Microscale Enzymatic Optical Biosensors Using Mass Transport Limiting Nanofilms. 2. Response Modulation by Varying Analyte Transport Properties
Microscale implantable fluorescent sensors that can be transdermally interrogated using light are being pursued as a minimally invasive biochemical monitoring technology for in vivo applications. Previously, we reported the development of an enzymatic-based sensing platform characterized using gluco...
Gespeichert in:
Veröffentlicht in: | Analytical chemistry (Washington) 2008-03, Vol.80 (5), p.1408-1417 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 1417 |
---|---|
container_issue | 5 |
container_start_page | 1408 |
container_title | Analytical chemistry (Washington) |
container_volume | 80 |
creator | Stein, Erich W Singh, Saurabh McShane, Michael J |
description | Microscale implantable fluorescent sensors that can be transdermally interrogated using light are being pursued as a minimally invasive biochemical monitoring technology for in vivo applications. Previously, we reported the development of an enzymatic-based sensing platform characterized using glucose as a model biochemical analyte for minimally invasive diabetic monitoring. In this work, surface-adsorbed polyelectrolyte nanofilms were employed to modulate the relative fluxes of glucose and oxygen into the sensor, allowing response characteristics, namely, analytical range and sensitivity, to be tuned. Modulation of substrate transport properties were obtained by varying surface-adsorbed nanofilm thicknesses, ionic strength of assembly conditions, and outermost constituents. In general, increasing film thickness through additional cycles of adsorption resulted in consistently decreased glucose flux, correspondingly decreasing sensitivity and increasing range. While the two components of the nanofilms remained the same [poly(allylamine hydrochloride), PAH; poly(sodium 4-styrenesulfonate)}, the assembly conditions and terminal layer were found to strongly influence sensor behavior. Specifically, without added salt in assembly conditions, glucose diffusion was significantly decreased when films were capped with PAH, resulting in reduced sensitivity and extended range of response. With added salt, however, sensor response was the same for films of the same thickness but different terminal materials. These findings demonstrate that sensor response may be customized to cover the hypo- (0−80 mg/dL), normo- (80−120 mg/dL), and hyperglycemic levels (>120 mg/dL) from a single batch of particles through appropriate selection of coating structure and assembly conditions. Furthermore, the results indicate nanofilms of only 12-nm thickness could significantly affect response behavior, confirming predicted behavior by models of sensor reaction−diffusion kinetics. These findings demonstrate the ability to engineer sensor response properties using a simple, cost-effective means and lay the groundwork for developing additional highly sensitive biochemical monitors. |
doi_str_mv | 10.1021/ac701738e |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_217912559</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1438946411</sourcerecordid><originalsourceid>FETCH-LOGICAL-a323t-50cd2afa949a8538fc95735bdef2983ceafe4bfc691dc94c8b2794e109b926363</originalsourceid><addsrcrecordid>eNplkF1rFDEUhoModlu98A9IELzwYtZ87EySy7a0Kuy2pW7Fu5DJJJI6MxlzZsHtn_Avm2GXXcGbHMh5eDjvi9AbSuaUMPrRWEGo4NI9QzNaMlJUUrLnaEYI4QUThJygU4BHQigltHqJTqhkXNCSz9CfVbApgjWtw1f907YzY7D4dsivafFFiOB6iAnwA4T-B14ZALxOpochphEvQxfG6f_G9NGHtoM5ZnN87_K6B4dXsdm02Rh7XG_xN5O2E3zem3Y7un88dykOLo3BwSv0wpsW3Ov9PEMP11fry8_F8vbTl8vzZWE442NREtsw441aKCNLLr1VpeBl3TjPlOTWGe8WtbeVoo1VCytrJtTCUaJqxSpe8TP0bucdUvy1cTDqx7hJ-TDQjApFWVmqDH3YQVNFkJzXQwpdTqEp0VPz-tB8Zt_uhZu6c82R3Fedgfd7wEx1-xzeBjhwLHsqKmjmih0XYHS_D3uTfupKcFHq9d1XzW6WVF6z7_r-6DUWjiH-P_AvqzaoRA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>217912559</pqid></control><display><type>article</type><title>Microscale Enzymatic Optical Biosensors Using Mass Transport Limiting Nanofilms. 