Pulsed excitation source multiplexed fluorometry for the simultaneous measurement of multiple analytes. Continuous measurement of atmospheric hydrogen peroxide
Presently, solid-state sources such as light-emitting diodes (LEDs) provide for intense, nearly monochromatic fight They are available over a broad range of emission wavelengths. Unlike incandescent and discharge lamps, LEDs can be turned on and off at high speeds. The resulting light pulses are hig...
Gespeichert in:
Veröffentlicht in: | Analytical chemistry (Washington) 2003-03, Vol.75 (5), p.1203 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | 5 |
container_start_page | 1203 |
container_title | Analytical chemistry (Washington) |
container_volume | 75 |
creator | Li, Jianzhong Dasgupta, Purnendu K Tarver, Gary A |
description | Presently, solid-state sources such as light-emitting diodes (LEDs) provide for intense, nearly monochromatic fight They are available over a broad range of emission wavelengths. Unlike incandescent and discharge lamps, LEDs can be turned on and off at high speeds. The resulting light pulses are highly reproducible. This allows the use of a single photomultiplier tube (PMT) often the most expensive component in a high-sensitivity measurement system, as a multiplexed detector with multiple, fiber-optic-coupled, fluorescence-detection cells excited by solid-state sources. A time resolution of 1 min is adequate in many continuous detection schemes. This enables multiple-channel single-detector multiplexed measurement without any loss of S/N. On the basis of this principle, we describe a new automated continuous instrument for the simultaneous measurement of atmospheric hydrogen peroxide and methyl hydroperoxide (MHP). A Nafion membrane diffusion scrubber (DS) is used with hematin-catalyzed oxidation of thiamine to thiochrome for the measurement of H202, and an expanded poly(tetrafluoroethylene) (ePTFE) DS is used with a H202 destruction catalyst and horseradish peroxidasecatalyzed oxidation of thiamine to thiochrome for the measurement of MHP. The respective limits of detection are 25 pptv and 15 pptv. Design, performance details, and illustrative results from a field campaign (Philadelphia NE03PS study, 2001) are presented. [PUBLICATION ABSTRACT] |
format | Article |
fullrecord | <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_journals_217866569</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>304855191</sourcerecordid><originalsourceid>FETCH-proquest_journals_2178665693</originalsourceid><addsrcrecordid>eNqNjrFOxDAQRC3ESYTj_mFFH2TndL5Qn0CUFPQnK9kQn2xv8K6l5Gv4VYKEqCioppg3mnelKnNodG3btrlWldZ6XzdHrW_ULfNFa2O0sZX6fC2BsQecOy9OPCVgKrlDiCWInwLOazuEQpkiSl5goAwyIrD_JlxCKgwRHZeMEZMADb9bcMmFRZAf4ERJfCp_wE4i8TRi9h2MS5_pHRNMmGn2Pd6pzeBWw91PbtX989Pb6aWeMn0UZDlfVt31hc-NObbWHuzj_l_QFzoDYE4</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>217866569</pqid></control><display><type>article</type><title>Pulsed excitation source multiplexed fluorometry for the simultaneous measurement of multiple analytes. Continuous measurement of atmospheric hydrogen peroxide</title><source>ACS Publications</source><creator>Li, Jianzhong ; Dasgupta, Purnendu K ; Tarver, Gary A</creator><creatorcontrib>Li, Jianzhong ; Dasgupta, Purnendu K ; Tarver, Gary A</creatorcontrib><description>Presently, solid-state sources such as light-emitting diodes (LEDs) provide for intense, nearly monochromatic fight They are available over a broad range of emission wavelengths. Unlike incandescent and discharge lamps, LEDs can be turned on and off at high speeds. The resulting light pulses are highly reproducible. This allows the use of a single photomultiplier tube (PMT) often the most expensive component in a high-sensitivity measurement system, as a multiplexed detector with multiple, fiber-optic-coupled, fluorescence-detection cells excited by solid-state sources. A time resolution of 1 min is adequate in many continuous detection schemes. This enables multiple-channel single-detector multiplexed measurement without any loss of S/N. On the basis of this principle, we describe a new automated continuous instrument for the simultaneous measurement of atmospheric hydrogen peroxide and methyl hydroperoxide (MHP). A Nafion membrane diffusion scrubber (DS) is used with hematin-catalyzed oxidation of thiamine to thiochrome for the measurement of H202, and an expanded poly(tetrafluoroethylene) (ePTFE) DS is used with a