Reduction of radiation exposure while maintaining high-quality fluoroscopic images during interventional cardiology using novel X-ray tube technology with extra beam filtering

Radiographic technology plays an integral role in interventional cardiology. The number of interventions continues to increase, and the associated radiation exposure to patients and personnel is of major concern. This study was undertaken to determine whether a newly developed x-ray tube deploying g...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Circulation (New York, N.Y.) N.Y.), 1994-06, Vol.89 (6), p.2710-2714
Hauptverfasser: AD DEN BOER, DE FEYTER, P. J, HUMMEL, W. A, KEANE, D, ROELANDT, J. R. T. C
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 2714
container_issue 6
container_start_page 2710
container_title Circulation (New York, N.Y.)
container_volume 89
creator AD DEN BOER
DE FEYTER, P. J
HUMMEL, W. A
KEANE, D
ROELANDT, J. R. T. C
description Radiographic technology plays an integral role in interventional cardiology. The number of interventions continues to increase, and the associated radiation exposure to patients and personnel is of major concern. This study was undertaken to determine whether a newly developed x-ray tube deploying grid-switched pulsed fluoroscopy and extra beam filtering can achieve a reduction in radiation exposure while maintaining fluoroscopic images of high quality. Three fluoroscopic techniques were compared: continuous fluoroscopy, pulsed fluoroscopy, and a newly developed high-output pulsed fluoroscopy with extra filtering. To ascertain differences in the quality of images and to determine differences in patient entrance and investigator radiation exposure, the radiated volume curve was measured to determine the required high voltage levels (kVpeak) for different object sizes for each fluoroscopic mode. The fluoroscopic data of 124 patient procedures were combined. The data were analyzed for radiographic projections, image intensifier field size, and x-ray tube kilovoltage levels (kVpeak). On the basis of this analysis, a reference procedure was constructed. The reference procedure was tested on a phantom or dummy patient by all three fluoroscopic modes. The phantom was so designed that the kilovoltage requirements for each projection were comparable to those needed for the average patient. Radiation exposure of the operator and patient was measured during each mode. The patient entrance dose was measured in air, and the operator dose was measured by 18 dosimeters on a dummy operator. Pulsed compared with continuous fluoroscopy could be performed with improved image quality at lower kilovoltages. The patient entrance dose was reduced by 21% and the operator dose by 54%. High-output pulsed fluoroscopy with extra beam filtering compared with continuous fluoroscopy improved the image quality, lowered the kilovoltage requirements, and reduced the patient entrance dose by 55% and the operator dose by 69%. High-output pulsed fluoroscopy with a grid-switched tube and extra filtering improves the image quality and significantly reduces both the operator dose and patient dose.
doi_str_mv 10.1161/01.CIR.89.6.2710
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_212707537</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>25840923</sourcerecordid><originalsourceid>FETCH-LOGICAL-c433t-1635e80c181f0c32ab600e9ed806d7269bd1863db927f171ad702e364e504ad93</originalsourceid><addsrcrecordid>eNo9kc1q3DAUhUVpSadp990URMnWrn5syV6WIU0DgUJooTshS9djBY01kayk81R9xcqdIQshLuc7B-kehD5SUlMq6BdC6-3tfd31taiZpOQV2tCWNVXT8v412hBC-kpyxt6idyk9lFFw2V6gi46RVnTtBv29B5vN4sKMw4ijtk7_H-DPIaQcAT9PzgPeazcv5bh5hye3m6rHrL1bjnj0OcSQTDg4g91e7yBhm-PKFQfEJ5jXPO2x0dG64MPuiHNa9Tk8gce_q6iPeMkD4AXMNJ-IZ7dM5Q1L1HgAvcej8yWsuN6jN6P2CT6c70v069v1z-336u7Hze32611lGs6XigreQkcM7ehIDGd6EIRAD7Yjwkom-sHSTnA79EyOVFJtJWHARQMtabTt-SX6fMo9xPCYIS3qIeRY_pEUo0wS2XJZIHKCTFlBijCqQyw7iEdFiVr7UYSq0o_qeiXU2k-xfDrn5mEP9sVwLqToV2ddJ6P9GPVsXHrBGkYpJZL_AyFHnMQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>212707537</pqid></control><display><type>article</type><title>Reduction of radiation exposure while maintaining high-quality fluoroscopic images during interventional cardiology using novel X-ray tube technology with extra beam filtering</title><source>Journals@Ovid Ovid Autoload</source><source>MEDLINE</source><source>American Heart Association Journals</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><creator>AD DEN BOER ; DE FEYTER, P. J ; HUMMEL, W. A ; KEANE, D ; ROELANDT, J. R. T. C</creator><creatorcontrib>AD