Phospholipid modified glassy carbon electrode for determination of chili peppers pungency by ex-situ extraction voltammetry
Objective determination of chili peppers pungency, for which capsaicinoids (CPDs), predominantly capsaicin (CA) and dihydrocapsaicin (DHC) are responsible, belongs to frequently solved tasks in food and medicinal analysis. In this manuscript, application of ex-situ extractive stripping voltammetry (...
Gespeichert in:
Veröffentlicht in: | Journal of electroanalytical chemistry (Lausanne, Switzerland) Switzerland), 2020-02, Vol.858, p.113790, Article 113790 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | |
container_start_page | 113790 |
container_title | Journal of electroanalytical chemistry (Lausanne, Switzerland) |
container_volume | 858 |
creator | Jerga, Radek Rajcová, Andrea Müllerová, Veronika Barták, Petr Cankař, Petr Navrátil, Tomáš Skopalová, Jana |
description | Objective determination of chili peppers pungency, for which capsaicinoids (CPDs), predominantly capsaicin (CA) and dihydrocapsaicin (DHC) are responsible, belongs to frequently solved tasks in food and medicinal analysis. In this manuscript, application of ex-situ extractive stripping voltammetry (ExSV) utilizing a phospholipid modified glassy carbon electrode is described.
The obtained analytical parameters, e.g., linear dynamic range from 3 to 60 mg L−1, limit of detection 2.1 mg L−1, proved to be fully comparable with those achieved using the direct voltammetric method on a polished glassy carbon electrode and reference HPLC/UV. Although the sensitivity of ExSV was slightly lower compared to the direct method, ExSV provided better selectivity to CPDs due to their lipophilic interactions with the phospholipid layer. Hydrophilic components of the chili pepper samples were not extracted into the phospholipid layer and therefore did not interfere. The developed method was tested on the determination of CPDs in different chili peppers: Foxta, Madras Chilli, Habanero, Carolina Reaper, Bird's eye, Bhut Jolokia, Naga Jolokia extract, and Habanero extract.
Furthermore, the electrochemical reactions of CPDs in acidic aqueous-methanolic media were characterized using an electrochemical cell hyphenated with mass spectrometer and the main oxidation products were identified.
•Phospholipid layer on glassy carbon electrode allows extraction of capsaicinoids.•Extraction improves selectivity and linear range of voltammetric determination.•Ex-situ extraction method was used for determination of chili peppers pungency.•Results accord with HPLC and direct voltammetric method on bare electrode. |
doi_str_mv | 10.1016/j.jelechem.2019.113790 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2376945180</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1572665719310586</els_id><sourcerecordid>2376945180</sourcerecordid><originalsourceid>FETCH-LOGICAL-c340t-2d59205c3049c20bb90176dbd8915e43db02c583f5e0009b6c055ec5e3c4e1e3</originalsourceid><addsrcrecordid>eNqFkEtLxTAQhYso-PwLEnDd6yRp2maniC8QdOE-tMnUm9I2NckVi3_eXK-uXZ2BOecM82XZOYUVBVpe9qseB9RrHFcMqFxRyisJe9kRrSueM1HK_TSLiuVlKarD7DiEHoDVNWVH2dfL2oV57QY7W0NGZ2xn0ZC3oQlhIbrxrZvItj56Z5B0zhODEf1opybatHMd0Ws7WDLjPKMPZN5MbzjphbQLwc882LhJGn2jf_wfbojNOGL0y2l20DVDwLNfPcle725fbx7yp-f7x5vrp1zzAmLOjJAMhOZQSM2gbSXQqjStqSUVWHDTAtOi5p1AAJBtqUEI1AK5LpAiP8kudrWzd-8bDFH1buOndFExXpWyELSG5Cp3Lu1dCB47NXs7Nn5RFNSWs-rVH2e15ax2nFPwahfE9MKHRa-CtgkAGusTNmWc_a_iGwFAjKg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2376945180</pqid></control><display><type>article</type><title>Phospholipid modified glassy carbon electrode for determination of chili peppers pungency by ex-situ extraction voltammetry</title><source>Elsevier ScienceDirect Journals</source><creator>Jerga, Radek ; Rajcová, Andrea ; Müllerová, Veronika ; Barták, Petr ; Cankař, Petr ; Navrátil, Tomáš ; Skopalová, Jana</creator><creatorcontrib>Jerga, Radek ; Rajcová, Andrea ; Müllerová, Veronika ; Barták, Petr ; Cankař, Petr ; Navrátil, Tomáš ; Skopalová, Jana</creatorcontrib><description>Objective determination of chili peppers pungency, for which capsaicinoids (CPDs), predominantly capsaicin (CA) and dihydrocapsaicin (DHC) are responsible, belongs to frequently solved tasks in food and medicinal analysis. In this manuscript, application of ex-situ extractive stripping voltammetry (ExSV) utilizing a phospholipid modified glassy carbon electrode is described.
