Simplified White Blood Cell Differential: An Inexpensive, Smartphone- and Paper-Based Blood Cell Count

Sorting and measuring blood by cell type is extremely valuable clinically and provides physicians with key information for diagnosing many different disease states including: leukemia, autoimmune disorders, and bacterial infections. Despite the value, the present methods are unnecessarily costly and...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE sensors journal 2019-09, Vol.19 (18), p.7822-7828
Hauptverfasser: Bills, Matthew V., Nguyen, Brandon T., Yoon, Jeong-Yeol
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 7828
container_issue 18
container_start_page 7822
container_title IEEE sensors journal
container_volume 19
creator Bills, Matthew V.
Nguyen, Brandon T.
Yoon, Jeong-Yeol
description Sorting and measuring blood by cell type is extremely valuable clinically and provides physicians with key information for diagnosing many different disease states including: leukemia, autoimmune disorders, and bacterial infections. Despite the value, the present methods are unnecessarily costly and inhibitive particularly in resource poor settings, as they require multiple steps of reagent and/or dye additions and subsequent rinsing followed by manual counting using a hemocytometer, or they require a bulky, expensive equipment such as a flow cytometer. While direct on-paper imaging has been considered challenging, paper substrate offers a strong potential to simplify such reagent/dye addition and rinsing. In this paper, three-layer paper-based device is developed to automate such reagent/dye addition and rinsing via capillary action, and separating white blood cells (WBCs) from whole blood samples. Direct on-paper imaging is demonstrated using a commercial microscope attachment to a smartphone coupled with a blue LED and 500 nm long pass optical filter. Image analysis is accomplished using an original MATLAB code, to evaluate the total WBC count, and differential WBC count, i.e., granulocytes (primarily neutrophils) versus agranulocytes (primarily lymphocytes). Only a finger-prick of whole blood is required for this assay. The total assay time from finger-prick to data collection is under five minutes. Comparison with a hemocytometry-based manual counting corroborates the accuracy and effectiveness of the proposed method. This approach could be potentially used to help make blood cell counting technologies more readily available, especially in resource poor and point-of-care settings.
doi_str_mv 10.1109/JSEN.2019.2920235
format Article
fullrecord <record><control><sourceid>proquest_RIE</sourceid><recordid>TN_cdi_proquest_journals_2275601846</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>8727409</ieee_id><sourcerecordid>2463602549</sourcerecordid><originalsourceid>FETCH-LOGICAL-c424t-b9ce94feab2b74456f691b61116f0511ae155af56029e7aa60a0ee862b90403e3</originalsourceid><addsrcrecordid>eNpdkV9rFDEUxYMotq5-AOlLwJc-OGv-TTLpQ6Fdq7YUFVbRt5CZvemmzCbTZKbotzfLLqX2KRfyu-eew0HoLSVzSon-cLW8-DpnhOo504wwXj9Dh7Sum4oq0TzfzpxUgqvfB-hVzrekkKpWL9EB54xxLZtD5JZ-M_TeeVjhX2s_Aj7vY1zhBfQ9_uidgwRh9LY_wWcBXwb4M0DI_h7e4-XGpnFYxwAVtmGFv9sBUnVuc5F6JLKIUxhfoxfO9hne7N8Z-vnp4sfiS3X97fPl4uy66gQTY9XqDrRwYFvWKiFq6aSmraSUSkdqSi2UeNbVkjANylpJLAFoJGs1EYQDn6HTne4wtRtYdcV7sr0Zki9m_5povfn_J_i1uYn3RknVNFQUgeO9QIp3E-TRbHzuSg4bIE7ZMCF5uV4LXdB3T9DbOKVQ4hnGVPFImwLPEN1RXYo5J3APZigx2xbNtkWzbdHsWyw7R7sdDwAPfKOYEkTzf-_qlrs</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2275601846</pqid></control><display><type>article</type><title>Simplified White Blood Cell Differential: An Inexpensive, Smartphone- and Paper-Based Blood Cell Count</title><source>IEEE Electronic Library (IEL)</source><creator>Bills, Matthew V. ; Nguyen, Brandon T. ; Yoon, Jeong-Yeol</creator><creatorcontrib>Bills, Matthew V. ; Nguyen, Brandon T. ; Yoon, Jeong-Yeol</creatorcontrib><description>Sorting and measuring blood by cell type is extremely valuable clinically and provides physicians with key information for diagnosing many different disease states including: leukemia, autoimmune disorders, and bacterial infections. Despite the value, the present methods