Optimization of COD removal from leachate nanofiltration concentrate using H2O2/Fe+2/heat – Activated persulfate oxidation processes

This study aimed to remove COD from leachate nanofiltration concentrate (LNFC) by oxidation of H2O2/Fe2+/Heat - activated persulfate (PS) and optimization and modelling of its removal using a Central Composite Design (CCD) by the Response Surface Methodology (RSM). In the results of ANOVA where the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Process safety and environmental protection 2019-06, Vol.126, p.7-17
1. Verfasser: Yazici Guvenc, Senem
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 17
container_issue
container_start_page 7
container_title Process safety and environmental protection
container_volume 126
creator Yazici Guvenc, Senem
description This study aimed to remove COD from leachate nanofiltration concentrate (LNFC) by oxidation of H2O2/Fe2+/Heat - activated persulfate (PS) and optimization and modelling of its removal using a Central Composite Design (CCD) by the Response Surface Methodology (RSM). In the results of ANOVA where the experimental data of the study were analyzed, high correlation coefficients (R2 > 0.80) were obtained from all three processes, and it was seen that models could be explained by these data. The COD removal efficiencies under the optimum conditions for the H2O2, Fe2+ and Heat - activated PS processes were 56.9%, 76.2% and 93.5%, respectively. About 64.3%, 78% and 93.2% removal efficiency values of inert COD were obtained after the H2O2-activated PS, Fe2+-activated PS and Heat-activated PS processes, respectively. Consequently, the heat-activated PS process may be an alternative technology for COD and inert COD removal from leachate nanofiltration concentrate.
doi_str_mv 10.1016/j.psep.2019.03.034
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2246258399</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0957582018313892</els_id><sourcerecordid>2246258399</sourcerecordid><originalsourceid>FETCH-LOGICAL-c295t-98220c6e37c2a0ca4e76c4e6cfcb07f5f30359e96c2b8e7aa4a1f3b6bef816623</originalsourceid><addsrcrecordid>eNp9kMFKAzEQhoMoWKsv4CngUXabZHezu-ClVGsFoRc9hzSd2JTtZk3Sop48-QK-oU9ilvUsDAwD3__PzI_QJSUpJZRPtmnnoUsZoXVKslj5ERrRMs-TrKirYzQidVEmRcXIKTrzfksIoaykI_S17ILZmQ8ZjG2x1Xi2vMUOdvYgG6yd3eEGpNrIALiVrdWmCW5glW0VtP0EeO9N-4IXbMkmc7hmkw3IgH8-v_FUBXOIxBp34Py-0T1t38x68OicVeA9-HN0omXj4eKvj9Hz_O5ptkgel_cPs-ljolhdhKSuGCOKQ1YqJomSOZRc5cCVVitS6kJnJP4LNVdsVUEpZS6pzlZ8BbqinLNsjK4G37j5dQ8-iK3duzauFIzlnBVVVteRYgOlnPXegRadMzvp3gUlos9bbEWft-jzFiSLlUfRzSCCeP_BgBNeGYgZrY0DFcTamv_kv3D7jJI</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2246258399</pqid></control><display><type>article</type><title>Optimization of COD removal from leachate nanofiltration concentrate using H2O2/Fe+2/heat – Activated persulfate oxidation processes</title><source>Elsevier ScienceDirect Journals Complete</source><creator>Yazici Guvenc, Senem</creator><creatorcontrib>Yazici Guvenc, Senem</creatorcontrib><description>This study aimed to remove COD from leachate nanofiltration concentrate (LNFC) by oxidation of H2O2/Fe2+/Heat - activated persulfate (PS) and optimization and modelling of its removal using a Central Composite Design (CCD) by the Response Surface Methodology (RSM). In the results of ANOVA where the experimental data of the study were analyzed, high correlation coefficients (R2 &gt; 0.80) were obtained from all three processes, and it was seen that models could be explained by these data. The COD removal efficiencies under the optimum conditions for the H2O2, Fe2+ and Heat - activated PS processes were 56.9%, 76.2% and 93.5%, respectively. About 64.3%, 78% and 93.2% removal efficiency values of inert COD were obtained after the H2O2-activated PS, Fe2+-activated PS and Heat-activated PS processes, respectively. Consequently, the heat-activated PS process may be an alternative technology for COD and inert COD removal from leachate nanofiltration concentrate.