DEN BOER ; DE FEYTER, P. J ; HUMMEL, W. A ; KEANE, D ; ROELANDT, J. R. T. C</creatorcontrib><description>Radiographic technology plays an integral role in interventional cardiology. The number of interventions continues to increase, and the associated radiation exposure to patients and personnel is of major concern. This study was undertaken to determine whether a newly developed x-ray tube deploying grid-switched pulsed fluoroscopy and extra beam filtering can achieve a reduction in radiation exposure while maintaining fluoroscopic images of high quality. Three fluoroscopic techniques were compared: continuous fluoroscopy, pulsed fluoroscopy, and a newly developed high-output pulsed fluoroscopy with extra filtering. To ascertain differences in the quality of images and to determine differences in patient entrance and investigator radiation exposure, the radiated volume curve was measured to determine the required high voltage levels (kVpeak) for different object sizes for each fluoroscopic mode. The fluoroscopic data of 124 patient procedures were combined. The data were analyzed for radiographic projections, image intensifier field size, and x-ray tube kilovoltage levels (kVpeak). On the basis of this analysis, a reference procedure was constructed. The reference procedure was tested on a phantom or dummy patient by all three fluoroscopic modes. The phantom was so designed that the kilovoltage requirements for each projection were comparable to those needed for the average patient. Radiation exposure of the operator and patient was measured during each mode. The patient entrance dose was measured in air, and the operator dose was measured by 18 dosimeters on a dummy operator. Pulsed compared with continuous fluoroscopy could be performed with improved image quality at lower kilovoltages. The patient entrance dose was reduced by 21% and the operator dose by 54%. High-output pulsed fluoroscopy with extra beam filtering compared with continuous fluoroscopy improved the image quality, lowered the kilovoltage requirements, and reduced the patient entrance dose by 55% and the operator dose by 69%. High-output pulsed fluoroscopy with a grid-switched tube and extra filtering improves the image quality and significantly reduces both the operator dose and patient dose.</description><identifier>ISSN: 0009-7322</identifier><identifier>EISSN: 1524-4539</identifier><identifier>DOI: 10.1161/01.CIR.89.6.2710</identifier><identifier>PMID: 8205685</identifier><identifier>CODEN: CIRCAZ</identifier><language>eng</language><publisher>Hagerstown, MD: Lippincott Williams &amp; Wilkins</publisher><subject>Biological and medical sciences ; Cardiac Catheterization ; Cardiovascular system ; Fluoroscopy - methods ; Humans ; Investigative techniques, diagnostic techniques (general aspects) ; Medical sciences ; Radiation Dosage ; Radiodiagnosis. Nmr imagery. Nmr spectrometry ; X-Rays</subject><ispartof>Circulation (New York, N.Y.), 1994-06, Vol.89 (6), p.2710-2714</ispartof><rights>1994 INIST-CNRS</rights><rights>Copyright American Heart Association, Inc. Jun 1994</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c433t-1635e80c181f0c32ab600e9ed806d7269bd1863db927f171ad702e364e504ad93</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,3674,27901,27902</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=4211107$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/8205685$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>AD DEN BOER</creatorcontrib><creatorcontrib>DE FEYTER, P. J</creatorcontrib><creatorcontrib>HUMMEL, W. A</creatorcontrib><creatorcontrib>KEANE, D</creatorcontrib><creatorcontrib>ROELANDT, J. R. T. C</creatorcontrib><title>Reduction of radiation exposure while maintaining high-quality fluoroscopic images during interventional cardiology using novel X-ray tube technology with extra beam filtering</title><title>Circulation (New York, N.Y.)