Charge collection efficiency in photoconductive detectors under small to large signals
Hecht collection efficiency η0 and its formulations for exponential absorption have been widely used in modeling charge collection efficiency in photoconductive detectors. The basic assumption of the Hecht formulation is that the electric field in the device is uniform, i.e., the photoinjected carri...
Gespeichert in:
Veröffentlicht in: | Journal of applied physics 2019-06, Vol.125 (24) |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | 24 |
container_start_page | |
container_title | Journal of applied physics |
container_volume | 125 |
creator | Ramaswami, Kieran Johanson, Robert Kasap, Safa |
description | Hecht collection efficiency η0 and its formulations for exponential absorption have been widely used in modeling charge collection efficiency in photoconductive detectors. The basic assumption of the Hecht formulation is that the electric field in the device is uniform, i.e., the photoinjected carriers do not perturb the field. Here, we have used Monte Carlo simulations to model the initial injection of electron and hole pairs and their subsequent transport and trapping in the presence of an electric field, which is calculated from the Poisson equation. Each injected carrier is tracked as it moves in the semiconductor until it is either trapped or reaches the collection electrode. Trapped carriers do not contribute to the photocurrent but continue to contribute to the field through the Poisson equation. The instantaneous photocurrent iph(t) is calculated from the drift of the free carriers through the Shockley–Ramo theorem. iph(t) is integrated over the duration of the photocurrent to calculate the total collected charge and hence the collection efficiency ηr. ηr has been calculated as a function of the charge injection ratio r, the electron and hole ranges (drift mobility and lifetime products, μτ), mean photoinjection depth δ, and drift mobility ratio b. The deviation of the collection efficiency ηr from the uniform field case η0 can be as much as 30% smaller than the small signal model prediction. However, for a wide range of electron and hole schubwegs and photoinjection ratios, typical errors remained less than 10% at full injection, the worst case. The present study provides partial justification to the wide-spread use of the uniform-field collection efficiency η0 formula in various applications, even under high injection conditions. |
doi_str_mv | 10.1063/1.5096900 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2248705056</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2248705056</sourcerecordid><originalsourceid>FETCH-LOGICAL-c327t-8e43efaf337c083986969baa4b3f7fc5a4c768b8153fdd9ff2d2c61ab618b4a83</originalsourceid><addsrcrecordid>eNp90M1LwzAYBvAgCs7pwf8g4Emh803TJulRhl8geFGvIc3H1tE1NWkH--_N3NCD4Ok9vD8eHh6ELgnMCDB6S2YlVKwCOEITAqLKeFnCMZoA5CQTFa9O0VmMKwBCBK0m6GO-VGFhsfZta_XQ-A5b5xrd2E5vcdPhfukHr31nxvTdWGzskJwPEY-dsQHHtWpbPHjcfufEZtGpNp6jE5eOvTjcKXp_uH-bP2Uvr4_P87uXTNOcD5mwBbVOOUq5htRHsNS9VqqoqeNOl6rQnIlakJI6YyrncpNrRlTNiKgLJegUXe1z--A_RxsHufJj2DWQeV4IDiWULKnrvdLBxxisk31o1ipsJQG5m00SeZgt2Zu9jboZ1G6QH7zx4RfK3rj_8N_kL2QrfI0</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2248705056</pqid></control><display><type>article</type><title>Charge collection efficiency in photoconductive detectors under small to large signals</title><source>AIP Journals Complete</source><source>Alma/SFX Local Collection</source><creator>Ramaswami, Kieran ; Johanson, Robert ; Kasap, Safa</creator><creatorcontrib>Ramaswami, Kieran ; Johanson, Robert ; Kasap, Safa</creatorcontrib><description>Hecht collection efficiency η0 and its formulations for exponential absorption have been widely used in modeling charge collection efficiency in photoconductive detectors. The basic assumption of the Hecht formulation is that the electric field in the device is uniform, i.e., the photoinjected carriers do not perturb the field. Here, we have used Monte Carlo simulations to model the initial injection of electron and hole pairs and their subsequent transport and trapping in the presence of an electric field, which is calculated from the Poisson equation. Each injected carrier is tracked as it moves in the semiconductor until it is either trapped or reaches the collection electrode. Trapped carriers do not contribute to the photocurrent but continue to contribute to the field through the Poisson equation. The instantaneous photocurrent iph(t) is calculated from the drift of the free carriers through the Shockley–Ramo theorem. iph(t) is integrated over the duration of the photocurrent to calculate the total collected charge and hence the collection efficiency ηr. ηr has been calculated as a function of the charge injection ratio r, the electron and hole ranges (drift mobility and lifetime products, μτ), mean photoinjection depth δ, and drift mobility ratio b. The deviation of the collection efficiency ηr from the uniform field case η0 can be as much as 30% smaller than the small signal model prediction. However, for a wide range of electron and hole schubwegs and photoinjection ratios, typical errors remained less than 10% at full injection, the worst case. The present study provides partial justification to the wide-spread use of the uniform-field collection efficiency η0 formula in various applications, even under high injection conditions.