Hybrid Voltage Stability and Security Assessment using Synchrophasors with Consideration of Generator Q-limits

Increased power demands, push for economics and limited investment in grid infrastructure have led utilities to operatepower systems closer to their stability limits. Voltage instability may trigger cascade tripping, wide-area voltage collapse and powerblackouts. Real-time voltage stability monitori...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:arXiv.org 2020-05
Hauptverfasser: Syed Muhammad Hur Rizvi, Kundu, Pratim, Srivastava, Anurag K
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page
container_title arXiv.org
container_volume
creator Syed Muhammad Hur Rizvi
Kundu, Pratim
Srivastava, Anurag K
description Increased power demands, push for economics and limited investment in grid infrastructure have led utilities to operatepower systems closer to their stability limits. Voltage instability may trigger cascade tripping, wide-area voltage collapse and powerblackouts. Real-time voltage stability monitoring possible with deployment of phasor measurement units (PMUs) is essential totake proactive control actions and minimize the impact on system. This paper presents a novel online algorithm for a) hybridperturbation analysis-based voltage stability monitoring (HPVSM), b) including Q-limit in voltage stability index and c) real timesecurity analysis using voltage stability index. HPVSM based voltage stability index is computed using the data obtained fromlinear state estimator and PMU measurements. Typically measurement-based schemes ignore the impact of generator Q-limitsand security analysis is not feasible. The proposed HPVSM based index considers the impact of generator Q-limits violationsby anticipating the critical generators using real-time PMU measurements. Contingencies are ranked using the proposed voltagestability index for security analysis. Results simulated for the 9-bus WECC, IEEE 14, 57 and 118 bus systems highlights thesuperiority of the proposed method in real time voltage stability and security analysis
format Article
fullrecord <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_journals_2407684830</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2407684830</sourcerecordid><originalsourceid>FETCH-proquest_journals_24076848303</originalsourceid><addsrcrecordid>eNqNissKwjAQAIMgKOo_LHguxKTWXkV8XKXiVaJN7Urd1WyK9O9V8AM8DcNMTw2NtbMkT40ZqInITWttsoWZz-1Q0a47ByzhyE10Vw9FdGdsMHbgqITCX9rwlaWIF7l7itAK0hWKji514EfthIPAC2MNKybB0gcXkQm4gq2nr3GAfdLgHaOMVb9yjfjJjyM13awPq13yCPxsvcTTjdtAn3QyqV5keZpbbf-73r4RSwc</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2407684830</pqid></control><display><type>article</type><title>Hybrid Voltage Stability and Security Assessment using Synchrophasors with Consideration of Generator Q-limits</title><source>Free E- Journals</source><creator>Syed Muhammad Hur Rizvi ; Kundu, Pratim ; Srivastava, Anurag K</creator><creatorcontrib>Syed Muhammad Hur Rizvi ; Kundu, Pratim ; Srivastava, Anurag K</creatorcontrib><description>Increased power demands, push for economics and limited investment in grid infrastructure have led utilities to operatepower systems closer to their stability limits. Voltage instability may trigger cascade tripping, wide-area voltage collapse and powerblackouts. Real-time voltage stability monitoring possible with deployment of phasor measurement units (PMUs) is essential totake proactive control actions and minimize the impact on system. This paper presents a novel online algorithm for a) hybridperturbation analysis-based voltage stability monitoring (HPVSM), b) including Q-limit in voltage stability index and c) real timesecurity analysis using voltage stability index. HPVSM based voltage stability index is computed using the data obtained fromlinear state estimator and PMU measurements. Typically measurement-based schemes ignore the impact of generator Q-limitsand security analysis is not feasible. The proposed HPVSM based index considers the impact of generator Q-limits violationsby anticipating the critical generators using real-time PMU measurements. Contingencies are ranked using the proposed voltagestability index for security analysis. Results simulated for the 9-bus WECC, IEEE 14, 57 and 118 bus systems highlights thesuperiority of the proposed method in real time voltage stability and security analysis</description><identifier>EISSN: 2331-8422</identifier><language>eng</language><publisher>Ithaca: Cornell University Library, arXiv.org</publisher><subject>Algorithms ; Computer simulation ; Measuring instruments ; Monitoring ; Real time ; Security ; Stability analysis ; Utilities ; Voltage collapse ; Voltage stability</subject><ispartof>arXiv.org, 2020-05</ispartof><rights>2020. This work is published under http://arxiv.org/licenses/nonexclusive-distrib/1.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>776,780</link.rule.ids></links><search><creatorcontrib>Syed Muhammad Hur Rizvi</creatorcontrib><creatorcontrib>Kundu, Pratim</creatorcontrib><creatorcontrib>Srivastava, Anurag K</creatorcontrib><title>Hybrid Voltage Stability and Security Assessment using Synchrophasors with Consideration of Generator Q-limits</title><title>arXiv.org</title><description>Increased power demands, push for economics and limited investment in grid infrastructure have led utilities to operatepower systems closer to their stability limits. Voltage instability may trigger cascade tripping, wide-area voltage collapse and powerblackouts. Real-time voltage stability monitoring possible with deployment of phasor measurement units (PMUs) is essential totake proactive control actions and minimize the impact on system. This paper presents a novel online algorithm for a) hybridperturbation analysis-based voltage stability monitoring (HPVSM), b) including Q-limit in