ECHOCARDIOGRAPHIC FLOW FIELD VISUALIZATION DURING MECHANICAL CIRCULATORY SUPPORT IN THE ISOLATED ASSISTED HEART
Intraventricular flow patterns during mechanical circulatory support (MCS) cannot be accessed by clinical imaging; therefore, either computational or in-vitro models are used. However, the complex anatomy of the heart cannot be replicated and simulations inherently rely on assumptions and simplifica...
Gespeichert in:
Veröffentlicht in: | International journal of artificial organs 2019-08, Vol.42 (8) |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | 8 |
container_start_page | |
container_title | International journal of artificial organs |
container_volume | 42 |
creator | Aigner, P Schweiger, M Fraser, K Lemme, F Cesarovic, N Schima, H Hübler, M Granegger, M |
description | Intraventricular flow patterns during mechanical circulatory support (MCS) cannot be accessed by clinical imaging; therefore, either computational or in-vitro models are used. However, the complex anatomy of the heart cannot be replicated and simulations inherently rely on assumptions and simplifications. In an isolated porcine heart setup the feasibility of flow measurements by Echocardiographic Particle Image Velocimetry (E-PIV) was evaluated. Similar to cardiac transplantation, porcine hearts (n=8, animal weight: 80-106 kg) were excised and connected to the isolated heart setup. After resuscitation using blood as perfusate, a rotary blood pump was implanted, microbubbles were injected via the left atrium at different support situations and echocardiographic 3-chamber-view B-mode images were recorded with the highest possible frame rate of up to 141 Hz (Philips iE33, X5-1 xMatrix probe). By iterative PIV algorithms using correlation domain averaging and beam sweep correction, flow fields were evaluated for the different hemodynamic situations. All hearts were successfully resuscitated in the isolated heart setup and different hemodynamic situations were adjusted. In the unsupported heart physiologic flow patterns with a large clockwise vortex structure that warrants washout of the whole cardiac chamber were found. With increasing MCS (2200-2700 rpm) the formation of this flow feature is diminished caused by the additional flow sink at the apex. In full support, without aortic valve opening in the left ventricular outflow tract, a stagnant structure was identified, that might be connected to thromboembolic events. For the first time, the contribution of the mitral valve apparatus to blood flow patterns especially in the LVOT, which may be linked to energy loss, thrombus formation and valve deterioration during MCS was investigated under realistic conditions. |
format | Article |
fullrecord | <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_journals_2279799510</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2279799510</sourcerecordid><originalsourceid>FETCH-proquest_journals_22797995103</originalsourceid><addsrcrecordid>eNqNi82KwjAURsOgMHVm3uGC60L6ozXLS5qaC7EpSao4G5mFsxCxavX9reADuDofnO98sCgp0jye85yPWMQzkcSZWCw-2aTvD5wn8zyfRaxTUluJriS7dNhoklAZu4GKlClhTb5FQ78YyNZQto7qJayGBGuSaECSk63BYN0WfNs01gWgGoJWQN4OQpWA3pN_Dq3QhW82_v879vufF7_YtFJB6vh87S73fX_bHbr79TSoXZoWohBilvDsvdcDn05BOQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2279799510</pqid></control><display><type>article</type><title>ECHOCARDIOGRAPHIC FLOW FIELD VISUALIZATION DURING MECHANICAL CIRCULATORY SUPPORT IN THE ISOLATED ASSISTED HEART</title><source>SAGE Complete</source><creator>Aigner, P ; Schweiger, M ; Fraser, K ; Lemme, F ; Cesarovic, N ; Schima, H ; Hübler, M ; Granegger, M</creator><creatorcontrib>Aigner, P ; Schweiger, M ; Fraser, K ; Lemme, F ; Cesarovic, N ; Schima, H ; Hübler, M ; Granegger, M</creatorcontrib><description>Intraventricular flow patterns during mechanical circulatory support (MCS) cannot be accessed by clinical imaging; therefore, either computational or in-vitro models are used. However, the complex anatomy of the heart cannot be replicated and simulations inherently rely on assumptions and simplifications. In an isolated porcine heart setup the feasibility of flow measurements by Echocardiographic Particle Image Velocimetry (E-PIV) was evaluated. Similar to cardiac transplantation, porcine hearts (n=8, animal weight: 80-106 kg) were