Minipotentiostat controlled by smartphone on a micropipette: A versatile, portable, agile and accurate tool for electroanalysis

In this paper, we show an unprecedented device obtained by coupling a small potentiostat to an electronic micropipette. The minipotentiostat is powered by the micropipette battery and controlled by a smartphone via a Bluetooth wireless connection. A set of 3 electrodes is inserted into the tip of th...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Electrochimica acta 2020-05, Vol.341, p.136048, Article 136048
Hauptverfasser: Barragan, José T.C., Kubota, Lauro T.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page 136048
container_title Electrochimica acta
container_volume 341
creator Barragan, José T.C.
Kubota, Lauro T.
description In this paper, we show an unprecedented device obtained by coupling a small potentiostat to an electronic micropipette. The minipotentiostat is powered by the micropipette battery and controlled by a smartphone via a Bluetooth wireless connection. A set of 3 electrodes is inserted into the tip of the micropipette with the aid of an adapter that allows electrochemical measurements to be carried out without affecting the precision and trueness of handling of small volumes of liquid. Studies with the device show significant gains in portability, versatility, agility and for analytical procedures. This approach requires small volume of samples and reagents with the possibility of recovery after analysis. Determination of hydrogen peroxide with the aim for future development of enzymatic biosensors for clinical analysis was shown as an example of application. We consider that the device shown here contributes to a new way to performing electrochemical analysis on site. [Display omitted] •New manner for performing electrochemistry procedures.•Accuracy, versatility, portability, quickness and possibility of content recovery.•Less chemicals, samples, waste, dispended time.•Fully portable controlled by smartphone.•Volumetric and analytical calibration possibilities.
doi_str_mv 10.1016/j.electacta.2020.136048
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2438723536</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0013468620304400</els_id><sourcerecordid>2438723536</sourcerecordid><originalsourceid>FETCH-LOGICAL-c343t-5e3d1eb39dd552d715d368e4ecc5165e389afc7397e42233cd9adeff35ae5c193</originalsourceid><addsrcrecordid>eNqFkE1LAzEQhoMoWKu_wYBXtyY7m_3wVopfUPGi55Ams5qy3axJWujJv27qildhYIaZd15mHkIuOZtxxsub9Qw71FGlmOUsT10oWVEfkQmvK8igFs0xmTDGISvKujwlZyGsGWNVWbEJ-Xq2vR1cxD5aF6KKVLs-etd1aOhqT8NG-Th8uB6p66miG6u9G-yAMeItndMd-qCi7fCaDs5HtTpU6j01qOoNVVpvvYpIo3MdbZ2nP8d6p3rV7YMN5-SkVV3Ai988JW_3d6-Lx2z58vC0mC8zDQXETCAYjitojBEiNxUXBsoaC9Ra8DJN60a1uoKmwiLPAbRplMG2BaFQaN7AlFyNvoN3n1sMUa7d1qcjgswLqKscBJRJVY2q9GQIHls5eJsI7CVn8kBbruUfbXmgLUfaaXM-bmJ6YmfRy6At9hqN9UkvjbP_enwD0POPyg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2438723536</pqid></control><display><type>article</type><title>Minipotentiostat controlled by smartphone on a micropipette: A versatile, portable, agile and accurate tool for electroanalysis</title><source>Elsevier ScienceDirect Journals</source><creator>Barragan, José T.C. ; Kubota, Lauro T.</creator><creatorcontrib>Barragan, José T.C. ; Kubota, Lauro T.</creatorcontrib><description>In this paper, we show an unprecedented device obtained by coupling a small potentiostat to an electronic micropipette. The minipotentiostat is powered by the micropipette battery and controlled by a smartphone via a Bluetooth wireless connection. A set of 3 electrodes is inserted into the tip of the micropipette with the aid of an adapter that allows electrochemical measurements to be carried out without affecting the precision and trueness of handling of small volumes of liquid. Studies with the device show significant gains in portability, versatility, agility and for analytical procedures. This approach requires small volume of samples and reagents with the possibility of recovery after analysis. Determination of hydrogen peroxide with the aim for future development of enzymatic biosensors for clinical analysis was shown as an example of application. We consider that the device shown here contributes to a new way to performing electrochemical analysis on site. [Display omitted] •New manner for performing electrochemistry procedures.