</title><addtitle>Circulation</addtitle><description>Radiographic technology plays an integral role in interventional cardiology. The number of interventions continues to increase, and the associated radiation exposure to patients and personnel is of major concern. This study was undertaken to determine whether a newly developed x-ray tube deploying grid-switched pulsed fluoroscopy and extra beam filtering can achieve a reduction in radiation exposure while maintaining fluoroscopic images of high quality. Three fluoroscopic techniques were compared: continuous fluoroscopy, pulsed fluoroscopy, and a newly developed high-output pulsed fluoroscopy with extra filtering. To ascertain differences in the quality of images and to determine differences in patient entrance and investigator radiation exposure, the radiated volume curve was measured to determine the required high voltage levels (kVpeak) for different object sizes for each fluoroscopic mode. The fluoroscopic data of 124 patient procedures were combined. The data were analyzed for radiographic projections, image intensifier field size, and x-ray tube kilovoltage levels (kVpeak). On the basis of this analysis, a reference procedure was constructed. The reference procedure was tested on a phantom or dummy patient by all three fluoroscopic modes. The phantom was so designed that the kilovoltage requirements for each projection were comparable to those needed for the average patient. Radiation exposure of the operator and patient was measured during each mode. The patient entrance dose was measured in air, and the operator dose was measured by 18 dosimeters on a dummy operator. Pulsed compared with continuous fluoroscopy could be performed with improved image quality at lower kilovoltages. The patient entrance dose was reduced by 21% and the operator dose by 54%. High-output pulsed fluoroscopy with extra beam filtering compared with continuous fluoroscopy improved the image quality, lowered the kilovoltage requirements, and reduced the patient entrance dose by 55% and the operator dose by 69%. High-output pulsed fluoroscopy with a grid-switched tube and extra filtering improves the image quality and significantly reduces both the operator dose and patient dose.</description><subject>Biological and medical sciences</subject><subject>Cardiac Catheterization</subject><subject>Cardiovascular system</subject><subject>Fluoroscopy - methods</subject><subject>Humans</subject><subject>Investigative techniques, diagnostic techniques (general aspects)</subject><subject>Medical sciences</subject><subject>Radiation Dosage</subject><subject>Radiodiagnosis. Nmr imagery. Nmr spectrometry</subject><subject>X-Rays</subject><issn>0009-7322</issn><issn>1524-4539</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1994</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo9kc1q3DAUhUVpSadp990URMnWrn5syV6WIU0DgUJooTshS9djBY01kayk81R9xcqdIQshLuc7B-kehD5SUlMq6BdC6-3tfd31taiZpOQV2tCWNVXT8v412hBC-kpyxt6idyk9lFFw2V6gi46RVnTtBv29B5vN4sKMw4ijtk7_H-DPIaQcAT9PzgPeazcv5bh5hye3m6rHrL1bjnj0OcSQTDg4g91e7yBhm-PKFQfEJ5jXPO2x0dG64MPuiHNa9Tk8gce_q6iPeMkD4AXMNJ-IZ7dM5Q1L1HgAvcej8yWsuN6jN6P2CT6c70v069v1z-336u7Hze32611lGs6XigreQkcM7ehIDGd6EIRAD7Yjwkom-sHSTnA79EyOVFJtJWHARQMtabTt-SX6fMo9xPCYIS3qIeRY_pEUo0wS2XJZIHKCTFlBijCqQyw7iEdFiVr7UYSq0o_qeiXU2k-xfDrn5mEP9sVwLqToV2ddJ6P9GPVsXHrBGkYpJZL_AyFHnMQ</recordid><startdate>19940601</startdate><enddate>19940601</enddate><creator>AD DEN BOER</creator><creator>DE FEYTER, P. J</creator><creator>HUMMEL, W. A</creator><creator>KEANE, D</creator><creator>ROELANDT, J. R. T. C</creator><general>Lippincott Williams &amp; Wilkins</general><general>American Heart Association, Inc</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>K9.</scope><scope>NAPCQ</scope><scope>U9A</scope></search><sort><creationdate>19940601</creationdate><title>Reduction of radiation exposure while maintaining high-quality fluoroscopic images during interventional cardiology using novel X-ray tube technology with extra beam filtering</title><author>AD DEN BOER ; DE FEYTER, P. J ; HUMMEL, W. A ; KEANE, D ; ROELANDT, J. R. T. C</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c433t-1635e80c181f0c32ab600e9ed806d7269bd1863db927f171ad702e364e504ad93</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1994</creationdate><topic>Biological and medical sciences</topic><topic>Cardiac Catheterization</topic><topic>Cardiovascular system</topic><topic>Fluoroscopy - methods</topic><topic>Humans</topic><topic>Investigative techniques, diagnostic techniques (general aspects)</topic><topic>Medical sciences</topic><topic>Radiation Dosage</topic><topic>Radiodiagnosis. Nmr imagery. Nmr spectrometry</topic><topic>X-Rays</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>AD DEN BOER</creatorcontrib><creatorcontrib>DE FEYTER, P. J</creatorcontrib><creatorcontrib>HUMMEL, W. A</creatorcontrib><creatorcontrib>KEANE, D</creatorcontrib><creatorcontrib>ROELANDT, J. R. T. C</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Nursing &amp; Allied Health Premium</collection><jtitle>Circulation (New York, N.Y.)