluticasone dipropionate 5/125mcg, Mundipharma) and one SMI (Tiotropium bromide 5mcg, Boehringer Ingelheim), at different distance from the nozzle and canister filling. Methods: Measurements were made at 90, 50, and 10% of canister filling, and at 5, 10, and 20 cm from the nozzle, for a total of 972 puffs. A high speed video photography protocol was adopted and high speed cameras (1.200 frames/ sec.) were used. Data were acquired by means of specialized softwares. Temperature, humidity, and vibrations occurrence were strictly controlled during measurements. Statistics: Anova and p < 0.05 were accepted as the minimum significance level. Results: MDIs generated different Instant velocities: MDI B generated the highest, while MDI A the lowest. As expected, velocity decreased in proportion to the distance from the nozzle. Except with MDI C, instant velocity decreased significantly over the first 50% of canister emptying, but dropped by >33% at 90% of emptying with all other MDIs (p < 0–037; p < 0.001; p < 0.005, and p < 0.001, respectively). Instant velocity was extremely lower (p < 0.001) and constant for all levels of canister filling (p = ns) with SMI. All MDIs had a very fast jet phase, ranging 0.01–0.03 s at 10 cm, and 0.03–0.05 s at 20 cm from the nozzle, without any significant difference from each other (p= ns). MDIs generated a cloud similarly tight (p = ns) at 10 and 20 cm from the nozzle, while it was extremely wider and constant with the SMI (p = 0–001). Also the cloud turbulence was minimized during the SMI emission. Discussion and Conclusions: MDIs are characterized by a substantial variability in both their instant velocity and consistency of the emitted cloud at different levels of canister filling. SMI generates a much slower soft mist cloud which is constantly homogeneous and independent of canister emptying. These peculiarities assessed at bench a |
doi_str_mv | 10.4081/mrm.2017.240 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2439665876</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2439665876</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1030-826ebeeaf0feebb1fb3c383443ed7610cb8c70e690e771dbb2c45ac79aae70583</originalsourceid><addsrcrecordid>eNpNkU1r3DAQhkVoIMs2t_6AgVxa2N1Ilj_k3sqmHwtZckgKuRlJHsUOXmkryQn-cflvldkcosNIDM88GngJ-cLoJqeCXR_8YZNRVm2ynJ6RRUbzel3WhfhEFkxkYn4_XpDLEJ5pOmXBeJEvyNvOhihthBccnO7jBNK2oJ0NfYho9QTOAB76GDG1Bzem2kn7hKAmiB1C2xuDHpNhwOQIM6-lnac9mH4YevsEr33sYI-plSw3LiDsbCcH9AG-7m924dsK1BjBunhC752JsE-OD9z9PnHfQYJKa3UQ4thOn8m5kUPAy_d7Sf7--vmw_bO-vfu92_64XWtGOV2LrESFKA01iEoxo7jmguc5x7YqGdVK6IpiWVOsKtYqlem8kLqqpcSKFoIvydXJe_Tu34ghNs9u9DZ92WQ5r8uyEFWZqNWJ0t6F4NE0R98fpJ8aRps5oyZl1MwZpSnK_wPr94dN</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2439665876</pqid></control><display><type>article</type><title>Instant velocity and consistency of emitted cloud change by the different levels of canister filling with Metered Dose Inhalers (MDIs), but not with Soft Mist Inhalers (SMIs): a bench study</title><source>DOAJ Directory of Open Access Journals</source><source>PubMed Central Open Access</source><source>Springer Nature OA Free Journals</source><source>EZB-FREE-00999 freely available EZB journals</source><source>PubMed Central</source><creator>Dal Negro, Roberto W. ; Longo, Pietro ; Villanis Ziani, Orestepaolo ; Bonadiman, Luca ; Turco, Paola</creator><creatorcontrib>Dal Negro, Roberto W. ; Longo, Pietro ; Villanis Ziani, Orestepaolo ; Bonadiman, Luca ; Turco, Paola</creatorcontrib><description><![CDATA[Background: Inhalation is the preferred route for respiratory drug delivery, but several factors contribute to the variability of the respirable dose fraction. Instant velocity and the dynamic characteristics of the droplet cloud represent crucial factors. Aim was to measure and compare the instant velocity and the consistency of emitted cloud from five different MDIs (A - Salbutamol sulphate 100mcg, GSK; B - Salbutamol sulphate 100mcg, Valeas; C - Salmeterol xinafoate/Fluticasone propionate 25/125mcg, GSK; D - Formoterol fumarate/Bechlomethasone propionate 6/100mcg, Chiesi; E - Formoterol fumarate/Fluticasone dipropionate 5/125mcg, Mundipharma) and one SMI (Tiotropium