Neutron spectra from Neutron Standards Laboratory (LPN/CIEMAT) sources with two Bonner sphere spectrometers

The Neutron Standards Laboratory (LPN: Laboratorio de Patrones Neutrónicos) of the Ionizing Radiation Metrology Laboratory (LMRI) of the CIEMAT (Centro de Investigaciones Energéticas Medioambientales y Tecnológicas) has two calibration neutron sources, 241Am-Be and 252Cf. Studies to verify the shiel...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Radiation physics and chemistry (Oxford, England : 1993) England : 1993), 2019-02, Vol.155, p.97-100
Hauptverfasser: Méndez-Villafañe, R., Lacerda, M.A.S., Campo, X., Lorente, A., Ibañez, S., Gallego, E., Vega-Carrillo, H.R.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 100
container_issue
container_start_page 97
container_title Radiation physics and chemistry (Oxford, England : 1993)
container_volume 155
creator Méndez-Villafañe, R.
Lacerda, M.A.S.
Campo, X.
Lorente, A.
Ibañez, S.
Gallego, E.
Vega-Carrillo, H.R.
description The Neutron Standards Laboratory (LPN: Laboratorio de Patrones Neutrónicos) of the Ionizing Radiation Metrology Laboratory (LMRI) of the CIEMAT (Centro de Investigaciones Energéticas Medioambientales y Tecnológicas) has two calibration neutron sources, 241Am-Be and 252Cf. Studies to verify the shielding of the facility and to characterize the neutron field in the irradiation room have been carried out using Monte Carlo methods. However, spectral measurements were not performed yet. In this study, we measured the total and direct neutron spectra of both calibration neutron sources. Two different Bonner Sphere Spectrometers (BSS) systems were allocated to 115 cm from the sources, on the calibration bench, with and without the shadow cones (SC). From the count rates obtained with both BSS systems (BSS-6LiI and BSS-3He), the total neutron spectrum and direct neutron spectrum were unfolded. Total and direct spectra obtained for the 241Am-Be and 252Cf sources with the MCNPX and different BSS systems, unfold codes and response matrices presented similar shape and are consistent with each other. •Measurement of the neutron spectra of 241Am-Be and 252Cf sources of the LPN/CIEMAT.•Total and direct spectra obtained with the MCNPX and different BSS spectrometers.•Use of different unfolding codes and response matrices.•Total and direct spectra and integral quantities were consistent with each other.
doi_str_mv 10.1016/j.radphyschem.2018.06.015
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2162995605</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0969806X17307363</els_id><sourcerecordid>2162995605</sourcerecordid><originalsourceid>FETCH-LOGICAL-c349t-b5f00b141b5fd51a5c396767f9c4a22518715ea0ce99023502ea4f6cff305d633</originalsourceid><addsrcrecordid>eNqNkE1LAzEQhoMoWD_-Q8SLHnY72W3SzVFL_YBaBRW8hTQ7S7faTZ2kSv-9kSp49DTD8M4z876MnQjIBQjVX-Rk69V8E9wcl3kBospB5SDkDuuJaqgzqLTcZT3QSmcVqJd9dhDCAgCGlSx77HWK60i-42GFLpLlDfkl_x0-RtvVlurAJ3bmyUZPG342eZj2R7fju4uncx78mhwG_tnGOY-fnl_6rkNKuDkS_lD9EiNSOGJ7jX0LePxTD9nz1fhpdJNN7q9vRxeTzJUDHbOZbABmYiBSU0thpSu1Gqpho93AFoVMtoRECw61hqKUUKAdNMo1TQmyVmV5yE633BX59zWGaBbpyy6dNIVQhdZSgUwqvVU58iEQNmZF7dLSxggw39mahfmTrfnO1oAyKdu0O9ruYrLx0SKZ4FrsHNYtJcOm9u0_KF8pHYl0</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2162995605</pqid></control><display><type>article</type><title>Neutron spectra from Neutron Standards Laboratory (LPN/CIEMAT) sources with two Bonner sphere spectrometers</title><source>Access via ScienceDirect (Elsevier)</source><creator>Méndez-Villafañe, R. ; Lacerda, M.A.S. ; Campo, X. ; Lorente, A. ; Ibañez, S. ; Gallego, E. ; Vega-Carrillo, H.R.