Reduced acquisition time or activity does for ^sup 123^I-FP-CIT SPECT with compressed sensing-based iterative reconstruction

Objectives: The compressed sensing is a signal processing technique that was initially proposed for spare signal recovery. And it is capable of reconstructing high quality images from a substantially smaller number of views than those needed in filtered back projection (FBP). This study aimed to eva...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of nuclear medicine (1978) 2018-05, Vol.59, p.1805
Hauptverfasser: Matsutomo, Norikazu, Hashimoto, Takeyuki, Yamamoto, Tomoaki
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page 1805
container_title The Journal of nuclear medicine (1978)
container_volume 59
creator Matsutomo, Norikazu
Hashimoto, Takeyuki
Yamamoto, Tomoaki
description Objectives: The compressed sensing is a signal processing technique that was initially proposed for spare signal recovery. And it is capable of reconstructing high quality images from a substantially smaller number of views than those needed in filtered back projection (FBP). This study aimed to evaluate CS-based iterative reconstruction (CS-IR) for 123I-FP-CIT SPECT to reduce image acquisition time or activity dose. Methods: We used the cylinder/sphere and the striatal digital phantom models. The total projection number was set at 120, 90, 60, and 30. In addition, acquired maximum number of photons in a projection was varied from 25 to 100. SPECT images were reconstructed using FBP, Maximum likelihood expectation maximization (MLEM), and CS-IR. The total-variation transform with local image gradient in L1-norm was adopted in our compressed sensing algorithm. The effects of CS-IR were examined according to the resolution recovery factor, activity concentration linearity, percent coefficient of variation (%CV), and specific binding ratio (SBR). Results For the resolution recovery factor and activity concentration linearity, no differences were observed between each reconstruction when decreasing the projection number and counts. Decreasing the projection number and counts, %CV obtained by CS-IR was superior to that obtained by other reconstruction. %CV obtained by 60 projection CS-IR was equivalent to that obtained by 120 projection FBP and MLEM. The variation of SBR was the highest in FBP and SBR obtained by CS-IR was similar to that of MLEM. Conclusions We demonstrated that CS-IR with decreasing the projection number and acquisition count provided a good image quality compared to commonly SPECT reconstruction. Compressed sensing could help to reduce overall SPECT acquisition time or activity does in 123I-FP-CIT SPECT.
format Article
fullrecord <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_journals_2131600087</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2131600087</sourcerecordid><originalsourceid>FETCH-proquest_journals_21316000873</originalsourceid><addsrcrecordid>eNqNTk1rAjEUDKWCW_U_POg5kLgk7n1R6k3aPStr9mmf1GTNS1oK_fGN0B_Q0zAfzMyDqLSpjTTWrh5FpbTV0hhlpuKJ-aKUsk3TVOLnFYfscIDe3TIxJQoeEl0RQixaok9K3zAEZDgVZc95BL2s91u52cl228Hbbt128EXpHVy4jhGZSxujZ_JneezvjBLGvlQhRHTBc4rZ3YfmYnLqPxgXfzgTz5t1177IMYZbRk6HS8jRF-uw1LW25XWzqv-X-gVu7U-9</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2131600087</pqid></control><display><type>article</type><title>Reduced acquisition time or activity does for ^sup 123^I-FP-CIT SPECT with compressed sensing-based iterative reconstruction</title><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>Alma/SFX Local Collection</source><creator>Matsutomo, Norikazu ; Hashimoto, Takeyuki ; Yamamoto, Tomoaki</creator><creatorcontrib>Matsutomo, Norikazu ; Hashimoto, Takeyuki ; Yamamoto, Tomoaki</creatorcontrib><description>Objectives: The compressed sensing is a signal processing technique that was initially proposed for spare signal recovery. And it is capable of reconstructing high quality images from a substantially smaller number of views than those needed in filtered back projection (FBP). This study aimed to evaluate CS-based iterative reconstruction (CS-IR) for 123I-FP-CIT SPECT to reduce image acquisition time or activity dose. Methods: We used the cylinder/sphere and the striatal digital phantom models. The total projection number was set at 120, 90, 60, and 30. In addition, acquired maximum number of photons in a projection was varied from 25 to 100. SPECT images were reconstructed using FBP, Maximum likelihood expectation maximization (MLEM), and CS-IR. The total-variation transform with local image gradient in L1-norm was adopted in our compressed sensing algorithm. The effects of CS-IR were examined according to the resolution recovery factor, activity concentration linearity, percent coefficient of variation (%CV), and specific binding ratio (SBR). Results For the resolution recovery factor and activity concentration linearity, no differences were observed between each reconstruction when decreasing the projection number and counts. Decreasing the projection number and counts, %CV obtained by CS-IR was superior to that obtained by other reconstruction. %CV obtained by 60 projection CS-IR was equivalent to that obtained by 120 projection FBP and MLEM. The variation of SBR was the highest in FBP and SBR obtained by CS-IR was similar to that of MLEM. Conclusions We demonstrated that CS-IR with decreasing the projection number and acquisition count provided a good image quality compared to commonly SPECT reconstruction. Compressed sensing could help to reduce overall SPECT acquisition time or activity does in 123I-FP-CIT SPECT.