Indoor particle inhalability of a stationary and moving manikin

Understanding particle inhalation caused by human activity is vital for developing estimates of inhalation exposure in indoor environments. This study used Computational Fluid Dynamics to compare nasal aspiration efficiency of a stationary manikin in uniform airflow and a moving manikin in stagnant...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Building and environment 2020-02, Vol.169, p.106545, Article 106545
Hauptverfasser: Tao, Yao, Yang, Wei, Inthavong, Kiao, Tu, Jiyuan
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page 106545
container_title Building and environment
container_volume 169
creator Tao, Yao
Yang, Wei
Inthavong, Kiao
Tu, Jiyuan
description Understanding particle inhalation caused by human activity is vital for developing estimates of inhalation exposure in indoor environments. This study used Computational Fluid Dynamics to compare nasal aspiration efficiency of a stationary manikin in uniform airflow and a moving manikin in stagnant air. The model was a full-scale body with detailed facial features at the nose. The stationary manikin case adopted a constant freestream velocities of 0.2 m/s and 0.4 m/s representing typical office wind environments; while the moving manikin case considered a walking speed of 0.4 m/s as a comparison case, followed with additional higher walking speeds (0.8 m/s and 1.6 m/s) to investigate realistic walking scenarios. Inhalation rates through the nose included light and medium breathing at 15 and 27 L per minute. The aspiration efficiency (AE) was used to quantify the nasal particle inhalability from an upstream release source. In order to evaluate the inhalability for the moving manikin, a 3-dimensional particle source was created and validated with a 2-dimensional particle source, which was common in studies for stationary manikins. Discrepancies in aspiration efficiencies were quantified between using 2- and 3-dimensional particle sources. The particle inhalability for a moving manikin was estimated for three particle sizes and three walking speeds. The inhalability of a walking manikin was found higher than a stationary manikin facing the wind, less relevant to particle sizes but more related to walking speeds. This study quantified the particle inhalability for moving manikins to characterise a more comprehensive scenario for modelling human respiration and developing estimations of particle exposure. •Nose-breathing particle inhalability of a stationary and moving body was explored.•The stationary body provided good agreements of aspiration efficiency with reported data.•The nasal inhalabilitiy was higher in moving manikins than in stationary manikins.•The influence from gravitational settling was significant to stationary manikins while minor to moving manikins.
doi_str_mv 10.1016/j.buildenv.2019.106545
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2375482162</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0360132319307577</els_id><sourcerecordid>2375482162</sourcerecordid><originalsourceid>FETCH-LOGICAL-c406t-dee3ecf9522571ac817fc7717ddbf33087de287d469bc94da91d055fc260b9543</originalsourceid><addsrcrecordid>eNqFkE1LAzEQhoMoWKt_QQKet-Y7uycV8aNQ8KLgLWSTrGbdJjXZFvrvTVk9e5mB4X3fmXkAuMRogREW1_2i3frBurBbEISbMhSc8SMww7WklajZ-zGYISpQhSmhp-As5x4VY0PZDNwsg40xwY1OozeDgz586kG3fvDjHsYOaphHPfoYdNpDHSxcx50PH3Ctg__y4RycdHrI7uK3z8Hb48Pr_XO1enla3t-tKsOQGCvrHHWmazghXGJtaiw7IyWW1rYdpaiW1pFSmGha0zCrG2wR550hArUNZ3QOrqbcTYrfW5dH1cdtCmWlIlRyVhMsSFGJSWVSzDm5Tm2SX5fLFUbqAEv16g-WOsBSE6xivJ2Mrvyw8y6pbLwLxlmfnBmVjf6_iB_ZRHZF</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2375482162</pqid></control><display><type>article</type><title>Indoor particle inhalability of a stationary and moving manikin</title><source>Elsevier ScienceDirect Journals</source><creator>Tao, Yao ; Yang, Wei ; Inthavong, Kiao ; Tu, Jiyuan</creator><creatorcontrib>Tao, Yao ; Yang, Wei ; Inthavong, Kiao ; Tu, Jiyuan</creatorcontrib><description>Understanding particle inhalation caused by human activity is vital