Blunt traumatic great saphenous vein pseudoaneurysm
Traumatic venous pseudoaneurysm is extremely rare. Only two cases of great saphenous venous (GSV) pseudoaneurysm have been reported. We present a case in which a gradually enlarged mass occurred at the calf after local injury. It was nonpulsatile and varied in size with posture. It was initially mis...
Gespeichert in:
Veröffentlicht in: | Journal of clinical ultrasound 2018-11, Vol.46 (9), p.602-604 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 604 |
---|---|
container_issue | 9 |
container_start_page | 602 |
container_title | Journal of clinical ultrasound |
container_volume | 46 |
creator | Fu, Yiyi Fu, Yuangen Lai, Yuqiong |
description | Traumatic venous pseudoaneurysm is extremely rare. Only two cases of great saphenous venous (GSV) pseudoaneurysm have been reported. We present a case in which a gradually enlarged mass occurred at the calf after local injury. It was nonpulsatile and varied in size with posture. It was initially misdiagnosed by contrast MRI. Duplex ultrasound and surgical intervention eventually identified it as a GSV pseudoaneurysm. This case demonstrates the need for physicians to consider venous pseudoaneurysm as a possible diagnosis for nonpulsatile masses in patient with traumatic history, and to use Duplex ultrasound for adequate evaluation. |
doi_str_mv | 10.1002/jcu.22605 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2129382189</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2129382189</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3205-9126479041adf57c301bc098f3c3e97aaaae75eefbb3b56dec62f57870dfb75d3</originalsourceid><addsrcrecordid>eNp1kL1OwzAURi0EoqUw8AIoEhND2mu7juMRKn5ViYXOluPcQKomKXYM6ttjSGHjLt9ydK50CDmnMKUAbLa2YcpYBuKAjCkomQKo7JCM49CUSUFH5MT7NQBkQohjMmJKziFnckz4zSa0fdI7ExrT1zZ5dWj6xJvtG7Zd8MkH1m2y9RjKzrQY3M43p-SoMhuPZ_udkNXd7cviIV0-3z8urpep5QxEqijL5lLBnJqyEtJyoIUFlVfcclTSxEMpEKui4IXISrQZi1wuoawKKUo-IZeDd-u694C-1-suuDa-1IwyxXNGcxWpq4GyrvPeYaW3rm6M22kK-juPjnn0T57IXuyNoWiw_CN_e0RgNgCf9QZ3_5v002I1KL8AcUxujg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2129382189</pqid></control><display><type>article</type><title>Blunt traumatic great saphenous vein pseudoaneurysm</title><source>MEDLINE</source><source>Access via Wiley Online Library</source><creator>Fu, Yiyi ; Fu, Yuangen ; Lai, Yuqiong</creator><creatorcontrib>Fu, Yiyi ; Fu, Yuangen ; Lai, Yuqiong</creatorcontrib><description>Traumatic venous pseudoaneurysm is extremely rare. Only two cases of great saphenous venous (GSV) pseudoaneurysm have been reported. We present a case in which a gradually enlarged mass occurred at the calf after local injury. It was nonpulsatile and varied in size with posture. It was initially misdiagnosed by contrast MRI. Duplex ultrasound and surgical intervention eventually identified it as a GSV pseudoaneurysm. This case demonstrates the need for physicians to consider venous pseudoaneurysm as a possible diagnosis for nonpulsatile masses in patient with traumatic history, and to use Duplex ultrasound for adequate evaluation.</description><identifier>ISSN: 0091-2751</identifier><identifier>EISSN: 1097-0096</identifier><identifier>DOI: 10.1002/jcu.22605</identifier><identifier>PMID: 29740827</identifier><language>eng</language><publisher>United States: Wiley Subscription Services, Inc</publisher><subject>Adult ; Aneurysm, False - diagnostic imaging ; Aneurysm, False - etiology ; Aneurysm, False - surgery ; great saphenous vein ; Humans ; Leg - surgery ; Leg Injuries - diagnostic imaging ; Leg Injuries - surgery ; Magnetic resonance imaging ; Male ; Medical personnel ; Physicians ; Posture ; Pseudoaneurysm ; Saphenous Vein - diagnostic imaging ; Saphenous Vein - injuries ; Saphenous Vein - surgery ; Surgery ; trauma ; Ultrasonic imaging ; Ultrasonography, Doppler, Duplex - methods ; Ultrasound ; Wounds, Nonpenetrating - complications ; Wounds, Nonpenetrating - diagnostic imaging</subject><ispartof>Journal of clinical ultrasound, 2018-11, Vol.46 (9), p.602-604</ispartof><rights>2018 Wiley Periodicals, Inc.