•Accuracy, versatility, portability, quickness and possibility of content recovery.•Less chemicals, samples, waste, dispended time.•Fully portable controlled by smartphone.•Volumetric and analytical calibration possibilities.</description><identifier>ISSN: 0013-4686</identifier><identifier>EISSN: 1873-3859</identifier><identifier>DOI: 10.1016/j.electacta.2020.136048</identifier><language>eng</language><publisher>Oxford: Elsevier Ltd</publisher><subject>Adapters ; Arduino ; Biosensors ; Bluetooth ; Electroanalysis ; Electrochemical analysis ; Electrolytic analysis ; Hydrogen peroxide ; Micropipette ; Portable potentiostat ; Reagents ; Smartphone ; Smartphones</subject><ispartof>Electrochimica acta, 2020-05, Vol.341, p.136048, Article 136048</ispartof><rights>2020 Elsevier Ltd</rights><rights>Copyright Elsevier BV May 1, 2020</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c343t-5e3d1eb39dd552d715d368e4ecc5165e389afc7397e42233cd9adeff35ae5c193</citedby><cites>FETCH-LOGICAL-c343t-5e3d1eb39dd552d715d368e4ecc5165e389afc7397e42233cd9adeff35ae5c193</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0013468620304400$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids></links><search><creatorcontrib>Barragan, José T.C.</creatorcontrib><creatorcontrib>Kubota, Lauro T.</creatorcontrib><title>Minipotentiostat controlled by smartphone on a micropipette: A versatile, portable, agile and accurate tool for electroanalysis</title><title>Electrochimica acta</title><description>In this paper, we show an unprecedented device obtained by coupling a small potentiostat to an electronic micropipette. The minipotentiostat is powered by the micropipette battery and controlled by a smartphone via a Bluetooth wireless connection. A set of 3 electrodes is inserted into the tip of the micropipette with the aid of an adapter that allows electrochemical measurements to be carried out without affecting the precision and trueness of handling of small volumes of liquid. Studies with the device show significant gains in portability, versatility, agility and for analytical procedures. This approach requires small volume of samples and reagents with the possibility of recovery after analysis. Determination of hydrogen peroxide with the aim for future development of enzymatic biosensors for clinical analysis was shown as an example of application. We consider that the device shown here contributes to a new way to performing electrochemical analysis on site. [Display omitted] •New manner for performing electrochemistry procedures.•Accuracy, versatility, portability, quickness and possibility of content recovery.•Less chemicals, samples, waste, dispended time.•Fully portable controlled by smartphone.•Volumetric and analytical calibration possibilities.</description><subject>Adapters</subject><subject>Arduino</subject><subject>Biosensors</subject><subject>Bluetooth</subject><subject>Electroanalysis</subject><subject>Electrochemical analysis</subject><subject>Electrolytic analysis</subject><subject>Hydrogen peroxide</subject><subject>Micropipette</subject><subject>Portable potentiostat</subject><subject>Reagents</subject><subject>Smartphone</subject><subject>Smartphones</subject><issn>0013-4686</issn><issn>1873-3859</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNqFkE1LAzEQhoMoWKu_wYBXtyY7m_3wVopfUPGi55Ams5qy3axJWujJv27qildhYIaZd15mHkIuOZtxxsub9Qw71FGlmOUsT10oWVEfkQmvK8igFs0xmTDGISvKujwlZyGsGWNVWbEJ-Xq2vR1cxD5aF6KKVLs-etd1aOhqT8NG-Th8uB6p66miG6u9G-yAMeItndMd-qCi7fCaDs5HtTpU6j01qOoNVVpvvYpIo3MdbZ2nP8d6p3rV7YMN5-SkVV3Ai988JW_3d6-Lx2z58vC0mC8zDQXETCAYjitojBEiNxUXBsoaC9Ra8DJN60a1uoKmwiLPAbRplMG2BaFQaN7AlFyNvoN3n1sMUa7d1qcjgswLqKscBJRJVY2q9GQIHls5eJsI7CVn8kBbruUfbXmgLUfaaXM-bmJ6YmfRy6At9hqN9UkvjbP_enwD0POPyg</recordid><startdate>20200501</startdate><enddate>20200501</enddate><creator>Barragan, José T.C.</creator><creator>Kubota, Lauro T.