Anterior Cruciate Ligament Graft Fixation

The initial biomechanical properties of semitendinosus and patellar tendon autografts and their fixation strengths were investigated. Twenty fresh cadaveric knees from donors under 42 years of age were used in the study. After removing all soft tissues other than the anterior cruciate ligament, we d...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The American journal of sports medicine 1997-07, Vol.25 (4), p.472
Hauptverfasser: Rowden, Neville J, Sher, Doron, Rogers, Greg J, Schindhelm, Klaus
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 4
container_start_page 472
container_title The American journal of sports medicine
container_volume 25
creator Rowden, Neville J
Sher, Doron
Rogers, Greg J
Schindhelm, Klaus
description The initial biomechanical properties of semitendinosus and patellar tendon autografts and their fixation strengths were investigated. Twenty fresh cadaveric knees from donors under 42 years of age were used in the study. After removing all soft tissues other than the anterior cruciate ligament, we determined the ultimate tensile strength (2195 ± 427 N) and stiffness (306 ± 80 N/mm) of the anterior cruciate ligament in nine knees. In six knees, anterior cruciate ligaments were reconstructed using an autologous patellar tendon graft with proximal and distal interference fit screws; this resulted in an ultimate tensile strength of 416 ± 66 N. Five knees were reconstructed with quadruple- stranded (double-looped) semitendinosus tendons fixed proximally by a titanium button and braided tape and distally by tibial post screw. This resulted in an ultimate tensile strength of 612 ± 73 N, which was significantly higher than the strength in the patellar tendon group. Graft stiffness did not differ between the groups and was 47 ± 19 N/mm (N = 11). This study demonstrates that the reconstructed knees had only 20% to 30% of the ultimate tensile strength of the normal anterior cruciate ligament. In summary, the semitendinosus reconstruction using a button for prox imal fixation is, at the time of surgery, approximately 50% stronger than patellar tendon reconstructions with similar stiffness.
doi_str_mv 10.1177/036354659702500409
format Article
fullrecord <record><control><sourceid>proquest_highw</sourceid><recordid>TN_cdi_proquest_journals_217063012</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>13259939</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1352-4a7361dd7c426c33f3281e86e0be10e3511d5fa0d1a4aecad5aaa720209312e93</originalsourceid><addsrcrecordid>eNotzU1Lw0AUheFBFIzVP-AqCC5cRO-dOx_JsgRbhYAbXYfbZNJOSJM6SdCfb0tdnc3DeYW4R3hGtPYFyJBWRmcWpAZQkF2ICLWWCZHRlyI6geQkrsXNOLYAgNakkXha9pMLfghxHubK8-Tiwm957_opXgdupnjlf3nyQ38rrhruRnf3vwvxtXr9zN-S4mP9ni-LpEI69hRbMljXtlLSVEQNyRRdahxsHIIjjVjrhqFGVuwqrjUzWwkSMkLpMlqIh_PvIQzfsxunsh3m0B-TpUQLhgDlET2e0c5vdz8-uHLcc9cd5g2V3I5Sl6pUVtIffEdPAg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>217063012</pqid></control><display><type>article</type><title>Anterior Cruciate Ligament Graft Fixation</title><source>Access via SAGE</source><source>Alma/SFX Local Collection</source><creator>Rowden, Neville J ; Sher, Doron ; Rogers, Greg J ; Schindhelm, Klaus</creator><creatorcontrib>Rowden, Neville J ; Sher, Doron ; Rogers, Greg J ; Schindhelm, Klaus</creatorcontrib><description>The initial biomechanical properties of semitendinosus and patellar tendon autografts and their fixation strengths were investigated. Twenty fresh cadaveric knees from donors under 42 years of age were used in the study. After removing all soft tissues other than the anterior cruciate ligament, we determined the ultimate tensile strength (2195 ± 427 N) and stiffness (306 ± 80 N/mm) of the anterior cruciate ligament in nine knees. In six knees, anterior cruciate ligaments were reconstructed using an autologous patellar tendon graft with proximal and distal interference fit screws; this resulted in an ultimate tensile strength of 416 ± 66 N. Five knees were reconstructed with quadruple- stranded (double-looped) semitendinosus tendons fixed proximally by a titanium button and braided tape and distally by tibial post screw. This resulted in an ultimate tensile strength of 612 ± 73 N, which was significantly higher than the strength in the patellar tendon group. Graft stiffness did not differ between the groups and was 47 ± 19 N/mm (N = 11). This study demonstrates that the reconstructed knees had only 20% to 30% of the ultimate tensile strength of the normal anterior cruciate ligament. In summary, the semitendinosus reconstruction using a button for prox imal fixation is, at the time of surgery, approximately 50% stronger than patellar tendon reconstructions with similar stiffness.</description><identifier>ISSN: 0363-5465</identifier><identifier>EISSN: 1552-3365</identifier><identifier>DOI: 10.1177/036354659702500409</identifier><identifier>CODEN: AJSMDO</identifier><language>eng</language><publisher>Baltimore: American Orthopaedic Society for Sports Medicine</publisher><subject>Knee ; Ligaments ; Sports medicine ; Tendons</subject><ispartof>The American journal of sports medicine, 1997-07, Vol.25 (4), p.472</ispartof><rights>Copyright American Journal of Sports Medicine Jul/Aug 1997</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c1352-4a7361dd7c426c33f3281e86e0be10e3511d5fa0d1a4aecad5aaa720209312e93</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>315,782,786,27933,27934</link.rule.ids></links><search><creatorcontrib>Rowden, Neville J</creatorcontrib><creatorcontrib>Sher, Doron</creatorcontrib><creatorcontrib>Rogers, Greg J</creatorcontrib><creatorcontrib>Schindhelm, Klaus</creatorcontrib><title>Anterior Cruciate Ligament Graft Fixation</title><title>The American journal of sports medicine</title><description>The initial biomechanical properties of semitendinosus and patellar tendon autografts and their fixation strengths were investigated. Twenty fresh cadaveric knees from donors under 42 years of age were used in the study. After removing all soft tissues other than the anterior cruciate ligament, we determined the ultimate tensile strength (2195 ± 427 N) and stiffness (306 ± 80 N/mm) of the anterior cruciate ligament in nine knees. In six knees, anterior cruciate ligaments were reconstructed using an autologous patellar tendon graft with proximal and distal interference fit screws; this resulted in an ultimate tensile strength of 416 ± 66 N. Five knees were reconstructed with quadruple- stranded (double-looped) semitendinosus tendons fixed proximally by a titanium button and braided tape and distally by tibial post screw. This resulted in an ultimate tensile strength of 612 ± 73 N, which was significantly higher than the strength in the patellar tendon group. Graft stiffness did not differ between the groups and was 47 ± 19 N/mm (N = 11). This study demonstrates that the reconstructed knees had only 20% to 30% of the ultimate tensile strength of the normal anterior cruciate ligament. In summary, the semitendinosus reconstruction using a button for prox imal fixation is, at the time of surgery, approximately 50% stronger than patellar tendon reconstructions with similar stiffness.</description><subject>Knee</subject><subject>Ligaments</subject><subject>Sports medicine</subject><subject>Tendons</subject><issn>0363-5465</issn><issn>1552-3365</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1997</creationdate><recordtype>article</recordtype><recordid>eNotzU1Lw0AUheFBFIzVP-AqCC5cRO-dOx_JsgRbhYAbXYfbZNJOSJM6SdCfb0tdnc3DeYW4R3hGtPYFyJBWRmcWpAZQkF2ICLWWCZHRlyI6geQkrsXNOLYAgNakkXha9pMLfghxHubK8-Tiwm957_opXgdupnjlf3nyQ38rrhruRnf3vwvxtXr9zN-S4mP9ni-LpEI69hRbMljXtlLSVEQNyRRdahxsHIIjjVjrhqFGVuwqrjUzWwkSMkLpMlqIh_PvIQzfsxunsh3m0B-TpUQLhgDlET2e0c5vdz8-uHLcc9cd5g2V3I5Sl6pUVtIffEdPAg</recordid><startdate>19970701</startdate><enddate>19970701</enddate><creator>Rowden, Neville J</creator><creator>Sher, Doron</creator><creator>Rogers, Greg J</creator><creator>Schindhelm, Klaus</creator><general>American Orthopaedic Society for Sports Medicine</general><general>Sage Publications Ltd</general><scope>7TS</scope><scope>K9.