ON THE ACCURACY OF AVAILABLE WAVENUMBER VALUES FOR ELECTRONIC-VIBRO-ROTATIONAL TRANSITIONS OF THE H2 MOLECULE

All published to date experimental wavenumber values (ν, cm –1 ) for electronic-vibro-rotational transitions of the H 2 molecule are statistically analyzed in the vacuum wavelength range 1/ν = 600—610 nm. It is shown that a direct comparison of all datasets of various authors is blocked by the absen...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Bulletin of the Lebedev Physics Institute 2020-05, Vol.47 (5), p.127-131
Hauptverfasser: Diachkova, O. O., Lavrov, B. P., Mikhailov, A. S., Riazantceva, V. A.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 131
container_issue 5
container_start_page 127
container_title Bulletin of the Lebedev Physics Institute
container_volume 47
creator Diachkova, O. O.
Lavrov, B. P.
Mikhailov, A. S.
Riazantceva, V. A.
description All published to date experimental wavenumber values (ν, cm –1 ) for electronic-vibro-rotational transitions of the H 2 molecule are statistically analyzed in the vacuum wavelength range 1/ν = 600—610 nm. It is shown that a direct comparison of all datasets of various authors is blocked by the absence of deconvolving of measured spectra, blending of neighbor lines (an overlap of their profiles), and fragmentary data of most studies. Therefore, it is proposed to compare all available data with the dispersion curve of a high-resolution spectrometer by measuring and deconvolving the H 2 spectra. An experimental study of such an opportunity showed that the proposed approach makes it possible not only to analyze the scatter of available data on 1/ν and ν (standard deviations are about 0.003 nm and 0.08 cm –1 ), but also to obtain more reliable datasets with uncertainties (95% confidence intervals) less than 0.0006 nm and 0.02 cm –1 respectively.
doi_str_mv 10.3103/S1068335620050036
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2420713449</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2420713449</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1836-d47d3f6109807b7b41bbedb27caab1115ee2f9faeb6a9570a0b38913d8146b453</originalsourceid><addsrcrecordid>eNp1kEtPwzAQhC0EEqXwA7hZ4hzwxk7iHN3IpZHcWMoLOEVx6yAq-iChB_49jorEAXHaXc3Mt9IgdAvkngKhDwWQkFMahD4hASE0PEMTiCnzOOXP5253sjfql-hqGDbOFPA4mKCtznC5kFgkSZWL5AXrORa1SJWYKYmfRC2zajmTOa6FqmSB5zrHUsmkzHWWJl6dznLt5boUZaozoXCZi6xIx6MYUSN64eOldpFKyWt00bXvg735mVNUzWWZLDylH9NEKG8FnIbemkVr2oVAYk4iExkGxti18aNV2xoACKz1u7hrrQnbOIhISwzlMdA1BxYaFtApujtxD_3-42iHz2azP_Y797LxmU8ioIzFzgUn16rfD0Nvu-bQv23b_qsB0oytNn9adRn_lBmcd_dq-1_y_6FvsVtu6Q</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2420713449</pqid></control><display><type>article</type><title>ON THE ACCURACY OF AVAILABLE WAVENUMBER VALUES FOR ELECTRONIC-VIBRO-ROTATIONAL TRANSITIONS OF THE H2 MOLECULE</title><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>Springer Nature - Complete Springer Journals</source><creator>Diachkova, O. O. ; Lavrov, B. P. ; Mikhailov, A. S. ; Riazantceva, V. A.</creator><creatorcontrib>Diachkova, O. O. ; Lavrov, B. P. ; Mikhailov, A. S. ; Riazantceva, V. A.</creatorcontrib><description>All published to date experimental wavenumber values (ν, cm –1 ) for electronic-vibro-rotational transitions of the H 2 molecule are statistically analyzed in the vacuum wavelength range 1/ν = 600—610 nm. It is shown that a direct comparison of all datasets of various authors is blocked by the absence of deconvolving of measured spectra, blending of neighbor lines (an overlap of their profiles), and fragmentary data of most studies. Therefore, it is proposed to compare all available data with the dispersion curve of a high-resolution spectrometer by measuring and deconvolving the H 2 spectra. An experimental study of such an opportunity showed that the proposed approach makes it possible not only to analyze the scatter of available data on 1/ν and ν (standard deviations are about 0.003 nm and 0.08 cm –1 ), but also to obtain more reliable datasets with uncertainties (95% confidence intervals) less than 0.0006 nm and 0.02 cm –1 respectively.