</description><identifier>ISSN: 0161-5505</identifier><identifier>EISSN: 1535-5667</identifier><language>eng</language><publisher>New York: Society of Nuclear Medicine</publisher><subject>Algorithms ; Coefficient of variation ; Cylinders ; Data processing ; Detection ; Image acquisition ; Image quality ; Image reconstruction ; Iterative methods ; Linearity ; Maximum likelihood method ; Neostriatum ; Photons ; Projection ; Quality control ; Recovery ; Signal processing ; Signal reconstruction ; Single photon emission computed tomography ; Tomography ; Variation</subject><ispartof>The Journal of nuclear medicine (1978), 2018-05, Vol.59, p.1805</ispartof><rights>Copyright Society of Nuclear Medicine May 1, 2018</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780</link.rule.ids></links><search><creatorcontrib>Matsutomo, Norikazu</creatorcontrib><creatorcontrib>Hashimoto, Takeyuki</creatorcontrib><creatorcontrib>Yamamoto, Tomoaki</creatorcontrib><title>Reduced acquisition time or activity does for ^sup 123^I-FP-CIT SPECT with compressed sensing-based iterative reconstruction</title><title>The Journal of nuclear medicine (1978)</title><description>Objectives: The compressed sensing is a signal processing technique that was initially proposed for spare signal recovery. And it is capable of reconstructing high quality images from a substantially smaller number of views than those needed in filtered back projection (FBP). This study aimed to evaluate CS-based iterative reconstruction (CS-IR) for 123I-FP-CIT SPECT to reduce image acquisition time or activity dose. Methods: We used the cylinder/sphere and the striatal digital phantom models. The total projection number was set at 120, 90, 60, and 30. In addition, acquired maximum number of photons in a projection was varied from 25 to 100. SPECT images were reconstructed using FBP, Maximum likelihood expectation maximization (MLEM), and CS-IR. The total-variation transform with local image gradient in L1-norm was adopted in our compressed sensing algorithm. The effects of CS-IR were examined according to the resolution recovery factor, activity concentration linearity, percent coefficient of variation (%CV), and specific binding ratio (SBR). Results For the resolution recovery factor and activity concentration linearity, no differences were observed between each reconstruction when decreasing the projection number and counts. Decreasing the projection number and counts, %CV obtained by CS-IR was superior to that obtained by other reconstruction. %CV obtained by 60 projection CS-IR was equivalent to that obtained by 120 projection FBP and MLEM. The variation of SBR was the highest in FBP and SBR obtained by CS-IR was similar to that of MLEM. Conclusions We demonstrated that CS-IR with decreasing the projection number and acquisition count provided a good image quality compared to commonly SPECT reconstruction. Compressed sensing could help to reduce overall SPECT acquisition time or activity does in 123I-FP-CIT SPECT.</description><subject>Algorithms</subject><subject>Coefficient of variation</subject><subject>Cylinders</subject><subject>Data processing</subject><subject>Detection</subject><subject>Image acquisition</subject><subject>Image quality</subject><subject>Image reconstruction</subject><subject>Iterative methods</subject><subject>Linearity</subject><subject>Maximum likelihood method</subject><subject>Neostriatum</subject><subject>Photons</subject><subject>Projection</subject><subject>Quality control</subject><subject>Recovery</subject><subject>Signal processing</subject><subject>Signal reconstruction</subject><subject>Single photon emission computed tomography</subject><subject>Tomography</subject><subject>Variation</subject><issn>0161-5505</issn><issn>1535-5667</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNqNTk1rAjEUDKWCW_U_POg5kLgk7n1R6k3aPStr9mmf1GTNS1oK_fGN0B_Q0zAfzMyDqLSpjTTWrh5FpbTV0hhlpuKJ-aKUsk3TVOLnFYfscIDe3TIxJQoeEl0RQixaok9K3zAEZDgVZc95BL2s91u52cl228Hbbt128EXpHVy4jhGZSxujZ_JneezvjBLGvlQhRHTBc4rZ3YfmYnLqPxgXfzgTz5t1177IMYZbRk6HS8jRF-uw1LW25XWzqv-X-gVu7U-9</recordid><startdate>20180501</startdate><enddate>20180501</enddate><creator>Matsutomo, Norikazu</creator><creator>Hashimoto, Takeyuki</creator><creator>Yamamoto, Tomoaki</creator><general>Society of Nuclear Medicine</general><scope>4T-</scope><scope>8FD</scope><scope>FR3</scope><scope>K9.