Ultra-selective detection of Cd2+ and Pb2+ using glycine functionalized reduced graphene oxide/polyaniline nanocomposite electrode

•An efficient electrochemical sensor with high sensitivity was prepared.•Cd2+ and Pb2+ were detected successfully by voltammetry technique.•Detection limit was 0.07 nM for Cd2+ and 0.072 nM for Pb2+. An efficient electrochemical sensor with high sensitivity, selectivity and fast detection ability wa...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Synthetic metals 2019-11, Vol.257, p.116185, Article 116185
Hauptverfasser: Hanif, Farzana, Tahir, Amiza, Akhtar, Mehwish, Waseem, Muhammad, Haider, Sajjad, Aly Aboud, Mohamed F., Shakir, Imran, Imran, Muhammad, Warsi, Muhammad Farooq
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page 116185
container_title Synthetic metals
container_volume 257
creator Hanif, Farzana
Tahir, Amiza
Akhtar, Mehwish
Waseem, Muhammad
Haider, Sajjad
Aly Aboud, Mohamed F.
Shakir, Imran
Imran, Muhammad
Warsi, Muhammad Farooq
description •An efficient electrochemical sensor with high sensitivity was prepared.•Cd2+ and Pb2+ were detected successfully by voltammetry technique.•Detection limit was 0.07 nM for Cd2+ and 0.072 nM for Pb2+. An efficient electrochemical sensor with high sensitivity, selectivity and fast detection ability was developed for the trace level detection of Cd2+ and Pb2+ using glycine functionalized reduced graphene oxide/ polyaniline nanocomposite as a recognition layer. The morphological and structural studies of synthesized receptor nanocomposites were verified via X-ray diffraction, Fourier transform infrared spectroscopy, UV/Visible spectroscopy, Raman studies, SEM analysis and BET studies. Electrochemical features were explored via electrochemical impedance spectroscopy and cyclic voltammetry whereas the stripping voltammetric behavior of modified electrodes was analyzed by utilizing square wave anodic stripping voltammetry. The chemical and electrochemical parameters which influence the performance of modified sensors towards the accumulation and stripping of metal ions, for instance, pH of the medium, accumulation potential, scan rate, stripping medium and foreign species were carefully studied to achieve best sensing response. The designated sensor exhibited the excellent sensing properties towards heavy metal ions with quite low limit of detection 0.07 nM for Cd2+ and 0.072 nM for Pb2+ respectively. The proposed methodology allowed a robust and sensitive inspection of Pb2+ and Cd2+ in tap water, making this novel platform a promising candidate for field applications to monitor heavy metal contaminants. Most significantly, this methodology can be applicable for the ultrasensitive detection of other noxious pollutants due to excellent properties of receptor species such as fast electron transfer kinetics, broad surface area, wide conduction path, and exceptional electro-catalytic properties.
doi_str_mv 10.1016/j.synthmet.2019.116185
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2350375136</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0379677919305491</els_id><sourcerecordid>2350375136</sourcerecordid><originalsourceid>FETCH-LOGICAL-c307t-fa3c830809fa84ffd9c8c73b5267c3dbab31b6e1ea5e6333d716c7d3ae3f74fc3</originalsourceid><addsrcrecordid>eNqFkEtLAzEUhYMoWB9_QQIuZWoy6SQzO6X4AkEXdh0yyU1NmSZjMiPWpb_c1Ora1T1wz7mPD6EzSqaUUH65mqaNH17XMExLQpsppZzW1R6a0Fo0BSsbso8mhGXNhWgO0VFKK0Kys6wm6GvRDVEVCTrQg3sHbGDYquBxsHhuygusvMHPbRZjcn6Jl91GOw_Yjv7Hpzr3CQZHMKPOdRlV_wq5Hz6cgcs-dBvlXbdNeOWDDus-JDcA_tkYg4ETdGBVl-D0tx6jxe3Ny_y-eHy6e5hfPxaaETEUVjFdM1KTxqp6Zq1pdK0Fa6uSC81Mq1pGWw4UVAWcMWYE5VoYpoBZMbOaHaPz3dw-hrcR0iBXYYz5_iRLVmVAFWU8u_jOpWNIKYKVfXRrFTeSErnlLVfyj7fc8pY73jl4tQtC_uHdQZRJO_CZiYv5U2mC-2_EN7NlkFM</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2350375136</pqid></control><display><type>article</type><title>Ultra-selective