Trace determination of uranium preconcentrated using graphene oxide by total reflection X‐ray fluorescence spectrometry
A new method based on dispersive microsolid phase extraction using graphene oxide (GO) as a solid adsorbent and total reflection X‐ray fluorescence (TXRF) spectrometry is proposed for trace determination of uranium. In the developed methodology, a suspension of GO was injected into uranium‐spiked mu...
Gespeichert in:
Veröffentlicht in: | X-ray spectrometry 2019-09, Vol.48 (5), p.366-374 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 374 |
---|---|
container_issue | 5 |
container_start_page | 366 |
container_title | X-ray spectrometry |
container_volume | 48 |
creator | Takahashi, Hiroaki Izumoto, Yukie Matsuyama, Tsugufumi Yoshii, Hiroshi |
description | A new method based on dispersive microsolid phase extraction using graphene oxide (GO) as a solid adsorbent and total reflection X‐ray fluorescence (TXRF) spectrometry is proposed for trace determination of uranium. In the developed methodology, a suspension of GO was injected into uranium‐spiked multielement solutions including rubidium; after filtration, the membrane filter with collected GO was placed in a small volume of internal standard acid solution and the eluent containing uranium was deposited onto a fluorine resin‐coated slide glass, which is a disposable sample stage. Using GO was effective for removal of rubidium from the measurement solution to avoid interference between Rb Kα peak and U Lα peak. The high enrichment factor of 150 enables obtaining uranium detection limits of 0.042, 0.087, and 0.12 μg L−1 for ionic strength of 0.01, 0.1, and 1 mol L−1, respectively. Such low detection limits were obtained by using a benchtop TXRF spectrometer with 5‐min measurement. The proposed method is suitable for trace uranium determination in water, including high salinity samples. |
doi_str_mv | 10.1002/xrs.3032 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2280180901</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2280180901</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4032-7fea60963fe7e2cbadf12b1c217ded28785e2eb8c9764c33df2756c55daf835c3</originalsourceid><addsrcrecordid>eNp1kMtKw0AUhgdRsFbBRxhw4yZ1LrkupXiDgqAVuguTyZmakmTimQSbnY_gM_okTlu3rs7ifHw__0_IJWczzpi42aKbSSbFEZlwliVBGMnsmEwYC7MgFWF8Ss6c2zDGGefZhIxLVBpoCT1gU7Wqr2xLraEDqrYaGtohaNtqaHtUPZR0cFW7pmtU3Tu0QO22KoEWI-1tr2qKYGrQe8fq5-sb1UhNPVgE5w0-xnX-i7aBHsdzcmJU7eDi707J2_3dcv4YLJ4fnua3i0CHvkaQGFAxy2JpIAGhC1UaLgquBU9KKEWapBEIKFKdJXGopSyNSKJYR1GpTCojLafk6uDt0H4M4Pp8YwdsfWQuRMp4yjLGPXV9oDRa53yPvMOqUTjmnOW7YXM_bL4b1qPBAf2sahj_5fLVy-ue_wW90X5U</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2280180901</pqid></control><display><type>article</type><title>Trace determination of uranium preconcentrated using graphene oxide by total reflection X‐ray fluorescence spectrometry</title><source>Access via Wiley Online Library</source><creator>Takahashi, Hiroaki ; Izumoto, Yukie ; Matsuyama, Tsugufumi ; Yoshii, Hiroshi</creator><creatorcontrib>Takahashi, Hiroaki ; Izumoto, Yukie ; Matsuyama, Tsugufumi ; Yoshii, Hiroshi</creatorcontrib><description>A new method based on dispersive microsolid phase extraction using graphene oxide (GO) as a solid adsorbent and total reflection X‐ray fluorescence (TXRF) spectrometry is proposed for trace determination of uranium. In the developed methodology, a suspension of GO was injected into uranium‐spiked multielement solutions including rubidium; after filtration, the membrane filter with collected GO was placed in a small volume of internal standard acid solution and the eluent containing uranium was deposited onto a fluorine resin‐coated slide glass, which is a disposable sample stage. Using GO was effective for removal of rubidium from the measurement solution to avoid interference between Rb Kα peak and U Lα peak. The high enrichment factor of 150 enables obtaining uranium detection limits of 0.042, 0.087, and 0.12 μg L−1 for ionic strength of 0.01, 0.1, and 1 mol L−1, respectively. Such low detection limits were obtained by using a benchtop TXRF spectrometer with 5‐min measurement. The proposed method is suitable for trace uranium determination in water, including high salinity samples.