Experimental and theoretical study of a water-vapor chamber thermal diode

•A water-vapor chamber thermal diode is studied experimentally and theoretically.•Mathematical models are developed and verified by the experiments.•The maximum diodicity of 1.43 is reported with the water-air volume ratio of 0.5.•The effects of water-air volume ratio of the thermal diode are invest...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International journal of heat and mass transfer 2019-08, Vol.138, p.173-183
Hauptverfasser: Wong, M.Y., Traipattanakul, B., Tso, C.Y., Chao, Christopher Y.H., Qiu, Huihe
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 183
container_issue
container_start_page 173
container_title International journal of heat and mass transfer
container_volume 138
creator Wong, M.Y.
Traipattanakul, B.
Tso, C.Y.
Chao, Christopher Y.H.
Qiu, Huihe
description •A water-vapor chamber thermal diode is studied experimentally and theoretically.•Mathematical models are developed and verified by the experiments.•The maximum diodicity of 1.43 is reported with the water-air volume ratio of 0.5.•The effects of water-air volume ratio of the thermal diode are investigated.•The models can serve as a tool for other phase-change thermal diode applications. Similar to an electrical diode, a thermal diode/switch is a device which allows heat to flow to a preferential direction. While a number of different types of thermal diodes/switches exist, a phase-change thermal diode/switch yields a greater diodicity performance compared to other types. However, most phase-change thermal diodes/switches have complex designs, complicated fabrication processes, and sophisticated working principles. Moreover, some materials used in thermal diodes/switches are rare, expensive and toxic. Thus, in this study, a simple water-vapor chamber thermal diode using latent heat of vaporization is designed, assembled and investigated, both experimentally and theoretically. The effects of the temperature difference between the hot side and the cold side and the water-air volume ratio on the effective thermal conductivity and diodicity of the water-vapor chamber thermal diode are also investigated. Mathematical models are also developed, not only for predicting one-dimensional phase change heat transfer performance in a rigid enclosure, but also for verifying the results from the experiment. This is the first study in which the water-vapor chamber thermal diode is studied both experimentally and theoretically. The experimental results show that an increase in temperature at the hot side of the thermal diode significantly enhances the performance of the thermal diode. The effective thermal conductivity at the hot side temperature of 70 °C shows a 50% improvement when compared with that at the hot side temperature of 40 °C in the forward direction. Additionally, with the water-air volume ratio of 0.5, the maximum diodicity of 1.43 is reported. Moreover, it is also found that the water-vapor volume ratio affects heat transfer performance and diodicity of the water-vapor chamber thermal diode. The results of these findings can further advance knowledge on phase-change heat transfer and can be applied to several applications, including heat transfer enhancement, waste heat power systems, thermal management and solar thermoelectric power generation.
doi_str_mv 10.1016/j.ijheatmasstransfer.2019.04.046
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2253255580</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0017931018359519</els_id><sourcerecordid>2253255580</sourcerecordid><originalsourceid>FETCH-LOGICAL-c407t-e83937911dc13d7a0ee95fb8ea54acb244c44605f942a0f888cd7508782b280a3</originalsourceid><addsrcrecordid>eNqNkE9LAzEQxYMoWKvfYcGLl12TbLKb3JRStVLwoueQTWZplu4fk7Tab29KvXkRBobH_HjDewjdEVwQTKr7rnDdBnTsdQjR6yG04AuKiSwwS1OdoRkRtcwpEfIczTAmdS5Lgi_RVQjdUSZohlbL7wm862GIepvpwWZxA6OH6EzSIe7sIRvbTGdfOoLP93oafWY2um_AH1HfJ8y60cI1umj1NsDN756jj6fl--IlX789rxaP69wwXMccRCnLWhJiDSltrTGA5G0jQHOmTUMZM4xVmLeSUY1bIYSxNceiFrShAutyjm5PvpMfP3cQourGnR_SS0UpLynnXOBEPZwo48cQPLRqSim1PyiC1bFA1am_BapjgQqzNFWyeD1ZQEqzd-kajIPBgHUeTFR2dP83-wH39YYs</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2253255580</pqid></control><display><type>article</type><title>Experimental and theoretical study of a water-vapor chamber thermal diode</title><source>Elsevier ScienceDirect Journals Complete</source><creator>Wong, M.Y. ; Traipattanakul, B. ; Tso, C.Y. ; Chao, Christopher Y.H. ; Qiu, Huihe</creator><creatorcontrib>Wong, M.Y. ; Traipattanakul, B. ; Tso, C.Y. ; Chao, Christopher Y.H. ; Qiu, Huihe</creatorcontrib><description>•A water-vapor chamber thermal diode is studied experimentally and theoretically.•Mathematical models are developed and verified by the experiments.