detection of Cd2+ and Pb2+ using glycine functionalized reduced graphene oxide/polyaniline nanocomposite electrode</title><source>Elsevier ScienceDirect Journals</source><creator>Hanif, Farzana ; Tahir, Amiza ; Akhtar, Mehwish ; Waseem, Muhammad ; Haider, Sajjad ; Aly Aboud, Mohamed F. ; Shakir, Imran ; Imran, Muhammad ; Warsi, Muhammad Farooq</creator><creatorcontrib>Hanif, Farzana ; Tahir, Amiza ; Akhtar, Mehwish ; Waseem, Muhammad ; Haider, Sajjad ; Aly Aboud, Mohamed F. ; Shakir, Imran ; Imran, Muhammad ; Warsi, Muhammad Farooq</creatorcontrib><description>•An efficient electrochemical sensor with high sensitivity was prepared.•Cd2+ and Pb2+ were detected successfully by voltammetry technique.•Detection limit was 0.07 nM for Cd2+ and 0.072 nM for Pb2+. An efficient electrochemical sensor with high sensitivity, selectivity and fast detection ability was developed for the trace level detection of Cd2+ and Pb2+ using glycine functionalized reduced graphene oxide/ polyaniline nanocomposite as a recognition layer. The morphological and structural studies of synthesized receptor nanocomposites were verified via X-ray diffraction, Fourier transform infrared spectroscopy, UV/Visible spectroscopy, Raman studies, SEM analysis and BET studies. Electrochemical features were explored via electrochemical impedance spectroscopy and cyclic voltammetry whereas the stripping voltammetric behavior of modified electrodes was analyzed by utilizing square wave anodic stripping voltammetry. The chemical and electrochemical parameters which influence the performance of modified sensors towards the accumulation and stripping of metal ions, for instance, pH of the medium, accumulation potential, scan rate, stripping medium and foreign species were carefully studied to achieve best sensing response. The designated sensor exhibited the excellent sensing properties towards heavy metal ions with quite low limit of detection 0.07 nM for Cd2+ and 0.072 nM for Pb2+ respectively. The proposed methodology allowed a robust and sensitive inspection of Pb2+ and Cd2+ in tap water, making this novel platform a promising candidate for field applications to monitor heavy metal contaminants. Most significantly, this methodology can be applicable for the ultrasensitive detection of other noxious pollutants due to excellent properties of receptor species such as fast electron transfer kinetics, broad surface area, wide conduction path, and exceptional electro-catalytic properties.</description><identifier>ISSN: 0379-6779</identifier><identifier>EISSN: 1879-3290</identifier><identifier>DOI: 10.1016/j.synthmet.2019.116185</identifier><language>eng</language><publisher>Lausanne: Elsevier B.V</publisher><subject>Accumulation ; Anodic stripping ; Cadmium ; Chemical sensors ; Composite ; Contaminants ; Drinking water ; Electrochemical impedance spectroscopy ; Electrochemical sensor ; Electrodes ; Electron transfer ; Glycine ; Graphene ; Heavy metals ; Infrared analysis ; Inspection ; Metal ions ; Nanocomposites ; Organic chemistry ; Parameter modification ; Pollutants ; Polyaniline ; Polyanilines ; Properties (attributes) ; Reaction kinetics ; Selectivity ; Sensitivity and selectivity ; Spectroscopic analysis ; Spectrum analysis ; Square waves ; Toxic metal ions ; Voltammetry</subject><ispartof>Synthetic metals, 2019-11, Vol.257, p.116185, Article 116185</ispartof><rights>2019 Elsevier B.V.