are unnecessarily costly and inhibitive particularly in resource poor settings, as they require multiple steps of reagent and/or dye additions and subsequent rinsing followed by manual counting using a hemocytometer, or they require a bulky, expensive equipment such as a flow cytometer. While direct on-paper imaging has been considered challenging, paper substrate offers a strong potential to simplify such reagent/dye addition and rinsing. In this paper, three-layer paper-based device is developed to automate such reagent/dye addition and rinsing via capillary action, and separating white blood cells (WBCs) from whole blood samples. Direct on-paper imaging is demonstrated using a commercial microscope attachment to a smartphone coupled with a blue LED and 500 nm long pass optical filter. Image analysis is accomplished using an original MATLAB code, to evaluate the total WBC count, and differential WBC count, i.e., granulocytes (primarily neutrophils) versus agranulocytes (primarily lymphocytes). Only a finger-prick of whole blood is required for this assay. The total assay time from finger-prick to data collection is under five minutes. Comparison with a hemocytometry-based manual counting corroborates the accuracy and effectiveness of the proposed method. This approach could be potentially used to help make blood cell counting technologies more readily available, especially in resource poor and point-of-care settings.</description><identifier>ISSN: 1530-437X</identifier><identifier>EISSN: 1558-1748</identifier><identifier>DOI: 10.1109/JSEN.2019.2920235</identifier><identifier>PMID: 33223968</identifier><identifier>CODEN: ISJEAZ</identifier><language>eng</language><publisher>New York: IEEE</publisher><subject>Acridine orange ; Autoimmune diseases ; Biomembranes ; Blood ; blood count ; Capillarity ; cell identification ; Counting ; Data acquisition ; Dyes ; Fluorescence ; Image analysis ; Image filters ; Leukocytes ; Lymphocytes ; Microfluidics ; Microscopy ; Optical fiber sensors ; Optical filters ; paper microfluidics ; Physicians ; Reagents ; Rinsing ; smartphone ; Smartphones ; Substrates</subject><ispartof>IEEE sensors journal, 2019-09, Vol.19 (18), p.7822-7828</ispartof><rights>Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) 2019</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c424t-b9ce94feab2b74456f691b61116f0511ae155af56029e7aa60a0ee862b90403e3</citedby><cites>FETCH-LOGICAL-c424t-b9ce94feab2b74456f691b61116f0511ae155af56029e7aa60a0ee862b90403e3</cites><orcidid>0000-0002-9305-0204 ; 0000-0001-6371-1027 ; 0000-0002-9720-6472</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/8727409$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>230,314,776,780,792,881,27901,27902,54733</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/8727409$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Bills, Matthew V.</creatorcontrib><creatorcontrib>Nguyen, Brandon T.</creatorcontrib><creatorcontrib>Yoon, Jeong-Yeol</creatorcontrib><title>Simplified White Blood Cell Differential: An Inexpensive, Smartphone- and Paper-Based Blood Cell Count</title><title>IEEE sensors journal</title><addtitle>JSEN</addtitle><description>Sorting and measuring blood by cell type is extremely valuable clinically and provides physicians with key information for diagnosing many different disease states including: leukemia, autoimmune disorders, and bacterial infections. Despite the value, the present methods are unnecessarily costly and inhibitive particularly in resource poor settings, as they require multiple steps of reagent and/or dye additions and subsequent rinsing followed by manual counting using a hemocytometer, or they require a bulky, expensive equipment such as a flow cytometer. While direct on-paper imaging has been considered challenging, paper substrate offers a strong potential to simplify such reagent/dye addition and rinsing. In this paper, three-layer paper-based device is developed to automate such reagent/dye addition and rinsing via capillary action, and separating white blood cells (WBCs) from whole blood samples. Direct on-paper imaging is demonstrated using a commercial microscope