</description><identifier>ISSN: 1068-3356</identifier><identifier>EISSN: 1934-838X</identifier><identifier>DOI: 10.3103/S1068335620050036</identifier><language>eng</language><publisher>Moscow: Pleiades Publishing</publisher><subject>Confidence intervals ; Datasets ; Dispersion curve analysis ; Line spectra ; Physics ; Physics and Astronomy ; Wavelengths</subject><ispartof>Bulletin of the Lebedev Physics Institute, 2020-05, Vol.47 (5), p.127-131</ispartof><rights>Allerton Press, Inc. 2020</rights><rights>Allerton Press, Inc. 2020.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c1836-d47d3f6109807b7b41bbedb27caab1115ee2f9faeb6a9570a0b38913d8146b453</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.3103/S1068335620050036$$EPDF$$P50$$Gspringer$$H</linktopdf><linktohtml>$$Uhttps://link.springer.com/10.3103/S1068335620050036$$EHTML$$P50$$Gspringer$$H</linktohtml><link.rule.ids>314,777,781,27905,27906,41469,42538,51300</link.rule.ids></links><search><creatorcontrib>Diachkova, O. O.</creatorcontrib><creatorcontrib>Lavrov, B. P.</creatorcontrib><creatorcontrib>Mikhailov, A. S.</creatorcontrib><creatorcontrib>Riazantceva, V. A.</creatorcontrib><title>ON THE ACCURACY OF AVAILABLE WAVENUMBER VALUES FOR ELECTRONIC-VIBRO-ROTATIONAL TRANSITIONS OF THE H2 MOLECULE</title><title>Bulletin of the Lebedev Physics Institute</title><addtitle>Bull. Lebedev Phys. Inst</addtitle><description>All published to date experimental wavenumber values (ν, cm –1 ) for electronic-vibro-rotational transitions of the H 2 molecule are statistically analyzed in the vacuum wavelength range 1/ν = 600—610 nm. It is shown that a direct comparison of all datasets of various authors is blocked by the absence of deconvolving of measured spectra, blending of neighbor lines (an overlap of their profiles), and fragmentary data of most studies. Therefore, it is proposed to compare all available data with the dispersion curve of a high-resolution spectrometer by measuring and deconvolving the H 2 spectra. An experimental study of such an opportunity showed that the proposed approach makes it possible not only to analyze the scatter of available data on 1/ν and ν (standard deviations are about 0.003 nm and 0.08 cm –1 ), but also to obtain more reliable datasets with uncertainties (95% confidence intervals) less than 0.0006 nm and 0.02 cm –1 respectively.</description><subject>Confidence intervals</subject><subject>Datasets</subject><subject>Dispersion curve analysis</subject><subject>Line spectra</subject><subject>Physics</subject><subject>Physics and Astronomy</subject><subject>Wavelengths</subject><issn>1068-3356</issn><issn>1934-838X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNp1kEtPwzAQhC0EEqXwA7hZ4hzwxk7iHN3IpZHcWMoLOEVx6yAq-iChB_49jorEAXHaXc3Mt9IgdAvkngKhDwWQkFMahD4hASE0PEMTiCnzOOXP5253sjfql-hqGDbOFPA4mKCtznC5kFgkSZWL5AXrORa1SJWYKYmfRC2zajmTOa6FqmSB5zrHUsmkzHWWJl6dznLt5boUZaozoXCZi6xIx6MYUSN64eOldpFKyWt00bXvg735mVNUzWWZLDylH9NEKG8FnIbemkVr2oVAYk4iExkGxti18aNV2xoACKz1u7hrrQnbOIhISwzlMdA1BxYaFtApujtxD_3-42iHz2azP_Y797LxmU8ioIzFzgUn16rfD0Nvu-bQv23b_qsB0oytNn9adRn_lBmcd_dq-1_y_6FvsVtu6Q</recordid><startdate>20200501</startdate><enddate>20200501</enddate><creator>Diachkova, O. O.</creator><creator>Lavrov, B. P.</creator><creator>Mikhailov, A. S.</creator><creator>Riazantceva, V. A.