</rights><rights>Copyright Elsevier BV Nov 2019</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c307t-fa3c830809fa84ffd9c8c73b5267c3dbab31b6e1ea5e6333d716c7d3ae3f74fc3</citedby><cites>FETCH-LOGICAL-c307t-fa3c830809fa84ffd9c8c73b5267c3dbab31b6e1ea5e6333d716c7d3ae3f74fc3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0379677919305491$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids></links><search><creatorcontrib>Hanif, Farzana</creatorcontrib><creatorcontrib>Tahir, Amiza</creatorcontrib><creatorcontrib>Akhtar, Mehwish</creatorcontrib><creatorcontrib>Waseem, Muhammad</creatorcontrib><creatorcontrib>Haider, Sajjad</creatorcontrib><creatorcontrib>Aly Aboud, Mohamed F.</creatorcontrib><creatorcontrib>Shakir, Imran</creatorcontrib><creatorcontrib>Imran, Muhammad</creatorcontrib><creatorcontrib>Warsi, Muhammad Farooq</creatorcontrib><title>Ultra-selective detection of Cd2+ and Pb2+ using glycine functionalized reduced graphene oxide/polyaniline nanocomposite electrode</title><title>Synthetic metals</title><description>•An efficient electrochemical sensor with high sensitivity was prepared.•Cd2+ and Pb2+ were detected successfully by voltammetry technique.•Detection limit was 0.07 nM for Cd2+ and 0.072 nM for Pb2+. An efficient electrochemical sensor with high sensitivity, selectivity and fast detection ability was developed for the trace level detection of Cd2+ and Pb2+ using glycine functionalized reduced graphene oxide/ polyaniline nanocomposite as a recognition layer. The morphological and structural studies of synthesized receptor nanocomposites were verified via X-ray diffraction, Fourier transform infrared spectroscopy, UV/Visible spectroscopy, Raman studies, SEM analysis and BET studies. Electrochemical features were explored via electrochemical impedance spectroscopy and cyclic voltammetry whereas the stripping voltammetric behavior of modified electrodes was analyzed by utilizing square wave anodic stripping voltammetry. The chemical and electrochemical parameters which influence the performance of modified sensors towards the accumulation and stripping of metal ions, for instance, pH of the medium, accumulation potential, scan rate, stripping medium and foreign species were carefully studied to achieve best sensing response. The designated sensor exhibited the excellent sensing properties towards heavy metal ions with quite low limit of detection 0.07 nM for Cd2+ and 0.072 nM for Pb2+ respectively. The proposed methodology allowed a robust and sensitive inspection of Pb2+ and Cd2+ in tap water, making this novel platform a promising candidate for field applications to monitor heavy metal contaminants. Most significantly, this methodology can be applicable for the ultrasensitive detection of other noxious pollutants due to excellent properties of receptor species such as fast electron transfer kinetics, broad surface area, wide conduction path, and exceptional electro-catalytic properties.</description><subject>Accumulation</subject><subject>Anodic stripping</subject><subject>Cadmium</subject><subject>Chemical sensors</subject><subject>Composite</subject><subject>Contaminants</subject><subject>Drinking water</subject><subject>Electrochemical impedance spectroscopy</subject><subject>Electrochemical sensor</subject><subject>Electrodes</subject><subject>Electron transfer</subject><subject>Glycine</subject><subject>Graphene</subject><subject>Heavy metals</subject><subject>Infrared analysis</subject><subject>Inspection</subject><subject>Metal ions</subject><subject>Nanocomposites</subject><subject>Organic chemistry</subject><subject>Parameter modification</subject><subject>Pollutants</subject><subject>Polyaniline</subject><subject>Polyanilines</subject><subject>Properties (attributes)</subject><subject>Reaction kinetics</subject><subject>Selectivity</subject><subject>Sensitivity and selectivity</subject><subject>Spectroscopic analysis</subject><subject>Spectrum analysis</subject><subject>Square