Piezoelectric pH sensors: AT-cut quartz resonators with amphoteric polymer films

Piezoelectric AT-cut quartz resonators immersed in aqueous media, coated with cross-linked films of amphoteric polymer 1, exhibit large frequency changes when the pH is changed in the vicinity of the isoelectric point of the polymer film. The unique pH-sensing capabilities of the coated resonators,...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analytical chemistry (Washington) 1993-10, Vol.65 (19), p.2553-2562
Hauptverfasser: Wang, Juan, Ward, Michael D, Ebersole, Richard C, Foss, Robert P
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 2562
container_issue 19
container_start_page 2553
container_title Analytical chemistry (Washington)
container_volume 65
creator Wang, Juan
Ward, Michael D
Ebersole, Richard C
Foss, Robert P
description Piezoelectric AT-cut quartz resonators immersed in aqueous media, coated with cross-linked films of amphoteric polymer 1, exhibit large frequency changes when the pH is changed in the vicinity of the isoelectric point of the polymer film. The unique pH-sensing capabilities of the coated resonators, combined with their robustness, ease of fabrication and low cost, provide a convenient approach for the measurement of threshold pH changes.
doi_str_mv 10.1021/ac00067a002
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_217846157</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>7191560</sourcerecordid><originalsourceid>FETCH-LOGICAL-a357t-e2fc9f9b321841db071ce4b28662458ecbbbd0de5d8c69a2d3016d81992322e3</originalsourceid><addsrcrecordid>eNptkN1LwzAUxYMoOKdP_gNBBB-kmo82aX2bQzdRcGDxNaRpyjr7sSUpuv31ZnZMH3y6cO_vnHs4AJxjdIMRwbdSIYQYlwiRAzDAEUEBi2NyCAZ-TwPCEToGJ9YuEMIYYTYAs1mpN62utHKmVHA5hVY3tjX2Do7SQHUOrjpp3AYabdtGOn-Bn6WbQ1kv563TP6K2WtfawKKsansKjgpZWX22m0OQPj6k42nw8jp5Go9eAkkj7gJNCpUUSUYJjkOcZ4hjpcOMxIyRMIq1yrIsR7mO8lixRJKc-rh5jJOEUEI0HYKL3nZp2lWnrROLtjON_ygI5nHIcMQ9dN1DyrTWGl2IpSlradYCI7EtTPwpzNOXO0tplawKIxtV2r2Ecu_IsMeCHiut01_7szQfgnEPiXT2Jmj0nj7z-4nYhrjqeansb8j_AnwDHN-Fsg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>217846157</pqid></control><display><type>article</type><title>Piezoelectric pH sensors: AT-cut quartz resonators with amphoteric polymer films</title><source>American Chemical Society Journals</source><creator>Wang, Juan ; Ward, Michael D ; Ebersole, Richard C ; Foss, Robert P</creator><creatorcontrib>Wang, Juan ; Ward, Michael D ; Ebersole, Richard C ; Foss, Robert P</creatorcontrib><description>Piezoelectric AT-cut quartz resonators immersed in aqueous media, coated with cross-linked films of amphoteric polymer 1, exhibit large frequency changes when the pH is changed in the vicinity of the isoelectric point of the polymer film. The unique pH-sensing capabilities of the coated resonators, combined with their robustness, ease of fabrication and low cost, provide a convenient approach for the measurement of threshold pH changes.</description><identifier>ISSN: 0003-2700</identifier><identifier>EISSN: 1520-6882</identifier><identifier>DOI: 10.1021/ac00067a002</identifier><identifier>CODEN: ANCHAM</identifier><language>eng</language><publisher>Washington, DC: American Chemical Society</publisher><subject>Analytical chemistry ; Chemistry ; Exact sciences and technology ; General, instrumentation ; Polymers</subject><ispartof>Analytical chemistry (Washington), 1993-10, Vol.65 (19), p.2553-2562</ispartof><rights>1994 INIST-CNRS</rights><rights>Copyright American Chemical Society Oct 1, 1993</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a357t-e2fc9f9b321841db071ce4b28662458ecbbbd0de5d8c69a2d3016d81992322e3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://pubs.acs.org/doi/pdf/10.1021/ac00067a002$$EPDF$$P50$$Gacs$$H</linktopdf><linktohtml>$$Uhttps://pubs.acs.org/doi/10.1021/ac00067a002$$EHTML$$P50$$Gacs$$H</linktohtml><link.rule.ids>314,780,784,2765,27076,27924,27925,56738,56788</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=3757361$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Wang, Juan</creatorcontrib><creatorcontrib>Ward, Michael D</creatorcontrib><creatorcontrib>Ebersole, Richard C</creatorcontrib><creatorcontrib>Foss, Robert P</creatorcontrib><title>Piezoelectric pH sensors: AT-cut quartz resonators with amphoteric polymer films</title><title>Analytical chemistry (Washington)</title><addtitle>Anal. Chem</addtitle><description>Piezoelectric AT-cut quartz resonators immersed in aqueous media, coated with cross-linked films of amphoteric polymer 1, exhibit large frequency changes when the pH is changed in the vicinity of the isoelectric point of the polymer film. The unique pH-sensing capabilities of the coated resonators, combined with their robustness, ease of fabrication and low cost, provide a convenient approach for the measurement of threshold pH changes.