Effect of flow disturbance induced by walking on the performance of personalized ventilation coupled with mixing ventilation

The aim of this work is to investigate the effect of a walking occupant disturbance, on the performance of personalized ventilation (PV). A computational fluid dynamics (CFD) model of an office space with two people was developed. The first occupant was seated while using the PV (4 L/s). The second...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Building and environment 2019-08, Vol.160, p.106217, Article 106217
Hauptverfasser: Al Assaad, Douaa, Ghali, Kamel, Ghaddar, Nesreen
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page 106217
container_title Building and environment
container_volume 160
creator Al Assaad, Douaa
Ghali, Kamel
Ghaddar, Nesreen
description The aim of this work is to investigate the effect of a walking occupant disturbance, on the performance of personalized ventilation (PV). A computational fluid dynamics (CFD) model of an office space with two people was developed. The first occupant was seated while using the PV (4 L/s). The second occupant was walking along a linear path parallel to the PV jet direction. A dynamic mesh was adopted to model the walking motion. The flow field was validated experimentally in a chamber equipped with stationary and walking manikins. The validated CFD model was used to assess the PV jet during the disturbance. Moreover, tracer gas was used to evaluate the breathable air quality of the PV user. CO2 was used to model passive contaminants in the space, while SF6 represented a local contamination source (walking occupant). Results showed that the walking disturbance deteriorated the PV efficiency. When the occupant was at its closest to the seated occupant and PV, turbulence intensities increased to 21%. This enhanced entrainment of contaminants into the jet, causing a decrease of εv by 72% and 56% for CO2 and SF6. When the occupant is at the end of the trajectory, the negative pressure at the back deflected the PV jet away from the breathing zone. This decreased εv by 60% and 45% for CO2 and SF6. A safe distance of 85 cm between the occupants was recommended to preserve air quality. Moreover, using a wider PV of 18.5 cm diameter (15 L/s) increased εv significantly. [Display omitted] •Flow disturbances affected performance of personalized ventilation due to jet mixing & deflection.•Experimental measurements showed an increase in turbulence in the PV jet surrounding.•Breathing air quality dropped by 72% due to increased mixing and species' entrainment into the jet.•Breathing air quality dropped by 60% due to exposure to space airborne pollutants after jet deflection.•A larger PV enhanced IAQ in the BZ by a maximum of 81% compared to a narrower PV.
doi_str_mv 10.1016/j.buildenv.2019.106217
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2274332536</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0360132319304275</els_id><sourcerecordid>2274332536</sourcerecordid><originalsourceid>FETCH-LOGICAL-c379t-8f75c7b11fcc8ddf068dcb2d0fba801ff179aebe124c1fe4e5872474edf0ca603</originalsourceid><addsrcrecordid>eNqFkE1LAzEURYMoWKt_QQKup-ZjOpnulFI_oOBGwV3IJC82dTqpyUxrxR9v6ii4cxXycu7l5SB0TsmIElpcLkdV52oDzWbECJ2kYcGoOEADWgqeFWX-fIgGhBcko5zxY3QS45Kk4ITnA_Q5sxZ0i73FtvZbbFxsu1CpRgN2jek0GFzt8FbVr655wb7B7QLwGoL1YfVNpWS6Rt-o2n0kegNN62rVusRq363rNNu6doFX7n1f8ef9FB1ZVUc4-zmH6Olm9ji9y-YPt_fT63mmuZi0WWnFWIuKUqt1aYwlRWl0xQyxlSoJtZaKiYIKKMs1tZDDuBQsFzkkVKuC8CG66HvXwb91EFu59F1IC0fJmMg5Z2NeJKroKR18jAGsXAe3UmEnKZF703Ipf03LvWnZm07Bqz4I6Q8bB0FG7SC5MS4kt9J491_FFxEtjs8</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2274332536</pqid></control><display><type>article</type><title>Effect of flow disturbance induced by walking on the performance of personalized ventilation coupled with mixing ventilation</title><source>Elsevier ScienceDirect Journals Complete</source><creator>Al Assaad, Douaa ; Ghali, Kamel ; Ghaddar, Nesreen</creator><creatorcontrib>Al Assaad, Douaa ; Ghali, Kamel ; Ghaddar, Nesreen</creatorcontrib><description>The aim of this work is to investigate the effect of a walking occupant disturbance, on the performance of personalized ventilation (PV). A computational fluid dynamics (CFD) model of an office space with two