waves</subject><subject>Toxic metal ions</subject><subject>Voltammetry</subject><issn>0379-6779</issn><issn>1879-3290</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNqFkEtLAzEUhYMoWB9_QQIuZWoy6SQzO6X4AkEXdh0yyU1NmSZjMiPWpb_c1Ora1T1wz7mPD6EzSqaUUH65mqaNH17XMExLQpsppZzW1R6a0Fo0BSsbso8mhGXNhWgO0VFKK0Kys6wm6GvRDVEVCTrQg3sHbGDYquBxsHhuygusvMHPbRZjcn6Jl91GOw_Yjv7Hpzr3CQZHMKPOdRlV_wq5Hz6cgcs-dBvlXbdNeOWDDus-JDcA_tkYg4ETdGBVl-D0tx6jxe3Ny_y-eHy6e5hfPxaaETEUVjFdM1KTxqp6Zq1pdK0Fa6uSC81Mq1pGWw4UVAWcMWYE5VoYpoBZMbOaHaPz3dw-hrcR0iBXYYz5_iRLVmVAFWU8u_jOpWNIKYKVfXRrFTeSErnlLVfyj7fc8pY73jl4tQtC_uHdQZRJO_CZiYv5U2mC-2_EN7NlkFM</recordid><startdate>20191101</startdate><enddate>20191101</enddate><creator>Hanif, Farzana</creator><creator>Tahir, Amiza</creator><creator>Akhtar, Mehwish</creator><creator>Waseem, Muhammad</creator><creator>Haider, Sajjad</creator><creator>Aly Aboud, Mohamed F.</creator><creator>Shakir, Imran</creator><creator>Imran, Muhammad</creator><creator>Warsi, Muhammad Farooq</creator><general>Elsevier B.V</general><general>Elsevier BV</general><scope>AAYXX</scope><scope>CITATION</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope></search><sort><creationdate>20191101</creationdate><title>Ultra-selective detection of Cd2+ and Pb2+ using glycine functionalized reduced graphene oxide/polyaniline nanocomposite electrode</title><author>Hanif, Farzana ; Tahir, Amiza ; Akhtar, Mehwish ; Waseem, Muhammad ; Haider, Sajjad ; Aly Aboud, Mohamed F. ; Shakir, Imran ; Imran, Muhammad ; Warsi, Muhammad Farooq</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c307t-fa3c830809fa84ffd9c8c73b5267c3dbab31b6e1ea5e6333d716c7d3ae3f74fc3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Accumulation</topic><topic>Anodic stripping</topic><topic>Cadmium</topic><topic>Chemical sensors</topic><topic>Composite</topic><topic>Contaminants</topic><topic>Drinking water</topic><topic>Electrochemical impedance spectroscopy</topic><topic>Electrochemical sensor</topic><topic>Electrodes</topic><topic>Electron transfer</topic><topic>Glycine</topic><topic>Graphene</topic><topic>Heavy metals</topic><topic>Infrared analysis</topic><topic>Inspection</topic><topic>Metal ions</topic><topic>Nanocomposites</topic><topic>Organic chemistry</topic><topic>Parameter modification</topic><topic>Pollutants</topic><topic>Polyaniline</topic><topic>Polyanilines</topic><topic>Properties (attributes)</topic><topic>Reaction kinetics</topic><topic>Selectivity</topic><topic>Sensitivity and selectivity</topic><topic>Spectroscopic analysis</topic><topic>Spectrum analysis</topic><topic>Square waves</topic><topic>Toxic metal ions</topic><topic>Voltammetry</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Hanif, Farzana</creatorcontrib><creatorcontrib>Tahir, Amiza</creatorcontrib><creatorcontrib>Akhtar, Mehwish</creatorcontrib><creatorcontrib>Waseem, Muhammad</creatorcontrib><creatorcontrib>Haider, Sajjad</creatorcontrib><creatorcontrib>Aly Aboud, Mohamed F.</creatorcontrib><creatorcontrib>Shakir, Imran</creatorcontrib><creatorcontrib>Imran, Muhammad</creatorcontrib><creatorcontrib>Warsi, Muhammad Farooq</creatorcontrib><collection>CrossRef</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><jtitle>Synthetic metals</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hanif, Farzana</au><au>Tahir, Amiza</au><au>Akhtar, Mehwish</au><au>Waseem, Muhammad</au><au>Haider, Sajjad</au><au>Aly Aboud, Mohamed F.</au><au>Shakir, Imran</au><au>Imran, Muhammad</au><au>Warsi, Muhammad Farooq</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Ultra-selective detection of Cd2+ and Pb2+ using glycine functionalized reduced graphene oxide/polyaniline nanocomposite electrode</atitle><jtitle>Synthetic metals</jtitle><date>2019-11-01</date><risdate>2019</risdate><volume>257</volume><spage>116185</spage><pages>116185-</pages><artnum>116185</artnum><issn>0379-6779</issn><eissn>1879-3290</eissn><abstract>•An efficient electrochemical sensor with high sensitivity was prepared.