Oligonucleotide Detection and Optical Measurement with Graphene Oxide in the Presence of Bovine Serum Albumin Enabled by Use of Surfactants and Salts

As graphene oxide-based oligonucleotide biosensors improve, there is a growing need to explore their ability to retain high sensitivity for low target concentrations in the context of biological fluids. Therefore, we innovatively combined assay milieu factors that could influence the key performance...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Coatings (Basel) 2020-04, Vol.10 (4), p.420
Hauptverfasser: Nitu, Florentin R., Burns, Jorge S., Ionită, Mariana
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 4
container_start_page 420
container_title Coatings (Basel)
container_volume 10
creator Nitu, Florentin R.
Burns, Jorge S.
Ionită, Mariana
description As graphene oxide-based oligonucleotide biosensors improve, there is a growing need to explore their ability to retain high sensitivity for low target concentrations in the context of biological fluids. Therefore, we innovatively combined assay milieu factors that could influence the key performance parameters of DNA hybridization and graphene oxide (GO) colloid dispersion, verifying their suitability to enhance oligonucleotide–GO interactions and biosensor performance. As a model system, we tested single-strand (ss) DNA detection in a complex solution containing bovine serum albumin (BSA) and salts with surfactants. A fluorescein conjugated 30-mer oligonucleotide ssDNA probe was combined with its complementary cDNA target, together with solute dispersed GO and either non-ionic (Triton X-100 and Tween-20) or anionic sodium dodecyl sulfate (SDS) surfactants. In this context, we compared the effect of divalent Mg2+ or monovalent Na+ salts on GO binding for the quench-based detection of specific target–probe DNA hybridization. GO biosensor strategies for quench-based DNA detection include a “turn on” enhancement of fluorescence upon target–probe interaction versus a “turn off” decreased fluorescence for the GO-bound probe. We found that the sensitive and specific detection of low concentrations of oligonucleotide target was best achieved using a strategy that involved target–probe DNA hybridization in the solution with a subsequent modified “turn-off” GO capture and the quenching of the unhybridized probe. Using carefully formulated assay procedures that prevented GO aggregation, the preferential binding and quenching of the unhybridized probe were both achieved using 0.1% BSA, 0.065% SDS and 6 mM NaCl. This resulted in the sensitive measurement of the specific target–probe complexes remaining in the solution. The fluorescein-conjugated single stranded probe (FAM–ssDNA) exhibited linearity to cDNA hybridization with concentrations in the range of 1–8 nM, with a limit of detection equivalent to 0.1 pmoles of target in 100 µL of assay mix. We highlight a general approach that may be adopted for oligonucleotide target detection within complex solutions.
doi_str_mv 10.3390/coatings10040420
format Article
fullrecord <record><control><sourceid>gale_proqu</sourceid><recordid>TN_cdi_proquest_journals_2395386181</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A631765431</galeid><sourcerecordid>A631765431</sourcerecordid><originalsourceid>FETCH-LOGICAL-c341t-4bec72f6878ce3a82df66ff549fa6383097e881f481792d679acadb44f5e8f573</originalsourceid><addsrcrecordid>eNpdkUFPGzEQhVcIJFDKvUdLnFPstddrHwMNaaWgIKWcV7PecWK0awfbC80P6f9tAkhUncuMNN977_CK4iuj3zjX9NoEyM5vEqNUUFHSk-KipLWeSsHK03_u8-IypSd6GM24Yvqi-LPq3Sb40fQYsuuQfMeMJrvgCfiOrHbZGejJPUIaIw7oM3l1eUsWEXZb9EhWv48q50neInmImNAbJMGSm_DiDv81xnEgs74dhwM099D22JF2Tx7TG7YeowWTwef0lriGPqcvxZmFPuHlx54Uj3fzX7c_psvV4uftbDk1XLA8FS2aurRS1cogB1V2VkprK6EtSK441TUqxaxQrNZlJ2sNBrpWCFuhslXNJ8XVu-8uhucRU26ewhj9IbIpua64kkyxT2oDPTbO25AjmMEl08wkZ7WsBD9S9J0yMaQU0Ta76AaI-4bR5thS839L_C-pMYev</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2395386181</pqid></control><display><type>article</type><title>Oligonucleotide