</description><subject>Analytical chemistry</subject><subject>Chemistry</subject><subject>Exact sciences and technology</subject><subject>General, instrumentation</subject><subject>Polymers</subject><issn>0003-2700</issn><issn>1520-6882</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1993</creationdate><recordtype>article</recordtype><recordid>eNptkN1LwzAUxYMoOKdP_gNBBB-kmo82aX2bQzdRcGDxNaRpyjr7sSUpuv31ZnZMH3y6cO_vnHs4AJxjdIMRwbdSIYQYlwiRAzDAEUEBi2NyCAZ-TwPCEToGJ9YuEMIYYTYAs1mpN62utHKmVHA5hVY3tjX2Do7SQHUOrjpp3AYabdtGOn-Bn6WbQ1kv563TP6K2WtfawKKsansKjgpZWX22m0OQPj6k42nw8jp5Go9eAkkj7gJNCpUUSUYJjkOcZ4hjpcOMxIyRMIq1yrIsR7mO8lixRJKc-rh5jJOEUEI0HYKL3nZp2lWnrROLtjON_ygI5nHIcMQ9dN1DyrTWGl2IpSlradYCI7EtTPwpzNOXO0tplawKIxtV2r2Ecu_IsMeCHiut01_7szQfgnEPiXT2Jmj0nj7z-4nYhrjqeansb8j_AnwDHN-Fsg</recordid><startdate>19931001</startdate><enddate>19931001</enddate><creator>Wang, Juan</creator><creator>Ward, Michael D</creator><creator>Ebersole, Richard C</creator><creator>Foss, Robert P</creator><general>American Chemical Society</general><scope>BSCLL</scope><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QF</scope><scope>7QO</scope><scope>7QQ</scope><scope>7SC</scope><scope>7SE</scope><scope>7SP</scope><scope>7SR</scope><scope>7TA</scope><scope>7TB</scope><scope>7TM</scope><scope>7U5</scope><scope>7U7</scope><scope>7U9</scope><scope>8BQ</scope><scope>8FD</scope><scope>C1K</scope><scope>F28</scope><scope>FR3</scope><scope>H8D</scope><scope>H8G</scope><scope>H94</scope><scope>JG9</scope><scope>JQ2</scope><scope>KR7</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope><scope>P64</scope></search><sort><creationdate>19931001</creationdate><title>Piezoelectric pH sensors: AT-cut quartz resonators with amphoteric polymer films</title><author>Wang, Juan ; Ward, Michael D ; Ebersole, Richard C ; Foss, Robert P</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a357t-e2fc9f9b321841db071ce4b28662458ecbbbd0de5d8c69a2d3016d81992322e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1993</creationdate><topic>Analytical chemistry</topic><topic>Chemistry</topic><topic>Exact sciences and technology</topic><topic>General, instrumentation</topic><topic>Polymers</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Wang, Juan</creatorcontrib><creatorcontrib>Ward, Michael D</creatorcontrib><creatorcontrib>Ebersole, Richard C</creatorcontrib><creatorcontrib>Foss, Robert P</creatorcontrib><collection>Istex</collection><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Aluminium Industry Abstracts</collection><collection>Biotechnology Research Abstracts</collection><collection>Ceramic Abstracts</collection><collection>Computer and Information Systems Abstracts</collection><collection>Corrosion Abstracts</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Materials Business File</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Nucleic Acids Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Toxicology Abstracts</collection><collection>Virology and AIDS Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ANTE: Abstracts in New Technology &amp; Engineering</collection><collection>Engineering Research Database</collection><collection>Aerospace Database</collection><collection>Copper Technical Reference Library</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>Materials Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts – Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>Biotechnology and BioEngineering Abstracts</collection><jtitle>Analytical chemistry (Washington)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Wang, Juan</au><au>Ward, Michael D</au><au>Ebersole, Richard C</au><au>Foss, Robert P</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Piezoelectric pH sensors: AT-cut quartz resonators with amphoteric polymer films</atitle><jtitle>Analytical chemistry (Washington)</jtitle><addtitle>Anal. Chem</addtitle><date>1993-10-01</date><risdate>1993</risdate><volume>65</volume><issue>19</issue><spage>2553</spage><epage>2562</epage><pages>2553-2562</pages><issn>0003-2700</issn><eissn>1520-6882</eissn><coden>ANCHAM</coden><abstract>Piezoelectric AT-cut quartz resonators immersed in aqueous media, coated with cross-linked films of amphoteric polymer 1, exhibit large frequency changes when the pH is changed in the vicinity of the isoelectric point of the polymer film. The unique pH-sensing capabilities of the coated resonators, combined with their robustness, ease of fabrication and low cost, provide a convenient approach for the measurement of threshold pH changes.</abstract><cop>Washington, DC</cop><pub>American Chemical Society</pub><doi>10.1021/ac00067a002</doi><tpages>10</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0003-2700
ispartof Analytical chemistry (Washington), 1993-10, Vol.65 (19), p.2553-2562
issn 0003-2700
1520-6882
language eng
recordid cdi_proquest_journals_217846157
source American Chemical Society Journals
subjects Analytical chemistry
Chemistry
Exact sciences and technology
General, instrumentation
Polymers
title Piezoelectric pH sensors: AT-cut quartz resonators with amphoteric polymer films
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-30T21%3A13%3A44IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Piezoelectric%20pH%20sensors:%20AT-cut%20quartz%20resonators%20with%20amphoteric%20polymer%20films&rft.jtitle=Analytical%20chemistry%20(Washington)&rft.au=Wang,%20Juan&rft.date=1993-10-01&rft.volume=65&rft.issue=19&rft.spage=2553&rft.epage=2562&rft.pages=2553-2562&rft.issn=0003-2700&rft.eissn=1520-6882&rft.coden=ANCHAM&rft_id=info:doi/10.1021/ac00067a002&rft_dat=%3Cproquest_cross%3E7191560%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=217846157&rft_id=info:pmid/&rfr_iscdi=true