attachment to a smartphone coupled with a blue LED and 500 nm long pass optical filter. Image analysis is accomplished using an original MATLAB code, to evaluate the total WBC count, and differential WBC count, i.e., granulocytes (primarily neutrophils) versus agranulocytes (primarily lymphocytes). Only a finger-prick of whole blood is required for this assay. The total assay time from finger-prick to data collection is under five minutes. Comparison with a hemocytometry-based manual counting corroborates the accuracy and effectiveness of the proposed method. This approach could be potentially used to help make blood cell counting technologies more readily available, especially in resource poor and point-of-care settings.</description><subject>Acridine orange</subject><subject>Autoimmune diseases</subject><subject>Biomembranes</subject><subject>Blood</subject><subject>blood count</subject><subject>Capillarity</subject><subject>cell identification</subject><subject>Counting</subject><subject>Data acquisition</subject><subject>Dyes</subject><subject>Fluorescence</subject><subject>Image analysis</subject><subject>Image filters</subject><subject>Leukocytes</subject><subject>Lymphocytes</subject><subject>Microfluidics</subject><subject>Microscopy</subject><subject>Optical fiber sensors</subject><subject>Optical filters</subject><subject>paper microfluidics</subject><subject>Physicians</subject><subject>Reagents</subject><subject>Rinsing</subject><subject>smartphone</subject><subject>Smartphones</subject><subject>Substrates</subject><issn>1530-437X</issn><issn>1558-1748</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><sourceid>RIE</sourceid><recordid>eNpdkV9rFDEUxYMotq5-AOlLwJc-OGv-TTLpQ6Fdq7YUFVbRt5CZvemmzCbTZKbotzfLLqX2KRfyu-eew0HoLSVzSon-cLW8-DpnhOo504wwXj9Dh7Sum4oq0TzfzpxUgqvfB-hVzrekkKpWL9EB54xxLZtD5JZ-M_TeeVjhX2s_Aj7vY1zhBfQ9_uidgwRh9LY_wWcBXwb4M0DI_h7e4-XGpnFYxwAVtmGFv9sBUnVuc5F6JLKIUxhfoxfO9hne7N8Z-vnp4sfiS3X97fPl4uy66gQTY9XqDrRwYFvWKiFq6aSmraSUSkdqSi2UeNbVkjANylpJLAFoJGs1EYQDn6HTne4wtRtYdcV7sr0Zki9m_5povfn_J_i1uYn3RknVNFQUgeO9QIp3E-TRbHzuSg4bIE7ZMCF5uV4LXdB3T9DbOKVQ4hnGVPFImwLPEN1RXYo5J3APZigx2xbNtkWzbdHsWyw7R7sdDwAPfKOYEkTzf-_qlrs</recordid><startdate>20190915</startdate><enddate>20190915</enddate><creator>Bills, Matthew V.</creator><creator>Nguyen, Brandon T.</creator><creator>Yoon, Jeong-Yeol</creator><general>IEEE</general><general>The Institute of Electrical and Electronics Engineers, Inc. (IEEE)</general><scope>97E</scope><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope><scope>7X8</scope><scope>5PM</scope><orcidid>https://orcid.org/0000-0002-9305-0204</orcidid><orcidid>https://orcid.org/0000-0001-6371-1027</orcidid><orcidid>https://orcid.org/0000-0002-9720-6472</orcidid></search><sort><creationdate>20190915</creationdate><title>Simplified White Blood Cell Differential: An Inexpensive, Smartphone- and Paper-Based Blood Cell Count</title><author>Bills, Matthew V. ; Nguyen, Brandon T. ; Yoon, Jeong-Yeol</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c424t-b9ce94feab2b74456f691b61116f0511ae155af56029e7aa60a0ee862b90403e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Acridine orange</topic><topic>Autoimmune diseases</topic><topic>Biomembranes</topic><topic>Blood</topic><topic>blood count</topic><topic>Capillarity</topic><topic>cell identification</topic><topic>Counting</topic><topic>Data acquisition</topic><topic>Dyes</topic><topic>Fluorescence</topic><topic>Image analysis</topic><topic>Image filters</topic><topic>Leukocytes</topic><topic>Lymphocytes</topic><topic>Microfluidics</topic><topic>Microscopy</topic><topic>Optical fiber sensors</topic><topic>Optical filters</topic><topic>paper microfluidics</topic><topic>Physicians</topic><topic>Reagents</topic><topic>Rinsing</topic><topic>smartphone</topic><topic>Smartphones</topic><topic>Substrates</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Bills, Matthew V.</creatorcontrib><creatorcontrib>Nguyen, Brandon T.