Well-founded practice or personal preference: a comparison of established techniques for measuring ulnar variance in healthy children and adolescents

Objectives Ulnar variance is a clinical measure used to determine the relative difference in length between the radius and ulna. We aimed to examine consistency in ulnar variance measurements and normative data in children and adolescents using the perpendicular and the Hafner methods. Methods Two r...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:European radiology 2020-01, Vol.30 (1), p.151-162
Hauptverfasser: Kox, Laura S., Jens, Sjoerd, Lauf, Kenny, Smithuis, Frank F., van Rijn, Rick R., Maas, Mario
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Objectives Ulnar variance is a clinical measure used to determine the relative difference in length between the radius and ulna. We aimed to examine consistency in ulnar variance measurements and normative data in children and adolescents using the perpendicular and the Hafner methods. Methods Two raters measured ulnar variance on hand radiographs of 350 healthy children. Participants’ mean calendar and skeletal ages were 12.3 ± 3.6 and 12.0 ± 3.7 years, 52% were female. Raters used the perpendicular method, an adapted version of the perpendicular method (in which the distal radial articular surface is defined as a sclerotic rim) and the Hafner method, being the distance between the most proximal points of the ulnar and radial metaphyses (PRPR) and the distance between the most distal points of both (DIDI). Intraclass correlation coefficients (ICCs) for intermethod consistency and inter- and intrarater agreement were calculated using a two-way ANOVA model. Variability and limits of agreement were determined using the Bland-Altman method. Results The interrater ICC was 0.75 (95% CI, 0.61–0.84) for the adapted perpendicular method, 0.88 (95% CI, 0.80–0.93) for PRPR, and 0.94 (95% CI, 0.90–0.97) for DIDI. The intermethod consistency ICC was 0.60 (95% CI, 0.48–0.70) for perpendicular versus PRPR and 0.60 (95% CI, 0.49–0.70) for perpendicular versus DIDI. The intrarater ICC was 0.88 (95% CI, 0.70–0.95) for perpendicular, 0.90 (95% CI, 0.83–0.94) for PRPR, and 0.81 (95% CI, 0.69–0.89) for DIDI. The perpendicular method was not useable in 38 cases (skeletal age ≤ 9 years) and the Hafner method in 79 cases (skeletal age ≥ 12 years). Conclusions The perpendicular and Hafner methods show moderate intermethod consistency. The Hafner method is preferred for children with skeletal ages
ISSN:0938-7994
1432-1084
DOI:10.1007/s00330-019-06354-x