Assessment of a guideline-based heart substructures delineation in left-sided breast cancer patients undergoing adjuvant radiotherapy

Background and purposeIn our institute, breast cancer patients undergoing adjuvant treatment are included in a protocol aimed to reduce cardiovascular morbidity (SAFE-2014, NCT2236806), assessing preclinical heart damage with heart speckle-tracking ultrasound. To develop a dose constraint related to...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Strahlentherapie und Onkologie 2019-01, Vol.195 (1), p.43-51
Hauptverfasser: Francolini, Giulio, Desideri, Isacco, Meattini, Icro, Becherini, Carlotta, Terziani, Francesca, Olmetto, Emanuela, Camilla Delli Paoli, Donato Pezzulla, Loi, Mauro, Bonomo, Pierluigi, Greto, Daniela, Calusi, Silvia, Casati, Marta, Pallotta, Stefania, Livi, Lorenzo
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 51
container_issue 1
container_start_page 43
container_title Strahlentherapie und Onkologie
container_volume 195
creator Francolini, Giulio
Desideri, Isacco
Meattini, Icro
Becherini, Carlotta
Terziani, Francesca
Olmetto, Emanuela
Camilla Delli Paoli
Donato Pezzulla
Loi, Mauro
Bonomo, Pierluigi
Greto, Daniela
Calusi, Silvia
Casati, Marta
Pallotta, Stefania
Livi, Lorenzo
description Background and purposeIn our institute, breast cancer patients undergoing adjuvant treatment are included in a protocol aimed to reduce cardiovascular morbidity (SAFE-2014, NCT2236806), assessing preclinical heart damage with heart speckle-tracking ultrasound. To develop a dose constraint related to subclinical heart damage, a reliable delineation of heart substructures based on a pre-existing guideline was made.Patients and methodsHeart substructures of 16 left-sided breast cancer patients included in the SAFE protocol were delineated by five operators. For each substructure, a multi-contour delineation based on a majority vote algorithm (MCD) was created. A consensus-based delineation (CBD) was developed by an independent team of two blinded operators. Dice similarity coefficients (DSC) between volumes delineated by different operators and the MCD were collected and reported, as well as DSC between CBD and MCD.ResultsMean DSCs between heart chambers delineated by each operator and the corresponding MCDs ranged between 0.78 and 0.96. Mean DSC between substructures delineated by all single operators and the corresponding MCD ranged between 0.84 and 0.94. Mean DSC between CBD and the corresponding MCD ranged from 0.89 to 0.97.ConclusionResults showed low inter-observer variability of heart substructure delineation. This constitutes an external validation of the contouring atlas used, allowing a reliable dosimetric assessment of these volumes within the SAFE-2014 trial.
doi_str_mv 10.1007/s00066-018-1388-x
format Article
fullrecord <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_journals_2130629697</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2130629697</sourcerecordid><originalsourceid>FETCH-LOGICAL-c767-f61556a085527261aae9b91a7b91d345e0d49965cb9ba4071edfafaf5434733</originalsourceid><addsrcrecordid>eNotjc1KAzEUhYMoWKsP4C7gOppM_ibLUvyDgiAu3JU7kzvtlJqpuRnRB_C9HagcOGfznXMYu1byVknp70hK6ZyQqhZK17X4PmEzZXQQMoT3UzaTygfhla3P2QXRTkrlTDAz9rsgQqIPTIUPHQe-GfuI-z6haIAw8i1CLpzGhkoe2zJmJH4EoPRD4n3ie-yKoKkWeZMRqPAWUouZHyZkGiY-poh5M_RpwyHuxi-Y3jLEfihbzHD4uWRnHewJr_5zzl4f7t-WT2L18vi8XKxE650XnVPWOpC1tZWvnALA0AQFfrKojUUZTQjOtk1owEivMHYwyRptvNZzdnMcPeThc0Qq690w5jT9rSulpauCC17_Afx2Zdo</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2130629697</pqid></control><display><type>article</type><title>Assessment of a guideline-based heart substructures delineation in left-sided breast cancer patients undergoing adjuvant radiotherapy</title><source>Springer Nature - Complete Springer Journals</source><creator>Francolini, Giulio ; Desideri, Isacco ; Meattini, Icro ; Becherini, Carlotta ; Terziani, Francesca ; Olmetto, Emanuela ; Camilla Delli Paoli ; Donato Pezzulla ; Loi, Mauro ; Bonomo, Pierluigi ; Greto, Daniela ; Calusi, Silvia ; Casati, Marta ; Pallotta, Stefania ; Livi, Lorenzo</creator><creatorcontrib>Francolini, Giulio ; Desideri, Isacco ; Meattini, Icro ; Becherini, Carlotta ; Terziani, Francesca ; Olmetto, Emanuela ; Camilla Delli Paoli ; Donato Pezzulla ; Loi, Mauro ; Bonomo, Pierluigi ; Greto, Daniela ; Calusi, Silvia ; Casati, Marta ; Pallotta, Stefania ; Livi, Lorenzo</creatorcontrib><description>Background and purposeIn our