</description><identifier>ISSN: 0021-8979</identifier><identifier>EISSN: 1089-7550</identifier><identifier>DOI: 10.1063/1.5096900</identifier><identifier>CODEN: JAPIAU</identifier><language>eng</language><publisher>Melville: American Institute of Physics</publisher><subject>Applied physics ; Charge efficiency ; Charge injection ; Collection ; Computer simulation ; Detectors ; Drift ; Efficiency ; Electric fields ; Electrons ; Formulations ; Photoelectric effect ; Photoelectric emission ; Poisson equation</subject><ispartof>Journal of applied physics, 2019-06, Vol.125 (24)</ispartof><rights>Author(s)</rights><rights>2019 Author(s). Published under license by AIP Publishing.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c327t-8e43efaf337c083986969baa4b3f7fc5a4c768b8153fdd9ff2d2c61ab618b4a83</citedby><cites>FETCH-LOGICAL-c327t-8e43efaf337c083986969baa4b3f7fc5a4c768b8153fdd9ff2d2c61ab618b4a83</cites><orcidid>0000-0001-5761-8352 ; 0000-0002-2392-3954</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://pubs.aip.org/jap/article-lookup/doi/10.1063/1.5096900$$EHTML$$P50$$Gscitation$$H</linktohtml><link.rule.ids>314,780,784,794,4512,27924,27925,76384</link.rule.ids></links><search><creatorcontrib>Ramaswami, Kieran</creatorcontrib><creatorcontrib>Johanson, Robert</creatorcontrib><creatorcontrib>Kasap, Safa</creatorcontrib><title>Charge collection efficiency in photoconductive detectors under small to large signals</title><title>Journal of applied physics</title><description>Hecht collection efficiency η0 and its formulations for exponential absorption have been widely used in modeling charge collection efficiency in photoconductive detectors. The basic assumption of the Hecht formulation is that the electric field in the device is uniform, i.e., the photoinjected carriers do not perturb the field. Here, we have used Monte Carlo simulations to model the initial injection of electron and hole pairs and their subsequent transport and trapping in the presence of an electric field, which is calculated from the Poisson equation. Each injected carrier is tracked as it moves in the semiconductor until it is either trapped or reaches the collection electrode. Trapped carriers do not contribute to the photocurrent but continue to contribute to the field through the Poisson equation. The instantaneous photocurrent iph(t) is calculated from the drift of the free carriers through the Shockley–Ramo theorem. iph(t) is integrated over the duration of the photocurrent to calculate the total collected charge and hence the collection efficiency ηr. ηr has been calculated as a function of the charge injection ratio r, the electron and hole ranges (drift mobility and lifetime products, μτ), mean photoinjection depth δ, and drift mobility ratio b. The deviation of the collection efficiency ηr from the uniform field case η0 can be as much as 30% smaller than the small signal model prediction. However, for a wide range of electron and hole schubwegs and photoinjection ratios, typical errors remained less than 10% at full injection, the worst case. The present study provides partial justification to the wide-spread use of the uniform-field collection efficiency η0 formula in various applications, even under high injection conditions.</description><subject>Applied physics</subject><subject>Charge efficiency</subject><subject>Charge injection</subject><subject>Collection</subject><subject>Computer simulation</subject><subject>Detectors</subject><subject>Drift</subject><subject>Efficiency</subject><subject>Electric fields</subject><subject>Electrons</subject><subject>Formulations</subject><subject>Photoelectric effect</subject><subject>Photoelectric emission</subject><subject>Poisson equation</subject><issn>0021-8979</issn><issn>1089-7550</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNp90M1LwzAYBvAgCs7pwf8g4Emh803TJulRhl8geFGvIc3H1tE1NWkH--_N3NCD4Ok9vD8eHh6ELgnMCDB6S2YlVKwCOEITAqLKeFnCMZoA5CQTFa9O0VmMKwBCBK0m6GO-VGFhsfZta_XQ-A5b5xrd2E5vcdPhfukHr31nxvTdWGzskJwPEY-dsQHHtWpbPHjcfufEZtGpNp6jE5eOvTjcKXp_uH-bP2Uvr4_P87uXTNOcD5mwBbVOOUq5htRHsNS9VqqoqeNOl6rQnIlakJI6YyrncpNrRlTNiKgLJegUXe1z--A_RxsHufJj2DWQeV4IDiWULKnrvdLBxxisk31o1ipsJQG5m00SeZgt2Zu9jboZ1G6QH7zx4RfK3rj_8N_kL2QrfI0</recordid><startdate>20190628</startdate><enddate>20190628</enddate><creator>Ramaswami, Kieran</creator><creator>Johanson, Robert</creator><creator>Kasap, Safa</creator><general>American Institute of