Preservation of Bone Tissue Quality during the Usage of Synthetic Bioactive Calcium Phosphate Mineral Coating for Prevention of Metallic Construction Migration
This work is devoted to studying the reaction of bone tissue to installed titanium implants, which are bioinert in comparison with other metals used in traumatological and orthopedic practice, but which have a negative effect on bone tissue in the implant-to-bone area. In order to increase the affin...
Gespeichert in:
Veröffentlicht in: | Journal of biomimetics, biomaterials and biomedical engineering biomaterials and biomedical engineering, 2020-06, Vol.46, p.67-74 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 74 |
---|---|
container_issue | |
container_start_page | 67 |
container_title | Journal of biomimetics, biomaterials and biomedical engineering |
container_volume | 46 |
creator | Markov, Alexander Ponomarev, Andrey Zavatskij, Mikhail Krylov, Sergej Naumov, Mikhail Stepanova, Ksenya |
description | This work is devoted to studying the reaction of bone tissue to installed titanium implants, which are bioinert in comparison with other metals used in traumatological and orthopedic practice, but which have a negative effect on bone tissue in the implant-to-bone area. In order to increase the affinity of the implant surface with bone tissue, it was proposed to use synthetic bioactive calcium phosphate mineral coating by applying it on titanium implants, which ultimately will make it possible to maintain the quality of the bone tissue around the implant after osteosynthesis or prosthetics. During the comparative research an in vivo experiment was conducted in which quality change of peri-implant zone of bone tissue when using titanium implants with synthetic bioactive calcium phosphate mineral coating and titanium implants without bioactive coating was analyzed. To analyze the results of the study, we used the X-ray computed tomography method, for a detailed assessment of the X-ray density and bone mineral density of the peri-implant zone. According to the results of the experiment, it was concluded that the reaction of bone tissue to synthetic bioactive calcium phosphate mineral coating of titanium implants was reduced, what ensures the preservation of bone tissue quality in the postoperative period at a high level. |
doi_str_mv | 10.4028/www.scientific.net/JBBBE.46.67 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2414890723</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2414890723</sourcerecordid><originalsourceid>FETCH-LOGICAL-c295t-c49fc69f36fa7793f06a3a65a5aee5bf670b1d221c65bcfd73e06390a95a90333</originalsourceid><addsrcrecordid>eNqNkc1qGzEURofQQEKSdxAUuvNEM9JorE1pZ0h_QkwSmqzFtXxlK0wkV9LY-Gn6qpXt0myzkoQ-zrmXryg-VbTktJ5eb7fbMmqLLlljdekwXd92XXdTclGK9qQ4r2spJnLKmw__76w9K65ifKGUVkJKTvl58echYMSwgWS9I96QzjskTzbGEcnjCINNO7IYg3VLklZIniMscZ_7tXP5nawmnfWgk90g6WHQdnwlDysf1ytISGbWYYCB9D4LMsL4QLJxs5_76JthgmHImN67mMKoDx8zuwyHkS6LUwNDxKt_50Xx_O3mqf8xubv__rP_ejfRtWzSRHNptJCGCQNtK5mhAhiIBhpAbOZGtHReLeq60qKZa7NoGVLBJAXZgKSMsYvi45G7Dv73iDGpFz8Gl5Wq5hWfStrW-9TnY0oHH2NAo9bBvkLYqYqqfS8q96LeelG5F3XoRXGhRJsBX46AFCCvi3r15nkn4i_jGaMS</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2414890723</pqid></control><display><type>article</type><title>Preservation of Bone Tissue Quality during the Usage of Synthetic Bioactive Calcium Phosphate Mineral Coating for Prevention of Metallic Construction Migration</title><source>Scientific.net Journals</source><creator>Markov, Alexander ; Ponomarev, Andrey ; Zavatskij, Mikhail ; Krylov, Sergej ; Naumov, Mikhail ; Stepanova, Ksenya</creator><creatorcontrib>Markov, Alexander ; Ponomarev, Andrey ; Zavatskij, Mikhail ; Krylov, Sergej ; Naumov, Mikhail ; Stepanova, Ksenya</creatorcontrib><description>This work is devoted to studying the reaction of bone tissue to installed titanium implants, which are bioinert in comparison with other metals used in traumatological and orthopedic practice, but which have a negative effect on bone tissue in the implant-to-bone area. In order to increase the affinity of the implant surface with bone tissue, it was proposed to use synthetic bioactive calcium phosphate mineral coating by applying it on titanium implants, which ultimately will make it possible to maintain the quality of the bone tissue around the implant