</description><identifier>ISSN: 0957-5820</identifier><identifier>EISSN: 1744-3598</identifier><identifier>DOI: 10.1016/j.psep.2019.03.034</identifier><language>eng</language><publisher>Rugby: Elsevier B.V</publisher><subject>Alternative technology ; Chemical oxygen demand ; COD fractions ; Correlation analysis ; Correlation coefficients ; Filtration ; Heat ; Hydrogen peroxide ; Iron ; Leachate nanofiltration concentrate ; Leachates ; Nanofiltration ; Nanotechnology ; Optimization ; Oxidation ; Persulfate oxidation ; Response surface methodology ; Variance analysis</subject><ispartof>Process safety and environmental protection, 2019-06, Vol.126, p.7-17</ispartof><rights>2019 Institution of Chemical Engineers</rights><rights>Copyright Elsevier Science Ltd. Jun 2019</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c295t-98220c6e37c2a0ca4e76c4e6cfcb07f5f30359e96c2b8e7aa4a1f3b6bef816623</citedby><cites>FETCH-LOGICAL-c295t-98220c6e37c2a0ca4e76c4e6cfcb07f5f30359e96c2b8e7aa4a1f3b6bef816623</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.psep.2019.03.034$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids></links><search><creatorcontrib>Yazici Guvenc, Senem</creatorcontrib><title>Optimization of COD removal from leachate nanofiltration concentrate using H2O2/Fe+2/heat – Activated persulfate oxidation processes</title><title>Process safety and environmental protection</title><description>This study aimed to remove COD from leachate nanofiltration concentrate (LNFC) by oxidation of H2O2/Fe2+/Heat - activated persulfate (PS) and optimization and modelling of its removal using a Central Composite Design (CCD) by the Response Surface Methodology (RSM). In the results of ANOVA where the experimental data of the study were analyzed, high correlation coefficients (R2 &gt; 0.80) were obtained from all three processes, and it was seen that models could be explained by these data. The COD removal efficiencies under the optimum conditions for the H2O2, Fe2+ and Heat - activated PS processes were 56.9%, 76.2% and 93.5%, respectively. About 64.3%, 78% and 93.2% removal efficiency values of inert COD were obtained after the H2O2-activated PS, Fe2+-activated PS and Heat-activated PS processes, respectively. Consequently, the heat-activated PS process may be an alternative technology for COD and inert COD removal from leachate nanofiltration concentrate.</description><subject>Alternative technology</subject><subject>Chemical oxygen demand</subject><subject>COD fractions</subject><subject>Correlation analysis</subject><subject>Correlation coefficients</subject><subject>Filtration</subject><subject>Heat</subject><subject>Hydrogen peroxide</subject><subject>Iron</subject><subject>Leachate nanofiltration concentrate</subject><subject>Leachates</subject><subject>Nanofiltration</subject><subject>Nanotechnology</subject><subject>Optimization</subject><subject>Oxidation</subject><subject>Persulfate oxidation</subject><subject>Response surface methodology</subject><subject>Variance analysis</subject><issn>0957-5820</issn><issn>1744-3598</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNp9kMFKAzEQhoMoWKsv4CngUXabZHezu-ClVGsFoRc9hzSd2JTtZk3Sop48-QK-oU9ilvUsDAwD3__PzI_QJSUpJZRPtmnnoUsZoXVKslj5ERrRMs-TrKirYzQidVEmRcXIKTrzfksIoaykI_S17ILZmQ8ZjG2x1Xi2vMUOdvYgG6yd3eEGpNrIALiVrdWmCW5glW0VtP0EeO9N-4IXbMkmc7hmkw3IgH8-v_FUBXOIxBp34Py-0T1t38x68OicVeA9-HN0omXj4eKvj9Hz_O5ptkgel_cPs-ljolhdhKSuGCOKQ1YqJomSOZRc5cCVVitS6kJnJP4LNVdsVUEpZS6pzlZ8BbqinLNsjK4G37j5dQ8-iK3duzauFIzlnBVVVteRYgOlnPXegRadMzvp3gUlos9bbEWft-jzFiSLlUfRzSCCeP_BgBNeGYgZrY0DFcTamv_kv3D7jJI</recordid><startdate>20190601</startdate><enddate>20190601</enddate><creator>Yazici Guvenc, Senem</creator><general>Elsevier B.V</general><general>Elsevier Science Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7ST</scope><scope>7TB</scope><scope>7U7</scope><scope>8FD</scope><scope>C1K</scope><scope>FR3</scope><scope>KR7</scope><scope>SOI</scope></search><sort><creationdate>20190601</creationdate><title>Optimization of COD removal from leachate nanofiltration concentrate using H2O2/Fe+2/heat – Activated persulfate oxidation processes</title><author>Yazici Guvenc, Senem</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c295t-98220c6e37c2a0ca4e76c4e6cfcb07f5f30359e96c2b8e7aa4a1f3b6bef816623</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Alternative