On the Estimated Measurement Uncertainty of the Insertion Loss in a Reverberation Chamber Including Frequency Stirring

In this paper, we present an improved model of measurement standard uncertainty of the insertion loss in a reverberation chamber (RC), including frequency stirring. Differently from the previous model, the enhanced one does not require specific conditions on the parameter to be measured. Such an enh...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on electromagnetic compatibility 2019-10, Vol.61 (5), p.1414-1422
Hauptverfasser: Gifuni, Angelo, Bastianelli, Luca, Migliaccio, Maurizio, Moglie, Franco, Mariani Primiani, Valter, Gradoni, Gabriele
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In this paper, we present an improved model of measurement standard uncertainty of the insertion loss in a reverberation chamber (RC), including frequency stirring. Differently from the previous model, the enhanced one does not require specific conditions on the parameter to be measured. Such an enhancement is applicable for all usable measurement conditions in RCs. Moreover, a majorant is derived, that is obtained under a weak condition on the coefficient of variation of the parameter to be measured. Results from measurements support the validity of both the proposed enhancement and the majorant.
ISSN:0018-9375
1558-187X
DOI:10.1109/TEMC.2018.2870073