after osteosynthesis or prosthetics. During the comparative research an in vivo experiment was conducted in which quality change of peri-implant zone of bone tissue when using titanium implants with synthetic bioactive calcium phosphate mineral coating and titanium implants without bioactive coating was analyzed. To analyze the results of the study, we used the X-ray computed tomography method, for a detailed assessment of the X-ray density and bone mineral density of the peri-implant zone. According to the results of the experiment, it was concluded that the reaction of bone tissue to synthetic bioactive calcium phosphate mineral coating of titanium implants was reduced, what ensures the preservation of bone tissue quality in the postoperative period at a high level.</description><identifier>ISSN: 2296-9837</identifier><identifier>ISSN: 2296-9845</identifier><identifier>EISSN: 2296-9845</identifier><identifier>DOI: 10.4028/www.scientific.net/JBBBE.46.67</identifier><language>eng</language><publisher>Pfäffikon: Trans Tech Publications Ltd</publisher><subject>Biological activity ; Biomedical materials ; Bone implants ; Bone mineral density ; Bones ; Calcium phosphates ; Coating ; Coatings ; Computed tomography ; Metals ; Orthopedics ; Osteosynthesis ; Preservation ; Prostheses ; Prosthetics ; Surgical implants ; Tissues ; Titanium ; Transplants & implants</subject><ispartof>Journal of biomimetics, biomaterials and biomedical engineering, 2020-06, Vol.46, p.67-74</ispartof><rights>2020 Trans Tech Publications Ltd</rights><rights>Copyright Trans Tech Publications Ltd. Jun 2020</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c295t-c49fc69f36fa7793f06a3a65a5aee5bf670b1d221c65bcfd73e06390a95a90333</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Uhttps://www.scientific.net/Image/TitleCover/4488?width=600</thumbnail><link.rule.ids>314,777,781,27905,27906</link.rule.ids></links><search><creatorcontrib>Markov, Alexander</creatorcontrib><creatorcontrib>Ponomarev, Andrey</creatorcontrib><creatorcontrib>Zavatskij, Mikhail</creatorcontrib><creatorcontrib>Krylov, Sergej</creatorcontrib><creatorcontrib>Naumov, Mikhail</creatorcontrib><creatorcontrib>Stepanova, Ksenya</creatorcontrib><title>Preservation of Bone Tissue Quality during the Usage of Synthetic Bioactive Calcium Phosphate Mineral Coating for Prevention of Metallic Construction Migration</title><title>Journal of biomimetics, biomaterials and biomedical engineering</title><description>This work is devoted to studying the reaction of bone tissue to installed titanium implants, which are bioinert in comparison with other metals used in traumatological and orthopedic practice, but which have a negative effect on bone tissue in the implant-to-bone area. In order to increase the affinity of the implant surface with bone tissue, it was proposed to use synthetic bioactive calcium phosphate mineral coating by applying it on titanium implants, which ultimately will make it possible to maintain the quality of the bone tissue around the implant after osteosynthesis or prosthetics. During the comparative research an in vivo experiment was conducted in which quality change of peri-implant zone of bone tissue when using titanium implants with synthetic bioactive calcium phosphate mineral coating and titanium implants without bioactive coating was analyzed. To analyze the results of the study, we used the X-ray computed tomography method, for a detailed assessment of the X-ray density and bone mineral density of the peri-implant zone. According to the results of the experiment, it was concluded that the reaction of bone tissue to synthetic bioactive calcium phosphate mineral coating of titanium implants was reduced, what ensures the preservation of bone tissue quality in the postoperative period at a high level.