excised and connected to the isolated heart setup. After resuscitation using blood as perfusate, a rotary blood pump was implanted, microbubbles were injected via the left atrium at different support situations and echocardiographic 3-chamber-view B-mode images were recorded with the highest possible frame rate of up to 141 Hz (Philips iE33, X5-1 xMatrix probe). By iterative PIV algorithms using correlation domain averaging and beam sweep correction, flow fields were evaluated for the different hemodynamic situations. All hearts were successfully resuscitated in the isolated heart setup and different hemodynamic situations were adjusted. In the unsupported heart physiologic flow patterns with a large clockwise vortex structure that warrants washout of the whole cardiac chamber were found. With increasing MCS (2200-2700 rpm) the formation of this flow feature is diminished caused by the additional flow sink at the apex. In full support, without aortic valve opening in the left ventricular outflow tract, a stagnant structure was identified, that might be connected to thromboembolic events. For the first time, the contribution of the mitral valve apparatus to blood flow patterns especially in the LVOT, which may be linked to energy loss, thrombus formation and valve deterioration during MCS was investigated under realistic conditions.</description><identifier>ISSN: 0391-3988</identifier><identifier>EISSN: 1724-6040</identifier><language>eng</language><publisher>Milan: Wichtig Editore s.r.l</publisher><subject>Algorithms ; Aortic valve ; Atria ; Atrium ; Blood flow ; Blood pumps ; Computational fluid dynamics ; Computer applications ; Computer simulation ; Energy dissipation ; Energy loss ; Feasibility studies ; Heart ; Heart transplantation ; Heart transplants ; Heart valves ; Hemodynamics ; Iterative methods ; Mitral valve ; Particle image velocimetry ; Resuscitation ; Thromboembolism ; Thrombosis ; Transplantation ; Velocity measurement ; Ventricle</subject><ispartof>International journal of artificial organs, 2019-08, Vol.42 (8)</ispartof><rights>Copyright Wichtig Editore s.r.l. Aug 2019</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780</link.rule.ids></links><search><creatorcontrib>Aigner, P</creatorcontrib><creatorcontrib>Schweiger, M</creatorcontrib><creatorcontrib>Fraser, K</creatorcontrib><creatorcontrib>Lemme, F</creatorcontrib><creatorcontrib>Cesarovic, N</creatorcontrib><creatorcontrib>Schima, H</creatorcontrib><creatorcontrib>Hübler, M</creatorcontrib><creatorcontrib>Granegger, M</creatorcontrib><title>ECHOCARDIOGRAPHIC FLOW FIELD VISUALIZATION DURING MECHANICAL CIRCULATORY SUPPORT IN THE ISOLATED ASSISTED HEART</title><title>International journal of artificial organs</title><description>Intraventricular flow patterns during mechanical circulatory support (MCS) cannot be accessed by clinical imaging; therefore, either computational or in-vitro models are used. However, the complex anatomy of the heart cannot be replicated and simulations inherently rely on assumptions and simplifications. In an isolated porcine heart setup the feasibility of flow measurements by Echocardiographic Particle Image Velocimetry (E-PIV) was evaluated. Similar to cardiac transplantation, porcine hearts (n=8, animal weight: 80-106 kg) were excised and connected to the isolated heart setup. After resuscitation using blood as perfusate, a rotary blood pump was implanted, microbubbles were injected via the left atrium at different support situations and echocardiographic 3-chamber-view B-mode images were recorded with the highest possible frame rate of up to 141 Hz (Philips iE33, X5-1 xMatrix probe). By iterative PIV algorithms using correlation domain averaging and beam sweep correction, flow fields were evaluated for the different hemodynamic situations. All hearts were successfully resuscitated in the isolated heart setup and different hemodynamic situations were adjusted. In the unsupported heart physiologic flow patterns with a large clockwise vortex structure that warrants washout of the whole cardiac chamber were found. With increasing MCS (2200-2700 rpm) the formation of this flow feature is diminished caused by the additional flow sink at the apex. In full support, without aortic valve opening in the left ventricular outflow tract, a stagnant structure was identified, that might be connected to thromboembolic events. For the first time, the contribution of the mitral valve apparatus to blood flow patterns especially in the LVOT, which may be linked to energy loss, thrombus formation and valve deterioration during MCS was investigated under realistic conditions.