people was developed. The first occupant was seated while using the PV (4 L/s). The second occupant was walking along a linear path parallel to the PV jet direction. A dynamic mesh was adopted to model the walking motion. The flow field was validated experimentally in a chamber equipped with stationary and walking manikins. The validated CFD model was used to assess the PV jet during the disturbance. Moreover, tracer gas was used to evaluate the breathable air quality of the PV user. CO2 was used to model passive contaminants in the space, while SF6 represented a local contamination source (walking occupant). Results showed that the walking disturbance deteriorated the PV efficiency. When the occupant was at its closest to the seated occupant and PV, turbulence intensities increased to 21%. This enhanced entrainment of contaminants into the jet, causing a decrease of εv by 72% and 56% for CO2 and SF6. When the occupant is at the end of the trajectory, the negative pressure at the back deflected the PV jet away from the breathing zone. This decreased εv by 60% and 45% for CO2 and SF6. A safe distance of 85 cm between the occupants was recommended to preserve air quality. Moreover, using a wider PV of 18.5 cm diameter (15 L/s) increased εv significantly. [Display omitted] •Flow disturbances affected performance of personalized ventilation due to jet mixing &amp; deflection.•Experimental measurements showed an increase in turbulence in the PV jet surrounding.•Breathing air quality dropped by 72% due to increased mixing and species' entrainment into the jet.•Breathing air quality dropped by 60% due to exposure to space airborne pollutants after jet deflection.•A larger PV enhanced IAQ in the BZ by a maximum of 81% compared to a narrower PV.</description><identifier>ISSN: 0360-1323</identifier><identifier>EISSN: 1873-684X</identifier><identifier>DOI: 10.1016/j.buildenv.2019.106217</identifier><language>eng</language><publisher>Oxford: Elsevier Ltd</publisher><subject>Aerodynamics ; Air quality ; Carbon dioxide ; Computational fluid dynamics ; Computer applications ; Contaminants ; Contamination ; Disturbance ; Dynamic mesh ; Entrainment ; Finite element method ; Flow disturbance due to walking ; Fluid dynamics ; Fluid flow ; Hydrodynamics ; Indoor air quality ; Mathematical models ; Personalized ventilation ; Sulfur hexafluoride ; Tracer gas ; Turbulence ; Ventilation</subject><ispartof>Building and environment, 2019-08, Vol.160, p.106217, Article 106217</ispartof><rights>2019 Elsevier Ltd</rights><rights>Copyright Elsevier BV Aug 2019</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c379t-8f75c7b11fcc8ddf068dcb2d0fba801ff179aebe124c1fe4e5872474edf0ca603</citedby><cites>FETCH-LOGICAL-c379t-8f75c7b11fcc8ddf068dcb2d0fba801ff179aebe124c1fe4e5872474edf0ca603</cites><orcidid>0000-0002-9536-651X</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.buildenv.2019.106217$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids></links><search><creatorcontrib>Al Assaad, Douaa</creatorcontrib><creatorcontrib>Ghali, Kamel</creatorcontrib><creatorcontrib>Ghaddar, Nesreen</creatorcontrib><title>Effect of flow disturbance induced by walking on the performance of personalized ventilation coupled with mixing ventilation</title><title>Building and environment</title><description>The aim of this work is to investigate the effect of a walking occupant disturbance, on the performance of personalized ventilation (PV). A computational fluid dynamics (CFD) model of an office space with two people was developed. The first occupant was seated while using the PV (4 L/s). The second occupant was walking along a linear path parallel to the PV jet direction. A dynamic mesh was adopted to model the walking motion. The flow field was validated experimentally in a chamber equipped with stationary and walking manikins. The validated CFD model was used to assess the PV jet during the disturbance. Moreover, tracer gas was used to evaluate the breathable air quality of the PV user. CO2 was used to model passive contaminants in the space, while SF6 represented a local contamination source (walking occupant). Results showed that the walking disturbance deteriorated the PV efficiency. When the occupant was at its closest to the