</scope><scope>M7Z</scope><scope>NAPCQ</scope><scope>P64</scope></search><sort><creationdate>20180501</creationdate><title>Reduced acquisition time or activity does for ^sup 123^I-FP-CIT SPECT with compressed sensing-based iterative reconstruction</title><author>Matsutomo, Norikazu ; Hashimoto, Takeyuki ; Yamamoto, Tomoaki</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_journals_21316000873</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Algorithms</topic><topic>Coefficient of variation</topic><topic>Cylinders</topic><topic>Data processing</topic><topic>Detection</topic><topic>Image acquisition</topic><topic>Image quality</topic><topic>Image reconstruction</topic><topic>Iterative methods</topic><topic>Linearity</topic><topic>Maximum likelihood method</topic><topic>Neostriatum</topic><topic>Photons</topic><topic>Projection</topic><topic>Quality control</topic><topic>Recovery</topic><topic>Signal processing</topic><topic>Signal reconstruction</topic><topic>Single photon emission computed tomography</topic><topic>Tomography</topic><topic>Variation</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Matsutomo, Norikazu</creatorcontrib><creatorcontrib>Hashimoto, Takeyuki</creatorcontrib><creatorcontrib>Yamamoto, Tomoaki</creatorcontrib><collection>Docstoc</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Biochemistry Abstracts 1</collection><collection>Nursing &amp; Allied Health Premium</collection><collection>Biotechnology and BioEngineering Abstracts</collection><jtitle>The Journal of nuclear medicine (1978)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Matsutomo, Norikazu</au><au>Hashimoto, Takeyuki</au><au>Yamamoto, Tomoaki</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Reduced acquisition time or activity does for ^sup 123^I-FP-CIT SPECT with compressed sensing-based iterative reconstruction</atitle><jtitle>The Journal of nuclear medicine (1978)</jtitle><date>2018-05-01</date><risdate>2018</risdate><volume>59</volume><spage>1805</spage><pages>1805-</pages><issn>0161-5505</issn><eissn>1535-5667</eissn><abstract>Objectives: The compressed sensing is a signal processing technique that was initially proposed for spare signal recovery. And it is capable of reconstructing high quality images from a substantially smaller number of views than those needed in filtered back projection (FBP). This study aimed to evaluate CS-based iterative reconstruction (CS-IR) for 123I-FP-CIT SPECT to reduce image acquisition time or activity dose. Methods: We used the cylinder/sphere and the striatal digital phantom models. The total projection number was set at 120, 90, 60, and 30. In addition, acquired maximum number of photons in a projection was varied from 25 to 100. SPECT images were reconstructed using FBP, Maximum likelihood expectation maximization (MLEM), and CS-IR. The total-variation transform with local image gradient in L1-norm was adopted in our compressed sensing algorithm. The effects of CS-IR were examined according to the resolution recovery factor, activity concentration linearity, percent coefficient of variation (%CV), and specific binding ratio (SBR). Results For the resolution recovery factor and activity concentration linearity, no differences were observed between each reconstruction when decreasing the projection number and counts. Decreasing the projection number and counts, %CV obtained by CS-IR was superior to that obtained by other reconstruction. %CV obtained by 60 projection CS-IR was equivalent to that obtained by 120 projection FBP and MLEM. The variation of SBR was the highest in FBP and SBR obtained by CS-IR was similar to that of MLEM. Conclusions We demonstrated that CS-IR with decreasing the projection number and acquisition count provided a good image quality compared to commonly SPECT reconstruction. Compressed sensing could help to reduce overall SPECT acquisition time or activity does in 123I-FP-CIT SPECT.</abstract><cop>New York</cop><pub>Society of Nuclear Medicine</pub></addata></record>
fulltext fulltext
identifier ISSN: 0161-5505
ispartof The Journal of nuclear medicine (1978), 2018-05, Vol.59, p.1805
issn 0161-5505
1535-5667
language eng
recordid cdi_proquest_journals_2131600087
source Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; Alma/SFX Local Collection
subjects Algorithms
Coefficient of variation
Cylinders
Data processing
Detection
Image acquisition
Image quality
Image reconstruction
Iterative methods
Linearity
Maximum likelihood method
Neostriatum
Photons
Projection
Quality control
Recovery
Signal processing
Signal reconstruction
Single photon emission computed tomography
Tomography
Variation
title Reduced acquisition time or activity does for ^sup 123^I-FP-CIT SPECT with compressed sensing-based iterative reconstruction
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-10T07%3A18%3A35IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Reduced%20acquisition%20time%20or%20activity%20does%20for%20%5Esup%20123%5EI-FP-CIT%20SPECT%20with%20compressed%20sensing-based%20iterative%20reconstruction&rft.jtitle=The%20Journal%20of%20nuclear%20medicine%20(1978)&rft.au=Matsutomo,%20Norikazu&rft.date=2018-05-01&rft.volume=59&rft.spage=1805&rft.pages=1805-&rft.issn=0161-5505&rft.eissn=1535-5667&rft_id=info:doi/&rft_dat=%3Cproquest%3E2131600087%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2131600087&rft_id=info:pmid/&rfr_iscdi=true