</creatorcontrib><creatorcontrib>Yoon, Jeong-Yeol</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 2005-present</collection><collection>IEEE All-Society Periodicals Package (ASPP) 1998-Present</collection><collection>IEEE Electronic Library (IEL)</collection><collection>CrossRef</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>IEEE sensors journal</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Bills, Matthew V.</au><au>Nguyen, Brandon T.</au><au>Yoon, Jeong-Yeol</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Simplified White Blood Cell Differential: An Inexpensive, Smartphone- and Paper-Based Blood Cell Count</atitle><jtitle>IEEE sensors journal</jtitle><stitle>JSEN</stitle><date>2019-09-15</date><risdate>2019</risdate><volume>19</volume><issue>18</issue><spage>7822</spage><epage>7828</epage><pages>7822-7828</pages><issn>1530-437X</issn><eissn>1558-1748</eissn><coden>ISJEAZ</coden><abstract>Sorting and measuring blood by cell type is extremely valuable clinically and provides physicians with key information for diagnosing many different disease states including: leukemia, autoimmune disorders, and bacterial infections. Despite the value, the present methods are unnecessarily costly and inhibitive particularly in resource poor settings, as they require multiple steps of reagent and/or dye additions and subsequent rinsing followed by manual counting using a hemocytometer, or they require a bulky, expensive equipment such as a flow cytometer. While direct on-paper imaging has been considered challenging, paper substrate offers a strong potential to simplify such reagent/dye addition and rinsing. In this paper, three-layer paper-based device is developed to automate such reagent/dye addition and rinsing via capillary action, and separating white blood cells (WBCs) from whole blood samples. Direct on-paper imaging is demonstrated using a commercial microscope attachment to a smartphone coupled with a blue LED and 500 nm long pass optical filter. Image analysis is accomplished using an original MATLAB code, to evaluate the total WBC count, and differential WBC count, i.e., granulocytes (primarily neutrophils) versus agranulocytes (primarily lymphocytes). Only a finger-prick of whole blood is required for this assay. The total assay time from finger-prick to data collection is under five minutes. Comparison with a hemocytometry-based manual counting corroborates the accuracy and effectiveness of the proposed method. This approach could be potentially used to help make blood cell counting technologies more readily available, especially in resource poor and point-of-care settings.</abstract><cop>New York</cop><pub>IEEE</pub><pmid>33223968</pmid><doi>10.1109/JSEN.2019.2920235</doi><tpages>7</tpages><orcidid>https://orcid.org/0000-0002-9305-0204</orcidid><orcidid>https://orcid.org/0000-0001-6371-1027</orcidid><orcidid>https://orcid.org/0000-0002-9720-6472</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 1530-437X
ispartof IEEE sensors journal, 2019-09, Vol.19 (18), p.7822-7828
issn 1530-437X
1558-1748
language eng
recordid cdi_proquest_journals_2275601846
source IEEE Electronic Library (IEL)
subjects Acridine orange
Autoimmune diseases
Biomembranes
Blood
blood count
Capillarity
cell identification
Counting
Data acquisition
Dyes
Fluorescence
Image analysis
Image filters
Leukocytes
Lymphocytes
Microfluidics
Microscopy
Optical fiber sensors
Optical filters
paper microfluidics
Physicians
Reagents
Rinsing
smartphone
Smartphones
Substrates
title Simplified White Blood Cell Differential: An Inexpensive, Smartphone- and Paper-Based Blood Cell Count
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-03T03%3A50%3A11IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_RIE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Simplified%20White%20Blood%20Cell%20Differential:%20An%20Inexpensive,%20Smartphone-%20and%20Paper-Based%20Blood%20Cell%20Count&rft.jtitle=IEEE%20sensors%20journal&rft.au=Bills,%20Matthew%20V.&rft.date=2019-09-15&rft.volume=19&rft.issue=18&rft.spage=7822&rft.epage=7828&rft.pages=7822-7828&rft.issn=1530-437X&rft.eissn=1558-1748&rft.coden=ISJEAZ&rft_id=info:doi/10.1109/JSEN.2019.2920235&rft_dat=%3Cproquest_RIE%3E2463602549%3C/proquest_RIE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2275601846&rft_id=info:pmid/33223968&rft_ieee_id=8727409&rfr_iscdi=true