Design, Baseline Characteristics and Carotid Intima-Media Thickness Reproducibility in the PARC Study

Background: Intima-media thickness (IMT) is associated with an increased risk of cardiovascular and cerebral ischemic events, but its correlation with the absolute cardiovascular risk is not known in large populations. The Paroi Artérielle et Risque Cardiovasculaire (PARC) Study is an epidemiologica...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Cerebrovascular diseases (Basel, Switzerland) Switzerland), 2005-01, Vol.19 (1), p.57-63
Hauptverfasser: Touboul, P.J., Vicaut, E., Labreuche, J., Belliard, J.P., Cohen, S., Kownator, S., Pithois-Merli, I.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 63
container_issue 1
container_start_page 57
container_title Cerebrovascular diseases (Basel, Switzerland)
container_volume 19
creator Touboul, P.J.
Vicaut, E.
Labreuche, J.
Belliard, J.P.
Cohen, S.
Kownator, S.
Pithois-Merli, I.
description Background: Intima-media thickness (IMT) is associated with an increased risk of cardiovascular and cerebral ischemic events, but its correlation with the absolute cardiovascular risk is not known in large populations. The Paroi Artérielle et Risque Cardiovasculaire (PARC) Study is an epidemiological study designed to correlate conventional assessment of cardiovascular risk with the mean IMT of the common carotid. Methods: In the PARC study, 6,416 subjects were enrolled, including 80.7% subjects with cardiovascular risk factors and 19.3% without. A specific methodology was designed to harmonize the acquisition and processing of data at the 283 centers. Interreader agreement on image quality and IMT measurement of the common carotid artery (CCAIMT) was assessed from a random sample of 10% of the PARC study population. Results: The intraclass correlation coefficient was 0.98 (95% CI 0.966–0.985), and the accuracy was high (standard deviation of the error measurement: 0.0185 mm). Conclusions: The reproducibility of the measurements assessed by means of the intraclass correlation coefficient and the accuracy of the CCAIMT measurement obtained in the PARC Study demonstrate the feasibility of large multicenter studies of IMT measurement.
doi_str_mv 10.1159/000081913
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_221224920</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>773626611</sourcerecordid><originalsourceid>FETCH-LOGICAL-c357t-633b3c72fd0382fd82d8aa71e30bf525b95b0e939b0e41cc76f61fc00932fe803</originalsourceid><addsrcrecordid>eNptkMFL5TAQxoOsqKt72PPCEjwIC1YzyUubHrW6KiiKq-eSJlNftK99Junh_fcbfU8FcQ4zA_Obj5mPkJ_ADgBkechSKChBrJEtmHDIykLl31LPQKa-YJvkewiPicpBwQbZBCm5UirfIniCwT30-_RYB-xcj7Saaq9NRO9CdCZQ3VtaaT9EZ-lFH91MZ1donaZ3U2eeegyB3uLcD3Y0rnGdiwvqehqnSG-Obiv6L452sUPWW90F_LGq2-T-7-lddZ5dXp9dVEeXmRGyiFkuRCNMwVvLhEpZcau0LgAFa1rJZVPKhmEpypQnYEyRtzm0hrFS8BYVE9tkb6mb7nkeMcR65oLBrtM9DmOo80JMQOYqgbufwMdh9H26reYcOJ-U_EXtzxIyfgjBY1vPfXrfL2pg9Yvx9bvxif29EhybGdoPcuV0An4tgSftH9C_A2_ru19Oq9OTV6Ce21b8B2LakM0</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>221224920</pqid></control><display><type>article</type><title>Design, Baseline Characteristics and Carotid Intima-Media Thickness Reproducibility in the PARC Study</title><source>MEDLINE</source><source>Karger Journals</source><creator>Touboul, P.J. ; Vicaut, E. ; Labreuche, J. ; Belliard, J.P. ; Cohen, S. ; Kownator, S. ; Pithois-Merli, I.