Physics</general><scope>AAYXX</scope><scope>CITATION</scope><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope><orcidid>https://orcid.org/0000-0001-5761-8352</orcidid><orcidid>https://orcid.org/0000-0002-2392-3954</orcidid></search><sort><creationdate>20190628</creationdate><title>Charge collection efficiency in photoconductive detectors under small to large signals</title><author>Ramaswami, Kieran ; Johanson, Robert ; Kasap, Safa</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c327t-8e43efaf337c083986969baa4b3f7fc5a4c768b8153fdd9ff2d2c61ab618b4a83</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Applied physics</topic><topic>Charge efficiency</topic><topic>Charge injection</topic><topic>Collection</topic><topic>Computer simulation</topic><topic>Detectors</topic><topic>Drift</topic><topic>Efficiency</topic><topic>Electric fields</topic><topic>Electrons</topic><topic>Formulations</topic><topic>Photoelectric effect</topic><topic>Photoelectric emission</topic><topic>Poisson equation</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ramaswami, Kieran</creatorcontrib><creatorcontrib>Johanson, Robert</creatorcontrib><creatorcontrib>Kasap, Safa</creatorcontrib><collection>CrossRef</collection><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Journal of applied physics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ramaswami, Kieran</au><au>Johanson, Robert</au><au>Kasap, Safa</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Charge collection efficiency in photoconductive detectors under small to large signals</atitle><jtitle>Journal of applied physics</jtitle><date>2019-06-28</date><risdate>2019</risdate><volume>125</volume><issue>24</issue><issn>0021-8979</issn><eissn>1089-7550</eissn><coden>JAPIAU</coden><abstract>Hecht collection efficiency η0 and its formulations for exponential absorption have been widely used in modeling charge collection efficiency in photoconductive detectors. The basic assumption of the Hecht formulation is that the electric field in the device is uniform, i.e., the photoinjected carriers do not perturb the field. Here, we have used Monte Carlo simulations to model the initial injection of electron and hole pairs and their subsequent transport and trapping in the presence of an electric field, which is calculated from the Poisson equation. Each injected carrier is tracked as it moves in the semiconductor until it is either trapped or reaches the collection electrode. Trapped carriers do not contribute to the photocurrent but continue to contribute to the field through the Poisson equation. The instantaneous photocurrent iph(t) is calculated from the drift of the free carriers through the Shockley–Ramo theorem. iph(t) is integrated over the duration of the photocurrent to calculate the total collected charge and hence the collection efficiency ηr. ηr has been calculated as a function of the charge injection ratio r, the electron and hole ranges (drift mobility and lifetime products, μτ), mean photoinjection depth δ, and drift mobility ratio b. The deviation of the collection efficiency ηr from the uniform field case η0 can be as much as 30% smaller than the small signal model prediction. However, for a wide range of electron and hole schubwegs and photoinjection ratios, typical errors remained less than 10% at full injection, the worst case. The present study provides partial justification to the wide-spread use of the uniform-field collection efficiency η0 formula in various applications, even under high injection conditions.</abstract><cop>Melville</cop><pub>American Institute of Physics</pub><doi>10.1063/1.5096900</doi><tpages>11</tpages><orcidid>https://orcid.org/0000-0001-5761-8352</orcidid><orcidid>https://orcid.org/0000-0002-2392-3954</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0021-8979 |
ispartof | Journal of applied physics, 2019-06, Vol.125 (24) |
issn | 0021-8979 1089-7550 |
language | eng |
recordid | cdi_proquest_journals_2248705056 |
source | AIP Journals Complete; Alma/SFX Local Collection |
subjects | Applied physics Charge efficiency Charge injection Collection Computer simulation Detectors Drift Efficiency Electric fields Electrons Formulations Photoelectric effect Photoelectric emission Poisson equation |
title | Charge collection efficiency in photoconductive detectors under small to large signals |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T22%3A19%3A17IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Charge%20collection%20efficiency%20in%20photoconductive%20detectors%20under%20small%20to%20large%20signals&rft.jtitle=Journal%20of%20applied%20physics&rft.au=Ramaswami,%20Kieran&rft.date=2019-06-28&rft.volume=125&rft.issue=24&rft.issn=0021-8979&rft.eissn=1089-7550&rft.coden=JAPIAU&rft_id=info:doi/10.1063/1.5096900&rft_dat=%3Cproquest_cross%3E2248705056%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2248705056&rft_id=info:pmid/&rfr_iscdi=true |