Effect of the Wave Structure of the Flow in a Supersonic Combustor on Ignition and Flame Stabilization
Results of numerical and experimental investigations of a high-velocity flow in a plane channel with sudden expansion in the form of a backward-facing step, which is used for flame stabilization in a supersonic flow, are presented. The experiments are performed in the IT-302M high-enthalpy short-dur...
Gespeichert in:
Veröffentlicht in: | Combustion, explosion, and shock waves explosion, and shock waves, 2018-11, Vol.54 (6), p.629-641 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Results of numerical and experimental investigations of a high-velocity flow in a plane channel with sudden expansion in the form of a backward-facing step, which is used for flame stabilization in a supersonic flow, are presented. The experiments are performed in the IT-302M high-enthalpy short-duration wind tunnel under the following test conditions: Mach number at the combustor entrance 2.8, Reynolds number 30 · 10
6
m
−1
, and total temperature
T
0
= 2000 K, i.e., close to flight conditions at M = 6. The numerical simulations are performed by solving full unsteady Reynolds-averaged Navier–Stokes equations supplemented with the
k
–
ω
SST turbulence model and a system of chemical kinetics including 38 forward and backward reactions of combustion of a hydrogen–air mixture. Three configurations of the backward-facing step are considered: straight step without preliminary actions on the flow, with preliminary compression, and with preliminary expansion of the flow. It is demonstrated that the backward-facing step configuration exerts a significant effect on the separation region size, pressure distribution, and temperature in the channel behind the step, which are the parameters determining self-ignition of the mixture. The computed results show that preliminary compression of the flow creates conditions for effective ignition of the mixture. As a result, it is possible to obtain ignition of a premixed hydrogen–air mixture and its stable combustion over the entire channel height. |
---|---|
ISSN: | 0010-5082 1573-8345 |
DOI: | 10.1134/S0010508218060011 |