</description><subject>Algorithms</subject><subject>Aortic valve</subject><subject>Atria</subject><subject>Atrium</subject><subject>Blood flow</subject><subject>Blood pumps</subject><subject>Computational fluid dynamics</subject><subject>Computer applications</subject><subject>Computer simulation</subject><subject>Energy dissipation</subject><subject>Energy loss</subject><subject>Feasibility studies</subject><subject>Heart</subject><subject>Heart transplantation</subject><subject>Heart transplants</subject><subject>Heart valves</subject><subject>Hemodynamics</subject><subject>Iterative methods</subject><subject>Mitral valve</subject><subject>Particle image velocimetry</subject><subject>Resuscitation</subject><subject>Thromboembolism</subject><subject>Thrombosis</subject><subject>Transplantation</subject><subject>Velocity measurement</subject><subject>Ventricle</subject><issn>0391-3988</issn><issn>1724-6040</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNqNi82KwjAURsOgMHVm3uGC60L6ozXLS5qaC7EpSao4G5mFsxCxavX9reADuDofnO98sCgp0jye85yPWMQzkcSZWCw-2aTvD5wn8zyfRaxTUluJriS7dNhoklAZu4GKlClhTb5FQ78YyNZQto7qJayGBGuSaECSk63BYN0WfNs01gWgGoJWQN4OQpWA3pN_Dq3QhW82_v879vufF7_YtFJB6vh87S73fX_bHbr79TSoXZoWohBilvDsvdcDn05BOQ</recordid><startdate>20190801</startdate><enddate>20190801</enddate><creator>Aigner, P</creator><creator>Schweiger, M</creator><creator>Fraser, K</creator><creator>Lemme, F</creator><creator>Cesarovic, N</creator><creator>Schima, H</creator><creator>Hübler, M</creator><creator>Granegger, M</creator><general>Wichtig Editore s.r.l</general><scope>7QF</scope><scope>7QO</scope><scope>7QQ</scope><scope>7SC</scope><scope>7SE</scope><scope>7SP</scope><scope>7SR</scope><scope>7TA</scope><scope>7TB</scope><scope>7U5</scope><scope>8BQ</scope><scope>8FD</scope><scope>F28</scope><scope>FR3</scope><scope>H8D</scope><scope>H8G</scope><scope>JG9</scope><scope>JQ2</scope><scope>KR7</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope><scope>P64</scope></search><sort><creationdate>20190801</creationdate><title>ECHOCARDIOGRAPHIC FLOW FIELD VISUALIZATION DURING MECHANICAL CIRCULATORY SUPPORT IN THE ISOLATED ASSISTED HEART</title><author>Aigner, P ; Schweiger, M ; Fraser, K ; Lemme, F ; Cesarovic, N ; Schima, H ; Hübler, M ; Granegger, M</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_journals_22797995103</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Algorithms</topic><topic>Aortic valve</topic><topic>Atria</topic><topic>Atrium</topic><topic>Blood flow</topic><topic>Blood pumps</topic><topic>Computational fluid dynamics</topic><topic>Computer applications</topic><topic>Computer simulation</topic><topic>Energy dissipation</topic><topic>Energy loss</topic><topic>Feasibility studies</topic><topic>Heart</topic><topic>Heart transplantation</topic><topic>Heart transplants</topic><topic>Heart valves</topic><topic>Hemodynamics</topic><topic>Iterative methods</topic><topic>Mitral valve</topic><topic>Particle image velocimetry</topic><topic>Resuscitation</topic><topic>Thromboembolism</topic><topic>Thrombosis</topic><topic>Transplantation</topic><topic>Velocity measurement</topic><topic>Ventricle</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Aigner, P</creatorcontrib><creatorcontrib>Schweiger, M</creatorcontrib><creatorcontrib>Fraser, K</creatorcontrib><creatorcontrib>Lemme, F</creatorcontrib><creatorcontrib>Cesarovic, N</creatorcontrib><creatorcontrib>Schima, H</creatorcontrib><creatorcontrib>Hübler, M</creatorcontrib><creatorcontrib>Granegger, M</creatorcontrib><collection>Aluminium Industry Abstracts</collection><collection>Biotechnology Research Abstracts</collection><collection>Ceramic Abstracts</collection><collection>Computer and Information Systems Abstracts</collection><collection>Corrosion Abstracts</collection><collection>Electronics & Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Materials Business File</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>ANTE: Abstracts in New Technology & Engineering</collection><collection>Engineering Research Database</collection><collection>Aerospace Database</collection><collection>Copper Technical Reference Library</collection><collection>Materials Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>Biotechnology and BioEngineering Abstracts</collection><jtitle>International journal of artificial organs</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Aigner, P</au><au>Schweiger, M</au><au>Fraser, K</au><au>Lemme, F</au><au>Cesarovic, N</au><au>Schima, H</au><au>Hübler, M</au><au>Granegger, M</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>ECHOCARDIOGRAPHIC FLOW FIELD VISUALIZATION DURING MECHANICAL CIRCULATORY SUPPORT IN THE ISOLATED ASSISTED HEART</atitle><jtitle>International journal of artificial organs</jtitle><date>2019-08-01</date><risdate>2019</risdate><volume>42</volume><issue>8</issue><issn>0391-3988</issn><eissn>1724-6040</eissn><abstract>Intraventricular flow patterns during mechanical circulatory support (MCS) cannot be accessed by clinical imaging; therefore, either computational or in-vitro models are used. However, the complex anatomy of the heart cannot be replicated and simulations inherently rely on assumptions and simplifications. In an isolated porcine heart setup the feasibility of flow measurements by Echocardiographic Particle Image Velocimetry (E-PIV) was evaluated. Similar to cardiac transplantation, porcine hearts (n=8, animal weight: 80-106 kg) were excised and connected to the isolated heart setup. After resuscitation using blood as perfusate, a rotary blood pump was implanted, microbubbles were injected via the left atrium at different support situations and echocardiographic 3-chamber-view B-mode images were recorded with the highest possible frame rate of up to 141 Hz (Philips iE33, X5-1 xMatrix probe). By iterative PIV algorithms using correlation domain averaging and beam sweep correction, flow fields were evaluated for the different hemodynamic situations. All hearts were successfully resuscitated in the isolated heart setup and different hemodynamic situations were adjusted. In the unsupported heart physiologic flow patterns with a large clockwise vortex structure that warrants washout of the whole cardiac chamber were found. With increasing MCS (2200-2700 rpm) the formation of this flow feature is diminished caused by the additional flow sink at the apex. In full support, without aortic valve opening in the left ventricular outflow tract, a stagnant structure was identified, that might be connected to thromboembolic events. For the first time, the contribution of the mitral valve apparatus to blood flow patterns especially in the LVOT, which may be linked to energy loss, thrombus formation and valve deterioration during MCS was investigated under realistic conditions.</abstract><cop>Milan</cop><pub>Wichtig Editore s.r.l</pub></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0391-3988 |
ispartof | International journal of artificial organs, 2019-08, Vol.42 (8) |
issn | 0391-3988 1724-6040 |
language | eng |
recordid | cdi_proquest_journals_2279799510 |
source | SAGE Complete |
subjects | Algorithms Aortic valve Atria Atrium Blood flow Blood pumps Computational fluid dynamics Computer applications Computer simulation Energy dissipation Energy loss Feasibility studies Heart Heart transplantation Heart transplants Heart valves Hemodynamics Iterative methods Mitral valve Particle image velocimetry Resuscitation Thromboembolism Thrombosis Transplantation Velocity measurement Ventricle |
title | ECHOCARDIOGRAPHIC FLOW FIELD VISUALIZATION DURING MECHANICAL CIRCULATORY SUPPORT IN THE ISOLATED ASSISTED HEART |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-22T04%3A34%3A38IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=ECHOCARDIOGRAPHIC%20FLOW%20FIELD%20VISUALIZATION%20DURING%20MECHANICAL%20CIRCULATORY%20SUPPORT%20IN%20THE%20ISOLATED%20ASSISTED%20HEART&rft.jtitle=International%20journal%20of%20artificial%20organs&rft.au=Aigner,%20P&rft.date=2019-08-01&rft.volume=42&rft.issue=8&rft.issn=0391-3988&rft.eissn=1724-6040&rft_id=info:doi/&rft_dat=%3Cproquest%3E2279799510%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2279799510&rft_id=info:pmid/&rfr_iscdi=true |