2. Response Modulation by Varying Analyte Transport Properties</title><source>MEDLINE</source><source>American Chemical Society Journals</source><creator>Stein, Erich W ; Singh, Saurabh ; McShane, Michael J</creator><creatorcontrib>Stein, Erich W ; Singh, Saurabh ; McShane, Michael J</creatorcontrib><description>Microscale implantable fluorescent sensors that can be transdermally interrogated using light are being pursued as a minimally invasive biochemical monitoring technology for in vivo applications. Previously, we reported the development of an enzymatic-based sensing platform characterized using glucose as a model biochemical analyte for minimally invasive diabetic monitoring. In this work, surface-adsorbed polyelectrolyte nanofilms were employed to modulate the relative fluxes of glucose and oxygen into the sensor, allowing response characteristics, namely, analytical range and sensitivity, to be tuned. Modulation of substrate transport properties were obtained by varying surface-adsorbed nanofilm thicknesses, ionic strength of assembly conditions, and outermost constituents. In general, increasing film thickness through additional cycles of adsorption resulted in consistently decreased glucose flux, correspondingly decreasing sensitivity and increasing range. While the two components of the nanofilms remained the same [poly(allylamine hydrochloride), PAH; poly(sodium 4-styrenesulfonate)}, the assembly conditions and terminal layer were found to strongly influence sensor behavior. Specifically, without added salt in assembly conditions, glucose diffusion was significantly decreased when films were capped with PAH, resulting in reduced sensitivity and extended range of response. With added salt, however, sensor response was the same for films of the same thickness but different terminal materials. These findings demonstrate that sensor response may be customized to cover the hypo- (0−80 mg/dL), normo- (80−120 mg/dL), and hyperglycemic levels (>120 mg/dL) from a single batch of particles through appropriate selection of coating structure and assembly conditions. Furthermore, the results indicate nanofilms of only 12-nm thickness could significantly affect response behavior, confirming predicted behavior by models of sensor reaction−diffusion kinetics. These findings demonstrate the ability to engineer sensor response properties using a simple, cost-effective means and lay the groundwork for developing additional highly sensitive biochemical monitors.</description><identifier>ISSN: 0003-2700</identifier><identifier>EISSN: 1520-6882</identifier><identifier>DOI: 10.1021/ac701738e</identifier><identifier>PMID: 18237153</identifier><identifier>CODEN: ANCHAM</identifier><language>eng</language><publisher>Washington, DC: American Chemical Society</publisher><subject>Analytical chemistry ; Biological and medical sciences ; Biosensing Techniques - instrumentation ; Biosensing Techniques - methods ; Biosensors ; Biotechnology ; Electrolytes ; Fundamental and applied biological sciences. Psychology ; Glucose ; Glucose - chemistry ; Membranes, Artificial ; Methods. Procedures. Technologies ; Nanoparticles ; Nanostructures - chemistry ; Nanostructures - ultrastructure ; Optics and Photonics ; Oxidation-Reduction ; Oxygen - chemistry ; Reaction kinetics ; Sensitivity and Specificity ; Surface Properties ; Various methods and equipments</subject><ispartof>Analytical chemistry (Washington), 2008-03, Vol.80 (5), p.1408-1417</ispartof><rights>Copyright © 2008 American Chemical Society</rights><rights>2008 INIST-CNRS</rights><rights>Copyright American Chemical Society Mar 1, 2008</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a323t-50cd2afa949a8538fc95735bdef2983ceafe4bfc691dc94c8b2794e109b926363</citedby><cites>FETCH-LOGICAL-a323t-50cd2afa949a8538fc95735bdef2983ceafe4bfc691dc94c8b2794e109b926363</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://pubs.acs.org/doi/pdf/10.1021/ac701738e$$EPDF$$P50$$Gacs$$H</linktopdf><linktohtml>$$Uhttps://pubs.acs.org/doi/10.1021/ac701738e$$EHTML$$P50$$Gacs$$H</linktohtml><link.rule.ids>314,776,780,2752,27053,27901,27902,56713,56763</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=20176171$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/18237153$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Stein, Erich W</creatorcontrib><creatorcontrib>Singh, Saurabh</creatorcontrib><creatorcontrib>McShane, Michael J</creatorcontrib><title>Microscale Enzymatic Optical Biosensors Using Mass Transport Limiting Nanofilms. 