seated occupant and PV, turbulence intensities increased to 21%. This enhanced entrainment of contaminants into the jet, causing a decrease of εv by 72% and 56% for CO2 and SF6. When the occupant is at the end of the trajectory, the negative pressure at the back deflected the PV jet away from the breathing zone. This decreased εv by 60% and 45% for CO2 and SF6. A safe distance of 85 cm between the occupants was recommended to preserve air quality. Moreover, using a wider PV of 18.5 cm diameter (15 L/s) increased εv significantly. [Display omitted] •Flow disturbances affected performance of personalized ventilation due to jet mixing &amp; deflection.•Experimental measurements showed an increase in turbulence in the PV jet surrounding.•Breathing air quality dropped by 72% due to increased mixing and species' entrainment into the jet.•Breathing air quality dropped by 60% due to exposure to space airborne pollutants after jet deflection.•A larger PV enhanced IAQ in the BZ by a maximum of 81% compared to a narrower PV.</description><subject>Aerodynamics</subject><subject>Air quality</subject><subject>Carbon dioxide</subject><subject>Computational fluid dynamics</subject><subject>Computer applications</subject><subject>Contaminants</subject><subject>Contamination</subject><subject>Disturbance</subject><subject>Dynamic mesh</subject><subject>Entrainment</subject><subject>Finite element method</subject><subject>Flow disturbance due to walking</subject><subject>Fluid dynamics</subject><subject>Fluid flow</subject><subject>Hydrodynamics</subject><subject>Indoor air quality</subject><subject>Mathematical models</subject><subject>Personalized ventilation</subject><subject>Sulfur hexafluoride</subject><subject>Tracer gas</subject><subject>Turbulence</subject><subject>Ventilation</subject><issn>0360-1323</issn><issn>1873-684X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNqFkE1LAzEURYMoWKt_QQKup-ZjOpnulFI_oOBGwV3IJC82dTqpyUxrxR9v6ii4cxXycu7l5SB0TsmIElpcLkdV52oDzWbECJ2kYcGoOEADWgqeFWX-fIgGhBcko5zxY3QS45Kk4ITnA_Q5sxZ0i73FtvZbbFxsu1CpRgN2jek0GFzt8FbVr655wb7B7QLwGoL1YfVNpWS6Rt-o2n0kegNN62rVusRq363rNNu6doFX7n1f8ef9FB1ZVUc4-zmH6Olm9ji9y-YPt_fT63mmuZi0WWnFWIuKUqt1aYwlRWl0xQyxlSoJtZaKiYIKKMs1tZDDuBQsFzkkVKuC8CG66HvXwb91EFu59F1IC0fJmMg5Z2NeJKroKR18jAGsXAe3UmEnKZF703Ipf03LvWnZm07Bqz4I6Q8bB0FG7SC5MS4kt9J491_FFxEtjs8</recordid><startdate>20190801</startdate><enddate>20190801</enddate><creator>Al Assaad, Douaa</creator><creator>Ghali, Kamel</creator><creator>Ghaddar, Nesreen</creator><general>Elsevier Ltd</general><general>Elsevier BV</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7ST</scope><scope>8FD</scope><scope>C1K</scope><scope>F28</scope><scope>FR3</scope><scope>KR7</scope><scope>SOI</scope><orcidid>https://orcid.org/0000-0002-9536-651X</orcidid></search><sort><creationdate>20190801</creationdate><title>Effect of flow disturbance induced by walking on the performance of personalized ventilation coupled with mixing ventilation</title><author>Al Assaad, Douaa ; Ghali, Kamel ; Ghaddar, Nesreen</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c379t-8f75c7b11fcc8ddf068dcb2d0fba801ff179aebe124c1fe4e5872474edf0ca603</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Aerodynamics</topic><topic>Air quality</topic><topic>Carbon dioxide</topic><topic>Computational fluid dynamics</topic><topic>Computer applications</topic><topic>Contaminants</topic><topic>Contamination</topic><topic>Disturbance</topic><topic>Dynamic mesh</topic><topic>Entrainment</topic><topic>Finite element method</topic><topic>Flow disturbance due to walking</topic><topic>Fluid dynamics</topic><topic>Fluid flow</topic><topic>Hydrodynamics</topic><topic>Indoor air quality</topic><topic>Mathematical models</topic><topic>Personalized ventilation</topic><topic>Sulfur hexafluoride</topic><topic>Tracer gas</topic><topic>Turbulence</topic><topic>Ventilation</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Al Assaad, Douaa</creatorcontrib><creatorcontrib>Ghali, Kamel</creatorcontrib><creatorcontrib>Ghaddar, Nesreen</creatorcontrib><collection>CrossRef</collection><collection>Environment Abstracts</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ANTE: Abstracts in New Technology &amp; Engineering</collection><collection>Engineering