</creator><general>Pleiades Publishing</general><general>Springer Nature B.V</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20200501</creationdate><title>ON THE ACCURACY OF AVAILABLE WAVENUMBER VALUES FOR ELECTRONIC-VIBRO-ROTATIONAL TRANSITIONS OF THE H2 MOLECULE</title><author>Diachkova, O. O. ; Lavrov, B. P. ; Mikhailov, A. S. ; Riazantceva, V. A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1836-d47d3f6109807b7b41bbedb27caab1115ee2f9faeb6a9570a0b38913d8146b453</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Confidence intervals</topic><topic>Datasets</topic><topic>Dispersion curve analysis</topic><topic>Line spectra</topic><topic>Physics</topic><topic>Physics and Astronomy</topic><topic>Wavelengths</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Diachkova, O. O.</creatorcontrib><creatorcontrib>Lavrov, B. P.</creatorcontrib><creatorcontrib>Mikhailov, A. S.</creatorcontrib><creatorcontrib>Riazantceva, V. A.</creatorcontrib><collection>CrossRef</collection><jtitle>Bulletin of the Lebedev Physics Institute</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Diachkova, O. O.</au><au>Lavrov, B. P.</au><au>Mikhailov, A. S.</au><au>Riazantceva, V. A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>ON THE ACCURACY OF AVAILABLE WAVENUMBER VALUES FOR ELECTRONIC-VIBRO-ROTATIONAL TRANSITIONS OF THE H2 MOLECULE</atitle><jtitle>Bulletin of the Lebedev Physics Institute</jtitle><stitle>Bull. Lebedev Phys. Inst</stitle><date>2020-05-01</date><risdate>2020</risdate><volume>47</volume><issue>5</issue><spage>127</spage><epage>131</epage><pages>127-131</pages><issn>1068-3356</issn><eissn>1934-838X</eissn><abstract>All published to date experimental wavenumber values (ν, cm –1 ) for electronic-vibro-rotational transitions of the H 2 molecule are statistically analyzed in the vacuum wavelength range 1/ν = 600—610 nm. It is shown that a direct comparison of all datasets of various authors is blocked by the absence of deconvolving of measured spectra, blending of neighbor lines (an overlap of their profiles), and fragmentary data of most studies. Therefore, it is proposed to compare all available data with the dispersion curve of a high-resolution spectrometer by measuring and deconvolving the H 2 spectra. An experimental study of such an opportunity showed that the proposed approach makes it possible not only to analyze the scatter of available data on 1/ν and ν (standard deviations are about 0.003 nm and 0.08 cm –1 ), but also to obtain more reliable datasets with uncertainties (95% confidence intervals) less than 0.0006 nm and 0.02 cm –1 respectively.</abstract><cop>Moscow</cop><pub>Pleiades Publishing</pub><doi>10.3103/S1068335620050036</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1068-3356
ispartof Bulletin of the Lebedev Physics Institute, 2020-05, Vol.47 (5), p.127-131
issn 1068-3356
1934-838X
language eng
recordid cdi_proquest_journals_2420713449
source Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; Springer Nature - Complete Springer Journals
subjects Confidence intervals
Datasets
Dispersion curve analysis
Line spectra
Physics
Physics and Astronomy
Wavelengths
title ON THE ACCURACY OF AVAILABLE WAVENUMBER VALUES FOR ELECTRONIC-VIBRO-ROTATIONAL TRANSITIONS OF THE H2 MOLECULE
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-20T07%3A18%3A44IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=ON%20THE%20ACCURACY%20OF%20AVAILABLE%20WAVENUMBER%20VALUES%20FOR%20ELECTRONIC-VIBRO-ROTATIONAL%20TRANSITIONS%20OF%20THE%20H2%20MOLECULE&rft.jtitle=Bulletin%20of%20the%20Lebedev%20Physics%20Institute&rft.au=Diachkova,%20O.%20O.&rft.date=2020-05-01&rft.volume=47&rft.issue=5&rft.spage=127&rft.epage=131&rft.pages=127-131&rft.issn=1068-3356&rft.eissn=1934-838X&rft_id=info:doi/10.3103/S1068335620050036&rft_dat=%3Cproquest_cross%3E2420713449%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2420713449&rft_id=info:pmid/&rfr_iscdi=true