Errors in Intra- and Inter-rater Measurements of Lower Limb Muscle Strength Using a Handheld Dynamometer

[Purpose] The purpose of this study was to verify the magnitude of errors in muscle strength measurement using a handheld dynamometer (HHD). [Participants and Methods] The study participants were 16 healthy adults (32 limbs). A HHD was used to measure lower limb muscle strength, including hip flexio...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Rigaku ryoho kagaku 2020, Vol.35(2), pp.209-215
Hauptverfasser: SUZUKI, Yoshikazu, ICHIKAWA, Takafumi, KAMIDE, Naoto, MATOBA, Erika, NAKAZONO, Tetsuharu, FUJIHASHI, Noriyuki, HIRAGA, Yoshimi, FUKUDA, Michinari
Format: Artikel
Sprache:eng ; jpn
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 215
container_issue 2
container_start_page 209
container_title Rigaku ryoho kagaku
container_volume 35
creator SUZUKI, Yoshikazu
ICHIKAWA, Takafumi
KAMIDE, Naoto
MATOBA, Erika
NAKAZONO, Tetsuharu
FUJIHASHI, Noriyuki
HIRAGA, Yoshimi
FUKUDA, Michinari
description [Purpose] The purpose of this study was to verify the magnitude of errors in muscle strength measurement using a handheld dynamometer (HHD). [Participants and Methods] The study participants were 16 healthy adults (32 limbs). A HHD was used to measure lower limb muscle strength, including hip flexion, extension, abduction, adduction and knee extension. Each measurement was performed two times by two experienced raters to verify the magnitude of errors in intra- and inter-rater measurements. The errors for each measurement were estimated using the % minimum detectable change (%MDC). [Results] The error in intra-rater measurements of hip adduction was within “acceptable” limits. The errors in inter-rater measurements of hip abduction and adduction exceeded “acceptable” limits. The errors of the other items were “acceptable”. [Conclusion] When muscle strength is measured using an HHD, careful attention should be paid to the magnitude of errors found in this study.
doi_str_mv 10.1589/rika.35.209
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2394978801</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2394978801</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2269-8406830431776f3bf3579497baa0348b85619d453edb440e0db5a9563c38d0643</originalsourceid><addsrcrecordid>eNpFkF1LwzAUhoMoOOau_AMBL6UzaT6a3ggypxt0eKG7Dmmbbp1rOk9aZP_elI15kxPOec5z4EXonpIpFSp9gvrbTJmYxiS9QqOYMx7FiiTXaEQZpxGVMrlFE-_rnHCeiDRRcoS2c4AWPK4dXroOTISNK4evhQhMePHKGt-DbazrPG4rnLW_oZvVTY5XvS_2Fn92YN2m2-K1r90GG7wIjq3dl_j16EzTNjZ47tBNZfbeTs51jNZv86_ZIso-3pezlywq4limkeJEKkY4o0kiK5ZXTCQpT5PcGMK4ypWQNC25YLbMOSeWlLkwqZCsYKokkrMxejh5D9D-9NZ3etf24MJJHbPBpBShgXo8UQW03oOt9AHqxsBRU6KHNPWQpmZChzQD_Xyid74zG3thDXR1COCfPS9cBsXWgLaO_QFnKn2B</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2394978801</pqid></control><display><type>article</type><title>Errors in Intra- and Inter-rater Measurements of Lower Limb Muscle Strength Using a Handheld Dynamometer</title><source>J-STAGE (Japan Science &amp; Technology Information Aggregator, Electronic) Freely Available Titles - Japanese</source><source>EZB-FREE-00999 freely available EZB journals</source><creator>SUZUKI, Yoshikazu ; ICHIKAWA, Takafumi ; KAMIDE, Naoto ; MATOBA, Erika ; NAKAZONO, Tetsuharu ; FUJIHASHI, Noriyuki ; HIRAGA, Yoshimi ; FUKUDA, Michinari</creator><creatorcontrib>SUZUKI, Yoshikazu ; ICHIKAWA, Takafumi ; KAMIDE, Naoto ; MATOBA, Erika ; NAKAZONO, Tetsuharu ; FUJIHASHI, Noriyuki ; HIRAGA, Yoshimi ; FUKUDA, Michinari</creatorcontrib><description>[Purpose] The purpose of this study was to verify the magnitude of errors in muscle strength measurement using a handheld dynamometer (HHD). [Participants and Methods] The study participants were 16 healthy adults (32 limbs). A HHD was used to measure lower limb muscle strength, including hip flexion, extension, abduction, adduction and knee extension. Each measurement was performed two times by two experienced raters to verify the magnitude of errors in intra- and inter-rater measurements. The errors for each measurement were estimated using the % minimum detectable change (%MDC). [Results] The error in intra-rater measurements of hip adduction was within “acceptable” limits. The errors in inter-rater measurements of hip abduction and adduction exceeded “acceptable” limits. The errors of the other items were “acceptable”. [Conclusion] When muscle strength is measured using an HHD, careful attention should be paid to the magnitude of errors found in this study.