Detection and Optical Measurement with Graphene Oxide in the Presence of Bovine Serum Albumin Enabled by Use of Surfactants and Salts</title><source>MDPI - Multidisciplinary Digital Publishing Institute</source><source>EZB-FREE-00999 freely available EZB journals</source><source>Alma/SFX Local Collection</source><creator>Nitu, Florentin R. ; Burns, Jorge S. ; Ionită, Mariana</creator><creatorcontrib>Nitu, Florentin R. ; Burns, Jorge S. ; Ionită, Mariana</creatorcontrib><description>As graphene oxide-based oligonucleotide biosensors improve, there is a growing need to explore their ability to retain high sensitivity for low target concentrations in the context of biological fluids. Therefore, we innovatively combined assay milieu factors that could influence the key performance parameters of DNA hybridization and graphene oxide (GO) colloid dispersion, verifying their suitability to enhance oligonucleotide–GO interactions and biosensor performance. As a model system, we tested single-strand (ss) DNA detection in a complex solution containing bovine serum albumin (BSA) and salts with surfactants. A fluorescein conjugated 30-mer oligonucleotide ssDNA probe was combined with its complementary cDNA target, together with solute dispersed GO and either non-ionic (Triton X-100 and Tween-20) or anionic sodium dodecyl sulfate (SDS) surfactants. In this context, we compared the effect of divalent Mg2+ or monovalent Na+ salts on GO binding for the quench-based detection of specific target–probe DNA hybridization. GO biosensor strategies for quench-based DNA detection include a “turn on” enhancement of fluorescence upon target–probe interaction versus a “turn off” decreased fluorescence for the GO-bound probe. We found that the sensitive and specific detection of low concentrations of oligonucleotide target was best achieved using a strategy that involved target–probe DNA hybridization in the solution with a subsequent modified “turn-off” GO capture and the quenching of the unhybridized probe. Using carefully formulated assay procedures that prevented GO aggregation, the preferential binding and quenching of the unhybridized probe were both achieved using 0.1% BSA, 0.065% SDS and 6 mM NaCl. This resulted in the sensitive measurement of the specific target–probe complexes remaining in the solution. The fluorescein-conjugated single stranded probe (FAM–ssDNA) exhibited linearity to cDNA hybridization with concentrations in the range of 1–8 nM, with a limit of detection equivalent to 0.1 pmoles of target in 100 µL of assay mix. We highlight a general approach that may be adopted for oligonucleotide target detection within complex solutions.</description><identifier>ISSN: 2079-6412</identifier><identifier>EISSN: 2079-6412</identifier><identifier>DOI: 10.3390/coatings10040420</identifier><language>eng</language><publisher>Basel: MDPI AG</publisher><subject>Assaying ; Binding ; Binding sites ; Biosensors ; Cell culture ; Chemical detectors ; Chemical properties ; Computational fluid dynamics ; Context ; Deoxyribonucleic acid ; Design and construction ; Dispersion ; DNA ; Fluorescein ; Fluorescence ; Graphene ; Linearity ; Low concentrations ; Model testing ; Nanomaterials ; Oligonucleotides ; Optical measurement ; Optical properties ; Pets ; Physiology ; Quenching ; RNA polymerase ; Salts ; Serum albumin ; Sodium ; Sodium dodecyl sulfate ; Surface active agents ; Surfactants ; Target detection</subject><ispartof>Coatings (Basel), 2020-04, Vol.10 (4), p.420</ispartof><rights>COPYRIGHT 2020 MDPI AG</rights><rights>2020. This work is licensed under http://creativecommons.org/licenses/by/3.