institute, breast cancer patients undergoing adjuvant treatment are included in a protocol aimed to reduce cardiovascular morbidity (SAFE-2014, NCT2236806), assessing preclinical heart damage with heart speckle-tracking ultrasound. To develop a dose constraint related to subclinical heart damage, a reliable delineation of heart substructures based on a pre-existing guideline was made.Patients and methodsHeart substructures of 16 left-sided breast cancer patients included in the SAFE protocol were delineated by five operators. For each substructure, a multi-contour delineation based on a majority vote algorithm (MCD) was created. A consensus-based delineation (CBD) was developed by an independent team of two blinded operators. Dice similarity coefficients (DSC) between volumes delineated by different operators and the MCD were collected and reported, as well as DSC between CBD and MCD.ResultsMean DSCs between heart chambers delineated by each operator and the corresponding MCDs ranged between 0.78 and 0.96. Mean DSC between substructures delineated by all single operators and the corresponding MCD ranged between 0.84 and 0.94. Mean DSC between CBD and the corresponding MCD ranged from 0.89 to 0.97.ConclusionResults showed low inter-observer variability of heart substructure delineation. This constitutes an external validation of the contouring atlas used, allowing a reliable dosimetric assessment of these volumes within the SAFE-2014 trial.</description><identifier>ISSN: 0179-7158</identifier><identifier>EISSN: 1439-099X</identifier><identifier>DOI: 10.1007/s00066-018-1388-x</identifier><language>eng</language><publisher>Heidelberg: Springer Nature B.V</publisher><subject>Algorithms ; Breast cancer ; Cancer ; Contouring ; Damage assessment ; Delineation ; Health risk assessment ; Heart ; Immunotherapy ; Monoclonal antibodies ; Operators ; Patients ; Radiation therapy ; Similarity ; Substructures ; Targeted cancer therapy ; Tracking</subject><ispartof>Strahlentherapie und Onkologie, 2019-01, Vol.195 (1), p.43-51</ispartof><rights>Strahlentherapie und Onkologie is a copyright of Springer, (2018). All Rights Reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c767-f61556a085527261aae9b91a7b91d345e0d49965cb9ba4071edfafaf5434733</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27903,27904</link.rule.ids></links><search><creatorcontrib>Francolini, Giulio</creatorcontrib><creatorcontrib>Desideri, Isacco</creatorcontrib><creatorcontrib>Meattini, Icro</creatorcontrib><creatorcontrib>Becherini, Carlotta</creatorcontrib><creatorcontrib>Terziani, Francesca</creatorcontrib><creatorcontrib>Olmetto, Emanuela</creatorcontrib><creatorcontrib>Camilla Delli Paoli</creatorcontrib><creatorcontrib>Donato Pezzulla</creatorcontrib><creatorcontrib>Loi, Mauro</creatorcontrib><creatorcontrib>Bonomo, Pierluigi</creatorcontrib><creatorcontrib>Greto, Daniela</creatorcontrib><creatorcontrib>Calusi, Silvia</creatorcontrib><creatorcontrib>Casati, Marta</creatorcontrib><creatorcontrib>Pallotta, Stefania</creatorcontrib><creatorcontrib>Livi, Lorenzo</creatorcontrib><title>Assessment of a guideline-based heart substructures delineation in left-sided breast cancer patients undergoing adjuvant radiotherapy</title><title>Strahlentherapie und Onkologie</title><description>Background and purposeIn our institute, breast cancer patients undergoing adjuvant treatment are included in a protocol aimed to reduce cardiovascular morbidity (SAFE-2014, NCT2236806), assessing preclinical heart damage with heart speckle-tracking ultrasound. To develop a dose constraint related to subclinical heart damage, a reliable delineation of heart substructures based on a pre-existing guideline was made.Patients and methodsHeart substructures of 16 left-sided breast cancer patients included in the SAFE protocol were delineated by five operators. For each substructure, a multi-contour delineation based on a majority vote algorithm (MCD) was created. A consensus-based delineation (CBD) was developed by an independent team of two blinded operators. Dice similarity coefficients (DSC) between volumes delineated by different operators and the MCD were collected and reported, as well as DSC between CBD and MCD.ResultsMean DSCs between heart chambers delineated by each operator and the corresponding MCDs ranged between 0.78 and 0.96. Mean DSC between substructures delineated by all single operators and the corresponding MCD ranged between 0.84 and 0.94. Mean DSC between CBD and the corresponding MCD ranged from 0.89 to 0.97.ConclusionResults showed low inter-observer variability of heart substructure delineation. This constitutes an external validation of the contouring atlas used, allowing a reliable dosimetric assessment of these volumes within the SAFE-2014 trial.