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3205-9126479041adf57c301bc098f3c3e97aaaae75eefbb3b56dec62f57870dfb75d3</citedby><cites>FETCH-LOGICAL-c3205-9126479041adf57c301bc098f3c3e97aaaae75eefbb3b56dec62f57870dfb75d3</cites><orcidid>0000-0002-5492-890X</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Fjcu.22605$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Fjcu.22605$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>315,781,785,1418,27925,27926,45575,45576</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/29740827$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Fu, Yiyi</creatorcontrib><creatorcontrib>Fu, Yuangen</creatorcontrib><creatorcontrib>Lai, Yuqiong</creatorcontrib><title>Blunt traumatic great saphenous vein pseudoaneurysm</title><title>Journal of clinical ultrasound</title><addtitle>J Clin Ultrasound</addtitle><description>Traumatic venous pseudoaneurysm is extremely rare. Only two cases of great saphenous venous (GSV) pseudoaneurysm have been reported. We present a case in which a gradually enlarged mass occurred at the calf after local injury. It was nonpulsatile and varied in size with posture. It was initially misdiagnosed by contrast MRI. Duplex ultrasound and surgical intervention eventually identified it as a GSV pseudoaneurysm. This case demonstrates the need for physicians to consider venous pseudoaneurysm as a possible diagnosis for nonpulsatile masses in patient with traumatic history, and to use Duplex ultrasound for adequate evaluation.</description><subject>Adult</subject><subject>Aneurysm, False - diagnostic imaging</subject><subject>Aneurysm, False - etiology</subject><subject>Aneurysm, False - surgery</subject><subject>great saphenous vein</subject><subject>Humans</subject><subject>Leg - surgery</subject><subject>Leg Injuries - diagnostic imaging</subject><subject>Leg Injuries - surgery</subject><subject>Magnetic resonance imaging</subject><subject>Male</subject><subject>Medical personnel</subject><subject>Physicians</subject><subject>Posture</subject><subject>Pseudoaneurysm</subject><subject>Saphenous Vein - diagnostic imaging</subject><subject>Saphenous Vein - injuries</subject><subject>Saphenous Vein - surgery</subject><subject>Surgery</subject><subject>trauma</subject><subject>Ultrasonic imaging</subject><subject>Ultrasonography, Doppler, Duplex - methods</subject><subject>Ultrasound</subject><subject>Wounds, Nonpenetrating - complications</subject><subject>Wounds, Nonpenetrating - diagnostic imaging</subject><issn>0091-2751</issn><issn>1097-0096</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp1kL1OwzAURi0EoqUw8AIoEhND2mu7juMRKn5ViYXOluPcQKomKXYM6ttjSGHjLt9ydK50CDmnMKUAbLa2YcpYBuKAjCkomQKo7JCM49CUSUFH5MT7NQBkQohjMmJKziFnckz4zSa0fdI7ExrT1zZ5dWj6xJvtG7Zd8MkH1m2y9RjKzrQY3M43p-SoMhuPZ_udkNXd7cviIV0-3z8urpep5QxEqijL5lLBnJqyEtJyoIUFlVfcclTSxEMpEKui4IXISrQZi1wuoawKKUo-IZeDd-u694C-1-suuDa-1IwyxXNGcxWpq4GyrvPeYaW3rm6M22kK-juPjnn0T57IXuyNoWiw_CN_e0RgNgCf9QZ3_5v002I1KL8AcUxujg</recordid><startdate>201811</startdate><enddate>201811</enddate><creator>Fu, Yiyi</creator><creator>Fu, Yuangen</creator><creator>Lai, Yuqiong</creator><general>Wiley Subscription Services, Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>8FD</scope><scope>FR3</scope><scope>K9.