</description><identifier>ISSN: 1341-1667</identifier><identifier>EISSN: 2434-2807</identifier><identifier>DOI: 10.1589/rika.35.209</identifier><language>eng ; jpn</language><publisher>Tokyo: The Society of Physical Therapy Science</publisher><subject>handheld dynamometer ; Hands ; measurement error ; Muscle strength ; muscle strength measurement</subject><ispartof>Rigakuryoho Kagaku, 2020, Vol.35(2), pp.209-215</ispartof><rights>2020 by the Society of Physical Therapy Science</rights><rights>2020. This work is published under https://creativecommons.org/licenses/by-nc-nd/4.0/deed.ja (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c2269-8406830431776f3bf3579497baa0348b85619d453edb440e0db5a9563c38d0643</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,1877,4010,27900,27901,27902</link.rule.ids></links><search><creatorcontrib>SUZUKI, Yoshikazu</creatorcontrib><creatorcontrib>ICHIKAWA, Takafumi</creatorcontrib><creatorcontrib>KAMIDE, Naoto</creatorcontrib><creatorcontrib>MATOBA, Erika</creatorcontrib><creatorcontrib>NAKAZONO, Tetsuharu</creatorcontrib><creatorcontrib>FUJIHASHI, Noriyuki</creatorcontrib><creatorcontrib>HIRAGA, Yoshimi</creatorcontrib><creatorcontrib>FUKUDA, Michinari</creatorcontrib><title>Errors in Intra- and Inter-rater Measurements of Lower Limb Muscle Strength Using a Handheld Dynamometer</title><title>Rigaku ryoho kagaku</title><addtitle>Rigakuryoho Kagaku</addtitle><description>[Purpose] The purpose of this study was to verify the magnitude of errors in muscle strength measurement using a handheld dynamometer (HHD). [Participants and Methods] The study participants were 16 healthy adults (32 limbs). A HHD was used to measure lower limb muscle strength, including hip flexion, extension, abduction, adduction and knee extension. Each measurement was performed two times by two experienced raters to verify the magnitude of errors in intra- and inter-rater measurements. The errors for each measurement were estimated using the % minimum detectable change (%MDC). [Results] The error in intra-rater measurements of hip adduction was within “acceptable” limits. The errors in inter-rater measurements of hip abduction and adduction exceeded “acceptable” limits. The errors of the other items were “acceptable”. [Conclusion] When muscle strength is measured using an HHD, careful attention should be paid to the magnitude of errors found in this study.</description><subject>handheld dynamometer</subject><subject>Hands</subject><subject>measurement error</subject><subject>Muscle strength</subject><subject>muscle strength measurement</subject><issn>1341-1667</issn><issn>2434-2807</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNpFkF1LwzAUhoMoOOau_AMBL6UzaT6a3ggypxt0eKG7Dmmbbp1rOk9aZP_elI15kxPOec5z4EXonpIpFSp9gvrbTJmYxiS9QqOYMx7FiiTXaEQZpxGVMrlFE-_rnHCeiDRRcoS2c4AWPK4dXroOTISNK4evhQhMePHKGt-DbazrPG4rnLW_oZvVTY5XvS_2Fn92YN2m2-K1r90GG7wIjq3dl_j16EzTNjZ47tBNZfbeTs51jNZv86_ZIso-3pezlywq4limkeJEKkY4o0kiK5ZXTCQpT5PcGMK4ypWQNC25YLbMOSeWlLkwqZCsYKokkrMxejh5D9D-9NZ3etf24MJJHbPBpBShgXo8UQW03oOt9AHqxsBRU6KHNPWQpmZChzQD_Xyid74zG3thDXR1COCfPS9cBsXWgLaO_QFnKn2B</recordid><startdate>2020</startdate><enddate>2020</enddate><creator>SUZUKI, Yoshikazu</creator><creator>ICHIKAWA, Takafumi</creator><creator>KAMIDE, Naoto</creator><creator>MATOBA, Erika</creator><creator>NAKAZONO, Tetsuharu</creator><creator>FUJIHASHI, Noriyuki</creator><creator>HIRAGA, Yoshimi</creator><creator>FUKUDA, Michinari</creator><general>The Society of Physical Therapy Science</general><general>Japan Science and Technology Agency</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7TS</scope></search><sort><creationdate>2020</creationdate><title>Errors in Intra- and Inter-rater