The obtained analytical parameters, e.g., linear dynamic range from 3 to 60 mg L−1, limit of detection 2.1 mg L−1, proved to be fully comparable with those achieved using the direct voltammetric method on a polished glassy carbon electrode and reference HPLC/UV. Although the sensitivity of ExSV was slightly lower compared to the direct method, ExSV provided better selectivity to CPDs due to their lipophilic interactions with the phospholipid layer. Hydrophilic components of the chili pepper samples were not extracted into the phospholipid layer and therefore did not interfere. The developed method was tested on the determination of CPDs in different chili peppers: Foxta, Madras Chilli, Habanero, Carolina Reaper, Bird's eye, Bhut Jolokia, Naga Jolokia extract, and Habanero extract.
Furthermore, the electrochemical reactions of CPDs in acidic aqueous-methanolic media were characterized using an electrochemical cell hyphenated with mass spectrometer and the main oxidation products were identified.
•Phospholipid layer on glassy carbon electrode allows extraction of capsaicinoids.•Extraction improves selectivity and linear range of voltammetric determination.•Ex-situ extraction method was used for determination of chili peppers pungency.•Results accord with HPLC and direct voltammetric method on bare electrode.</description><identifier>ISSN: 1572-6657</identifier><identifier>EISSN: 1873-2569</identifier><identifier>DOI: 10.1016/j.jelechem.2019.113790</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Asolectin ; Capsaicinoids ; Carbon ; Chemical reactions ; Chili peppers ; Electrochemical cells ; Electrochemical oxidation products ; Electrodes ; Extractive stripping voltammetry ; Glassy carbon ; Oxidation ; Parameter modification ; Peppers ; Phospholipid modified electrode ; Phospholipids ; Selectivity ; Voltammetry</subject><ispartof>Journal of electroanalytical chemistry (Lausanne, Switzerland), 2020-02, Vol.858, p.113790, Article 113790</ispartof><rights>2020 Elsevier B.V.</rights><rights>Copyright Elsevier Science Ltd. Feb 1, 2020</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c340t-2d59205c3049c20bb90176dbd8915e43db02c583f5e0009b6c055ec5e3c4e1e3</citedby><cites>FETCH-LOGICAL-c340t-2d59205c3049c20bb90176dbd8915e43db02c583f5e0009b6c055ec5e3c4e1e3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S1572665719310586$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids></links><search><creatorcontrib>Jerga, Radek</creatorcontrib><creatorcontrib>Rajcová, Andrea</creatorcontrib><creatorcontrib>Müllerová, Veronika</creatorcontrib><creatorcontrib>Barták, Petr</creatorcontrib><creatorcontrib>Cankař, Petr</creatorcontrib><creatorcontrib>Navrátil, Tomáš</creatorcontrib><creatorcontrib>Skopalová, Jana</creatorcontrib><title>Phospholipid modified glassy carbon electrode for determination of chili peppers pungency by ex-situ extraction voltammetry</title><title>Journal of electroanalytical chemistry (Lausanne, Switzerland)</title><description>Objective determination of chili peppers pungency, for which capsaicinoids (CPDs), predominantly capsaicin (CA) and dihydrocapsaicin (DHC) are responsible, belongs to frequently solved tasks in food and medicinal analysis. In this manuscript, application of ex-situ extractive stripping voltammetry (ExSV) utilizing a phospholipid modified glassy carbon electrode is described.