Research Database</collection><collection>Civil Engineering Abstracts</collection><collection>Environment Abstracts</collection><jtitle>Building and environment</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Al Assaad, Douaa</au><au>Ghali, Kamel</au><au>Ghaddar, Nesreen</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Effect of flow disturbance induced by walking on the performance of personalized ventilation coupled with mixing ventilation</atitle><jtitle>Building and environment</jtitle><date>2019-08-01</date><risdate>2019</risdate><volume>160</volume><spage>106217</spage><pages>106217-</pages><artnum>106217</artnum><issn>0360-1323</issn><eissn>1873-684X</eissn><abstract>The aim of this work is to investigate the effect of a walking occupant disturbance, on the performance of personalized ventilation (PV). A computational fluid dynamics (CFD) model of an office space with two people was developed. The first occupant was seated while using the PV (4 L/s). The second occupant was walking along a linear path parallel to the PV jet direction. A dynamic mesh was adopted to model the walking motion. The flow field was validated experimentally in a chamber equipped with stationary and walking manikins. The validated CFD model was used to assess the PV jet during the disturbance. Moreover, tracer gas was used to evaluate the breathable air quality of the PV user. CO2 was used to model passive contaminants in the space, while SF6 represented a local contamination source (walking occupant). Results showed that the walking disturbance deteriorated the PV efficiency. When the occupant was at its closest to the seated occupant and PV, turbulence intensities increased to 21%. This enhanced entrainment of contaminants into the jet, causing a decrease of εv by 72% and 56% for CO2 and SF6. When the occupant is at the end of the trajectory, the negative pressure at the back deflected the PV jet away from the breathing zone. This decreased εv by 60% and 45% for CO2 and SF6. A safe distance of 85 cm between the occupants was recommended to preserve air quality. Moreover, using a wider PV of 18.5 cm diameter (15 L/s) increased εv significantly. [Display omitted] •Flow disturbances affected performance of personalized ventilation due to jet mixing &amp; deflection.•Experimental measurements showed an increase in turbulence in the PV jet surrounding.•Breathing air quality dropped by 72% due to increased mixing and species' entrainment into the jet.•Breathing air quality dropped by 60% due to exposure to space airborne pollutants after jet deflection.•A larger PV enhanced IAQ in the BZ by a maximum of 81% compared to a narrower PV.</abstract><cop>Oxford</cop><pub>Elsevier Ltd</pub><doi>10.1016/j.buildenv.2019.106217</doi><orcidid>https://orcid.org/0000-0002-9536-651X</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0360-1323
ispartof Building and environment, 2019-08, Vol.160, p.106217, Article 106217
issn 0360-1323
1873-684X
language eng
recordid cdi_proquest_journals_2274332536
source Elsevier ScienceDirect Journals Complete
subjects Aerodynamics
Air quality
Carbon dioxide
Computational fluid dynamics
Computer applications
Contaminants
Contamination
Disturbance
Dynamic mesh
Entrainment
Finite element method
Flow disturbance due to walking
Fluid dynamics
Fluid flow
Hydrodynamics
Indoor air quality
Mathematical models
Personalized ventilation
Sulfur hexafluoride
Tracer gas
Turbulence
Ventilation
title Effect of flow disturbance induced by walking on the performance of personalized ventilation coupled with mixing ventilation
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-01T04%3A44%3A10IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Effect%20of%20flow%20disturbance%20induced%20by%20walking%20on%20the%20performance%20of%20personalized%20ventilation%20coupled%20with%20mixing%20ventilation&rft.jtitle=Building%20and%20environment&rft.au=Al%20Assaad,%20Douaa&rft.date=2019-08-01&rft.volume=160&rft.spage=106217&rft.pages=106217-&rft.artnum=106217&rft.issn=0360-1323&rft.eissn=1873-684X&rft_id=info:doi/10.1016/j.buildenv.2019.106217&rft_dat=%3Cproquest_cross%3E2274332536%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2274332536&rft_id=info:pmid/&rft_els_id=S0360132319304275&rfr_iscdi=true