Reduction of Water Waste in an Organic Chemistry Laboratory Using a Low-Cost Recirculation System for Condenser Apparatus
A low-cost and easy-to-use water recirculation system for a condenser apparatus was designed and installed in an organic chemistry teaching laboratory. Relying on gravity and a small pump for water circulation, it supplies four stations simultaneously. The water recirculation system works very well...
Gespeichert in:
Veröffentlicht in: | Journal of chemical education 2019-01, Vol.96 (1), p.180-182 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 182 |
---|---|
container_issue | 1 |
container_start_page | 180 |
container_title | Journal of chemical education |
container_volume | 96 |
creator | Schoeddert, Alex Babooram, Keshwaree Pelletier, Sarah |
description | A low-cost and easy-to-use water recirculation system for a condenser apparatus was designed and installed in an organic chemistry teaching laboratory. Relying on gravity and a small pump for water circulation, it supplies four stations simultaneously. The water recirculation system works very well with condensers used for distillation and reflux reactions, as well as with rotary evaporators. This innovative idea has led to an annual water savings of more than 14 400 L while running only 2 lab periods per week with up to 24 students per period. Its low cost and easy installation make it convenient and easily adoptable by any laboratory where the waste of water from condensers needs to be addressed, especially in places where water scarcity is already hindering such significant scientific activities. |
doi_str_mv | 10.1021/acs.jchemed.8b00400 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2170805677</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ericid>EJ1202231</ericid><sourcerecordid>2170805677</sourcerecordid><originalsourceid>FETCH-LOGICAL-a339t-a72b8fd562f0791a5bea9439c37359de19aad9e9b5058275b1639c84797115893</originalsourceid><addsrcrecordid>eNp9kN1LwzAUxYMoOKd_gQgBn7vlo1mSx1HmF4PBdPhYbtN0dmxNTVpk_71xmz76cu-Fc87vwkHolpIRJYyOwYTRxnzYnS1HqiAkJeQMDajmKqGcqXM0INGWaKHSS3QVwoYQyoRWA7Rf2rI3Xe0a7Cr8Dp31cYbO4rrB0OCFX0NTG5xFeB06v8dzKJyHzsVzFepmjQHP3VeSudDhpTW1N_0WDsDXfeTscOU8zlxT2iZE-LRtIcb7cI0uKtgGe3PaQ7R6mL1lT8l88ficTecJcK67BCQrVFWKCauI1BREYUGnXBsuudClpRqg1FYXggjFpCjoJIoqlVpSKpTmQ3R_5LbeffY2dPnG9b6JL3NGJVFETKSMLn50Ge9C8LbKW1_vwO9zSvKfjvPYcX7qOD91HFN3x5T1tflLzF4oI4xxGvXxUT-Ef9_-R_wGE5GMBw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2170805677</pqid></control><display><type>article</type><title>Reduction of Water Waste in an Organic Chemistry Laboratory Using a Low-Cost Recirculation System for Condenser Apparatus</title><source>ACS Publications</source><creator>Schoeddert, Alex ; Babooram, Keshwaree ; Pelletier, Sarah</creator><creatorcontrib>Schoeddert, Alex ; Babooram, Keshwaree ; Pelletier, Sarah</creatorcontrib><description>A low-cost and easy-to-use water recirculation system for a condenser apparatus was designed and installed in an organic chemistry teaching laboratory. Relying on gravity and a small pump for water circulation, it supplies four stations simultaneously. The water recirculation system works very well with condensers used for distillation and reflux reactions, as well as with rotary evaporators. This innovative idea has led to an annual water savings of more than 14 400 L while running only 2 lab periods per week with up to 24 students per period. Its low cost and easy installation make it convenient and easily adoptable by any laboratory where the waste of water from condensers needs to be addressed, especially in places where water scarcity is already hindering such significant scientific activities.