</description><subject>Biological activity</subject><subject>Biomedical materials</subject><subject>Bone implants</subject><subject>Bone mineral density</subject><subject>Bones</subject><subject>Calcium phosphates</subject><subject>Coating</subject><subject>Coatings</subject><subject>Computed tomography</subject><subject>Metals</subject><subject>Orthopedics</subject><subject>Osteosynthesis</subject><subject>Preservation</subject><subject>Prostheses</subject><subject>Prosthetics</subject><subject>Surgical implants</subject><subject>Tissues</subject><subject>Titanium</subject><subject>Transplants & implants</subject><issn>2296-9837</issn><issn>2296-9845</issn><issn>2296-9845</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><sourceid>GNUQQ</sourceid><recordid>eNqNkc1qGzEURofQQEKSdxAUuvNEM9JorE1pZ0h_QkwSmqzFtXxlK0wkV9LY-Gn6qpXt0myzkoQ-zrmXryg-VbTktJ5eb7fbMmqLLlljdekwXd92XXdTclGK9qQ4r2spJnLKmw__76w9K65ifKGUVkJKTvl58echYMSwgWS9I96QzjskTzbGEcnjCINNO7IYg3VLklZIniMscZ_7tXP5nawmnfWgk90g6WHQdnwlDysf1ytISGbWYYCB9D4LMsL4QLJxs5_76JthgmHImN67mMKoDx8zuwyHkS6LUwNDxKt_50Xx_O3mqf8xubv__rP_ejfRtWzSRHNptJCGCQNtK5mhAhiIBhpAbOZGtHReLeq60qKZa7NoGVLBJAXZgKSMsYvi45G7Dv73iDGpFz8Gl5Wq5hWfStrW-9TnY0oHH2NAo9bBvkLYqYqqfS8q96LeelG5F3XoRXGhRJsBX46AFCCvi3r15nkn4i_jGaMS</recordid><startdate>20200601</startdate><enddate>20200601</enddate><creator>Markov, Alexander</creator><creator>Ponomarev, Andrey</creator><creator>Zavatskij, Mikhail</creator><creator>Krylov, Sergej</creator><creator>Naumov, Mikhail</creator><creator>Stepanova, Ksenya</creator><general>Trans Tech Publications Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7QF</scope><scope>7QO</scope><scope>7QP</scope><scope>7QQ</scope><scope>7SE</scope><scope>7SR</scope><scope>7T5</scope><scope>7TB</scope><scope>8BQ</scope><scope>8FD</scope><scope>8FE</scope><scope>8FG</scope><scope>8FH</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AEUYN</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BBNVY</scope><scope>BENPR</scope><scope>BFMQW</scope><scope>BGLVJ</scope><scope>BHPHI</scope><scope>CCPQU</scope><scope>D1I</scope><scope>DWQXO</scope><scope>FR3</scope><scope>GNUQQ</scope><scope>H94</scope><scope>HCIFZ</scope><scope>JG9</scope><scope>KB.</scope><scope>L6V</scope><scope>LK8</scope><scope>M7P</scope><scope>M7S</scope><scope>P64</scope><scope>PDBOC</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PTHSS</scope></search><sort><creationdate>20200601</creationdate><title>Preservation of Bone Tissue Quality during the Usage of Synthetic Bioactive Calcium Phosphate Mineral Coating for Prevention of Metallic Construction Migration</title><author>Markov, Alexander ; Ponomarev, Andrey ; Zavatskij, Mikhail ; Krylov, Sergej ; Naumov, Mikhail ; Stepanova, Ksenya</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c295t-c49fc69f36fa7793f06a3a65a5aee5bf670b1d221c65bcfd73e06390a95a90333</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Biological activity</topic><topic>Biomedical materials</topic><topic>Bone implants</topic><topic>Bone mineral density</topic><topic>Bones</topic><topic>Calcium phosphates</topic><topic>Coating</topic><topic>Coatings</topic><topic>Computed tomography</topic><topic>Metals</topic><topic>Orthopedics</topic><topic>Osteosynthesis</topic><topic>Preservation</topic><topic>Prostheses</topic><topic>Prosthetics</topic><topic>Surgical implants</topic><topic>Tissues</topic><topic>Titanium</topic><topic>Transplants & implants</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Markov, Alexander</creatorcontrib><creatorcontrib>Ponomarev, Andrey</creatorcontrib><creatorcontrib>Zavatskij, Mikhail</creatorcontrib><creatorcontrib>Krylov, Sergej</creatorcontrib><creatorcontrib>Naumov, Mikhail</creatorcontrib><creatorcontrib>Stepanova, Ksenya</creatorcontrib><collection>CrossRef</collection><collection>Aluminium Industry Abstracts</collection><collection>Biotechnology Research Abstracts</collection><collection>Calcium & Calcified Tissue Abstracts</collection><collection>Ceramic Abstracts</collection><collection>Corrosion Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Immunology Abstracts</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>ProQuest Natural Science Collection</collection><collection>Materials Science & Engineering Collection</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest One Sustainability</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>Biological Science Collection</collection><collection>ProQuest Central</collection><collection>Continental Europe Database</collection><collection>Technology Collection</collection><collection>Natural Science Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Materials Science Collection</collection><collection>ProQuest Central Korea</collection><collection>Engineering Research Database</collection><collection>ProQuest