</creator><creatorcontrib>Touboul, P.J. ; Vicaut, E. ; Labreuche, J. ; Belliard, J.P. ; Cohen, S. ; Kownator, S. ; Pithois-Merli, I. ; Paroi Artérielle et Risque Cardiovasculaire Study Investigators</creatorcontrib><description>Background: Intima-media thickness (IMT) is associated with an increased risk of cardiovascular and cerebral ischemic events, but its correlation with the absolute cardiovascular risk is not known in large populations. The Paroi Artérielle et Risque Cardiovasculaire (PARC) Study is an epidemiological study designed to correlate conventional assessment of cardiovascular risk with the mean IMT of the common carotid. Methods: In the PARC study, 6,416 subjects were enrolled, including 80.7% subjects with cardiovascular risk factors and 19.3% without. A specific methodology was designed to harmonize the acquisition and processing of data at the 283 centers. Interreader agreement on image quality and IMT measurement of the common carotid artery (CCAIMT) was assessed from a random sample of 10% of the PARC study population. Results: The intraclass correlation coefficient was 0.98 (95% CI 0.966–0.985), and the accuracy was high (standard deviation of the error measurement: 0.0185 mm). Conclusions: The reproducibility of the measurements assessed by means of the intraclass correlation coefficient and the accuracy of the CCAIMT measurement obtained in the PARC Study demonstrate the feasibility of large multicenter studies of IMT measurement.</description><identifier>ISSN: 1015-9770</identifier><identifier>EISSN: 1421-9786</identifier><identifier>DOI: 10.1159/000081913</identifier><identifier>PMID: 15528886</identifier><language>eng</language><publisher>Basel, Switzerland: S. Karger AG</publisher><subject>Adult ; Aged ; Blood Pressure ; Carotid Arteries - diagnostic imaging ; Carotid Artery Diseases - diagnostic imaging ; Carotid Artery Diseases - epidemiology ; Cholesterol, LDL - blood ; Female ; Humans ; Incidence ; Male ; Middle Aged ; Original Paper ; Predictive Value of Tests ; Reproducibility of Results ; Risk Factors ; Tunica Intima - diagnostic imaging ; Tunica Media - diagnostic imaging ; Ultrasonography - standards</subject><ispartof>Cerebrovascular diseases (Basel, Switzerland), 2005-01, Vol.19 (1), p.57-63</ispartof><rights>2005 S. Karger AG, Basel</rights><rights>Copyright (c) 2005 S. Karger AG, Basel</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c357t-633b3c72fd0382fd82d8aa71e30bf525b95b0e939b0e41cc76f61fc00932fe803</citedby><cites>FETCH-LOGICAL-c357t-633b3c72fd0382fd82d8aa71e30bf525b95b0e939b0e41cc76f61fc00932fe803</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,2429,4024,27923,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/15528886$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Touboul, P.J.</creatorcontrib><creatorcontrib>Vicaut, E.</creatorcontrib><creatorcontrib>Labreuche, J.</creatorcontrib><creatorcontrib>Belliard, J.P.</creatorcontrib><creatorcontrib>Cohen, S.</creatorcontrib><creatorcontrib>Kownator, S.</creatorcontrib><creatorcontrib>Pithois-Merli, I.</creatorcontrib><creatorcontrib>Paroi Artérielle et Risque Cardiovasculaire Study Investigators</creatorcontrib><title>Design, Baseline Characteristics and Carotid Intima-Media Thickness Reproducibility in the PARC Study</title><title>Cerebrovascular diseases (Basel, Switzerland)</title><addtitle>Cerebrovasc Dis</addtitle><description>Background: Intima-media thickness (IMT) is associated with an increased risk of cardiovascular and cerebral ischemic events, but its correlation with the absolute cardiovascular risk is not known in large populations. The Paroi Artérielle et Risque Cardiovasculaire (PARC) Study is an epidemiological study designed to correlate conventional assessment of cardiovascular risk with the mean IMT of the common carotid. Methods: In the PARC study, 6,416 subjects were enrolled, including 80.7% subjects with cardiovascular risk factors and 19.3% without. A specific methodology was designed to harmonize the acquisition and processing of data at the 283 centers. Interreader agreement on image quality and IMT measurement of the common carotid artery (CCAIMT) was assessed from a random sample of 10% of the PARC study population. Results: The intraclass correlation coefficient was 0.98 (95% CI 0.966–0.985), and the accuracy was high (standard deviation of the error measurement: 0.0185 mm). Conclusions: The reproducibility of the measurements assessed by means of the intraclass correlation coefficient and the accuracy of the CCAIMT measurement obtained in the PARC Study demonstrate the feasibility of large multicenter studies of IMT measurement.