</scope><scope>NAPCQ</scope><scope>U9A</scope></search><sort><creationdate>19970701</creationdate><title>Anterior Cruciate Ligament Graft Fixation</title><author>Rowden, Neville J ; Sher, Doron ; Rogers, Greg J ; Schindhelm, Klaus</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1352-4a7361dd7c426c33f3281e86e0be10e3511d5fa0d1a4aecad5aaa720209312e93</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1997</creationdate><topic>Knee</topic><topic>Ligaments</topic><topic>Sports medicine</topic><topic>Tendons</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Rowden, Neville J</creatorcontrib><creatorcontrib>Sher, Doron</creatorcontrib><creatorcontrib>Rogers, Greg J</creatorcontrib><creatorcontrib>Schindhelm, Klaus</creatorcontrib><collection>Physical Education Index</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Nursing &amp; Allied Health Premium</collection><jtitle>The American journal of sports medicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Rowden, Neville J</au><au>Sher, Doron</au><au>Rogers, Greg J</au><au>Schindhelm, Klaus</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Anterior Cruciate Ligament Graft Fixation</atitle><jtitle>The American journal of sports medicine</jtitle><date>1997-07-01</date><risdate>1997</risdate><volume>25</volume><issue>4</issue><spage>472</spage><pages>472-</pages><issn>0363-5465</issn><eissn>1552-3365</eissn><coden>AJSMDO</coden><abstract>The initial biomechanical properties of semitendinosus and patellar tendon autografts and their fixation strengths were investigated. Twenty fresh cadaveric knees from donors under 42 years of age were used in the study. After removing all soft tissues other than the anterior cruciate ligament, we determined the ultimate tensile strength (2195 ± 427 N) and stiffness (306 ± 80 N/mm) of the anterior cruciate ligament in nine knees. In six knees, anterior cruciate ligaments were reconstructed using an autologous patellar tendon graft with proximal and distal interference fit screws; this resulted in an ultimate tensile strength of 416 ± 66 N. Five knees were reconstructed with quadruple- stranded (double-looped) semitendinosus tendons fixed proximally by a titanium button and braided tape and distally by tibial post screw. This resulted in an ultimate tensile strength of 612 ± 73 N, which was significantly higher than the strength in the patellar tendon group. Graft stiffness did not differ between the groups and was 47 ± 19 N/mm (N = 11). This study demonstrates that the reconstructed knees had only 20% to 30% of the ultimate tensile strength of the normal anterior cruciate ligament. In summary, the semitendinosus reconstruction using a button for prox imal fixation is, at the time of surgery, approximately 50% stronger than patellar tendon reconstructions with similar stiffness.</abstract><cop>Baltimore</cop><pub>American Orthopaedic Society for Sports Medicine</pub><doi>10.1177/036354659702500409</doi></addata></record>
fulltext fulltext
identifier ISSN: 0363-5465
ispartof The American journal of sports medicine, 1997-07, Vol.25 (4), p.472
issn 0363-5465
1552-3365
language eng
recordid cdi_proquest_journals_217063012
source Access via SAGE; Alma/SFX Local Collection
subjects Knee
Ligaments
Sports medicine
Tendons
title Anterior Cruciate Ligament Graft Fixation
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-02T13%3A54%3A18IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_highw&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Anterior%20Cruciate%20Ligament%20Graft%20Fixation&rft.jtitle=The%20American%20journal%20of%20sports%20medicine&rft.au=Rowden,%20Neville%20J&rft.date=1997-07-01&rft.volume=25&rft.issue=4&rft.spage=472&rft.pages=472-&rft.issn=0363-5465&rft.eissn=1552-3365&rft.coden=AJSMDO&rft_id=info:doi/10.1177/036354659702500409&rft_dat=%3Cproquest_highw%3E13259939%3C/proquest_highw%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=217063012&rft_id=info:pmid/&rfr_iscdi=true