Flow Behavior of Liquid Droplet in Packed Bed

In most previous works, liquid hold-ups were studied by using a fixed bed soaked prior to experiments. In the present study, the characteristics of liquid hold-ups and liquid flow were investigated with initially unsoaked bed. Contact angles (θ) for these particle/liquid (tap water) systems were abo...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:JAPANESE JOURNAL OF MULTIPHASE FLOW 2016/06/15, Vol.30(2), pp.158-165
Hauptverfasser: KAWABATA, Hirotoshi, ONO, Hideki, KONISHI, Hirokazu, TAKEUCHI, Eiichi
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 165
container_issue 2
container_start_page 158
container_title JAPANESE JOURNAL OF MULTIPHASE FLOW
container_volume 30
creator KAWABATA, Hirotoshi
ONO, Hideki
KONISHI, Hirokazu
TAKEUCHI, Eiichi
description In most previous works, liquid hold-ups were studied by using a fixed bed soaked prior to experiments. In the present study, the characteristics of liquid hold-ups and liquid flow were investigated with initially unsoaked bed. Contact angles (θ) for these particle/liquid (tap water) systems were about 70° and 10° for fluorine-coated particles and non-coated particles. Under bad wettability condition (θ≒70°), total and static hold-ups for initially unsoaked bed packed with small balls are remarkably smaller than those for initially soaked bed. In initially unsoaked bed, total and static hold-ups under bad wettability condition (θ≒70°) indicate maximum values at about Dp =10 mm and decrease abruptly in proportion to a decrease in particle size, despite an increase in the specific surface area. Under good wettability condition (θ≒10°), total and static hold-ups are smaller than those of bad wettability condition (θ≒70°), because only restricted liquid droplets and/or liquid rivulets are formed within the packed bed for initially unsoaked bed, nevertheless liquid is easy to spread out on the solid surface under good wettability condition.
doi_str_mv 10.3811/jjmf.30.158
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2235676428</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2235676428</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1568-1e44823da8afcc3295096ebfb62311220f8710c14c94937dd134f3d77137510b3</originalsourceid><addsrcrecordid>eNo90E1LAzEQBuAgChbtyT-w4FG2ZpLsJrkIWq0KBT3oOWTzYbNumzbZKv57t7T0NId5Zl54EboCPKEC4LZtl35C8QQqcYJGIASUFZf4FI2wBFYSweg5GuccGoyxrKEGOULlrIu_xYNb6J8QUxF9MQ-bbbDFY4rrzvVFWBXv2nw7OyB7ic687rIbH-YF-pw9fUxfyvnb8-v0fl4aqGpRgmNMEGq10N4YSmQ15LnGNzWhAIRgLzhgA8xIJim3Fijz1HIOlFeAG3qBrvd_1yluti73qo3btBoiFSG0qnnNiBjUzV6ZFHNOzqt1Ckud_hRgtatE7SpRFKuhkkHf7XWbe_3ljlanPpjOHS05HBwXZqGTciv6D4xHZ3U</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2235676428</pqid></control><display><type>article</type><title>Flow Behavior of Liquid Droplet in Packed Bed</title><source>J-STAGE Free</source><source>EZB-FREE-00999 freely available EZB journals</source><creator>KAWABATA, Hirotoshi ; ONO, Hideki ; KONISHI, Hirokazu ; TAKEUCHI, Eiichi</creator><creatorcontrib>KAWABATA, Hirotoshi ; ONO, Hideki ; KONISHI, Hirokazu ; TAKEUCHI, Eiichi</creatorcontrib><description>In most previous works, liquid hold-ups were studied by using a fixed bed soaked prior to experiments. In the present study, the characteristics of liquid hold-ups and liquid flow were investigated with initially unsoaked bed. Contact angles (θ) for these particle/liquid (tap water) systems were about 70° and 10° for fluorine-coated particles and non-coated particles. Under bad wettability condition (θ≒70°), total and static hold-ups for initially unsoaked bed packed with small balls are remarkably smaller than those for initially soaked bed. In initially unsoaked bed, total and static hold-ups under bad wettability condition (θ≒70°) indicate maximum values at about Dp =10 mm and decrease abruptly in proportion to a decrease in particle size, despite an increase in the specific surface area. Under good wettability condition (θ≒10°), total and static hold-ups are smaller than those of bad wettability condition (θ≒70°), because only restricted liquid droplets and/or liquid rivulets are formed within the packed bed for initially unsoaked bed, nevertheless liquid is easy to spread out on the solid surface under good wettability condition.