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c341t-4bec72f6878ce3a82df66ff549fa6383097e881f481792d679acadb44f5e8f573</citedby><cites>FETCH-LOGICAL-c341t-4bec72f6878ce3a82df66ff549fa6383097e881f481792d679acadb44f5e8f573</cites><orcidid>0000-0002-8602-1536</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Nitu, Florentin R.</creatorcontrib><creatorcontrib>Burns, Jorge S.</creatorcontrib><creatorcontrib>Ionită, Mariana</creatorcontrib><title>Oligonucleotide Detection and Optical Measurement with Graphene Oxide in the Presence of Bovine Serum Albumin Enabled by Use of Surfactants and Salts</title><title>Coatings (Basel)</title><description>As graphene oxide-based oligonucleotide biosensors improve, there is a growing need to explore their ability to retain high sensitivity for low target concentrations in the context of biological fluids. Therefore, we innovatively combined assay milieu factors that could influence the key performance parameters of DNA hybridization and graphene oxide (GO) colloid dispersion, verifying their suitability to enhance oligonucleotide–GO interactions and biosensor performance. As a model system, we tested single-strand (ss) DNA detection in a complex solution containing bovine serum albumin (BSA) and salts with surfactants. A fluorescein conjugated 30-mer oligonucleotide ssDNA probe was combined with its complementary cDNA target, together with solute dispersed GO and either non-ionic (Triton X-100 and Tween-20) or anionic sodium dodecyl sulfate (SDS) surfactants. In this context, we compared the effect of divalent Mg2+ or monovalent Na+ salts on GO binding for the quench-based detection of specific target–probe DNA hybridization. GO biosensor strategies for quench-based DNA detection include a “turn on” enhancement of fluorescence upon target–probe interaction versus a “turn off” decreased fluorescence for the GO-bound probe. We found that the sensitive and specific detection of low concentrations of oligonucleotide target was best achieved using a strategy that involved target–probe DNA hybridization in the solution with a subsequent modified “turn-off” GO capture and the quenching of the unhybridized probe. Using carefully formulated assay procedures that prevented GO aggregation, the preferential binding and quenching of the unhybridized probe were both achieved using 0.1% BSA, 0.065% SDS and 6 mM NaCl. This resulted in the sensitive measurement of the specific target–probe complexes remaining in the solution. The fluorescein-conjugated single stranded probe (FAM–ssDNA) exhibited linearity to cDNA hybridization with concentrations in the range of 1–8 nM, with a limit of detection equivalent to 0.1 pmoles of target in 100 µL of assay mix. We highlight a general approach that may be adopted for oligonucleotide target detection within complex solutions.</description><subject>Assaying</subject><subject>Binding</subject><subject>Binding sites</subject><subject>Biosensors</subject><subject>Cell culture</subject><subject>Chemical detectors</subject><subject>Chemical properties</subject><subject>Computational fluid dynamics</subject><subject>Context</subject><subject>Deoxyribonucleic acid</subject><subject>Design and construction</subject><subject>Dispersion</subject><subject>DNA</subject><subject>Fluorescein</subject><subject>Fluorescence</subject><subject>Graphene</subject><subject>Linearity</subject><subject>Low concentrations</subject><subject>Model testing</subject><subject>Nanomaterials</subject><subject>Oligonucleotides</subject><subject>Optical measurement</subject><subject>Optical properties</subject><subject>Pets</subject><subject>Physiology</subject><subject>Quenching</subject><subject>RNA polymerase</subject><subject>Salts</subject><subject>Serum albumin</subject><subject>Sodium</subject><subject>Sodium dodecyl sulfate</subject><subject>Surface active agents</subject><subject>Surfactants</subject><subject>Target detection</subject><issn>2079-6412</issn><issn>2079-6412</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><recordid>eNpdkUFPGzEQhVcIJFDKvUdLnFPstddrHwMNaaWgIKWcV7PecWK0awfbC80P6f9tAkhUncuMNN977_CK4iuj3zjX9NoEyM5vEqNUUFHSk-KipLWeSsHK03_u8-IypSd6GM24Yvqi-LPq3Sb40fQYsuuQfMeMJrvgCfiOrHbZGejJPUIaIw7oM3l1eUsWEXZb9EhWv48q50neInmImNAbJMGSm_DiDv81xnEgs74dhwM099D22JF2Tx7TG7YeowWTwef0lriGPqcvxZmFPuHlx54Uj3fzX7c_psvV4uftbDk1XLA8FS2aurRS1cogB1V2VkprK6EtSK441TUqxaxQrNZlJ2sNBrpWCFuhslXNJ8XVu-8uhucRU26ewhj9IbIpua64kkyxT2oDPTbO25AjmMEl08wkZ7WsBD9S9J0yMaQU0Ta76AaI-4bR5thS839L_C-pMYev</recordid><startdate>20200401</startdate><enddate>20200401</enddate><creator>Nitu, Florentin R.