2. Response Modulation by Varying Analyte Transport Properties</title><title>Analytical chemistry (Washington)</title><addtitle>Anal. Chem</addtitle><description>Microscale implantable fluorescent sensors that can be transdermally interrogated using light are being pursued as a minimally invasive biochemical monitoring technology for in vivo applications. Previously, we reported the development of an enzymatic-based sensing platform characterized using glucose as a model biochemical analyte for minimally invasive diabetic monitoring. In this work, surface-adsorbed polyelectrolyte nanofilms were employed to modulate the relative fluxes of glucose and oxygen into the sensor, allowing response characteristics, namely, analytical range and sensitivity, to be tuned. Modulation of substrate transport properties were obtained by varying surface-adsorbed nanofilm thicknesses, ionic strength of assembly conditions, and outermost constituents. In general, increasing film thickness through additional cycles of adsorption resulted in consistently decreased glucose flux, correspondingly decreasing sensitivity and increasing range. While the two components of the nanofilms remained the same [poly(allylamine hydrochloride), PAH; poly(sodium 4-styrenesulfonate)}, the assembly conditions and terminal layer were found to strongly influence sensor behavior. Specifically, without added salt in assembly conditions, glucose diffusion was significantly decreased when films were capped with PAH, resulting in reduced sensitivity and extended range of response. With added salt, however, sensor response was the same for films of the same thickness but different terminal materials. These findings demonstrate that sensor response may be customized to cover the hypo- (0−80 mg/dL), normo- (80−120 mg/dL), and hyperglycemic levels (>120 mg/dL) from a single batch of particles through appropriate selection of coating structure and assembly conditions. Furthermore, the results indicate nanofilms of only 12-nm thickness could significantly affect response behavior, confirming predicted behavior by models of sensor reaction−diffusion kinetics. These findings demonstrate the ability to engineer sensor response properties using a simple, cost-effective means and lay the groundwork for developing additional highly sensitive biochemical monitors.</description><subject>Analytical chemistry</subject><subject>Biological and medical sciences</subject><subject>Biosensing Techniques - instrumentation</subject><subject>Biosensing Techniques - methods</subject><subject>Biosensors</subject><subject>Biotechnology</subject><subject>Electrolytes</subject><subject>Fundamental and applied biological sciences. Psychology</subject><subject>Glucose</subject><subject>Glucose - chemistry</subject><subject>Membranes, Artificial</subject><subject>Methods. Procedures. Technologies</subject><subject>Nanoparticles</subject><subject>Nanostructures - chemistry</subject><subject>Nanostructures - ultrastructure</subject><subject>Optics and Photonics</subject><subject>Oxidation-Reduction</subject><subject>Oxygen - chemistry</subject><subject>Reaction kinetics</subject><subject>Sensitivity and Specificity</subject><subject>Surface Properties</subject><subject>Various methods and equipments</subject><issn>0003-2700</issn><issn>1520-6882</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2008</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNplkF1rFDEUhoModlu98A9IELzwYtZ87EySy7a0Kuy2pW7Fu5DJJJI6MxlzZsHtn_Avm2GXXcGbHMh5eDjvi9AbSuaUMPrRWEGo4NI9QzNaMlJUUrLnaEYI4QUThJygU4BHQigltHqJTqhkXNCSz9CfVbApgjWtw1f907YzY7D4dsivafFFiOB6iAnwA4T-B14ZALxOpochphEvQxfG6f_G9NGHtoM5ZnN87_K6B4dXsdm02Rh7XG_xN5O2E3zem3Y7un88dykOLo3BwSv0wpsW3Ov9PEMP11fry8_F8vbTl8vzZWE442NREtsw441aKCNLLr1VpeBl3TjPlOTWGe8WtbeVoo1VCytrJtTCUaJqxSpe8TP0bucdUvy1cTDqx7hJ-TDQjApFWVmqDH3YQVNFkJzXQwpdTqEp0VPz-tB8Zt_uhZu6c82R3Fedgfd7wEx1-xzeBjhwLHsqKmjmih0XYHS_D3uTfupKcFHq9d1XzW6WVF6z7_r-6DUWjiH-P_AvqzaoRA</recordid><startdate>20080301</startdate><enddate>20080301</enddate><creator>Stein, Erich