for developing estimates of inhalation exposure in indoor environments. This study used Computational Fluid Dynamics to compare nasal aspiration efficiency of a stationary manikin in uniform airflow and a moving manikin in stagnant air. The model was a full-scale body with detailed facial features at the nose. The stationary manikin case adopted a constant freestream velocities of 0.2 m/s and 0.4 m/s representing typical office wind environments; while the moving manikin case considered a walking speed of 0.4 m/s as a comparison case, followed with additional higher walking speeds (0.8 m/s and 1.6 m/s) to investigate realistic walking scenarios. Inhalation rates through the nose included light and medium breathing at 15 and 27 L per minute. The aspiration efficiency (AE) was used to quantify the nasal particle inhalability from an upstream release source. In order to evaluate the inhalability for the moving manikin, a 3-dimensional particle source was created and validated with a 2-dimensional particle source, which was common in studies for stationary manikins. Discrepancies in aspiration efficiencies were quantified between using 2- and 3-dimensional particle sources. The particle inhalability for a moving manikin was estimated for three particle sizes and three walking speeds. The inhalability of a walking manikin was found higher than a stationary manikin facing the wind, less relevant to particle sizes but more related to walking speeds. This study quantified the particle inhalability for moving manikins to characterise a more comprehensive scenario for modelling human respiration and developing estimations of particle exposure. •Nose-breathing particle inhalability of a stationary and moving body was explored.•The stationary body provided good agreements of aspiration efficiency with reported data.•The nasal inhalabilitiy was higher in moving manikins than in stationary manikins.•The influence from gravitational settling was significant to stationary manikins while minor to moving manikins.</description><identifier>ISSN: 0360-1323</identifier><identifier>EISSN: 1873-684X</identifier><identifier>DOI: 10.1016/j.buildenv.2019.106545</identifier><language>eng</language><publisher>Oxford: Elsevier Ltd</publisher><subject>Aerodynamics ; Air flow ; Airborne particles ; Aspiration efficiency ; CFD ; Computational fluid dynamics ; Computer applications ; DPM ; Exposure ; Fluid dynamics ; Hydrodynamics ; Indoor environments ; Inhalation ; Moving human ; Nose ; Respiration ; Walking ; Wind</subject><ispartof>Building and environment, 2020-02, Vol.169, p.106545, Article 106545</ispartof><rights>2019 Elsevier Ltd</rights><rights>Copyright Elsevier BV Feb 2020</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c406t-dee3ecf9522571ac817fc7717ddbf33087de287d469bc94da91d055fc260b9543</citedby><cites>FETCH-LOGICAL-c406t-dee3ecf9522571ac817fc7717ddbf33087de287d469bc94da91d055fc260b9543</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.buildenv.2019.106545$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3536,27903,27904,45974</link.rule.ids></links><search><creatorcontrib>Tao, Yao</creatorcontrib><creatorcontrib>Yang, Wei</creatorcontrib><creatorcontrib>Inthavong, Kiao</creatorcontrib><creatorcontrib>Tu, Jiyuan</creatorcontrib><title>Indoor particle inhalability of a stationary and moving manikin</title><title>Building and environment</title><description>Understanding particle inhalation caused by human activity is vital for developing estimates of inhalation exposure in indoor environments. This study used Computational Fluid Dynamics to compare nasal aspiration efficiency of a stationary manikin in uniform airflow and a moving manikin in stagnant air. The model was a full-scale body with detailed facial features at the nose. The stationary manikin case adopted a constant freestream velocities of 0.2 m/s and 0.4 m/s representing typical office wind environments; while the moving manikin case considered a walking speed of 0.4 m/s as a comparison case, followed with additional higher walking speeds (0.8 m/s