bromide 5mcg, Boehringer Ingelheim), at different distance from the nozzle and canister filling. Methods: Measurements were made at 90, 50, and 10% of canister filling, and at 5, 10, and 20 cm from the nozzle, for a total of 972 puffs. A high speed video photography protocol was adopted and high speed cameras (1.200 frames/ sec.) were used. Data were acquired by means of specialized softwares. Temperature, humidity, and vibrations occurrence were strictly controlled during measurements. Statistics: Anova and p < 0.05 were accepted as the minimum significance level. Results: MDIs generated different Instant velocities: MDI B generated the highest, while MDI A the lowest. As expected, velocity decreased in proportion to the distance from the nozzle. Except with MDI C, instant velocity decreased significantly over the first 50% of canister emptying, but dropped by >33% at 90% of emptying with all other MDIs (p < 0–037; p < 0.001; p < 0.005, and p < 0.001, respectively). Instant velocity was extremely lower (p < 0.001) and constant for all levels of canister filling (p = ns) with SMI. All MDIs had a very fast jet phase, ranging 0.01–0.03 s at 10 cm, and 0.03–0.05 s at 20 cm from the nozzle, without any significant difference from each other (p= ns). MDIs generated a cloud similarly tight (p = ns) at 10 and 20 cm from the nozzle, while it was extremely wider and constant with the SMI (p = 0–001). Also the cloud turbulence was minimized during the SMI emission. Discussion and Conclusions: MDIs are characterized by a substantial variability in both their instant velocity and consistency of the emitted cloud at different levels of canister filling. SMI generates a much slower soft mist cloud which is constantly homogeneous and independent of canister emptying. These peculiarities assessed at bench are suggesting a higher dose consistency and a much more effective therapeutic performance also in real life.]]></description><identifier>ISSN: 1828-695X</identifier><identifier>EISSN: 2049-6958</identifier><identifier>DOI: 10.4081/mrm.2017.240</identifier><language>eng ; ita</language><publisher>Pavia: PAGEPress Publications</publisher><subject>Inhalers ; Velocity</subject><ispartof>Multidisciplinary respiratory medicine, 2017-12, Vol.12</ispartof><rights>2017. This work is published under http://creativecommons.org/licenses/by-nc/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,860,27903,27904</link.rule.ids></links><search><creatorcontrib>Dal Negro, Roberto W.</creatorcontrib><creatorcontrib>Longo, Pietro</creatorcontrib><creatorcontrib>Villanis Ziani, Orestepaolo</creatorcontrib><creatorcontrib>Bonadiman, Luca</creatorcontrib><creatorcontrib>Turco, Paola</creatorcontrib><title>Instant velocity and consistency of emitted cloud change by the different levels of canister filling with Metered Dose Inhalers (MDIs), but not with Soft Mist Inhalers (SMIs): a bench study</title><title>Multidisciplinary respiratory medicine</title><description><![CDATA[Background: Inhalation is the preferred route for respiratory drug delivery, but several factors contribute to the variability of the respirable dose fraction. Instant velocity and the dynamic characteristics of the droplet cloud represent crucial factors. Aim was to measure and compare the instant velocity and the consistency of emitted cloud from five different MDIs (A - Salbutamol sulphate 100mcg, GSK; B - Salbutamol sulphate 100mcg, Valeas; C - Salmeterol xinafoate/Fluticasone propionate 25/125mcg, GSK; D - Formoterol fumarate/Bechlomethasone propionate 6/100mcg, Chiesi; E - Formoterol fumarate/Fluticasone dipropionate 5/125mcg, Mundipharma) and one SMI (Tiotropium bromide 5mcg, Boehringer Ingelheim), at different distance from the nozzle and canister filling. Methods: Measurements were made at 90, 50, and 10% of canister filling, and at 5, 10, and 20 cm from the nozzle, for a total of 972 puffs. A high speed video photography protocol was adopted and high speed cameras (1.200 frames/ sec.) were used. Data were acquired by means of specialized softwares. Temperature, humidity, and vibrations occurrence were strictly controlled during measurements. Statistics: Anova and p < 0.05 were