</creator><creatorcontrib>Méndez-Villafañe, R. ; Lacerda, M.A.S. ; Campo, X. ; Lorente, A. ; Ibañez, S. ; Gallego, E. ; Vega-Carrillo, H.R.</creatorcontrib><description>The Neutron Standards Laboratory (LPN: Laboratorio de Patrones Neutrónicos) of the Ionizing Radiation Metrology Laboratory (LMRI) of the CIEMAT (Centro de Investigaciones Energéticas Medioambientales y Tecnológicas) has two calibration neutron sources, 241Am-Be and 252Cf. Studies to verify the shielding of the facility and to characterize the neutron field in the irradiation room have been carried out using Monte Carlo methods. However, spectral measurements were not performed yet. In this study, we measured the total and direct neutron spectra of both calibration neutron sources. Two different Bonner Sphere Spectrometers (BSS) systems were allocated to 115 cm from the sources, on the calibration bench, with and without the shadow cones (SC). From the count rates obtained with both BSS systems (BSS-6LiI and BSS-3He), the total neutron spectrum and direct neutron spectrum were unfolded. Total and direct spectra obtained for the 241Am-Be and 252Cf sources with the MCNPX and different BSS systems, unfold codes and response matrices presented similar shape and are consistent with each other. •Measurement of the neutron spectra of 241Am-Be and 252Cf sources of the LPN/CIEMAT.•Total and direct spectra obtained with the MCNPX and different BSS spectrometers.•Use of different unfolding codes and response matrices.•Total and direct spectra and integral quantities were consistent with each other.</description><identifier>ISSN: 0969-806X</identifier><identifier>EISSN: 1879-0895</identifier><identifier>DOI: 10.1016/j.radphyschem.2018.06.015</identifier><language>eng</language><publisher>Oxford: Elsevier Ltd</publisher><subject>Calibration ; Californium isotopes ; Cones ; Ionizing radiation ; Measurement methods ; Monte Carlo simulation ; Neutron sources ; Neutron spectra ; Neutrons ; Radiation shielding ; Scientific imaging ; Spectrometers</subject><ispartof>Radiation physics and chemistry (Oxford, England : 1993), 2019-02, Vol.155, p.97-100</ispartof><rights>2018 Elsevier Ltd</rights><rights>Copyright Elsevier BV Feb 2019</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c349t-b5f00b141b5fd51a5c396767f9c4a22518715ea0ce99023502ea4f6cff305d633</citedby><cites>FETCH-LOGICAL-c349t-b5f00b141b5fd51a5c396767f9c4a22518715ea0ce99023502ea4f6cff305d633</cites><orcidid>0000-0001-8338-4959</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.radphyschem.2018.06.015$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids></links><search><creatorcontrib>Méndez-Villafañe, R.</creatorcontrib><creatorcontrib>Lacerda, M.A.S.</creatorcontrib><creatorcontrib>Campo, X.</creatorcontrib><creatorcontrib>Lorente, A.</creatorcontrib><creatorcontrib>Ibañez, S.</creatorcontrib><creatorcontrib>Gallego, E.</creatorcontrib><creatorcontrib>Vega-Carrillo, H.R.</creatorcontrib><title>Neutron spectra from Neutron Standards Laboratory (LPN/CIEMAT) sources with two Bonner sphere spectrometers</title><title>Radiation physics and chemistry (Oxford, England : 1993)</title><description>The Neutron Standards Laboratory (LPN: Laboratorio de Patrones Neutrónicos) of the Ionizing Radiation Metrology Laboratory (LMRI) of the CIEMAT (Centro de Investigaciones Energéticas Medioambientales y Tecnológicas) has two calibration neutron sources, 241Am-Be and 252Cf. Studies to verify the shielding of the facility and to characterize the neutron field in the irradiation room have been carried out using Monte Carlo methods. However, spectral measurements were not performed yet. In