</description><identifier>ISSN: 0049-8246</identifier><identifier>EISSN: 1097-4539</identifier><identifier>DOI: 10.1002/xrs.3032</identifier><language>eng</language><publisher>Bognor Regis: Wiley Subscription Services, Inc</publisher><subject>Detection limits ; Fluorescence ; Fluorine ; Graphene ; Ions ; Reflection ; Rubidium ; Scientific imaging ; Spectrometry ; Spectroscopy ; Uranium</subject><ispartof>X-ray spectrometry, 2019-09, Vol.48 (5), p.366-374</ispartof><rights>2019 John Wiley & Sons, Ltd.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4032-7fea60963fe7e2cbadf12b1c217ded28785e2eb8c9764c33df2756c55daf835c3</citedby><cites>FETCH-LOGICAL-c4032-7fea60963fe7e2cbadf12b1c217ded28785e2eb8c9764c33df2756c55daf835c3</cites><orcidid>0000-0002-5848-7654 ; 0000-0001-5952-7673 ; 0000-0003-3410-2868 ; 0000-0002-9116-5876</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Fxrs.3032$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Fxrs.3032$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,780,784,1417,27924,27925,45574,45575</link.rule.ids></links><search><creatorcontrib>Takahashi, Hiroaki</creatorcontrib><creatorcontrib>Izumoto, Yukie</creatorcontrib><creatorcontrib>Matsuyama, Tsugufumi</creatorcontrib><creatorcontrib>Yoshii, Hiroshi</creatorcontrib><title>Trace determination of uranium preconcentrated using graphene oxide by total reflection X‐ray fluorescence spectrometry</title><title>X-ray spectrometry</title><description>A new method based on dispersive microsolid phase extraction using graphene oxide (GO) as a solid adsorbent and total reflection X‐ray fluorescence (TXRF) spectrometry is proposed for trace determination of uranium. In the developed methodology, a suspension of GO was injected into uranium‐spiked multielement solutions including rubidium; after filtration, the membrane filter with collected GO was placed in a small volume of internal standard acid solution and the eluent containing uranium was deposited onto a fluorine resin‐coated slide glass, which is a disposable sample stage. Using GO was effective for removal of rubidium from the measurement solution to avoid interference between Rb Kα peak and U Lα peak. The high enrichment factor of 150 enables obtaining uranium detection limits of 0.042, 0.087, and 0.12 μg L−1 for ionic strength of 0.01, 0.1, and 1 mol L−1, respectively. Such low detection limits were obtained by using a benchtop TXRF spectrometer with 5‐min measurement. The proposed method is suitable for trace uranium determination in water, including high salinity samples.</description><subject>Detection limits</subject><subject>Fluorescence</subject><subject>Fluorine</subject><subject>Graphene</subject><subject>Ions</subject><subject>Reflection</subject><subject>Rubidium</subject><subject>Scientific imaging</subject><subject>Spectrometry</subject><subject>Spectroscopy</subject><subject>Uranium</subject><issn>0049-8246</issn><issn>1097-4539</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNp1kMtKw0AUhgdRsFbBRxhw4yZ1LrkupXiDgqAVuguTyZmakmTimQSbnY_gM_okTlu3rs7ifHw__0_IJWczzpi42aKbSSbFEZlwliVBGMnsmEwYC7MgFWF8Ss6c2zDGGefZhIxLVBpoCT1gU7Wqr2xLraEDqrYaGtohaNtqaHtUPZR0cFW7pmtU3Tu0QO22KoEWI-1tr2qKYGrQe8fq5-sb1UhNPVgE5w0-xnX-i7aBHsdzcmJU7eDi707J2_3dcv4YLJ4fnua3i0CHvkaQGFAxy2JpIAGhC1UaLgquBU9KKEWapBEIKFKdJXGopSyNSKJYR1GpTCojLafk6uDt0H4M4Pp8YwdsfWQuRMp4yjLGPXV9oDRa53yPvMOqUTjmnOW7YXM_bL4b1qPBAf2sahj_5fLVy-ue_wW90X5U</recordid><startdate>201909</startdate><enddate>201909</enddate><creator>Takahashi, Hiroaki</creator><creator>Izumoto, Yukie</creator><creator>Matsuyama, Tsugufumi</creator><creator>Yoshii, Hiroshi</creator><general>Wiley Subscription Services, Inc</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SR</scope><scope>7U5</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope><scope>JQ2</scope><scope>L7M</scope><orcidid>https://orcid.org/0000-0002-5848-7654</orcidid><orcidid>https://orcid.org/0000-0001-5952-7673</orcidid><orcidid>https://orcid.org/0000-0003-3410-2868</orcidid><orcidid>https://orcid.org/0000-0002-9116-5876</orcidid></search><sort><creationdate>201909</creationdate><title>Trace