</description><identifier>ISSN: 0914-2843</identifier><identifier>EISSN: 1881-5790</identifier><identifier>DOI: 10.3811/jjmf.30.158</identifier><language>eng</language><publisher>Osaka City: THE JAPANESE SOCIETY FOR MULTIPHASE FLOW</publisher><subject>Coated particles ; Contact angle ; Drinking water ; Droplets ; Fixed beds ; Fluid dynamics ; Fluorine ; Initially unsoaked beds ; Liquid droplets ; Liquid flow ; Liquid hold-ups ; Packed beds ; Particle/liquid wettability ; Solid surfaces ; Wettability</subject><ispartof>JAPANESE JOURNAL OF MULTIPHASE FLOW, 2016/06/15, Vol.30(2), pp.158-165</ispartof><rights>2016 by The Japanese Society for Multiphase Flow</rights><rights>Copyright Japan Science and Technology Agency 2016</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c1568-1e44823da8afcc3295096ebfb62311220f8710c14c94937dd134f3d77137510b3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,1877,27901,27902</link.rule.ids></links><search><creatorcontrib>KAWABATA, Hirotoshi</creatorcontrib><creatorcontrib>ONO, Hideki</creatorcontrib><creatorcontrib>KONISHI, Hirokazu</creatorcontrib><creatorcontrib>TAKEUCHI, Eiichi</creatorcontrib><title>Flow Behavior of Liquid Droplet in Packed Bed</title><title>JAPANESE JOURNAL OF MULTIPHASE FLOW</title><description>In most previous works, liquid hold-ups were studied by using a fixed bed soaked prior to experiments. In the present study, the characteristics of liquid hold-ups and liquid flow were investigated with initially unsoaked bed. Contact angles (θ) for these particle/liquid (tap water) systems were about 70° and 10° for fluorine-coated particles and non-coated particles. Under bad wettability condition (θ≒70°), total and static hold-ups for initially unsoaked bed packed with small balls are remarkably smaller than those for initially soaked bed. In initially unsoaked bed, total and static hold-ups under bad wettability condition (θ≒70°) indicate maximum values at about Dp =10 mm and decrease abruptly in proportion to a decrease in particle size, despite an increase in the specific surface area. Under good wettability condition (θ≒10°), total and static hold-ups are smaller than those of bad wettability condition (θ≒70°), because only restricted liquid droplets and/or liquid rivulets are formed within the packed bed for initially unsoaked bed, nevertheless liquid is easy to spread out on the solid surface under good wettability condition.</description><subject>Coated particles</subject><subject>Contact angle</subject><subject>Drinking water</subject><subject>Droplets</subject><subject>Fixed beds</subject><subject>Fluid dynamics</subject><subject>Fluorine</subject><subject>Initially unsoaked beds</subject><subject>Liquid droplets</subject><subject>Liquid flow</subject><subject>Liquid hold-ups</subject><subject>Packed beds</subject><subject>Particle/liquid wettability</subject><subject>Solid surfaces</subject><subject>Wettability</subject><issn>0914-2843</issn><issn>1881-5790</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><recordid>eNo90E1LAzEQBuAgChbtyT-w4FG2ZpLsJrkIWq0KBT3oOWTzYbNumzbZKv57t7T0NId5Zl54EboCPKEC4LZtl35C8QQqcYJGIASUFZf4FI2wBFYSweg5GuccGoyxrKEGOULlrIu_xYNb6J8QUxF9MQ-bbbDFY4rrzvVFWBXv2nw7OyB7ic687rIbH-YF-pw9fUxfyvnb8-v0fl4aqGpRgmNMEGq10N4YSmQ15LnGNzWhAIRgLzhgA8xIJim3Fijz1HIOlFeAG3qBrvd_1yluti73qo3btBoiFSG0qnnNiBjUzV6ZFHNOzqt1Ckud_hRgtatE7SpRFKuhkkHf7XWbe_3ljlanPpjOHS05HBwXZqGTciv6D4xHZ3U</recordid><startdate>20160615</startdate><enddate>20160615</enddate><creator>KAWABATA, Hirotoshi</creator><creator>ONO, Hideki</creator><creator>KONISHI, Hirokazu</creator><creator>TAKEUCHI, Eiichi</creator><general>THE JAPANESE SOCIETY FOR MULTIPHASE FLOW</general><general>Japan Science and Technology Agency</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7TB</scope><scope>8FD</scope><scope>FR3</scope><scope>KR7</scope></search><sort><creationdate>20160615</creationdate><title>Flow