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>AD DEN BOER</au><au>DE FEYTER, P. J</au><au>HUMMEL, W. A</au><au>KEANE, D</au><au>ROELANDT, J. R. T. C</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Reduction of radiation exposure while maintaining high-quality fluoroscopic images during interventional cardiology using novel X-ray tube technology with extra beam filtering</atitle><jtitle>Circulation (New York, N.Y.)</jtitle><addtitle>Circulation</addtitle><date>1994-06-01</date><risdate>1994</risdate><volume>89</volume><issue>6</issue><spage>2710</spage><epage>2714</epage><pages>2710-2714</pages><issn>0009-7322</issn><eissn>1524-4539</eissn><coden>CIRCAZ</coden><abstract>Radiographic technology plays an integral role in interventional cardiology. The number of interventions continues to increase, and the associated radiation exposure to patients and personnel is of major concern. This study was undertaken to determine whether a newly developed x-ray tube deploying grid-switched pulsed fluoroscopy and extra beam filtering can achieve a reduction in radiation exposure while maintaining fluoroscopic images of high quality. Three fluoroscopic techniques were compared: continuous fluoroscopy, pulsed fluoroscopy, and a newly developed high-output pulsed fluoroscopy with extra filtering. To ascertain differences in the quality of images and to determine differences in patient entrance and investigator radiation exposure, the radiated volume curve was measured to determine the required high voltage levels (kVpeak) for different object sizes for each fluoroscopic mode. The fluoroscopic data of 124 patient procedures were combined. The data were analyzed for radiographic projections, image intensifier field size, and x-ray tube kilovoltage levels (kVpeak). On the basis of this analysis, a reference procedure was constructed. The reference procedure was tested on a phantom or dummy patient by all three fluoroscopic modes. The phantom was so designed that the kilovoltage requirements for each projection were comparable to those needed for the average patient. Radiation exposure of the operator and patient was measured during each mode. The patient entrance dose was measured in air, and the operator dose was measured by 18 dosimeters on a dummy operator. Pulsed compared with continuous fluoroscopy could be performed with improved image quality at lower kilovoltages. The patient entrance dose was reduced by 21% and the operator dose by 54%. High-output pulsed fluoroscopy with extra beam filtering compared with continuous fluoroscopy improved the image quality, lowered the kilovoltage requirements, and reduced the patient entrance dose by 55% and the operator dose by 69%. High-output pulsed fluoroscopy with a grid-switched tube and extra filtering improves the image quality and significantly reduces both the operator dose and patient dose.</abstract><cop>Hagerstown, MD</cop><pub>Lippincott Williams &amp; Wilkins</pub><pmid>8205685</pmid><doi>10.1161/01.CIR.89.6.2710</doi><tpages>5</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0009-7322
ispartof Circulation (New York, N.Y.), 1994-06, Vol.89 (6), p.2710-2714
issn 0009-7322
1524-4539
language eng
recordid cdi_proquest_journals_212707537
source Journals@Ovid Ovid Autoload; MEDLINE; American Heart Association Journals; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals
subjects Biological and medical sciences
Cardiac Catheterization
Cardiovascular system
Fluoroscopy - methods
Humans
Investigative techniques, diagnostic techniques (general aspects)
Medical sciences
Radiation Dosage
Radiodiagnosis. Nmr imagery. Nmr spectrometry
X-Rays
title Reduction of radiation exposure while maintaining high-quality fluoroscopic images during interventional cardiology using novel X-ray tube technology with extra beam filtering
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-08T20%3A11%3A07IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Reduction%20of%20radiation%20exposure%20while%20maintaining%20high-quality%20fluoroscopic%20images%20during%20interventional%20cardiology%20using%20novel%20X-ray%20tube%20technology%20with%20extra%20beam%20filtering&rft.jtitle=Circulation%20(New%20York,%20N.Y.)&rft.au=AD%20DEN%20BOER&rft.date=1994-06-01&rft.volume=89&rft.issue=6&rft.spage=2710&rft.epage=2714&rft.pages=2710-2714&rft.issn=0009-7322&rft.eissn=1524-4539&rft.coden=CIRCAZ&rft_id=info:doi/10.1161/01.CIR.89.6.2710&rft_dat=%3Cproquest_cross%3E25840923%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=212707537&rft_id=info:pmid/8205685&rfr_iscdi=true