</scope><scope>M7Z</scope><scope>P64</scope><orcidid>https://orcid.org/0000-0002-5492-890X</orcidid></search><sort><creationdate>201811</creationdate><title>Blunt traumatic great saphenous vein pseudoaneurysm</title><author>Fu, Yiyi ; Fu, Yuangen ; Lai, Yuqiong</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3205-9126479041adf57c301bc098f3c3e97aaaae75eefbb3b56dec62f57870dfb75d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Adult</topic><topic>Aneurysm, False - diagnostic imaging</topic><topic>Aneurysm, False - etiology</topic><topic>Aneurysm, False - surgery</topic><topic>great saphenous vein</topic><topic>Humans</topic><topic>Leg - surgery</topic><topic>Leg Injuries - diagnostic imaging</topic><topic>Leg Injuries - surgery</topic><topic>Magnetic resonance imaging</topic><topic>Male</topic><topic>Medical personnel</topic><topic>Physicians</topic><topic>Posture</topic><topic>Pseudoaneurysm</topic><topic>Saphenous Vein - diagnostic imaging</topic><topic>Saphenous Vein - injuries</topic><topic>Saphenous Vein - surgery</topic><topic>Surgery</topic><topic>trauma</topic><topic>Ultrasonic imaging</topic><topic>Ultrasonography, Doppler, Duplex - methods</topic><topic>Ultrasound</topic><topic>Wounds, Nonpenetrating - complications</topic><topic>Wounds, Nonpenetrating - diagnostic imaging</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Fu, Yiyi</creatorcontrib><creatorcontrib>Fu, Yuangen</creatorcontrib><creatorcontrib>Lai, Yuqiong</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>Biochemistry Abstracts 1</collection><collection>Biotechnology and BioEngineering Abstracts</collection><jtitle>Journal of clinical ultrasound</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Fu, Yiyi</au><au>Fu, Yuangen</au><au>Lai, Yuqiong</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Blunt traumatic great saphenous vein pseudoaneurysm</atitle><jtitle>Journal of clinical ultrasound</jtitle><addtitle>J Clin Ultrasound</addtitle><date>2018-11</date><risdate>2018</risdate><volume>46</volume><issue>9</issue><spage>602</spage><epage>604</epage><pages>602-604</pages><issn>0091-2751</issn><eissn>1097-0096</eissn><abstract>Traumatic venous pseudoaneurysm is extremely rare. Only two cases of great saphenous venous (GSV) pseudoaneurysm have been reported. We present a case in which a gradually enlarged mass occurred at the calf after local injury. It was nonpulsatile and varied in size with posture. It was initially misdiagnosed by contrast MRI. Duplex ultrasound and surgical intervention eventually identified it as a GSV pseudoaneurysm. This case demonstrates the need for physicians to consider venous pseudoaneurysm as a possible diagnosis for nonpulsatile masses in patient with traumatic history, and to use Duplex ultrasound for adequate evaluation.</abstract><cop>United States</cop><pub>Wiley Subscription Services, Inc</pub><pmid>29740827</pmid><doi>10.1002/jcu.22605</doi><tpages>3</tpages><orcidid>https://orcid.org/0000-0002-5492-890X</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0091-2751 |
ispartof | Journal of clinical ultrasound, 2018-11, Vol.46 (9), p.602-604 |
issn | 0091-2751 1097-0096 |
language | eng |
recordid | cdi_proquest_journals_2129382189 |
source | MEDLINE; Access via Wiley Online Library |
subjects | Adult Aneurysm, False - diagnostic imaging Aneurysm, False - etiology Aneurysm, False - surgery great saphenous vein Humans Leg - surgery Leg Injuries - diagnostic imaging Leg Injuries - surgery Magnetic resonance imaging Male Medical personnel Physicians Posture Pseudoaneurysm Saphenous Vein - diagnostic imaging Saphenous Vein - injuries Saphenous Vein - surgery Surgery trauma Ultrasonic imaging Ultrasonography, Doppler, Duplex - methods Ultrasound Wounds, Nonpenetrating - complications Wounds, Nonpenetrating - diagnostic imaging |
title | Blunt traumatic great saphenous vein pseudoaneurysm |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-18T13%3A28%3A01IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Blunt%20traumatic%20great%20saphenous%20vein%20pseudoaneurysm&rft.jtitle=Journal%20of%20clinical%20ultrasound&rft.au=Fu,%20Yiyi&rft.date=2018-11&rft.volume=46&rft.issue=9&rft.spage=602&rft.epage=604&rft.pages=602-604&rft.issn=0091-2751&rft.eissn=1097-0096&rft_id=info:doi/10.1002/jcu.22605&rft_dat=%3Cproquest_cross%3E2129382189%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2129382189&rft_id=info:pmid/29740827&rfr_iscdi=true |