•The maximum diodicity of 1.43 is reported with the water-air volume ratio of 0.5.•The effects of water-air volume ratio of the thermal diode are investigated.•The models can serve as a tool for other phase-change thermal diode applications. Similar to an electrical diode, a thermal diode/switch is a device which allows heat to flow to a preferential direction. While a number of different types of thermal diodes/switches exist, a phase-change thermal diode/switch yields a greater diodicity performance compared to other types. However, most phase-change thermal diodes/switches have complex designs, complicated fabrication processes, and sophisticated working principles. Moreover, some materials used in thermal diodes/switches are rare, expensive and toxic. Thus, in this study, a simple water-vapor chamber thermal diode using latent heat of vaporization is designed, assembled and investigated, both experimentally and theoretically. The effects of the temperature difference between the hot side and the cold side and the water-air volume ratio on the effective thermal conductivity and diodicity of the water-vapor chamber thermal diode are also investigated. Mathematical models are also developed, not only for predicting one-dimensional phase change heat transfer performance in a rigid enclosure, but also for verifying the results from the experiment. This is the first study in which the water-vapor chamber thermal diode is studied both experimentally and theoretically. The experimental results show that an increase in temperature at the hot side of the thermal diode significantly enhances the performance of the thermal diode. The effective thermal conductivity at the hot side temperature of 70 °C shows a 50% improvement when compared with that at the hot side temperature of 40 °C in the forward direction. Additionally, with the water-air volume ratio of 0.5, the maximum diodicity of 1.43 is reported. Moreover, it is also found that the water-vapor volume ratio affects heat transfer performance and diodicity of the water-vapor chamber thermal diode. The results of these findings can further advance knowledge on phase-change heat transfer and can be applied to several applications, including heat transfer enhancement, waste heat power systems, thermal management and solar thermoelectric power generation.</description><identifier>ISSN: 0017-9310</identifier><identifier>EISSN: 1879-2189</identifier><identifier>DOI: 10.1016/j.ijheatmasstransfer.2019.04.046</identifier><language>eng</language><publisher>Oxford: Elsevier Ltd</publisher><subject>Diodes ; Diodicity ; Effective thermal conductivity ; Electric power systems ; Electrical resistivity ; Heat conductivity ; Heat of vaporization ; Heat transfer ; Knowledge management ; Latent heat ; Phase change ; Phase transitions ; Switches ; Temperature gradients ; Thermal conductivity ; Thermal diode ; Thermal energy ; Thermal management ; Thermal rectification ; Thermoelectric power generation ; Vapors</subject><ispartof>International journal of heat and mass transfer, 2019-08, Vol.138, p.173-183</ispartof><rights>2019</rights><rights>Copyright Elsevier BV Aug 2019</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c407t-e83937911dc13d7a0ee95fb8ea54acb244c44605f942a0f888cd7508782b280a3</citedby><cites>FETCH-LOGICAL-c407t-e83937911dc13d7a0ee95fb8ea54acb244c44605f942a0f888cd7508782b280a3</cites><orcidid>0000-0001-5238-2352</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0017931018359519$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids></links><search><creatorcontrib>Wong, M.Y.</creatorcontrib><creatorcontrib>Traipattanakul, B.</creatorcontrib><creatorcontrib>Tso, C.Y.</creatorcontrib><creatorcontrib>Chao, Christopher Y.H.</creatorcontrib><creatorcontrib>Qiu, Huihe</creatorcontrib><title>Experimental and theoretical study of a water-vapor chamber thermal diode</title><title>International journal of heat and mass transfer</title><description>•A water-vapor chamber thermal diode is studied experimentally and theoretically.•Mathematical models are developed and verified by the experiments.•The maximum diodicity of 1.43 is reported with the water-air volume ratio of 0.5.•The effects of water-air volume ratio of the thermal diode are investigated.