this study, we measured the total and direct neutron spectra of both calibration neutron sources. Two different Bonner Sphere Spectrometers (BSS) systems were allocated to 115 cm from the sources, on the calibration bench, with and without the shadow cones (SC). From the count rates obtained with both BSS systems (BSS-6LiI and BSS-3He), the total neutron spectrum and direct neutron spectrum were unfolded. Total and direct spectra obtained for the 241Am-Be and 252Cf sources with the MCNPX and different BSS systems, unfold codes and response matrices presented similar shape and are consistent with each other. •Measurement of the neutron spectra of 241Am-Be and 252Cf sources of the LPN/CIEMAT.•Total and direct spectra obtained with the MCNPX and different BSS spectrometers.•Use of different unfolding codes and response matrices.•Total and direct spectra and integral quantities were consistent with each other.</description><subject>Calibration</subject><subject>Californium isotopes</subject><subject>Cones</subject><subject>Ionizing radiation</subject><subject>Measurement methods</subject><subject>Monte Carlo simulation</subject><subject>Neutron sources</subject><subject>Neutron spectra</subject><subject>Neutrons</subject><subject>Radiation shielding</subject><subject>Scientific imaging</subject><subject>Spectrometers</subject><issn>0969-806X</issn><issn>1879-0895</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNqNkE1LAzEQhoMoWD_-Q8SLHnY72W3SzVFL_YBaBRW8hTQ7S7faTZ2kSv-9kSp49DTD8M4z876MnQjIBQjVX-Rk69V8E9wcl3kBospB5SDkDuuJaqgzqLTcZT3QSmcVqJd9dhDCAgCGlSx77HWK60i-42GFLpLlDfkl_x0-RtvVlurAJ3bmyUZPG342eZj2R7fju4uncx78mhwG_tnGOY-fnl_6rkNKuDkS_lD9EiNSOGJ7jX0LePxTD9nz1fhpdJNN7q9vRxeTzJUDHbOZbABmYiBSU0thpSu1Gqpho93AFoVMtoRECw61hqKUUKAdNMo1TQmyVmV5yE633BX59zWGaBbpyy6dNIVQhdZSgUwqvVU58iEQNmZF7dLSxggw39mahfmTrfnO1oAyKdu0O9ruYrLx0SKZ4FrsHNYtJcOm9u0_KF8pHYl0</recordid><startdate>201902</startdate><enddate>201902</enddate><creator>Méndez-Villafañe, R.</creator><creator>Lacerda, M.A.S.</creator><creator>Campo, X.</creator><creator>Lorente, A.</creator><creator>Ibañez, S.</creator><creator>Gallego, E.</creator><creator>Vega-Carrillo, H.R.</creator><general>Elsevier Ltd</general><general>Elsevier BV</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SR</scope><scope>7U5</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope><scope>L7M</scope><orcidid>https://orcid.org/0000-0001-8338-4959</orcidid></search><sort><creationdate>201902</creationdate><title>Neutron spectra from Neutron Standards Laboratory (LPN/CIEMAT) sources with two Bonner sphere spectrometers</title><author>Méndez-Villafañe, R. ; Lacerda, M.A.S. ; Campo, X. ; Lorente, A. ; Ibañez, S. ; Gallego, E. ; Vega-Carrillo, H.R.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c349t-b5f00b141b5fd51a5c396767f9c4a22518715ea0ce99023502ea4f6cff305d633</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Calibration</topic><topic>Californium isotopes</topic><topic>Cones</topic><topic>Ionizing radiation</topic><topic>Measurement methods</topic><topic>Monte Carlo simulation</topic><topic>Neutron sources</topic><topic>Neutron spectra</topic><topic>Neutrons</topic><topic>Radiation shielding</topic><topic>Scientific imaging</topic><topic>Spectrometers</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Méndez-Villafañe, R.</creatorcontrib><creatorcontrib>Lacerda, M.A.S.</creatorcontrib><creatorcontrib>Campo, X.</creatorcontrib><creatorcontrib>Lorente, A.</creatorcontrib><creatorcontrib>Ibañez, S.</creatorcontrib><creatorcontrib>Gallego, E.</creatorcontrib><creatorcontrib>Vega-Carrillo, H.R.