The obtained analytical parameters, e.g., linear dynamic range from 3 to 60 mg L−1, limit of detection 2.1 mg L−1, proved to be fully comparable with those achieved using the direct voltammetric method on a polished glassy carbon electrode and reference HPLC/UV. Although the sensitivity of ExSV was slightly lower compared to the direct method, ExSV provided better selectivity to CPDs due to their lipophilic interactions with the phospholipid layer. Hydrophilic components of the chili pepper samples were not extracted into the phospholipid layer and therefore did not interfere. The developed method was tested on the determination of CPDs in different chili peppers: Foxta, Madras Chilli, Habanero, Carolina Reaper, Bird's eye, Bhut Jolokia, Naga Jolokia extract, and Habanero extract.
Furthermore, the electrochemical reactions of CPDs in acidic aqueous-methanolic media were characterized using an electrochemical cell hyphenated with mass spectrometer and the main oxidation products were identified.
•Phospholipid layer on glassy carbon electrode allows extraction of capsaicinoids.•Extraction improves selectivity and linear range of voltammetric determination.•Ex-situ extraction method was used for determination of chili peppers pungency.•Results accord with HPLC and direct voltammetric method on bare electrode.</description><subject>Asolectin</subject><subject>Capsaicinoids</subject><subject>Carbon</subject><subject>Chemical reactions</subject><subject>Chili peppers</subject><subject>Electrochemical cells</subject><subject>Electrochemical oxidation products</subject><subject>Electrodes</subject><subject>Extractive stripping voltammetry</subject><subject>Glassy carbon</subject><subject>Oxidation</subject><subject>Parameter modification</subject><subject>Peppers</subject><subject>Phospholipid modified electrode</subject><subject>Phospholipids</subject><subject>Selectivity</subject><subject>Voltammetry</subject><issn>1572-6657</issn><issn>1873-2569</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNqFkEtLxTAQhYso-PwLEnDd6yRp2maniC8QdOE-tMnUm9I2NckVi3_eXK-uXZ2BOecM82XZOYUVBVpe9qseB9RrHFcMqFxRyisJe9kRrSueM1HK_TSLiuVlKarD7DiEHoDVNWVH2dfL2oV57QY7W0NGZ2xn0ZC3oQlhIbrxrZvItj56Z5B0zhODEf1opybatHMd0Ws7WDLjPKMPZN5MbzjphbQLwc882LhJGn2jf_wfbojNOGL0y2l20DVDwLNfPcle725fbx7yp-f7x5vrp1zzAmLOjJAMhOZQSM2gbSXQqjStqSUVWHDTAtOi5p1AAJBtqUEI1AK5LpAiP8kudrWzd-8bDFH1buOndFExXpWyELSG5Cp3Lu1dCB47NXs7Nn5RFNSWs-rVH2e15ax2nFPwahfE9MKHRa-CtgkAGusTNmWc_a_iGwFAjKg</recordid><startdate>20200201</startdate><enddate>20200201</enddate><creator>Jerga, Radek</creator><creator>Rajcová, Andrea</creator><creator>Müllerová, Veronika</creator><creator>Barták, Petr</creator><creator>Cankař, Petr</creator><creator>Navrátil, Tomáš</creator><creator>Skopalová, Jana</creator><general>Elsevier B.V</general><general>Elsevier Science Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SR</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope></search><sort><creationdate>20200201</creationdate><title>Phospholipid modified glassy carbon electrode for determination of chili peppers pungency by ex-situ extraction voltammetry</title><author>Jerga, Radek ; Rajcová, Andrea ; Müllerová, Veronika ; Barták, Petr ; Cankař, Petr ; Navrátil, Tomáš ; Skopalová, Jana</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c340t-2d59205c3049c20bb90176dbd8915e43db02c583f5e0009b6c055ec5e3c4e1e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Asolectin</topic><topic>Capsaicinoids</topic><topic>Carbon</topic><topic>Chemical reactions</topic><topic>Chili peppers</topic><topic>Electrochemical cells</topic><topic>Electrochemical oxidation products</topic><topic>Electrodes</topic><topic>Extractive stripping voltammetry</topic><topic>Glassy carbon</topic><topic>Oxidation</topic><topic>Parameter modification</topic><topic>Peppers</topic><topic>Phospholipid modified electrode</topic><topic>Phospholipids</topic><topic>Selectivity</topic><topic>Voltammetry</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Jerga, Radek</creatorcontrib><creatorcontrib>Rajcová, Andrea</creatorcontrib><creatorcontrib>Müllerová, Veronika</creatorcontrib><creatorcontrib>Barták, Petr</creatorcontrib><creatorcontrib>Cankař, Petr</creatorcontrib><creatorcontrib>Navrátil, Tomáš</creatorcontrib><creatorcontrib>Skopalová, Jana</creatorcontrib><collection>CrossRef</collection><collection>Engineered