W</creator><creator>Singh, Saurabh</creator><creator>McShane, Michael J</creator><general>American Chemical Society</general><scope>BSCLL</scope><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QF</scope><scope>7QO</scope><scope>7QQ</scope><scope>7SC</scope><scope>7SE</scope><scope>7SP</scope><scope>7SR</scope><scope>7TA</scope><scope>7TB</scope><scope>7TM</scope><scope>7U5</scope><scope>7U7</scope><scope>7U9</scope><scope>8BQ</scope><scope>8FD</scope><scope>C1K</scope><scope>F28</scope><scope>FR3</scope><scope>H8D</scope><scope>H8G</scope><scope>H94</scope><scope>JG9</scope><scope>JQ2</scope><scope>KR7</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope><scope>P64</scope></search><sort><creationdate>20080301</creationdate><title>Microscale Enzymatic Optical Biosensors Using Mass Transport Limiting Nanofilms. 2. Response Modulation by Varying Analyte Transport Properties</title><author>Stein, Erich W ; Singh, Saurabh ; McShane, Michael J</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a323t-50cd2afa949a8538fc95735bdef2983ceafe4bfc691dc94c8b2794e109b926363</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2008</creationdate><topic>Analytical chemistry</topic><topic>Biological and medical sciences</topic><topic>Biosensing Techniques - instrumentation</topic><topic>Biosensing Techniques - methods</topic><topic>Biosensors</topic><topic>Biotechnology</topic><topic>Electrolytes</topic><topic>Fundamental and applied biological sciences. Psychology</topic><topic>Glucose</topic><topic>Glucose - chemistry</topic><topic>Membranes, Artificial</topic><topic>Methods. Procedures. Technologies</topic><topic>Nanoparticles</topic><topic>Nanostructures - chemistry</topic><topic>Nanostructures - ultrastructure</topic><topic>Optics and Photonics</topic><topic>Oxidation-Reduction</topic><topic>Oxygen - chemistry</topic><topic>Reaction kinetics</topic><topic>Sensitivity and Specificity</topic><topic>Surface Properties</topic><topic>Various methods and equipments</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Stein, Erich W</creatorcontrib><creatorcontrib>Singh, Saurabh</creatorcontrib><creatorcontrib>McShane, Michael J</creatorcontrib><collection>Istex</collection><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Aluminium Industry Abstracts</collection><collection>Biotechnology Research Abstracts</collection><collection>Ceramic Abstracts</collection><collection>Computer and Information Systems Abstracts</collection><collection>Corrosion Abstracts</collection><collection>Electronics & Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Materials Business File</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Nucleic Acids Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Toxicology Abstracts</collection><collection>Virology and AIDS Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ANTE: Abstracts in New Technology & Engineering</collection><collection>Engineering Research Database</collection><collection>Aerospace Database</collection><collection>Copper Technical Reference Library</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>Materials Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>Biotechnology and BioEngineering Abstracts</collection><jtitle>Analytical chemistry (Washington)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Stein, Erich W</au><au>Singh, Saurabh</au><au>McShane, Michael J</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Microscale Enzymatic Optical Biosensors Using Mass Transport Limiting Nanofilms. 