determination of uranium preconcentrated using graphene oxide by total reflection X‐ray fluorescence spectrometry</title><author>Takahashi, Hiroaki ; Izumoto, Yukie ; Matsuyama, Tsugufumi ; Yoshii, Hiroshi</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4032-7fea60963fe7e2cbadf12b1c217ded28785e2eb8c9764c33df2756c55daf835c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Detection limits</topic><topic>Fluorescence</topic><topic>Fluorine</topic><topic>Graphene</topic><topic>Ions</topic><topic>Reflection</topic><topic>Rubidium</topic><topic>Scientific imaging</topic><topic>Spectrometry</topic><topic>Spectroscopy</topic><topic>Uranium</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Takahashi, Hiroaki</creatorcontrib><creatorcontrib>Izumoto, Yukie</creatorcontrib><creatorcontrib>Matsuyama, Tsugufumi</creatorcontrib><creatorcontrib>Yoshii, Hiroshi</creatorcontrib><collection>CrossRef</collection><collection>Engineered Materials Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>X-ray spectrometry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Takahashi, Hiroaki</au><au>Izumoto, Yukie</au><au>Matsuyama, Tsugufumi</au><au>Yoshii, Hiroshi</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Trace determination of uranium preconcentrated using graphene oxide by total reflection X‐ray fluorescence spectrometry</atitle><jtitle>X-ray spectrometry</jtitle><date>2019-09</date><risdate>2019</risdate><volume>48</volume><issue>5</issue><spage>366</spage><epage>374</epage><pages>366-374</pages><issn>0049-8246</issn><eissn>1097-4539</eissn><abstract>A new method based on dispersive microsolid phase extraction using graphene oxide (GO) as a solid adsorbent and total reflection X‐ray fluorescence (TXRF) spectrometry is proposed for trace determination of uranium. In the developed methodology, a suspension of GO was injected into uranium‐spiked multielement solutions including rubidium; after filtration, the membrane filter with collected GO was placed in a small volume of internal standard acid solution and the eluent containing uranium was deposited onto a fluorine resin‐coated slide glass, which is a disposable sample stage. Using GO was effective for removal of rubidium from the measurement solution to avoid interference between Rb Kα peak and U Lα peak. The high enrichment factor of 150 enables obtaining uranium detection limits of 0.042, 0.087, and 0.12 μg L−1 for ionic strength of 0.01, 0.1, and 1 mol L−1, respectively. Such low detection limits were obtained by using a benchtop TXRF spectrometer with 5‐min measurement. The proposed method is suitable for trace uranium determination in water, including high salinity samples.</abstract><cop>Bognor Regis</cop><pub>Wiley Subscription Services, Inc</pub><doi>10.1002/xrs.3032</doi><tpages>9</tpages><orcidid>https://orcid.org/0000-0002-5848-7654</orcidid><orcidid>https://orcid.org/0000-0001-5952-7673</orcidid><orcidid>https://orcid.org/0000-0003-3410-2868</orcidid><orcidid>https://orcid.org/0000-0002-9116-5876</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0049-8246 |
ispartof | X-ray spectrometry, 2019-09, Vol.48 (5), p.366-374 |
issn | 0049-8246 1097-4539 |
language | eng |
recordid | cdi_proquest_journals_2280180901 |
source | Access via Wiley Online Library |
subjects | Detection limits Fluorescence Fluorine Graphene Ions Reflection Rubidium Scientific imaging Spectrometry Spectroscopy Uranium |
title | Trace determination of uranium preconcentrated using graphene oxide by total reflection X‐ray fluorescence spectrometry |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T15%3A46%3A47IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Trace%20determination%20of%20uranium%20preconcentrated%20using%20graphene%20oxide%20by%20total%20reflection%20X%E2%80%90ray%20fluorescence%20spectrometry&rft.jtitle=X-ray%20spectrometry&rft.au=Takahashi,%20Hiroaki&rft.date=2019-09&rft.volume=48&rft.issue=5&rft.spage=366&rft.epage=374&rft.pages=366-374&rft.issn=0049-8246&rft.eissn=1097-4539&rft_id=info:doi/10.1002/xrs.3032&rft_dat=%3Cproquest_cross%3E2280180901%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2280180901&rft_id=info:pmid/&rfr_iscdi=true |