</creatorcontrib><collection>CrossRef</collection><collection>Engineered Materials Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Radiation physics and chemistry (Oxford, England : 1993)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Méndez-Villafañe, R.</au><au>Lacerda, M.A.S.</au><au>Campo, X.</au><au>Lorente, A.</au><au>Ibañez, S.</au><au>Gallego, E.</au><au>Vega-Carrillo, H.R.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Neutron spectra from Neutron Standards Laboratory (LPN/CIEMAT) sources with two Bonner sphere spectrometers</atitle><jtitle>Radiation physics and chemistry (Oxford, England : 1993)</jtitle><date>2019-02</date><risdate>2019</risdate><volume>155</volume><spage>97</spage><epage>100</epage><pages>97-100</pages><issn>0969-806X</issn><eissn>1879-0895</eissn><abstract>The Neutron Standards Laboratory (LPN: Laboratorio de Patrones Neutrónicos) of the Ionizing Radiation Metrology Laboratory (LMRI) of the CIEMAT (Centro de Investigaciones Energéticas Medioambientales y Tecnológicas) has two calibration neutron sources, 241Am-Be and 252Cf. Studies to verify the shielding of the facility and to characterize the neutron field in the irradiation room have been carried out using Monte Carlo methods. However, spectral measurements were not performed yet. In this study, we measured the total and direct neutron spectra of both calibration neutron sources. Two different Bonner Sphere Spectrometers (BSS) systems were allocated to 115 cm from the sources, on the calibration bench, with and without the shadow cones (SC). From the count rates obtained with both BSS systems (BSS-6LiI and BSS-3He), the total neutron spectrum and direct neutron spectrum were unfolded. Total and direct spectra obtained for the 241Am-Be and 252Cf sources with the MCNPX and different BSS systems, unfold codes and response matrices presented similar shape and are consistent with each other. •Measurement of the neutron spectra of 241Am-Be and 252Cf sources of the LPN/CIEMAT.•Total and direct spectra obtained with the MCNPX and different BSS spectrometers.•Use of different unfolding codes and response matrices.•Total and direct spectra and integral quantities were consistent with each other.</abstract><cop>Oxford</cop><pub>Elsevier Ltd</pub><doi>10.1016/j.radphyschem.2018.06.015</doi><tpages>4</tpages><orcidid>https://orcid.org/0000-0001-8338-4959</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0969-806X
ispartof Radiation physics and chemistry (Oxford, England : 1993), 2019-02, Vol.155, p.97-100
issn 0969-806X
1879-0895
language eng
recordid cdi_proquest_journals_2162995605
source Access via ScienceDirect (Elsevier)
subjects Calibration
Californium isotopes
Cones
Ionizing radiation
Measurement methods
Monte Carlo simulation
Neutron sources
Neutron spectra
Neutrons
Radiation shielding
Scientific imaging
Spectrometers
title Neutron spectra from Neutron Standards Laboratory (LPN/CIEMAT) sources with two Bonner sphere spectrometers
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T18%3A59%3A09IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Neutron%20spectra%20from%20Neutron%20Standards%20Laboratory%20(LPN/CIEMAT)%20sources%20with%20two%20Bonner%20sphere%20spectrometers&rft.jtitle=Radiation%20physics%20and%20chemistry%20(Oxford,%20England%20:%201993)&rft.au=M%C3%A9ndez-Villafa%C3%B1e,%20R.&rft.date=2019-02&rft.volume=155&rft.spage=97&rft.epage=100&rft.pages=97-100&rft.issn=0969-806X&rft.eissn=1879-0895&rft_id=info:doi/10.1016/j.radphyschem.2018.06.015&rft_dat=%3Cproquest_cross%3E2162995605%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2162995605&rft_id=info:pmid/&rft_els_id=S0969806X17307363&rfr_iscdi=true