accepted as the minimum significance level. Results: MDIs generated different Instant velocities: MDI B generated the highest, while MDI A the lowest. As expected, velocity decreased in proportion to the distance from the nozzle. Except with MDI C, instant velocity decreased significantly over the first 50% of canister emptying, but dropped by >33% at 90% of emptying with all other MDIs (p < 0–037; p < 0.001; p < 0.005, and p < 0.001, respectively). Instant velocity was extremely lower (p < 0.001) and constant for all levels of canister filling (p = ns) with SMI. All MDIs had a very fast jet phase, ranging 0.01–0.03 s at 10 cm, and 0.03–0.05 s at 20 cm from the nozzle, without any significant difference from each other (p= ns). MDIs generated a cloud similarly tight (p = ns) at 10 and 20 cm from the nozzle, while it was extremely wider and constant with the SMI (p = 0–001). Also the cloud turbulence was minimized during the SMI emission. Discussion and Conclusions: MDIs are characterized by a substantial variability in both their instant velocity and consistency of the emitted cloud at different levels of canister filling. SMI generates a much slower soft mist cloud which is constantly homogeneous and independent of canister emptying. These peculiarities assessed at bench are suggesting a higher dose consistency and a much more effective therapeutic performance also in real life.]]></description><subject>Inhalers</subject><subject>Velocity</subject><issn>1828-695X</issn><issn>2049-6958</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><recordid>eNpNkU1r3DAQhkVoIMs2t_6AgVxa2N1Ilj_k3sqmHwtZckgKuRlJHsUOXmkryQn-cflvldkcosNIDM88GngJ-cLoJqeCXR_8YZNRVm2ynJ6RRUbzel3WhfhEFkxkYn4_XpDLEJ5pOmXBeJEvyNvOhihthBccnO7jBNK2oJ0NfYho9QTOAB76GDG1Bzem2kn7hKAmiB1C2xuDHpNhwOQIM6-lnac9mH4YevsEr33sYI-plSw3LiDsbCcH9AG-7m924dsK1BjBunhC752JsE-OD9z9PnHfQYJKa3UQ4thOn8m5kUPAy_d7Sf7--vmw_bO-vfu92_64XWtGOV2LrESFKA01iEoxo7jmguc5x7YqGdVK6IpiWVOsKtYqlem8kLqqpcSKFoIvydXJe_Tu34ghNs9u9DZ92WQ5r8uyEFWZqNWJ0t6F4NE0R98fpJ8aRps5oyZl1MwZpSnK_wPr94dN</recordid><startdate>20171201</startdate><enddate>20171201</enddate><creator>Dal Negro, Roberto W.</creator><creator>Longo, Pietro</creator><creator>Villanis Ziani, Orestepaolo</creator><creator>Bonadiman, Luca</creator><creator>Turco, Paola</creator><general>PAGEPress Publications</general><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7X7</scope><scope>7XB</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>K9.</scope><scope>M0S</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope></search><sort><creationdate>20171201</creationdate><title>Instant velocity and consistency of emitted cloud change by the different levels of canister filling with Metered Dose Inhalers (MDIs), but not with Soft Mist Inhalers (SMIs): a bench study</title><author>Dal Negro, Roberto W. ; Longo, Pietro ; Villanis Ziani, Orestepaolo ; Bonadiman, Luca ; Turco, Paola</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1030-826ebeeaf0feebb1fb3c383443ed7610cb8c70e690e771dbb2c45ac79aae70583</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng ; ita</language><creationdate>2017</creationdate><topic>Inhalers</topic><topic>Velocity</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Dal Negro, Roberto W.</creatorcontrib><creatorcontrib>Longo, Pietro</creatorcontrib><creatorcontrib>Villanis Ziani, Orestepaolo</creatorcontrib><creatorcontrib>Bonadiman, Luca</creatorcontrib><creatorcontrib>Turco, Paola</creatorcontrib><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Health & Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>Health & Medical Collection (Alumni Edition)</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><jtitle>Multidisciplinary respiratory medicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Dal Negro, Roberto W.