•The models can serve as a tool for other phase-change thermal diode applications. Similar to an electrical diode, a thermal diode/switch is a device which allows heat to flow to a preferential direction. While a number of different types of thermal diodes/switches exist, a phase-change thermal diode/switch yields a greater diodicity performance compared to other types. However, most phase-change thermal diodes/switches have complex designs, complicated fabrication processes, and sophisticated working principles. Moreover, some materials used in thermal diodes/switches are rare, expensive and toxic. Thus, in this study, a simple water-vapor chamber thermal diode using latent heat of vaporization is designed, assembled and investigated, both experimentally and theoretically. The effects of the temperature difference between the hot side and the cold side and the water-air volume ratio on the effective thermal conductivity and diodicity of the water-vapor chamber thermal diode are also investigated. Mathematical models are also developed, not only for predicting one-dimensional phase change heat transfer performance in a rigid enclosure, but also for verifying the results from the experiment. This is the first study in which the water-vapor chamber thermal diode is studied both experimentally and theoretically. The experimental results show that an increase in temperature at the hot side of the thermal diode significantly enhances the performance of the thermal diode. The effective thermal conductivity at the hot side temperature of 70 °C shows a 50% improvement when compared with that at the hot side temperature of 40 °C in the forward direction. Additionally, with the water-air volume ratio of 0.5, the maximum diodicity of 1.43 is reported. Moreover, it is also found that the water-vapor volume ratio affects heat transfer performance and diodicity of the water-vapor chamber thermal diode. The results of these findings can further advance knowledge on phase-change heat transfer and can be applied to several applications, including heat transfer enhancement, waste heat power systems, thermal management and solar thermoelectric power generation.</description><subject>Diodes</subject><subject>Diodicity</subject><subject>Effective thermal conductivity</subject><subject>Electric power systems</subject><subject>Electrical resistivity</subject><subject>Heat conductivity</subject><subject>Heat of vaporization</subject><subject>Heat transfer</subject><subject>Knowledge management</subject><subject>Latent heat</subject><subject>Phase change</subject><subject>Phase transitions</subject><subject>Switches</subject><subject>Temperature gradients</subject><subject>Thermal conductivity</subject><subject>Thermal diode</subject><subject>Thermal energy</subject><subject>Thermal management</subject><subject>Thermal rectification</subject><subject>Thermoelectric power generation</subject><subject>Vapors</subject><issn>0017-9310</issn><issn>1879-2189</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNqNkE9LAzEQxYMoWKvfYcGLl12TbLKb3JRStVLwoueQTWZplu4fk7Tab29KvXkRBobH_HjDewjdEVwQTKr7rnDdBnTsdQjR6yG04AuKiSwwS1OdoRkRtcwpEfIczTAmdS5Lgi_RVQjdUSZohlbL7wm862GIepvpwWZxA6OH6EzSIe7sIRvbTGdfOoLP93oafWY2um_AH1HfJ8y60cI1umj1NsDN756jj6fl--IlX789rxaP69wwXMccRCnLWhJiDSltrTGA5G0jQHOmTUMZM4xVmLeSUY1bIYSxNceiFrShAutyjm5PvpMfP3cQourGnR_SS0UpLynnXOBEPZwo48cQPLRqSim1PyiC1bFA1am_BapjgQqzNFWyeD1ZQEqzd-kajIPBgHUeTFR2dP83-wH39YYs</recordid><startdate>20190801</startdate><enddate>20190801</enddate><creator>Wong, M.Y.</creator><creator>Traipattanakul, B.</creator><creator>Tso, C.Y.</creator><creator>Chao, Christopher Y.H.</creator><creator>Qiu, Huihe</creator><general>Elsevier Ltd</general><general>Elsevier BV</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7TB</scope><scope>8FD</scope><scope>FR3</scope><scope>H8D</scope><scope>KR7</scope><scope>L7M</scope><orcidid>https://orcid.org/0000-0001-5238-2352</orcidid></search><sort><creationdate>20190801</creationdate><title>Experimental and theoretical study of a water-vapor chamber thermal diode</title><author>Wong, M.Y. ; Traipattanakul, B. ; Tso, C.Y. ; Chao, Christopher Y.H. ; Qiu, Huihe</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c407t-e83937911dc13d7a0ee95fb8ea54acb244c44605f942a0f888cd7508782b280a3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Diodes</topic><topic>Diodicity</topic><topic>Effective thermal conductivity</topic><topic>Electric power systems</topic><topic>Electrical resistivity</topic><topic>Heat conductivity</topic><topic>Heat of vaporization</topic><topic>Heat transfer</topic><topic>Knowledge management</topic><topic>Latent heat</topic><topic>Phase change</topic><topic>Phase transitions</topic><topic>Switches</topic><topic>Temperature gradients</topic><topic>Thermal conductivity</topic><topic>Thermal diode</topic><topic>Thermal energy</topic><topic>Thermal management</topic><topic>Thermal rectification</topic><topic>Thermoelectric power generation</topic><topic>Vapors</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Wong, M.Y.</creatorcontrib><creatorcontrib>Traipattanakul, B.</creatorcontrib><creatorcontrib>Tso, C.Y.</creatorcontrib><creatorcontrib>Chao, Christopher Y.H.