</description><subject>Algorithms</subject><subject>Breast cancer</subject><subject>Cancer</subject><subject>Contouring</subject><subject>Damage assessment</subject><subject>Delineation</subject><subject>Health risk assessment</subject><subject>Heart</subject><subject>Immunotherapy</subject><subject>Monoclonal antibodies</subject><subject>Operators</subject><subject>Patients</subject><subject>Radiation therapy</subject><subject>Similarity</subject><subject>Substructures</subject><subject>Targeted cancer therapy</subject><subject>Tracking</subject><issn>0179-7158</issn><issn>1439-099X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><recordid>eNotjc1KAzEUhYMoWKsP4C7gOppM_ibLUvyDgiAu3JU7kzvtlJqpuRnRB_C9HagcOGfznXMYu1byVknp70hK6ZyQqhZK17X4PmEzZXQQMoT3UzaTygfhla3P2QXRTkrlTDAz9rsgQqIPTIUPHQe-GfuI-z6haIAw8i1CLpzGhkoe2zJmJH4EoPRD4n3ie-yKoKkWeZMRqPAWUouZHyZkGiY-poh5M_RpwyHuxi-Y3jLEfihbzHD4uWRnHewJr_5zzl4f7t-WT2L18vi8XKxE650XnVPWOpC1tZWvnALA0AQFfrKojUUZTQjOtk1owEivMHYwyRptvNZzdnMcPeThc0Qq690w5jT9rSulpauCC17_Afx2Zdo</recordid><startdate>20190101</startdate><enddate>20190101</enddate><creator>Francolini, Giulio</creator><creator>Desideri, Isacco</creator><creator>Meattini, Icro</creator><creator>Becherini, Carlotta</creator><creator>Terziani, Francesca</creator><creator>Olmetto, Emanuela</creator><creator>Camilla Delli Paoli</creator><creator>Donato Pezzulla</creator><creator>Loi, Mauro</creator><creator>Bonomo, Pierluigi</creator><creator>Greto, Daniela</creator><creator>Calusi, Silvia</creator><creator>Casati, Marta</creator><creator>Pallotta, Stefania</creator><creator>Livi, Lorenzo</creator><general>Springer Nature B.V</general><scope>3V.</scope><scope>7RV</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>8AO</scope><scope>8C1</scope><scope>8FE</scope><scope>8FG</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>ARAPS</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>HCIFZ</scope><scope>K9.</scope><scope>KB0</scope><scope>M0S</scope><scope>M1P</scope><scope>NAPCQ</scope><scope>P5Z</scope><scope>P62</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope></search><sort><creationdate>20190101</creationdate><title>Assessment of a guideline-based heart substructures delineation in left-sided breast cancer patients undergoing adjuvant radiotherapy</title><author>Francolini, Giulio ; Desideri, Isacco ; Meattini, Icro ; Becherini, Carlotta ; Terziani, Francesca ; Olmetto, Emanuela ; Camilla Delli Paoli ; Donato Pezzulla ; Loi, Mauro ; Bonomo, Pierluigi ; Greto, Daniela ; Calusi, Silvia ; Casati, Marta ; Pallotta, Stefania ; Livi, Lorenzo</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c767-f61556a085527261aae9b91a7b91d345e0d49965cb9ba4071edfafaf5434733</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Algorithms</topic><topic>Breast cancer</topic><topic>Cancer</topic><topic>Contouring</topic><topic>Damage assessment</topic><topic>Delineation</topic><topic>Health risk assessment</topic><topic>Heart</topic><topic>Immunotherapy</topic><topic>Monoclonal antibodies</topic><topic>Operators</topic><topic>Patients</topic><topic>Radiation therapy</topic><topic>Similarity</topic><topic>Substructures</topic><topic>Targeted cancer therapy</topic><topic>Tracking</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Francolini, Giulio</creatorcontrib><creatorcontrib>Desideri, Isacco</creatorcontrib><creatorcontrib>Meattini, Icro</creatorcontrib><creatorcontrib>Becherini, Carlotta</creatorcontrib><creatorcontrib>Terziani, Francesca</creatorcontrib><creatorcontrib>Olmetto, Emanuela</creatorcontrib><creatorcontrib>Camilla Delli Paoli</creatorcontrib><creatorcontrib>Donato Pezzulla</creatorcontrib><creatorcontrib>Loi, Mauro</creatorcontrib><creatorcontrib>Bonomo, Pierluigi</creatorcontrib><creatorcontrib>Greto, Daniela</creatorcontrib><creatorcontrib>Calusi, Silvia</creatorcontrib><creatorcontrib>Casati, Marta</creatorcontrib><creatorcontrib>Pallotta, Stefania</creatorcontrib><creatorcontrib>Livi, Lorenzo</creatorcontrib><collection>ProQuest Central (Corporate)</collection><collection>Nursing &amp; Allied Health Database</collection><collection>Health &amp; Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>ProQuest Pharma Collection</collection><collection>Public Health Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>Advanced Technologies &amp; Aerospace Collection</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Nursing &amp; Allied Health Database (Alumni Edition)</collection><collection>Health &amp; Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>Nursing &amp; Allied Health Premium</collection><collection>Advanced Technologies &amp; Aerospace Database</collection><collection>ProQuest Advanced Technologies &amp; Aerospace Collection</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><jtitle>Strahlentherapie und Onkologie</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Francolini, Giulio</au><au>Desideri, Isacco</au><au>Meattini, Icro</au><au>Becherini, Carlotta</au><au>Terziani, Francesca</au><au>Olmetto, Emanuela</au><au>Camilla Delli Paoli</au><au>Donato Pezzulla</au><au>Loi, Mauro</au><au>Bonomo, Pierluigi</au><au>Greto, Daniela</au><au>Calusi, Silvia</au><au>Casati, Marta</au><au>Pallotta, Stefania</au><au>Livi, Lorenzo</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Assessment of a guideline-based heart substructures delineation in left-sided breast cancer patients undergoing adjuvant radiotherapy</atitle><jtitle>Strahlentherapie und Onkologie</jtitle><date>2019-01-01</date><risdate>2019</risdate><volume>195</volume><issue>1</issue><spage>43</spage><epage>51</epage><pages>43-51</pages><issn>0179-7158</issn><eissn>1439-099X</eissn><abstract>Background and purposeIn our institute, breast cancer patients undergoing adjuvant treatment are included in a protocol aimed to reduce cardiovascular morbidity (SAFE-2014, NCT2236806), assessing preclinical heart damage with heart speckle-tracking ultrasound. To develop a dose constraint related to subclinical heart damage, a reliable delineation of heart substructures based on a pre-existing guideline was made.Patients and methodsHeart substructures of 16 left-sided breast cancer patients included in the SAFE protocol were delineated by five operators. For each substructure, a multi-contour delineation based on a majority vote algorithm (MCD) was created. A consensus-based delineation (CBD) was developed by an independent team of two blinded operators. Dice similarity coefficients (DSC) between volumes delineated by different operators and the MCD were collected and reported, as well as DSC between CBD and MCD.ResultsMean DSCs between heart chambers delineated by each operator and the corresponding MCDs ranged between 0.78 and 0.96. Mean DSC between substructures delineated by all single operators and the corresponding MCD ranged between 0.84 and 0.94. Mean DSC between CBD and the corresponding MCD ranged from 0.89 to 0.97.ConclusionResults showed low inter-observer variability of heart substructure delineation. This constitutes an external validation of the contouring atlas used, allowing a reliable dosimetric assessment of these volumes within the SAFE-2014 trial.</abstract><cop>Heidelberg</cop><pub>Springer Nature B.V</pub><doi>10.1007/s00066-018-1388-x</doi><tpages>9</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0179-7158
ispartof Strahlentherapie und Onkologie, 2019-01, Vol.195 (1), p.43-51
issn 0179-7158
1439-099X
language eng
recordid cdi_proquest_journals_2130629697
source Springer Nature - Complete Springer Journals
subjects Algorithms
Breast cancer
Cancer
Contouring
Damage assessment
Delineation
Health risk assessment
Heart
Immunotherapy
Monoclonal antibodies
Operators
Patients
Radiation therapy
Similarity
Substructures
Targeted cancer therapy
Tracking
title Assessment of a guideline-based heart substructures delineation in left-sided breast cancer patients undergoing adjuvant radiotherapy
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-25T15%3A48%3A14IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Assessment%20of%20a%20guideline-based%20heart%20substructures%20delineation%20in%20left-sided%20breast%20cancer%20patients%20undergoing%20adjuvant%20radiotherapy&rft.jtitle=Strahlentherapie%20und%20Onkologie&rft.au=Francolini,%20Giulio&rft.date=2019-01-01&rft.volume=195&rft.issue=1&rft.spage=43&rft.epage=51&rft.pages=43-51&rft.issn=0179-7158&rft.eissn=1439-099X&rft_id=info:doi/10.1007/s00066-018-1388-x&rft_dat=%3Cproquest%3E2130629697%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2130629697&rft_id=info:pmid/&rfr_iscdi=true