Behavior of Liquid Droplet in Packed Bed</title><author>KAWABATA, Hirotoshi ; ONO, Hideki ; KONISHI, Hirokazu ; TAKEUCHI, Eiichi</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1568-1e44823da8afcc3295096ebfb62311220f8710c14c94937dd134f3d77137510b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>Coated particles</topic><topic>Contact angle</topic><topic>Drinking water</topic><topic>Droplets</topic><topic>Fixed beds</topic><topic>Fluid dynamics</topic><topic>Fluorine</topic><topic>Initially unsoaked beds</topic><topic>Liquid droplets</topic><topic>Liquid flow</topic><topic>Liquid hold-ups</topic><topic>Packed beds</topic><topic>Particle/liquid wettability</topic><topic>Solid surfaces</topic><topic>Wettability</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>KAWABATA, Hirotoshi</creatorcontrib><creatorcontrib>ONO, Hideki</creatorcontrib><creatorcontrib>KONISHI, Hirokazu</creatorcontrib><creatorcontrib>TAKEUCHI, Eiichi</creatorcontrib><collection>CrossRef</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Civil Engineering Abstracts</collection><jtitle>JAPANESE JOURNAL OF MULTIPHASE FLOW</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>KAWABATA, Hirotoshi</au><au>ONO, Hideki</au><au>KONISHI, Hirokazu</au><au>TAKEUCHI, Eiichi</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Flow Behavior of Liquid Droplet in Packed Bed</atitle><jtitle>JAPANESE JOURNAL OF MULTIPHASE FLOW</jtitle><date>2016-06-15</date><risdate>2016</risdate><volume>30</volume><issue>2</issue><spage>158</spage><epage>165</epage><pages>158-165</pages><issn>0914-2843</issn><eissn>1881-5790</eissn><abstract>In most previous works, liquid hold-ups were studied by using a fixed bed soaked prior to experiments. In the present study, the characteristics of liquid hold-ups and liquid flow were investigated with initially unsoaked bed. Contact angles (θ) for these particle/liquid (tap water) systems were about 70° and 10° for fluorine-coated particles and non-coated particles. Under bad wettability condition (θ≒70°), total and static hold-ups for initially unsoaked bed packed with small balls are remarkably smaller than those for initially soaked bed. In initially unsoaked bed, total and static hold-ups under bad wettability condition (θ≒70°) indicate maximum values at about Dp =10 mm and decrease abruptly in proportion to a decrease in particle size, despite an increase in the specific surface area. Under good wettability condition (θ≒10°), total and static hold-ups are smaller than those of bad wettability condition (θ≒70°), because only restricted liquid droplets and/or liquid rivulets are formed within the packed bed for initially unsoaked bed, nevertheless liquid is easy to spread out on the solid surface under good wettability condition.</abstract><cop>Osaka City</cop><pub>THE JAPANESE SOCIETY FOR MULTIPHASE FLOW</pub><doi>10.3811/jjmf.30.158</doi><tpages>8</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0914-2843
ispartof JAPANESE JOURNAL OF MULTIPHASE FLOW, 2016/06/15, Vol.30(2), pp.158-165
issn 0914-2843
1881-5790
language eng
recordid cdi_proquest_journals_2235676428
source J-STAGE Free; EZB-FREE-00999 freely available EZB journals
subjects Coated particles
Contact angle
Drinking water
Droplets
Fixed beds
Fluid dynamics
Fluorine
Initially unsoaked beds
Liquid droplets
Liquid flow
Liquid hold-ups
Packed beds
Particle/liquid wettability
Solid surfaces
Wettability
title Flow Behavior of Liquid Droplet in Packed Bed
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-31T18%3A44%3A35IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Flow%20Behavior%20of%20Liquid%20Droplet%20in%20Packed%20Bed&rft.jtitle=JAPANESE%20JOURNAL%20OF%20MULTIPHASE%20FLOW&rft.au=KAWABATA,%20Hirotoshi&rft.date=2016-06-15&rft.volume=30&rft.issue=2&rft.spage=158&rft.epage=165&rft.pages=158-165&rft.issn=0914-2843&rft.eissn=1881-5790&rft_id=info:doi/10.3811/jjmf.30.158&rft_dat=%3Cproquest_cross%3E2235676428%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2235676428&rft_id=info:pmid/&rfr_iscdi=true