technology</topic><topic>Chemical oxygen demand</topic><topic>COD fractions</topic><topic>Correlation analysis</topic><topic>Correlation coefficients</topic><topic>Filtration</topic><topic>Heat</topic><topic>Hydrogen peroxide</topic><topic>Iron</topic><topic>Leachate nanofiltration concentrate</topic><topic>Leachates</topic><topic>Nanofiltration</topic><topic>Nanotechnology</topic><topic>Optimization</topic><topic>Oxidation</topic><topic>Persulfate oxidation</topic><topic>Response surface methodology</topic><topic>Variance analysis</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Yazici Guvenc, Senem</creatorcontrib><collection>CrossRef</collection><collection>Environment Abstracts</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Toxicology Abstracts</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Engineering Research Database</collection><collection>Civil Engineering Abstracts</collection><collection>Environment Abstracts</collection><jtitle>Process safety and environmental protection</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Yazici Guvenc, Senem</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Optimization of COD removal from leachate nanofiltration concentrate using H2O2/Fe+2/heat – Activated persulfate oxidation processes</atitle><jtitle>Process safety and environmental protection</jtitle><date>2019-06-01</date><risdate>2019</risdate><volume>126</volume><spage>7</spage><epage>17</epage><pages>7-17</pages><issn>0957-5820</issn><eissn>1744-3598</eissn><abstract>This study aimed to remove COD from leachate nanofiltration concentrate (LNFC) by oxidation of H2O2/Fe2+/Heat - activated persulfate (PS) and optimization and modelling of its removal using a Central Composite Design (CCD) by the Response Surface Methodology (RSM). In the results of ANOVA where the experimental data of the study were analyzed, high correlation coefficients (R2 &gt; 0.80) were obtained from all three processes, and it was seen that models could be explained by these data. The COD removal efficiencies under the optimum conditions for the H2O2, Fe2+ and Heat - activated PS processes were 56.9%, 76.2% and 93.5%, respectively. About 64.3%, 78% and 93.2% removal efficiency values of inert COD were obtained after the H2O2-activated PS, Fe2+-activated PS and Heat-activated PS processes, respectively. Consequently, the heat-activated PS process may be an alternative technology for COD and inert COD removal from leachate nanofiltration concentrate.</abstract><cop>Rugby</cop><pub>Elsevier B.V</pub><doi>10.1016/j.psep.2019.03.034</doi><tpages>11</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0957-5820
ispartof Process safety and environmental protection, 2019-06, Vol.126, p.7-17
issn 0957-5820
1744-3598
language eng
recordid cdi_proquest_journals_2246258399
source Elsevier ScienceDirect Journals Complete
subjects Alternative technology
Chemical oxygen demand
COD fractions
Correlation analysis
Correlation coefficients
Filtration
Heat
Hydrogen peroxide
Iron
Leachate nanofiltration concentrate
Leachates
Nanofiltration
Nanotechnology
Optimization
Oxidation
Persulfate oxidation
Response surface methodology
Variance analysis
title Optimization of COD removal from leachate nanofiltration concentrate using H2O2/Fe+2/heat – Activated persulfate oxidation processes
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T16%3A46%3A44IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Optimization%20of%20COD%20removal%20from%20leachate%20nanofiltration%20concentrate%20using%20H2O2/Fe+2/heat%20%E2%80%93%20Activated%20persulfate%20oxidation%20processes&rft.jtitle=Process%20safety%20and%20environmental%20protection&rft.au=Yazici%20Guvenc,%20Senem&rft.date=2019-06-01&rft.volume=126&rft.spage=7&rft.epage=17&rft.pages=7-17&rft.issn=0957-5820&rft.eissn=1744-3598&rft_id=info:doi/10.1016/j.psep.2019.03.034&rft_dat=%3Cproquest_cross%3E2246258399%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2246258399&rft_id=info:pmid/&rft_els_id=S0957582018313892&rfr_iscdi=true