</creatorcontrib><creatorcontrib>Qiu, Huihe</creatorcontrib><collection>CrossRef</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Aerospace Database</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>International journal of heat and mass transfer</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Wong, M.Y.</au><au>Traipattanakul, B.</au><au>Tso, C.Y.</au><au>Chao, Christopher Y.H.</au><au>Qiu, Huihe</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Experimental and theoretical study of a water-vapor chamber thermal diode</atitle><jtitle>International journal of heat and mass transfer</jtitle><date>2019-08-01</date><risdate>2019</risdate><volume>138</volume><spage>173</spage><epage>183</epage><pages>173-183</pages><issn>0017-9310</issn><eissn>1879-2189</eissn><abstract>•A water-vapor chamber thermal diode is studied experimentally and theoretically.•Mathematical models are developed and verified by the experiments.•The maximum diodicity of 1.43 is reported with the water-air volume ratio of 0.5.•The effects of water-air volume ratio of the thermal diode are investigated.•The models can serve as a tool for other phase-change thermal diode applications. Similar to an electrical diode, a thermal diode/switch is a device which allows heat to flow to a preferential direction. While a number of different types of thermal diodes/switches exist, a phase-change thermal diode/switch yields a greater diodicity performance compared to other types. However, most phase-change thermal diodes/switches have complex designs, complicated fabrication processes, and sophisticated working principles. Moreover, some materials used in thermal diodes/switches are rare, expensive and toxic. Thus, in this study, a simple water-vapor chamber thermal diode using latent heat of vaporization is designed, assembled and investigated, both experimentally and theoretically. The effects of the temperature difference between the hot side and the cold side and the water-air volume ratio on the effective thermal conductivity and diodicity of the water-vapor chamber thermal diode are also investigated. Mathematical models are also developed, not only for predicting one-dimensional phase change heat transfer performance in a rigid enclosure, but also for verifying the results from the experiment. This is the first study in which the water-vapor chamber thermal diode is studied both experimentally and theoretically. The experimental results show that an increase in temperature at the hot side of the thermal diode significantly enhances the performance of the thermal diode. The effective thermal conductivity at the hot side temperature of 70 °C shows a 50% improvement when compared with that at the hot side temperature of 40 °C in the forward direction. Additionally, with the water-air volume ratio of 0.5, the maximum diodicity of 1.43 is reported. Moreover, it is also found that the water-vapor volume ratio affects heat transfer performance and diodicity of the water-vapor chamber thermal diode. The results of these findings can further advance knowledge on phase-change heat transfer and can be applied to several applications, including heat transfer enhancement, waste heat power systems, thermal management and solar thermoelectric power generation.</abstract><cop>Oxford</cop><pub>Elsevier Ltd</pub><doi>10.1016/j.ijheatmasstransfer.2019.04.046</doi><tpages>11</tpages><orcidid>https://orcid.org/0000-0001-5238-2352</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0017-9310
ispartof International journal of heat and mass transfer, 2019-08, Vol.138, p.173-183
issn 0017-9310
1879-2189
language eng
recordid cdi_proquest_journals_2253255580
source Elsevier ScienceDirect Journals Complete
subjects Diodes
Diodicity
Effective thermal conductivity
Electric power systems
Electrical resistivity
Heat conductivity
Heat of vaporization
Heat transfer
Knowledge management
Latent heat
Phase change
Phase transitions
Switches
Temperature gradients
Thermal conductivity
Thermal diode
Thermal energy
Thermal management
Thermal rectification
Thermoelectric power generation
Vapors
title Experimental and theoretical study of a water-vapor chamber thermal diode
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-29T20%3A03%3A03IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Experimental%20and%20theoretical%20study%20of%20a%20water-vapor%20chamber%20thermal%20diode&rft.jtitle=International%20journal%20of%20heat%20and%20mass%20transfer&rft.au=Wong,%20M.Y.&rft.date=2019-08-01&rft.volume=138&rft.spage=173&rft.epage=183&rft.pages=173-183&rft.issn=0017-9310&rft.eissn=1879-2189&rft_id=info:doi/10.1016/j.ijheatmasstransfer.2019.04.046&rft_dat=%3Cproquest_cross%3E2253255580%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2253255580&rft_id=info:pmid/&rft_els_id=S0017931018359519&rfr_iscdi=true