voltage stability index and c) real timesecurity analysis using voltage stability index. HPVSM based voltage stability index is computed using the data obtained fromlinear state estimator and PMU measurements. Typically measurement-based schemes ignore the impact of generator Q-limitsand security analysis is not feasible. The proposed HPVSM based index considers the impact of generator Q-limits violationsby anticipating the critical generators using real-time PMU measurements. Contingencies are ranked using the proposed voltagestability index for security analysis. Results simulated for the 9-bus WECC, IEEE 14, 57 and 118 bus systems highlights thesuperiority of the proposed method in real time voltage stability and security analysis</description><subject>Algorithms</subject><subject>Computer simulation</subject><subject>Measuring instruments</subject><subject>Monitoring</subject><subject>Real time</subject><subject>Security</subject><subject>Stability analysis</subject><subject>Utilities</subject><subject>Voltage collapse</subject><subject>Voltage stability</subject><issn>2331-8422</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><sourceid>BENPR</sourceid><recordid>eNqNissKwjAQAIMgKOo_LHguxKTWXkV8XKXiVaJN7Urd1WyK9O9V8AM8DcNMTw2NtbMkT40ZqInITWttsoWZz-1Q0a47ByzhyE10Vw9FdGdsMHbgqITCX9rwlaWIF7l7itAK0hWKji514EfthIPAC2MNKybB0gcXkQm4gq2nr3GAfdLgHaOMVb9yjfjJjyM13awPq13yCPxsvcTTjdtAn3QyqV5keZpbbf-73r4RSwc</recordid><startdate>20200527</startdate><enddate>20200527</enddate><creator>Syed Muhammad Hur Rizvi</creator><creator>Kundu, Pratim</creator><creator>Srivastava, Anurag K</creator><general>Cornell University Library, arXiv.org</general><scope>8FE</scope><scope>8FG</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>HCIFZ</scope><scope>L6V</scope><scope>M7S</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PTHSS</scope></search><sort><creationdate>20200527</creationdate><title>Hybrid Voltage Stability and Security Assessment using Synchrophasors with Consideration of Generator Q-limits</title><author>Syed Muhammad Hur Rizvi ; Kundu, Pratim ; Srivastava, Anurag K</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_journals_24076848303</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Algorithms</topic><topic>Computer simulation</topic><topic>Measuring instruments</topic><topic>Monitoring</topic><topic>Real time</topic><topic>Security</topic><topic>Stability analysis</topic><topic>Utilities</topic><topic>Voltage collapse</topic><topic>Voltage stability</topic><toplevel>online_resources</toplevel><creatorcontrib>Syed Muhammad Hur Rizvi</creatorcontrib><creatorcontrib>Kundu, Pratim</creatorcontrib><creatorcontrib>Srivastava, Anurag K</creatorcontrib><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Materials Science &amp; Engineering Collection</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Engineering Collection</collection><collection>Engineering Database</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Engineering Collection</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Syed Muhammad Hur Rizvi</au><au>Kundu, Pratim</au><au>Srivastava, Anurag K</au><format>book</format><genre>document</genre><ristype>GEN</ristype><atitle>Hybrid Voltage Stability and Security Assessment using Synchrophasors with Consideration of Generator Q-limits</atitle><jtitle>arXiv.org</jtitle><date>2020-05-27</date><risdate>2020</risdate><eissn>2331-8422</eissn><abstract>Increased power demands, push for economics and limited investment in grid infrastructure have led utilities to operatepower systems closer to their stability limits. Voltage instability may trigger cascade tripping, wide-area voltage collapse and powerblackouts. Real-time voltage stability monitoring possible with deployment of phasor measurement units (PMUs) is essential totake proactive control actions and minimize the impact on system. This paper presents a novel online algorithm for a) hybridperturbation analysis-based voltage stability monitoring (HPVSM), b) including Q-limit in voltage stability index and c) real timesecurity analysis using voltage stability index. HPVSM based voltage stability index is computed using the data obtained fromlinear state estimator and PMU measurements. Typically measurement-based schemes ignore the impact of generator Q-limitsand security analysis is not feasible. The proposed HPVSM based index considers the impact of generator Q-limits violationsby anticipating the critical generators using real-time PMU measurements. Contingencies are ranked using the proposed voltagestability index for security analysis. Results simulated for the 9-bus WECC, IEEE 14, 57 and 118 bus systems highlights thesuperiority of the proposed method in real time voltage stability and security analysis</abstract><cop>Ithaca</cop><pub>Cornell University Library, arXiv.org</pub><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier EISSN: 2331-8422
ispartof arXiv.org, 2020-05
issn 2331-8422
language eng
recordid cdi_proquest_journals_2407684830
source Free E- Journals
subjects Algorithms
Computer simulation
Measuring instruments
Monitoring
Real time
Security
Stability analysis
Utilities
Voltage collapse
Voltage stability
title Hybrid Voltage Stability and Security Assessment using Synchrophasors with Consideration of Generator Q-limits
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-02T15%3A20%3A30IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=document&rft.atitle=Hybrid%20Voltage%20Stability%20and%20Security%20Assessment%20using%20Synchrophasors%20with%20Consideration%20of%20Generator%20Q-limits&rft.jtitle=arXiv.org&rft.au=Syed%20Muhammad%20Hur%20Rizvi&rft.date=2020-05-27&rft.eissn=2331-8422&rft_id=info:doi/&rft_dat=%3Cproquest%3E2407684830%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2407684830&rft_id=info:pmid/&rfr_iscdi=true