</description><identifier>ISSN: 0021-9584</identifier><identifier>EISSN: 1938-1328</identifier><identifier>DOI: 10.1021/acs.jchemed.8b00400</identifier><language>eng</language><publisher>Easton: American Chemical Society and Division of Chemical Education, Inc</publisher><subject>Condensers ; Condensers (liquefiers) ; Cost Effectiveness ; Distillation ; Distilled water ; Evaporators ; Green chemistry ; Laboratories ; Low cost ; Organic Chemistry ; Recirculating systems ; Sanitation ; Science Equipment ; Science Laboratories ; Water ; Water circulation ; Water Quality ; Water scarcity</subject><ispartof>Journal of chemical education, 2019-01, Vol.96 (1), p.180-182</ispartof><rights>Copyright American Chemical Society Jan 8, 2019</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a339t-a72b8fd562f0791a5bea9439c37359de19aad9e9b5058275b1639c84797115893</citedby><cites>FETCH-LOGICAL-a339t-a72b8fd562f0791a5bea9439c37359de19aad9e9b5058275b1639c84797115893</cites><orcidid>0000-0001-7128-9356</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://pubs.acs.org/doi/pdf/10.1021/acs.jchemed.8b00400$$EPDF$$P50$$Gacs$$H</linktopdf><linktohtml>$$Uhttps://pubs.acs.org/doi/10.1021/acs.jchemed.8b00400$$EHTML$$P50$$Gacs$$H</linktohtml><link.rule.ids>314,777,781,2752,27057,27905,27906,56719,56769</link.rule.ids><backlink>$$Uhttp://eric.ed.gov/ERICWebPortal/detail?accno=EJ1202231$$DView record in ERIC$$Hfree_for_read</backlink></links><search><creatorcontrib>Schoeddert, Alex</creatorcontrib><creatorcontrib>Babooram, Keshwaree</creatorcontrib><creatorcontrib>Pelletier, Sarah</creatorcontrib><title>Reduction of Water Waste in an Organic Chemistry Laboratory Using a Low-Cost Recirculation System for Condenser Apparatus</title><title>Journal of chemical education</title><addtitle>J. Chem. Educ</addtitle><description>A low-cost and easy-to-use water recirculation system for a condenser apparatus was designed and installed in an organic chemistry teaching laboratory. Relying on gravity and a small pump for water circulation, it supplies four stations simultaneously. The water recirculation system works very well with condensers used for distillation and reflux reactions, as well as with rotary evaporators. This innovative idea has led to an annual water savings of more than 14 400 L while running only 2 lab periods per week with up to 24 students per period. Its low cost and easy installation make it convenient and easily adoptable by any laboratory where the waste of water from condensers needs to be addressed, especially in places where water scarcity is already hindering such significant scientific activities.</description><subject>Condensers</subject><subject>Condensers (liquefiers)</subject><subject>Cost Effectiveness</subject><subject>Distillation</subject><subject>Distilled water</subject><subject>Evaporators</subject><subject>Green chemistry</subject><subject>Laboratories</subject><subject>Low cost</subject><subject>Organic Chemistry</subject><subject>Recirculating systems</subject><subject>Sanitation</subject><subject>Science Equipment</subject><subject>Science Laboratories</subject><subject>Water</subject><subject>Water circulation</subject><subject>Water Quality</subject><subject>Water scarcity</subject><issn>0021-9584</issn><issn>1938-1328</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNp9kN1LwzAUxYMoOKd_gQgBn7vlo1mSx1HmF4PBdPhYbtN0dmxNTVpk_71xmz76cu-Fc87vwkHolpIRJYyOwYTRxnzYnS1HqiAkJeQMDajmKqGcqXM0INGWaKHSS3QVwoYQyoRWA7Rf2rI3Xe0a7Cr8Dp31cYbO4rrB0OCFX0NTG5xFeB06v8dzKJyHzsVzFepmjQHP3VeSudDhpTW1N_0WDsDXfeTscOU8zlxT2iZE-LRtIcb7cI0uKtgGe3PaQ7R6mL1lT8l88ficTecJcK67BCQrVFWKCauI1BREYUGnXBsuudClpRqg1FYXggjFpCjoJIoqlVpSKpTmQ3R_5LbeffY2dPnG9b6JL3NGJVFETKSMLn50Ge9C8LbKW1_vwO9zSvKfjvPYcX7qOD91HFN3x5T1tflLzF4oI4xxGvXxUT-Ef9_-R_wGE5GMBw</recordid><startdate>20190108</startdate><enddate>20190108</enddate><creator>Schoeddert, Alex</creator><creator>Babooram, Keshwaree</creator><creator>Pelletier, Sarah</creator><general>American Chemical Society and Division of Chemical Education, Inc</general><general>Division of Chemical Education, Inc</general><general>American Chemical Society</general><scope>7SW</scope><scope>BJH</scope><scope>BNH</scope><scope>BNI</scope><scope>BNJ</scope><scope>BNO</scope><scope>ERI</scope><scope>PET</scope><scope>REK</scope><scope>WWN</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>K9.