</creator><general>Elsevier Ltd</general><general>Elsevier BV</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SR</scope><scope>7U5</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope><scope>L7M</scope></search><sort><creationdate>20200501</creationdate><title>Minipotentiostat controlled by smartphone on a micropipette: A versatile, portable, agile and accurate tool for electroanalysis</title><author>Barragan, José T.C. ; Kubota, Lauro T.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c343t-5e3d1eb39dd552d715d368e4ecc5165e389afc7397e42233cd9adeff35ae5c193</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Adapters</topic><topic>Arduino</topic><topic>Biosensors</topic><topic>Bluetooth</topic><topic>Electroanalysis</topic><topic>Electrochemical analysis</topic><topic>Electrolytic analysis</topic><topic>Hydrogen peroxide</topic><topic>Micropipette</topic><topic>Portable potentiostat</topic><topic>Reagents</topic><topic>Smartphone</topic><topic>Smartphones</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Barragan, José T.C.</creatorcontrib><creatorcontrib>Kubota, Lauro T.</creatorcontrib><collection>CrossRef</collection><collection>Engineered Materials Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Electrochimica acta</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Barragan, José T.C.</au><au>Kubota, Lauro T.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Minipotentiostat controlled by smartphone on a micropipette: A versatile, portable, agile and accurate tool for electroanalysis</atitle><jtitle>Electrochimica acta</jtitle><date>2020-05-01</date><risdate>2020</risdate><volume>341</volume><spage>136048</spage><pages>136048-</pages><artnum>136048</artnum><issn>0013-4686</issn><eissn>1873-3859</eissn><abstract>In this paper, we show an unprecedented device obtained by coupling a small potentiostat to an electronic micropipette. The minipotentiostat is powered by the micropipette battery and controlled by a smartphone via a Bluetooth wireless connection. A set of 3 electrodes is inserted into the tip of the micropipette with the aid of an adapter that allows electrochemical measurements to be carried out without affecting the precision and trueness of handling of small volumes of liquid. Studies with the device show significant gains in portability, versatility, agility and for analytical procedures. This approach requires small volume of samples and reagents with the possibility of recovery after analysis. Determination of hydrogen peroxide with the aim for future development of enzymatic biosensors for clinical analysis was shown as an example of application. We consider that the device shown here contributes to a new way to performing electrochemical analysis on site. [Display omitted] •New manner for performing electrochemistry procedures.•Accuracy, versatility, portability, quickness and possibility of content recovery.•Less chemicals, samples, waste, dispended time.•Fully portable controlled by smartphone.•Volumetric and analytical calibration possibilities.</abstract><cop>Oxford</cop><pub>Elsevier Ltd</pub><doi>10.1016/j.electacta.2020.136048</doi></addata></record>
fulltext fulltext
identifier ISSN: 0013-4686
ispartof Electrochimica acta, 2020-05, Vol.341, p.136048, Article 136048
issn 0013-4686
1873-3859
language eng
recordid cdi_proquest_journals_2438723536
source Elsevier ScienceDirect Journals
subjects Adapters
Arduino
Biosensors
Bluetooth
Electroanalysis
Electrochemical analysis
Electrolytic analysis
Hydrogen peroxide
Micropipette
Portable potentiostat
Reagents
Smartphone
Smartphones
title Minipotentiostat controlled by smartphone on a micropipette: A versatile, portable, agile and accurate tool for electroanalysis
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-01T22%3A52%3A10IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Minipotentiostat%20controlled%20by%20smartphone%20on%20a%20micropipette:%20A%20versatile,%20portable,%20agile%20and%20accurate%20tool%20for%20electroanalysis&rft.jtitle=Electrochimica%20acta&rft.au=Barragan,%20Jos%C3%A9%20T.C.&rft.date=2020-05-01&rft.volume=341&rft.spage=136048&rft.pages=136048-&rft.artnum=136048&rft.issn=0013-4686&rft.eissn=1873-3859&rft_id=info:doi/10.1016/j.electacta.2020.136048&rft_dat=%3Cproquest_cross%3E2438723536%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2438723536&rft_id=info:pmid/&rft_els_id=S0013468620304400&rfr_iscdi=true