H202 destruction catalyst and horseradish peroxidasecatalyzed oxidation of thiamine to thiochrome for the measurement of MHP. The respective limits of detection are 25 pptv and 15 pptv. Design, performance details, and illustrative results from a field campaign (Philadelphia NE03PS study, 2001) are presented. [PUBLICATION ABSTRACT]</description><identifier>ISSN: 0003-2700</identifier><identifier>EISSN: 1520-6882</identifier><identifier>CODEN: ANCHAM</identifier><language>eng</language><publisher>Washington: American Chemical Society</publisher><subject>Atmosphere ; Hydrogen ; Measurement</subject><ispartof>Analytical chemistry (Washington), 2003-03, Vol.75 (5), p.1203</ispartof><rights>Copyright American Chemical Society Mar 1, 2003</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780</link.rule.ids></links><search><creatorcontrib>Li, Jianzhong</creatorcontrib><creatorcontrib>Dasgupta, Purnendu K</creatorcontrib><creatorcontrib>Tarver, Gary A</creatorcontrib><title>Pulsed excitation source multiplexed fluorometry for the simultaneous measurement of multiple analytes. Continuous measurement of atmospheric hydrogen peroxide</title><title>Analytical chemistry (Washington)</title><description>Presently, solid-state sources such as light-emitting diodes (LEDs) provide for intense, nearly monochromatic fight They are available over a broad range of emission wavelengths. Unlike incandescent and discharge lamps, LEDs can be turned on and off at high speeds. The resulting light pulses are highly reproducible. This allows the use of a single photomultiplier tube (PMT) often the most expensive component in a high-sensitivity measurement system, as a multiplexed detector with multiple, fiber-optic-coupled, fluorescence-detection cells excited by solid-state sources. A time resolution of 1 min is adequate in many continuous detection schemes. This enables multiple-channel single-detector multiplexed measurement without any loss of S/N. On the basis of this principle, we describe a new automated continuous instrument for the simultaneous measurement of atmospheric hydrogen peroxide and methyl hydroperoxide (MHP). A Nafion membrane diffusion scrubber (DS) is used with hematin-catalyzed oxidation of thiamine to thiochrome for the measurement of H202, and an expanded poly(tetrafluoroethylene) (ePTFE) DS is used with a H202 destruction catalyst and horseradish peroxidasecatalyzed oxidation of thiamine to thiochrome for the measurement of MHP. The respective limits of detection are 25 pptv and 15 pptv. Design, performance details, and illustrative results from a field campaign (Philadelphia NE03PS study, 2001) are presented. [PUBLICATION ABSTRACT]</description><subject>Atmosphere</subject><subject>Hydrogen</subject><subject>Measurement</subject><issn>0003-2700</issn><issn>1520-6882</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2003</creationdate><recordtype>article</recordtype><recordid>eNqNjrFOxDAQRC3ESYTj_mFFH2TndL5Qn0CUFPQnK9kQn2xv8K6l5Gv4VYKEqCioppg3mnelKnNodG3btrlWldZ6XzdHrW_ULfNFa2O0sZX6fC2BsQecOy9OPCVgKrlDiCWInwLOazuEQpkiSl5goAwyIrD_JlxCKgwRHZeMEZMADb9bcMmFRZAf4ERJfCp_wE4i8TRi9h2MS5_pHRNMmGn2Pd6pzeBWw91PbtX989Pb6aWeMn0UZDlfVt31hc-NObbWHuzj_l_QFzoDYE4</recordid><startdate>20030301</startdate><enddate>20030301</enddate><creator>Li, Jianzhong</creator><creator>Dasgupta, Purnendu K</creator><creator>Tarver, Gary A</creator><general>American Chemical Society</general><scope>7QF</scope><scope>7QO</scope><scope>7QQ</scope><scope>7SC</scope><scope>7SE</scope><scope>7SP</scope><scope>7SR</scope><scope>7TA</scope><scope>7TB</scope><scope>7TM</scope><scope>7U5</scope><scope>7U7</scope><scope>7U9</scope><scope>8BQ</scope><scope>8FD</scope><scope>C1K</scope><scope>F28</scope><scope>FR3</scope><scope>H8D</scope><scope>H8G</scope><scope>H94</scope><scope>JG9</scope><scope>JQ2</scope><scope>KR7</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope><scope>P64</scope></search><sort><creationdate>20030301</creationdate><title>Pulsed excitation source multiplexed fluorometry for the simultaneous measurement of multiple analytes. Continuous measurement of atmospheric hydrogen peroxide</title><author>Li, Jianzhong ; Dasgupta, Purnendu K ; Tarver, Gary A</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_journals_2178665693</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2003</creationdate><topic>Atmosphere</topic><topic>Hydrogen</topic><topic>Measurement</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Li, Jianzhong</creatorcontrib><creatorcontrib>Dasgupta, Purnendu