</scope><orcidid>https://orcid.org/0000-0001-7128-9356</orcidid></search><sort><creationdate>20190108</creationdate><title>Reduction of Water Waste in an Organic Chemistry Laboratory Using a Low-Cost Recirculation System for Condenser Apparatus</title><author>Schoeddert, Alex ; Babooram, Keshwaree ; Pelletier, Sarah</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a339t-a72b8fd562f0791a5bea9439c37359de19aad9e9b5058275b1639c84797115893</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Condensers</topic><topic>Condensers (liquefiers)</topic><topic>Cost Effectiveness</topic><topic>Distillation</topic><topic>Distilled water</topic><topic>Evaporators</topic><topic>Green chemistry</topic><topic>Laboratories</topic><topic>Low cost</topic><topic>Organic Chemistry</topic><topic>Recirculating systems</topic><topic>Sanitation</topic><topic>Science Equipment</topic><topic>Science Laboratories</topic><topic>Water</topic><topic>Water circulation</topic><topic>Water Quality</topic><topic>Water scarcity</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Schoeddert, Alex</creatorcontrib><creatorcontrib>Babooram, Keshwaree</creatorcontrib><creatorcontrib>Pelletier, Sarah</creatorcontrib><collection>ERIC</collection><collection>ERIC (Ovid)</collection><collection>ERIC</collection><collection>ERIC</collection><collection>ERIC (Legacy Platform)</collection><collection>ERIC( SilverPlatter )</collection><collection>ERIC</collection><collection>ERIC PlusText (Legacy Platform)</collection><collection>Education Resources Information Center (ERIC)</collection><collection>ERIC</collection><collection>CrossRef</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><jtitle>Journal of chemical education</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Schoeddert, Alex</au><au>Babooram, Keshwaree</au><au>Pelletier, Sarah</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><ericid>EJ1202231</ericid><atitle>Reduction of Water Waste in an Organic Chemistry Laboratory Using a Low-Cost Recirculation System for Condenser Apparatus</atitle><jtitle>Journal of chemical education</jtitle><addtitle>J. Chem. Educ</addtitle><date>2019-01-08</date><risdate>2019</risdate><volume>96</volume><issue>1</issue><spage>180</spage><epage>182</epage><pages>180-182</pages><issn>0021-9584</issn><eissn>1938-1328</eissn><abstract>A low-cost and easy-to-use water recirculation system for a condenser apparatus was designed and installed in an organic chemistry teaching laboratory. Relying on gravity and a small pump for water circulation, it supplies four stations simultaneously. The water recirculation system works very well with condensers used for distillation and reflux reactions, as well as with rotary evaporators. This innovative idea has led to an annual water savings of more than 14 400 L while running only 2 lab periods per week with up to 24 students per period. Its low cost and easy installation make it convenient and easily adoptable by any laboratory where the waste of water from condensers needs to be addressed, especially in places where water scarcity is already hindering such significant scientific activities.</abstract><cop>Easton</cop><pub>American Chemical Society and Division of Chemical Education, Inc</pub><doi>10.1021/acs.jchemed.8b00400</doi><tpages>3</tpages><orcidid>https://orcid.org/0000-0001-7128-9356</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0021-9584 |
ispartof | Journal of chemical education, 2019-01, Vol.96 (1), p.180-182 |
issn | 0021-9584 1938-1328 |
language | eng |
recordid | cdi_proquest_journals_2170805677 |
source | ACS Publications |
subjects | Condensers Condensers (liquefiers) Cost Effectiveness Distillation Distilled water Evaporators Green chemistry Laboratories Low cost Organic Chemistry Recirculating systems Sanitation Science Equipment Science Laboratories Water Water circulation Water Quality Water scarcity |
title | Reduction of Water Waste in an Organic Chemistry Laboratory Using a Low-Cost Recirculation System for Condenser Apparatus |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-18T11%3A55%3A56IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Reduction%20of%20Water%20Waste%20in%20an%20Organic%20Chemistry%20Laboratory%20Using%20a%20Low-Cost%20Recirculation%20System%20for%20Condenser%20Apparatus&rft.jtitle=Journal%20of%20chemical%20education&rft.au=Schoeddert,%20Alex&rft.date=2019-01-08&rft.volume=96&rft.issue=1&rft.spage=180&rft.epage=182&rft.pages=180-182&rft.issn=0021-9584&rft.eissn=1938-1328&rft_id=info:doi/10.1021/acs.jchemed.8b00400&rft_dat=%3Cproquest_cross%3E2170805677%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2170805677&rft_id=info:pmid/&rft_ericid=EJ1202231&rfr_iscdi=true |