</creator><creator>Burns, Jorge S.</creator><creator>Ionită, Mariana</creator><general>MDPI AG</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SR</scope><scope>8BQ</scope><scope>8FD</scope><scope>8FE</scope><scope>8FG</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>D1I</scope><scope>DWQXO</scope><scope>HCIFZ</scope><scope>JG9</scope><scope>KB.</scope><scope>PDBOC</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><orcidid>https://orcid.org/0000-0002-8602-1536</orcidid></search><sort><creationdate>20200401</creationdate><title>Oligonucleotide Detection and Optical Measurement with Graphene Oxide in the Presence of Bovine Serum Albumin Enabled by Use of Surfactants and Salts</title><author>Nitu, Florentin R. ; Burns, Jorge S. ; Ionită, Mariana</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c341t-4bec72f6878ce3a82df66ff549fa6383097e881f481792d679acadb44f5e8f573</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Assaying</topic><topic>Binding</topic><topic>Binding sites</topic><topic>Biosensors</topic><topic>Cell culture</topic><topic>Chemical detectors</topic><topic>Chemical properties</topic><topic>Computational fluid dynamics</topic><topic>Context</topic><topic>Deoxyribonucleic acid</topic><topic>Design and construction</topic><topic>Dispersion</topic><topic>DNA</topic><topic>Fluorescein</topic><topic>Fluorescence</topic><topic>Graphene</topic><topic>Linearity</topic><topic>Low concentrations</topic><topic>Model testing</topic><topic>Nanomaterials</topic><topic>Oligonucleotides</topic><topic>Optical measurement</topic><topic>Optical properties</topic><topic>Pets</topic><topic>Physiology</topic><topic>Quenching</topic><topic>RNA polymerase</topic><topic>Salts</topic><topic>Serum albumin</topic><topic>Sodium</topic><topic>Sodium dodecyl sulfate</topic><topic>Surface active agents</topic><topic>Surfactants</topic><topic>Target detection</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Nitu, Florentin R.</creatorcontrib><creatorcontrib>Burns, Jorge S.</creatorcontrib><creatorcontrib>Ionită, Mariana</creatorcontrib><collection>CrossRef</collection><collection>Engineered Materials Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Materials Science &amp; Engineering Collection</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Materials Science Collection</collection><collection>ProQuest Central Korea</collection><collection>SciTech Premium Collection</collection><collection>Materials Research Database</collection><collection>Materials Science Database</collection><collection>Materials Science Collection</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><jtitle>Coatings (Basel)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Nitu, Florentin R.</au><au>Burns, Jorge S.</au><au>Ionită, Mariana</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Oligonucleotide Detection and Optical Measurement with Graphene Oxide in the Presence of Bovine Serum Albumin Enabled by Use of Surfactants and Salts</atitle><jtitle>Coatings (Basel)</jtitle><date>2020-04-01</date><risdate>2020</risdate><volume>10</volume><issue>4</issue><spage>420</spage><pages>420-</pages><issn>2079-6412</issn><eissn>2079-6412</eissn><abstract>As graphene oxide-based oligonucleotide biosensors improve, there is a growing need to explore their ability to retain high sensitivity for low target