Measurements of Lower Limb Muscle Strength Using a Handheld Dynamometer</title><author>SUZUKI, Yoshikazu ; ICHIKAWA, Takafumi ; KAMIDE, Naoto ; MATOBA, Erika ; NAKAZONO, Tetsuharu ; FUJIHASHI, Noriyuki ; HIRAGA, Yoshimi ; FUKUDA, Michinari</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2269-8406830431776f3bf3579497baa0348b85619d453edb440e0db5a9563c38d0643</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng ; jpn</language><creationdate>2020</creationdate><topic>handheld dynamometer</topic><topic>Hands</topic><topic>measurement error</topic><topic>Muscle strength</topic><topic>muscle strength measurement</topic><toplevel>online_resources</toplevel><creatorcontrib>SUZUKI, Yoshikazu</creatorcontrib><creatorcontrib>ICHIKAWA, Takafumi</creatorcontrib><creatorcontrib>KAMIDE, Naoto</creatorcontrib><creatorcontrib>MATOBA, Erika</creatorcontrib><creatorcontrib>NAKAZONO, Tetsuharu</creatorcontrib><creatorcontrib>FUJIHASHI, Noriyuki</creatorcontrib><creatorcontrib>HIRAGA, Yoshimi</creatorcontrib><creatorcontrib>FUKUDA, Michinari</creatorcontrib><collection>CrossRef</collection><collection>Physical Education Index</collection><jtitle>Rigaku ryoho kagaku</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>SUZUKI, Yoshikazu</au><au>ICHIKAWA, Takafumi</au><au>KAMIDE, Naoto</au><au>MATOBA, Erika</au><au>NAKAZONO, Tetsuharu</au><au>FUJIHASHI, Noriyuki</au><au>HIRAGA, Yoshimi</au><au>FUKUDA, Michinari</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Errors in Intra- and Inter-rater Measurements of Lower Limb Muscle Strength Using a Handheld Dynamometer</atitle><jtitle>Rigaku ryoho kagaku</jtitle><addtitle>Rigakuryoho Kagaku</addtitle><date>2020</date><risdate>2020</risdate><volume>35</volume><issue>2</issue><spage>209</spage><epage>215</epage><pages>209-215</pages><issn>1341-1667</issn><eissn>2434-2807</eissn><abstract>[Purpose] The purpose of this study was to verify the magnitude of errors in muscle strength measurement using a handheld dynamometer (HHD). [Participants and Methods] The study participants were 16 healthy adults (32 limbs). A HHD was used to measure lower limb muscle strength, including hip flexion, extension, abduction, adduction and knee extension. Each measurement was performed two times by two experienced raters to verify the magnitude of errors in intra- and inter-rater measurements. The errors for each measurement were estimated using the % minimum detectable change (%MDC). [Results] The error in intra-rater measurements of hip adduction was within “acceptable” limits. The errors in inter-rater measurements of hip abduction and adduction exceeded “acceptable” limits. The errors of the other items were “acceptable”. [Conclusion] When muscle strength is measured using an HHD, careful attention should be paid to the magnitude of errors found in this study.</abstract><cop>Tokyo</cop><pub>The Society of Physical Therapy Science</pub><doi>10.1589/rika.35.209</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1341-1667
ispartof Rigakuryoho Kagaku, 2020, Vol.35(2), pp.209-215
issn 1341-1667
2434-2807
language eng ; jpn
recordid cdi_proquest_journals_2394978801
source J-STAGE (Japan Science & Technology Information Aggregator, Electronic) Freely Available Titles - Japanese; EZB-FREE-00999 freely available EZB journals
subjects handheld dynamometer
Hands
measurement error
Muscle strength
muscle strength measurement
title Errors in Intra- and Inter-rater Measurements of Lower Limb Muscle Strength Using a Handheld Dynamometer
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-10T06%3A13%3A44IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Errors%20in%20Intra-%20and%20Inter-rater%20Measurements%20of%20Lower%20Limb%20Muscle%20Strength%20Using%20a%20Handheld%20Dynamometer&rft.jtitle=Rigaku%20ryoho%20kagaku&rft.au=SUZUKI,%20Yoshikazu&rft.date=2020&rft.volume=35&rft.issue=2&rft.spage=209&rft.epage=215&rft.pages=209-215&rft.issn=1341-1667&rft.eissn=2434-2807&rft_id=info:doi/10.1589/rika.35.209&rft_dat=%3Cproquest_cross%3E2394978801%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2394978801&rft_id=info:pmid/&rfr_iscdi=true