</description><subject>Adult</subject><subject>Aged</subject><subject>Blood Pressure</subject><subject>Carotid Arteries - diagnostic imaging</subject><subject>Carotid Artery Diseases - diagnostic imaging</subject><subject>Carotid Artery Diseases - epidemiology</subject><subject>Cholesterol, LDL - blood</subject><subject>Female</subject><subject>Humans</subject><subject>Incidence</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Original Paper</subject><subject>Predictive Value of Tests</subject><subject>Reproducibility of Results</subject><subject>Risk Factors</subject><subject>Tunica Intima - diagnostic imaging</subject><subject>Tunica Media - diagnostic imaging</subject><subject>Ultrasonography - standards</subject><issn>1015-9770</issn><issn>1421-9786</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2005</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><recordid>eNptkMFL5TAQxoOsqKt72PPCEjwIC1YzyUubHrW6KiiKq-eSJlNftK99Junh_fcbfU8FcQ4zA_Obj5mPkJ_ADgBkechSKChBrJEtmHDIykLl31LPQKa-YJvkewiPicpBwQbZBCm5UirfIniCwT30-_RYB-xcj7Saaq9NRO9CdCZQ3VtaaT9EZ-lFH91MZ1donaZ3U2eeegyB3uLcD3Y0rnGdiwvqehqnSG-Obiv6L452sUPWW90F_LGq2-T-7-lddZ5dXp9dVEeXmRGyiFkuRCNMwVvLhEpZcau0LgAFa1rJZVPKhmEpypQnYEyRtzm0hrFS8BYVE9tkb6mb7nkeMcR65oLBrtM9DmOo80JMQOYqgbufwMdh9H26reYcOJ-U_EXtzxIyfgjBY1vPfXrfL2pg9Yvx9bvxif29EhybGdoPcuV0An4tgSftH9C_A2_ru19Oq9OTV6Ce21b8B2LakM0</recordid><startdate>200501</startdate><enddate>200501</enddate><creator>Touboul, P.J.</creator><creator>Vicaut, E.</creator><creator>Labreuche, J.</creator><creator>Belliard, J.P.</creator><creator>Cohen, S.</creator><creator>Kownator, S.</creator><creator>Pithois-Merli, I.</creator><general>S. Karger AG</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7TK</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>8AO</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>K9.</scope><scope>M0S</scope><scope>M1P</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>7X8</scope></search><sort><creationdate>200501</creationdate><title>Design, Baseline Characteristics and Carotid Intima-Media Thickness Reproducibility in the PARC Study</title><author>Touboul, P.J. ; Vicaut, E. ; Labreuche, J. ; Belliard, J.P. ; Cohen, S. ; Kownator, S. ; Pithois-Merli, I.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c357t-633b3c72fd0382fd82d8aa71e30bf525b95b0e939b0e41cc76f61fc00932fe803</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2005</creationdate><topic>Adult</topic><topic>Aged</topic><topic>Blood Pressure</topic><topic>Carotid Arteries - diagnostic imaging</topic><topic>Carotid Artery Diseases - diagnostic imaging</topic><topic>Carotid Artery Diseases - epidemiology</topic><topic>Cholesterol, LDL - blood</topic><topic>Female</topic><topic>Humans</topic><topic>Incidence</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Original Paper</topic><topic>Predictive Value of Tests</topic><topic>Reproducibility of Results</topic><topic>Risk Factors</topic><topic>Tunica Intima - diagnostic imaging</topic><topic>Tunica Media - diagnostic imaging</topic><topic>Ultrasonography - standards</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Touboul, P.J.</creatorcontrib><creatorcontrib>Vicaut, E.</creatorcontrib><creatorcontrib>Labreuche, J.</creatorcontrib><creatorcontrib>Belliard, J.P.</creatorcontrib><creatorcontrib>Cohen, S.</creatorcontrib><creatorcontrib>Kownator, S.</creatorcontrib><creatorcontrib>Pithois-Merli, I.