Optimization and adjustment of impact set-up for testing of insulated pads of ITER blanket module connectors and first wall
Insulated pads are used on ITER blanket module connectors and the first wall; their main insulating function is to break any current loop between the shield block and vacuum vessel and/or between the first wall panel and shield block. The design of the pads consists of a cylindrical or prismatic bod...
Gespeichert in:
Veröffentlicht in: | Fusion engineering and design 2019-09, Vol.146, p.2474-2478 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Insulated pads are used on ITER blanket module connectors and the first wall; their main insulating function is to break any current loop between the shield block and vacuum vessel and/or between the first wall panel and shield block. The design of the pads consists of a cylindrical or prismatic body manufactured from NiAl-bronze, a ceramic insulating coating which is applied on interfacing surfaces of the pad body. The pads work in ultra-high vacuum conditions and at elevated temperature 100 – 300оC. Static and dynamic loads up to 2 MN can act on the insulated pads during various plasma events in ITER.
The qualification program for the insulated pads consists of cyclic and impact tests. The tests are performed for two categories of loading anticipated from plasma events. The impact tests are performed on a weight drop test bench, which has been designed and manufactured in JSC “NIKIET”.
The description of the pad design and the impact test set-up, the results of analysis for justification of the set-up parameters, and the results of the test bench commissioning are presented in this paper. |
---|---|
ISSN: | 0920-3796 1873-7196 |
DOI: | 10.1016/j.fusengdes.2019.04.022 |