</au><au>Longo, Pietro</au><au>Villanis Ziani, Orestepaolo</au><au>Bonadiman, Luca</au><au>Turco, Paola</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Instant velocity and consistency of emitted cloud change by the different levels of canister filling with Metered Dose Inhalers (MDIs), but not with Soft Mist Inhalers (SMIs): a bench study</atitle><jtitle>Multidisciplinary respiratory medicine</jtitle><date>2017-12-01</date><risdate>2017</risdate><volume>12</volume><issn>1828-695X</issn><eissn>2049-6958</eissn><abstract><![CDATA[Background: Inhalation is the preferred route for respiratory drug delivery, but several factors contribute to the variability of the respirable dose fraction. Instant velocity and the dynamic characteristics of the droplet cloud represent crucial factors. Aim was to measure and compare the instant velocity and the consistency of emitted cloud from five different MDIs (A - Salbutamol sulphate 100mcg, GSK; B - Salbutamol sulphate 100mcg, Valeas; C - Salmeterol xinafoate/Fluticasone propionate 25/125mcg, GSK; D - Formoterol fumarate/Bechlomethasone propionate 6/100mcg, Chiesi; E - Formoterol fumarate/Fluticasone dipropionate 5/125mcg, Mundipharma) and one SMI (Tiotropium bromide 5mcg, Boehringer Ingelheim), at different distance from the nozzle and canister filling. Methods: Measurements were made at 90, 50, and 10% of canister filling, and at 5, 10, and 20 cm from the nozzle, for a total of 972 puffs. A high speed video photography protocol was adopted and high speed cameras (1.200 frames/ sec.) were used. Data were acquired by means of specialized softwares. Temperature, humidity, and vibrations occurrence were strictly controlled during measurements. Statistics: Anova and p < 0.05 were accepted as the minimum significance level. Results: MDIs generated different Instant velocities: MDI B generated the highest, while MDI A the lowest. As expected, velocity decreased in proportion to the distance from the nozzle. Except with MDI C, instant velocity decreased significantly over the first 50% of canister emptying, but dropped by >33% at 90% of emptying with all other MDIs (p < 0–037; p < 0.001; p < 0.005, and p < 0.001, respectively). Instant velocity was extremely lower (p < 0.001) and constant for all levels of canister filling (p = ns) with SMI. All MDIs had a very fast jet phase, ranging 0.01–0.03 s at 10 cm, and 0.03–0.05 s at 20 cm from the nozzle, without any significant difference from each other (p= ns). MDIs generated a cloud similarly tight (p = ns) at 10 and 20 cm from the nozzle, while it was extremely wider and constant with the SMI (p = 0–001). Also the cloud turbulence was minimized during the SMI emission. Discussion and Conclusions: MDIs are characterized by a substantial variability in both their instant velocity and consistency of the emitted cloud at different levels of canister filling. SMI generates a much slower soft mist cloud which is constantly homogeneous and independent of canister emptying. These peculiarities assessed at bench are suggesting a higher dose consistency and a much more effective therapeutic performance also in real life.]]></abstract><cop>Pavia</cop><pub>PAGEPress Publications</pub><doi>10.4081/mrm.2017.240</doi><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1828-695X |
ispartof | Multidisciplinary respiratory medicine, 2017-12, Vol.12 |
issn | 1828-695X 2049-6958 |
language | eng ; ita |
recordid | cdi_proquest_journals_2439665876 |
source | DOAJ Directory of Open Access Journals; PubMed Central Open Access; Springer Nature OA Free Journals; EZB-FREE-00999 freely available EZB journals; PubMed Central |
subjects | Inhalers Velocity |
title | Instant velocity and consistency of emitted cloud change by the different levels of canister filling with Metered Dose Inhalers (MDIs), but not with Soft Mist Inhalers (SMIs): a bench study |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-21T11%3A27%3A11IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Instant%20velocity%20and%20consistency%20of%20emitted%20cloud%20change%20by%20the%20different%20levels%20of%20canister%20filling%20with%20Metered%20Dose%20Inhalers%20(MDIs),%20but%20not%20with%20Soft%20Mist%20Inhalers%20(SMIs):%20a%20bench%20study&rft.jtitle=Multidisciplinary%20respiratory%20medicine&rft.au=Dal%20Negro,%20Roberto%20W.&rft.date=2017-12-01&rft.volume=12&rft.issn=1828-695X&rft.eissn=2049-6958&rft_id=info:doi/10.4081/mrm.2017.240&rft_dat=%3Cproquest_cross%3E2439665876%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2439665876&rft_id=info:pmid/&rfr_iscdi=true |