•Cd2+ and Pb2+ were detected successfully by voltammetry technique.•Detection limit was 0.07 nM for Cd2+ and 0.072 nM for Pb2+. An efficient electrochemical sensor with high sensitivity, selectivity and fast detection ability was developed for the trace level detection of Cd2+ and Pb2+ using glycine functionalized reduced graphene oxide/ polyaniline nanocomposite as a recognition layer. The morphological and structural studies of synthesized receptor nanocomposites were verified via X-ray diffraction, Fourier transform infrared spectroscopy, UV/Visible spectroscopy, Raman studies, SEM analysis and BET studies. Electrochemical features were explored via electrochemical impedance spectroscopy and cyclic voltammetry whereas the stripping voltammetric behavior of modified electrodes was analyzed by utilizing square wave anodic stripping voltammetry. The chemical and electrochemical parameters which influence the performance of modified sensors towards the accumulation and stripping of metal ions, for instance, pH of the medium, accumulation potential, scan rate, stripping medium and foreign species were carefully studied to achieve best sensing response. The designated sensor exhibited the excellent sensing properties towards heavy metal ions with quite low limit of detection 0.07 nM for Cd2+ and 0.072 nM for Pb2+ respectively. The proposed methodology allowed a robust and sensitive inspection of Pb2+ and Cd2+ in tap water, making this novel platform a promising candidate for field applications to monitor heavy metal contaminants. Most significantly, this methodology can be applicable for the ultrasensitive detection of other noxious pollutants due to excellent properties of receptor species such as fast electron transfer kinetics, broad surface area, wide conduction path, and exceptional electro-catalytic properties.</abstract><cop>Lausanne</cop><pub>Elsevier B.V</pub><doi>10.1016/j.synthmet.2019.116185</doi></addata></record>
fulltext fulltext
identifier ISSN: 0379-6779
ispartof Synthetic metals, 2019-11, Vol.257, p.116185, Article 116185
issn 0379-6779
1879-3290
language eng
recordid cdi_proquest_journals_2350375136
source Elsevier ScienceDirect Journals
subjects Accumulation
Anodic stripping
Cadmium
Chemical sensors
Composite
Contaminants
Drinking water
Electrochemical impedance spectroscopy
Electrochemical sensor
Electrodes
Electron transfer
Glycine
Graphene
Heavy metals
Infrared analysis
Inspection
Metal ions
Nanocomposites
Organic chemistry
Parameter modification
Pollutants
Polyaniline
Polyanilines
Properties (attributes)
Reaction kinetics
Selectivity
Sensitivity and selectivity
Spectroscopic analysis
Spectrum analysis
Square waves
Toxic metal ions
Voltammetry
title Ultra-selective detection of Cd2+ and Pb2+ using glycine functionalized reduced graphene oxide/polyaniline nanocomposite electrode
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-09T19%3A44%3A26IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Ultra-selective%20detection%20of%20Cd2+%20and%20Pb2+%20using%20glycine%20functionalized%20reduced%20graphene%20oxide/polyaniline%20nanocomposite%20electrode&rft.jtitle=Synthetic%20metals&rft.au=Hanif,%20Farzana&rft.date=2019-11-01&rft.volume=257&rft.spage=116185&rft.pages=116185-&rft.artnum=116185&rft.issn=0379-6779&rft.eissn=1879-3290&rft_id=info:doi/10.1016/j.synthmet.2019.116185&rft_dat=%3Cproquest_cross%3E2350375136%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2350375136&rft_id=info:pmid/&rft_els_id=S0379677919305491&rfr_iscdi=true