and 1.6 m/s) to investigate realistic walking scenarios. Inhalation rates through the nose included light and medium breathing at 15 and 27 L per minute. The aspiration efficiency (AE) was used to quantify the nasal particle inhalability from an upstream release source. In order to evaluate the inhalability for the moving manikin, a 3-dimensional particle source was created and validated with a 2-dimensional particle source, which was common in studies for stationary manikins. Discrepancies in aspiration efficiencies were quantified between using 2- and 3-dimensional particle sources. The particle inhalability for a moving manikin was estimated for three particle sizes and three walking speeds. The inhalability of a walking manikin was found higher than a stationary manikin facing the wind, less relevant to particle sizes but more related to walking speeds. This study quantified the particle inhalability for moving manikins to characterise a more comprehensive scenario for modelling human respiration and developing estimations of particle exposure. •Nose-breathing particle inhalability of a stationary and moving body was explored.•The stationary body provided good agreements of aspiration efficiency with reported data.•The nasal inhalabilitiy was higher in moving manikins than in stationary manikins.•The influence from gravitational settling was significant to stationary manikins while minor to moving manikins.</description><subject>Aerodynamics</subject><subject>Air flow</subject><subject>Airborne particles</subject><subject>Aspiration efficiency</subject><subject>CFD</subject><subject>Computational fluid dynamics</subject><subject>Computer applications</subject><subject>DPM</subject><subject>Exposure</subject><subject>Fluid dynamics</subject><subject>Hydrodynamics</subject><subject>Indoor environments</subject><subject>Inhalation</subject><subject>Moving human</subject><subject>Nose</subject><subject>Respiration</subject><subject>Walking</subject><subject>Wind</subject><issn>0360-1323</issn><issn>1873-684X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNqFkE1LAzEQhoMoWKt_QQKet-Y7uycV8aNQ8KLgLWSTrGbdJjXZFvrvTVk9e5mB4X3fmXkAuMRogREW1_2i3frBurBbEISbMhSc8SMww7WklajZ-zGYISpQhSmhp-As5x4VY0PZDNwsg40xwY1OozeDgz586kG3fvDjHsYOaphHPfoYdNpDHSxcx50PH3Ctg__y4RycdHrI7uK3z8Hb48Pr_XO1enla3t-tKsOQGCvrHHWmazghXGJtaiw7IyWW1rYdpaiW1pFSmGha0zCrG2wR550hArUNZ3QOrqbcTYrfW5dH1cdtCmWlIlRyVhMsSFGJSWVSzDm5Tm2SX5fLFUbqAEv16g-WOsBSE6xivJ2Mrvyw8y6pbLwLxlmfnBmVjf6_iB_ZRHZF</recordid><startdate>202002</startdate><enddate>202002</enddate><creator>Tao, Yao</creator><creator>Yang, Wei</creator><creator>Inthavong, Kiao</creator><creator>Tu, Jiyuan</creator><general>Elsevier Ltd</general><general>Elsevier BV</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7ST</scope><scope>8FD</scope><scope>C1K</scope><scope>F28</scope><scope>FR3</scope><scope>KR7</scope><scope>SOI</scope></search><sort><creationdate>202002</creationdate><title>Indoor particle inhalability of a stationary and moving manikin</title><author>Tao, Yao ; Yang, Wei ; Inthavong, Kiao ; Tu, Jiyuan</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c406t-dee3ecf9522571ac817fc7717ddbf33087de287d469bc94da91d055fc260b9543</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Aerodynamics</topic><topic>Air flow</topic><topic>Airborne particles</topic><topic>Aspiration efficiency</topic><topic>CFD</topic><topic>Computational fluid dynamics</topic><topic>Computer applications</topic><topic>DPM</topic><topic>Exposure</topic><topic>Fluid dynamics</topic><topic>Hydrodynamics</topic><topic>Indoor environments</topic><topic>Inhalation</topic><topic>Moving human</topic><topic>Nose</topic><topic>Respiration</topic><topic>Walking</topic><topic>Wind</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Tao, Yao</creatorcontrib><creatorcontrib>Yang, Wei</creatorcontrib><creatorcontrib>Inthavong, Kiao</creatorcontrib><creatorcontrib>Tu, Jiyuan</creatorcontrib><collection>CrossRef</collection><collection>Environment Abstracts</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ANTE: Abstracts in New Technology &amp; Engineering</collection><collection>Engineering Research Database</collection><collection>Civil Engineering Abstracts</collection><collection>Environment Abstracts</collection><jtitle>Building and environment</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Tao, Yao</au><au>Yang, Wei</au><au>Inthavong, Kiao</au><au>Tu, Jiyuan</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Indoor particle inhalability of a stationary and moving manikin</atitle><jtitle>Building and environment</jtitle><date>2020-02</date><risdate>2020</risdate><volume>169</volume><spage>106545</spage><pages>106545-</pages><artnum>106545</artnum><issn>0360-1323</issn><eissn>1873-684X</eissn><abstract>Understanding particle inhalation caused by human activity is vital for developing estimates of inhalation exposure in indoor environments. This study used Computational Fluid Dynamics to compare nasal aspiration efficiency of a stationary manikin in uniform airflow and a moving manikin in stagnant air. The model was a full-scale body with detailed facial features at the nose. The stationary manikin case adopted a constant freestream velocities of 0.2 m/s and 0.4 m/s representing typical office wind environments; while the moving manikin case considered a walking speed of 0.4 m/s as a comparison case, followed with additional higher walking speeds (0.8 m/s and 1.6 m/s) to investigate realistic walking scenarios. Inhalation rates through the nose included light and medium breathing at 15 and 27 L per minute. The aspiration efficiency (AE) was used to quantify the nasal particle inhalability from an upstream release source. In order to evaluate the inhalability for the moving manikin, a 3-dimensional particle source was created and validated with a 2-dimensional particle source, which was common in studies for stationary manikins. Discrepancies in aspiration efficiencies were quantified between using 2- and 3-dimensional particle sources. The particle inhalability for a moving manikin was estimated for three particle sizes and three walking speeds. The inhalability of a walking manikin was found higher than a stationary manikin facing the wind, less relevant to particle sizes but more related to walking speeds. This study quantified the particle inhalability for moving manikins to characterise a more comprehensive scenario for modelling human respiration and developing estimations of particle exposure. •Nose-breathing particle inhalability of a stationary and moving body was explored.•The stationary body provided good agreements of aspiration efficiency with reported data.•The nasal inhalabilitiy was higher in moving manikins than in stationary manikins.•The influence from gravitational settling was significant to stationary manikins while minor to moving manikins.</abstract><cop>Oxford</cop><pub>Elsevier Ltd</pub><doi>10.1016/j.buildenv.2019.106545</doi></addata></record>
fulltext fulltext
identifier ISSN: 0360-1323
ispartof Building and environment, 2020-02, Vol.169, p.106545, Article 106545
issn 0360-1323
1873-684X
language eng
recordid cdi_proquest_journals_2375482162
source Elsevier ScienceDirect Journals
subjects Aerodynamics
Air flow
Airborne particles
Aspiration efficiency
CFD
Computational fluid dynamics
Computer applications
DPM
Exposure
Fluid dynamics
Hydrodynamics
Indoor environments
Inhalation
Moving human
Nose
Respiration
Walking
Wind
title Indoor particle inhalability of a stationary and moving manikin
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-22T12%3A45%3A44IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Indoor%20particle%20inhalability%20of%20a%20stationary%20and%20moving%20manikin&rft.jtitle=Building%20and%20environment&rft.au=Tao,%20Yao&rft.date=2020-02&rft.volume=169&rft.spage=106545&rft.pages=106545-&rft.artnum=106545&rft.issn=0360-1323&rft.eissn=1873-684X&rft_id=info:doi/10.1016/j.buildenv.2019.106545&rft_dat=%3Cproquest_cross%3E2375482162%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2375482162&rft_id=info:pmid/&rft_els_id=S0360132319307577&rfr_iscdi=true