Materials Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><jtitle>Journal of electroanalytical chemistry (Lausanne, Switzerland)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Jerga, Radek</au><au>Rajcová, Andrea</au><au>Müllerová, Veronika</au><au>Barták, Petr</au><au>Cankař, Petr</au><au>Navrátil, Tomáš</au><au>Skopalová, Jana</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Phospholipid modified glassy carbon electrode for determination of chili peppers pungency by ex-situ extraction voltammetry</atitle><jtitle>Journal of electroanalytical chemistry (Lausanne, Switzerland)</jtitle><date>2020-02-01</date><risdate>2020</risdate><volume>858</volume><spage>113790</spage><pages>113790-</pages><artnum>113790</artnum><issn>1572-6657</issn><eissn>1873-2569</eissn><abstract>Objective determination of chili peppers pungency, for which capsaicinoids (CPDs), predominantly capsaicin (CA) and dihydrocapsaicin (DHC) are responsible, belongs to frequently solved tasks in food and medicinal analysis. In this manuscript, application of ex-situ extractive stripping voltammetry (ExSV) utilizing a phospholipid modified glassy carbon electrode is described.
The obtained analytical parameters, e.g., linear dynamic range from 3 to 60 mg L−1, limit of detection 2.1 mg L−1, proved to be fully comparable with those achieved using the direct voltammetric method on a polished glassy carbon electrode and reference HPLC/UV. Although the sensitivity of ExSV was slightly lower compared to the direct method, ExSV provided better selectivity to CPDs due to their lipophilic interactions with the phospholipid layer. Hydrophilic components of the chili pepper samples were not extracted into the phospholipid layer and therefore did not interfere. The developed method was tested on the determination of CPDs in different chili peppers: Foxta, Madras Chilli, Habanero, Carolina Reaper, Bird's eye, Bhut Jolokia, Naga Jolokia extract, and Habanero extract.
Furthermore, the electrochemical reactions of CPDs in acidic aqueous-methanolic media were characterized using an electrochemical cell hyphenated with mass spectrometer and the main oxidation products were identified.
•Phospholipid layer on glassy carbon electrode allows extraction of capsaicinoids.•Extraction improves selectivity and linear range of voltammetric determination.•Ex-situ extraction method was used for determination of chili peppers pungency.•Results accord with HPLC and direct voltammetric method on bare electrode.</abstract><cop>Amsterdam</cop><pub>Elsevier B.V</pub><doi>10.1016/j.jelechem.2019.113790</doi></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1572-6657 |
ispartof | Journal of electroanalytical chemistry (Lausanne, Switzerland), 2020-02, Vol.858, p.113790, Article 113790 |
issn | 1572-6657 1873-2569 |
language | eng |
recordid | cdi_proquest_journals_2376945180 |
source | Elsevier ScienceDirect Journals |
subjects | Asolectin Capsaicinoids Carbon Chemical reactions Chili peppers Electrochemical cells Electrochemical oxidation products Electrodes Extractive stripping voltammetry Glassy carbon Oxidation Parameter modification Peppers Phospholipid modified electrode Phospholipids Selectivity Voltammetry |
title | Phospholipid modified glassy carbon electrode for determination of chili peppers pungency by ex-situ extraction voltammetry |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-31T11%3A45%3A15IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Phospholipid%20modified%20glassy%20carbon%20electrode%20for%20determination%20of%20chili%20peppers%20pungency%20by%20ex-situ%20extraction%20voltammetry&rft.jtitle=Journal%20of%20electroanalytical%20chemistry%20(Lausanne,%20Switzerland)&rft.au=Jerga,%20Radek&rft.date=2020-02-01&rft.volume=858&rft.spage=113790&rft.pages=113790-&rft.artnum=113790&rft.issn=1572-6657&rft.eissn=1873-2569&rft_id=info:doi/10.1016/j.jelechem.2019.113790&rft_dat=%3Cproquest_cross%3E2376945180%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2376945180&rft_id=info:pmid/&rft_els_id=S1572665719310586&rfr_iscdi=true |