2. Response Modulation by Varying Analyte Transport Properties</atitle><jtitle>Analytical chemistry (Washington)</jtitle><addtitle>Anal. Chem</addtitle><date>2008-03-01</date><risdate>2008</risdate><volume>80</volume><issue>5</issue><spage>1408</spage><epage>1417</epage><pages>1408-1417</pages><issn>0003-2700</issn><eissn>1520-6882</eissn><coden>ANCHAM</coden><abstract>Microscale implantable fluorescent sensors that can be transdermally interrogated using light are being pursued as a minimally invasive biochemical monitoring technology for in vivo applications. Previously, we reported the development of an enzymatic-based sensing platform characterized using glucose as a model biochemical analyte for minimally invasive diabetic monitoring. In this work, surface-adsorbed polyelectrolyte nanofilms were employed to modulate the relative fluxes of glucose and oxygen into the sensor, allowing response characteristics, namely, analytical range and sensitivity, to be tuned. Modulation of substrate transport properties were obtained by varying surface-adsorbed nanofilm thicknesses, ionic strength of assembly conditions, and outermost constituents. In general, increasing film thickness through additional cycles of adsorption resulted in consistently decreased glucose flux, correspondingly decreasing sensitivity and increasing range. While the two components of the nanofilms remained the same [poly(allylamine hydrochloride), PAH; poly(sodium 4-styrenesulfonate)}, the assembly conditions and terminal layer were found to strongly influence sensor behavior. Specifically, without added salt in assembly conditions, glucose diffusion was significantly decreased when films were capped with PAH, resulting in reduced sensitivity and extended range of response. With added salt, however, sensor response was the same for films of the same thickness but different terminal materials. These findings demonstrate that sensor response may be customized to cover the hypo- (0−80 mg/dL), normo- (80−120 mg/dL), and hyperglycemic levels (>120 mg/dL) from a single batch of particles through appropriate selection of coating structure and assembly conditions. Furthermore, the results indicate nanofilms of only 12-nm thickness could significantly affect response behavior, confirming predicted behavior by models of sensor reaction−diffusion kinetics. These findings demonstrate the ability to engineer sensor response properties using a simple, cost-effective means and lay the groundwork for developing additional highly sensitive biochemical monitors.</abstract><cop>Washington, DC</cop><pub>American Chemical Society</pub><pmid>18237153</pmid><doi>10.1021/ac701738e</doi><tpages>10</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0003-2700 |
ispartof | Analytical chemistry (Washington), 2008-03, Vol.80 (5), p.1408-1417 |
issn | 0003-2700 1520-6882 |
language | eng |
recordid | cdi_proquest_journals_217912559 |
source | MEDLINE; American Chemical Society Journals |
subjects | Analytical chemistry Biological and medical sciences Biosensing Techniques - instrumentation Biosensing Techniques - methods Biosensors Biotechnology Electrolytes Fundamental and applied biological sciences. Psychology Glucose Glucose - chemistry Membranes, Artificial Methods. Procedures. Technologies Nanoparticles Nanostructures - chemistry Nanostructures - ultrastructure Optics and Photonics Oxidation-Reduction Oxygen - chemistry Reaction kinetics Sensitivity and Specificity Surface Properties Various methods and equipments |
title | Microscale Enzymatic Optical Biosensors Using Mass Transport Limiting Nanofilms. 2. Response Modulation by Varying Analyte Transport Properties |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-21T20%3A33%3A14IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Microscale%20Enzymatic%20Optical%20Biosensors%20Using%20Mass%20Transport%20Limiting%20Nanofilms.%202.%20Response%20Modulation%20by%20Varying%20Analyte%20Transport%20Properties&rft.jtitle=Analytical%20chemistry%20(Washington)&rft.au=Stein,%20Erich%20W&rft.date=2008-03-01&rft.volume=80&rft.issue=5&rft.spage=1408&rft.epage=1417&rft.pages=1408-1417&rft.issn=0003-2700&rft.eissn=1520-6882&rft.coden=ANCHAM&rft_id=info:doi/10.1021/ac701738e&rft_dat=%3Cproquest_cross%3E1438946411%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=217912559&rft_id=info:pmid/18237153&rfr_iscdi=true |