Central Student</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>SciTech Premium Collection</collection><collection>Materials Research Database</collection><collection>Materials Science Database</collection><collection>ProQuest Engineering Collection</collection><collection>ProQuest Biological Science Collection</collection><collection>Biological Science Database</collection><collection>Engineering Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>Materials Science Collection</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>Engineering Collection</collection><jtitle>Journal of biomimetics, biomaterials and biomedical engineering</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Markov, Alexander</au><au>Ponomarev, Andrey</au><au>Zavatskij, Mikhail</au><au>Krylov, Sergej</au><au>Naumov, Mikhail</au><au>Stepanova, Ksenya</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Preservation of Bone Tissue Quality during the Usage of Synthetic Bioactive Calcium Phosphate Mineral Coating for Prevention of Metallic Construction Migration</atitle><jtitle>Journal of biomimetics, biomaterials and biomedical engineering</jtitle><date>2020-06-01</date><risdate>2020</risdate><volume>46</volume><spage>67</spage><epage>74</epage><pages>67-74</pages><issn>2296-9837</issn><issn>2296-9845</issn><eissn>2296-9845</eissn><abstract>This work is devoted to studying the reaction of bone tissue to installed titanium implants, which are bioinert in comparison with other metals used in traumatological and orthopedic practice, but which have a negative effect on bone tissue in the implant-to-bone area. In order to increase the affinity of the implant surface with bone tissue, it was proposed to use synthetic bioactive calcium phosphate mineral coating by applying it on titanium implants, which ultimately will make it possible to maintain the quality of the bone tissue around the implant after osteosynthesis or prosthetics. During the comparative research an in vivo experiment was conducted in which quality change of peri-implant zone of bone tissue when using titanium implants with synthetic bioactive calcium phosphate mineral coating and titanium implants without bioactive coating was analyzed. To analyze the results of the study, we used the X-ray computed tomography method, for a detailed assessment of the X-ray density and bone mineral density of the peri-implant zone. According to the results of the experiment, it was concluded that the reaction of bone tissue to synthetic bioactive calcium phosphate mineral coating of titanium implants was reduced, what ensures the preservation of bone tissue quality in the postoperative period at a high level.</abstract><cop>Pfäffikon</cop><pub>Trans Tech Publications Ltd</pub><doi>10.4028/www.scientific.net/JBBBE.46.67</doi><tpages>8</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2296-9837 |
ispartof | Journal of biomimetics, biomaterials and biomedical engineering, 2020-06, Vol.46, p.67-74 |
issn | 2296-9837 2296-9845 2296-9845 |
language | eng |
recordid | cdi_proquest_journals_2414890723 |
source | Scientific.net Journals |
subjects | Biological activity Biomedical materials Bone implants Bone mineral density Bones Calcium phosphates Coating Coatings Computed tomography Metals Orthopedics Osteosynthesis Preservation Prostheses Prosthetics Surgical implants Tissues Titanium Transplants & implants |
title | Preservation of Bone Tissue Quality during the Usage of Synthetic Bioactive Calcium Phosphate Mineral Coating for Prevention of Metallic Construction Migration |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-20T12%3A08%3A39IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Preservation%20of%20Bone%20Tissue%20Quality%20during%20the%20Usage%20of%20Synthetic%20Bioactive%20Calcium%20Phosphate%20Mineral%20Coating%20for%20Prevention%20of%20Metallic%20Construction%20Migration&rft.jtitle=Journal%20of%20biomimetics,%20biomaterials%20and%20biomedical%20engineering&rft.au=Markov,%20Alexander&rft.date=2020-06-01&rft.volume=46&rft.spage=67&rft.epage=74&rft.pages=67-74&rft.issn=2296-9837&rft.eissn=2296-9845&rft_id=info:doi/10.4028/www.scientific.net/JBBBE.46.67&rft_dat=%3Cproquest_cross%3E2414890723%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2414890723&rft_id=info:pmid/&rfr_iscdi=true |