</creatorcontrib><creatorcontrib>Paroi Artérielle et Risque Cardiovasculaire Study Investigators</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Neurosciences Abstracts</collection><collection>Health &amp; Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>ProQuest Pharma Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Health &amp; Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>MEDLINE - Academic</collection><jtitle>Cerebrovascular diseases (Basel, Switzerland)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Touboul, P.J.</au><au>Vicaut, E.</au><au>Labreuche, J.</au><au>Belliard, J.P.</au><au>Cohen, S.</au><au>Kownator, S.</au><au>Pithois-Merli, I.</au><aucorp>Paroi Artérielle et Risque Cardiovasculaire Study Investigators</aucorp><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Design, Baseline Characteristics and Carotid Intima-Media Thickness Reproducibility in the PARC Study</atitle><jtitle>Cerebrovascular diseases (Basel, Switzerland)</jtitle><addtitle>Cerebrovasc Dis</addtitle><date>2005-01</date><risdate>2005</risdate><volume>19</volume><issue>1</issue><spage>57</spage><epage>63</epage><pages>57-63</pages><issn>1015-9770</issn><eissn>1421-9786</eissn><abstract>Background: Intima-media thickness (IMT) is associated with an increased risk of cardiovascular and cerebral ischemic events, but its correlation with the absolute cardiovascular risk is not known in large populations. The Paroi Artérielle et Risque Cardiovasculaire (PARC) Study is an epidemiological study designed to correlate conventional assessment of cardiovascular risk with the mean IMT of the common carotid. Methods: In the PARC study, 6,416 subjects were enrolled, including 80.7% subjects with cardiovascular risk factors and 19.3% without. A specific methodology was designed to harmonize the acquisition and processing of data at the 283 centers. Interreader agreement on image quality and IMT measurement of the common carotid artery (CCAIMT) was assessed from a random sample of 10% of the PARC study population. Results: The intraclass correlation coefficient was 0.98 (95% CI 0.966–0.985), and the accuracy was high (standard deviation of the error measurement: 0.0185 mm). Conclusions: The reproducibility of the measurements assessed by means of the intraclass correlation coefficient and the accuracy of the CCAIMT measurement obtained in the PARC Study demonstrate the feasibility of large multicenter studies of IMT measurement.</abstract><cop>Basel, Switzerland</cop><pub>S. Karger AG</pub><pmid>15528886</pmid><doi>10.1159/000081913</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1015-9770
ispartof Cerebrovascular diseases (Basel, Switzerland), 2005-01, Vol.19 (1), p.57-63
issn 1015-9770
1421-9786
language eng
recordid cdi_proquest_journals_221224920
source MEDLINE; Karger Journals
subjects Adult
Aged
Blood Pressure
Carotid Arteries - diagnostic imaging
Carotid Artery Diseases - diagnostic imaging
Carotid Artery Diseases - epidemiology
Cholesterol, LDL - blood
Female
Humans
Incidence
Male
Middle Aged
Original Paper
Predictive Value of Tests
Reproducibility of Results
Risk Factors
Tunica Intima - diagnostic imaging
Tunica Media - diagnostic imaging
Ultrasonography - standards
title Design, Baseline Characteristics and Carotid Intima-Media Thickness Reproducibility in the PARC Study
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-21T04%3A17%3A05IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Design,%20Baseline%20Characteristics%20and%20Carotid%20Intima-Media%20Thickness%20Reproducibility%20in%20the%20PARC%20Study&rft.jtitle=Cerebrovascular%20diseases%20(Basel,%20Switzerland)&rft.au=Touboul,%20P.J.&rft.aucorp=Paroi%20Art%C3%A9rielle%20et%20Risque%20Cardiovasculaire%20Study%20Investigators&rft.date=2005-01&rft.volume=19&rft.issue=1&rft.spage=57&rft.epage=63&rft.pages=57-63&rft.issn=1015-9770&rft.eissn=1421-9786&rft_id=info:doi/10.1159/000081913&rft_dat=%3Cproquest_cross%3E773626611%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=221224920&rft_id=info:pmid/15528886&rfr_iscdi=true