K</creatorcontrib><creatorcontrib>Tarver, Gary A</creatorcontrib><collection>Aluminium Industry Abstracts</collection><collection>Biotechnology Research Abstracts</collection><collection>Ceramic Abstracts</collection><collection>Computer and Information Systems Abstracts</collection><collection>Corrosion Abstracts</collection><collection>Electronics & Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Materials Business File</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Nucleic Acids Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Toxicology Abstracts</collection><collection>Virology and AIDS Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ANTE: Abstracts in New Technology & Engineering</collection><collection>Engineering Research Database</collection><collection>Aerospace Database</collection><collection>Copper Technical Reference Library</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>Materials Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>Biotechnology and BioEngineering Abstracts</collection><jtitle>Analytical chemistry (Washington)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Li, Jianzhong</au><au>Dasgupta, Purnendu K</au><au>Tarver, Gary A</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Pulsed excitation source multiplexed fluorometry for the simultaneous measurement of multiple analytes. Continuous measurement of atmospheric hydrogen peroxide</atitle><jtitle>Analytical chemistry (Washington)</jtitle><date>2003-03-01</date><risdate>2003</risdate><volume>75</volume><issue>5</issue><spage>1203</spage><pages>1203-</pages><issn>0003-2700</issn><eissn>1520-6882</eissn><coden>ANCHAM</coden><abstract>Presently, solid-state sources such as light-emitting diodes (LEDs) provide for intense, nearly monochromatic fight They are available over a broad range of emission wavelengths. Unlike incandescent and discharge lamps, LEDs can be turned on and off at high speeds. The resulting light pulses are highly reproducible. This allows the use of a single photomultiplier tube (PMT) often the most expensive component in a high-sensitivity measurement system, as a multiplexed detector with multiple, fiber-optic-coupled, fluorescence-detection cells excited by solid-state sources. A time resolution of 1 min is adequate in many continuous detection schemes. This enables multiple-channel single-detector multiplexed measurement without any loss of S/N. On the basis of this principle, we describe a new automated continuous instrument for the simultaneous measurement of atmospheric hydrogen peroxide and methyl hydroperoxide (MHP). A Nafion membrane diffusion scrubber (DS) is used with hematin-catalyzed oxidation of thiamine to thiochrome for the measurement of H202, and an expanded poly(tetrafluoroethylene) (ePTFE) DS is used with a H202 destruction catalyst and horseradish peroxidasecatalyzed oxidation of thiamine to thiochrome for the measurement of MHP. The respective limits of detection are 25 pptv and 15 pptv. Design, performance details, and illustrative results from a field campaign (Philadelphia NE03PS study, 2001) are presented. [PUBLICATION ABSTRACT]</abstract><cop>Washington</cop><pub>American Chemical Society</pub></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0003-2700 |
ispartof | Analytical chemistry (Washington), 2003-03, Vol.75 (5), p.1203 |
issn | 0003-2700 1520-6882 |
language | eng |
recordid | cdi_proquest_journals_217866569 |
source | ACS Publications |
subjects | Atmosphere Hydrogen Measurement |
title | Pulsed excitation source multiplexed fluorometry for the simultaneous measurement of multiple analytes. Continuous measurement of atmospheric hydrogen peroxide |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-21T05%3A19%3A06IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Pulsed%20excitation%20source%20multiplexed%20fluorometry%20for%20the%20simultaneous%20measurement%20of%20multiple%20analytes.%20Continuous%20measurement%20of%20atmospheric%20hydrogen%20peroxide&rft.jtitle=Analytical%20chemistry%20(Washington)&rft.au=Li,%20Jianzhong&rft.date=2003-03-01&rft.volume=75&rft.issue=5&rft.spage=1203&rft.pages=1203-&rft.issn=0003-2700&rft.eissn=1520-6882&rft.coden=ANCHAM&rft_id=info:doi/&rft_dat=%3Cproquest%3E304855191%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=217866569&rft_id=info:pmid/&rfr_iscdi=true |