concentrations in the context of biological fluids. Therefore, we innovatively combined assay milieu factors that could influence the key performance parameters of DNA hybridization and graphene oxide (GO) colloid dispersion, verifying their suitability to enhance oligonucleotide–GO interactions and biosensor performance. As a model system, we tested single-strand (ss) DNA detection in a complex solution containing bovine serum albumin (BSA) and salts with surfactants. A fluorescein conjugated 30-mer oligonucleotide ssDNA probe was combined with its complementary cDNA target, together with solute dispersed GO and either non-ionic (Triton X-100 and Tween-20) or anionic sodium dodecyl sulfate (SDS) surfactants. In this context, we compared the effect of divalent Mg2+ or monovalent Na+ salts on GO binding for the quench-based detection of specific target–probe DNA hybridization. GO biosensor strategies for quench-based DNA detection include a “turn on” enhancement of fluorescence upon target–probe interaction versus a “turn off” decreased fluorescence for the GO-bound probe. We found that the sensitive and specific detection of low concentrations of oligonucleotide target was best achieved using a strategy that involved target–probe DNA hybridization in the solution with a subsequent modified “turn-off” GO capture and the quenching of the unhybridized probe. Using carefully formulated assay procedures that prevented GO aggregation, the preferential binding and quenching of the unhybridized probe were both achieved using 0.1% BSA, 0.065% SDS and 6 mM NaCl. This resulted in the sensitive measurement of the specific target–probe complexes remaining in the solution. The fluorescein-conjugated single stranded probe (FAM–ssDNA) exhibited linearity to cDNA hybridization with concentrations in the range of 1–8 nM, with a limit of detection equivalent to 0.1 pmoles of target in 100 µL of assay mix. We highlight a general approach that may be adopted for oligonucleotide target detection within complex solutions.</abstract><cop>Basel</cop><pub>MDPI AG</pub><doi>10.3390/coatings10040420</doi><orcidid>https://orcid.org/0000-0002-8602-1536</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2079-6412
ispartof Coatings (Basel), 2020-04, Vol.10 (4), p.420
issn 2079-6412
2079-6412
language eng
recordid cdi_proquest_journals_2395386181
source MDPI - Multidisciplinary Digital Publishing Institute; EZB-FREE-00999 freely available EZB journals; Alma/SFX Local Collection
subjects Assaying
Binding
Binding sites
Biosensors
Cell culture
Chemical detectors
Chemical properties
Computational fluid dynamics
Context
Deoxyribonucleic acid
Design and construction
Dispersion
DNA
Fluorescein
Fluorescence
Graphene
Linearity
Low concentrations
Model testing
Nanomaterials
Oligonucleotides
Optical measurement
Optical properties
Pets
Physiology
Quenching
RNA polymerase
Salts
Serum albumin
Sodium
Sodium dodecyl sulfate
Surface active agents
Surfactants
Target detection
title Oligonucleotide Detection and Optical Measurement with Graphene Oxide in the Presence of Bovine Serum Albumin Enabled by Use of Surfactants and Salts
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-01T02%3A23%3A01IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale_proqu&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Oligonucleotide%20Detection%20and%20Optical%20Measurement%20with%20Graphene%20Oxide%20in%20the%20Presence%20of%20Bovine%20Serum%20Albumin%20Enabled%20by%20Use%20of%20Surfactants%20and%20Salts&rft.jtitle=Coatings%20(Basel)&rft.au=Nitu,%20Florentin%20R.&rft.date=2020-04-01&rft.volume=10&rft.issue=4&rft.spage=420&rft.pages=420-&rft.issn=2079-6412&rft.eissn=2079-6412&rft_id=info:doi/10.3390/coatings10040420&rft_dat=%3Cgale_proqu%3EA631765431%3C/gale_proqu%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2395386181&rft_id=info:pmid/&rft_galeid=A631765431&rfr_iscdi=true