Stent-based approach for venticle-to-coronary artery bypass
BACKGROUND: Ventricle-to-coronary artery bypass (VCAB) is an experimental revascularization procedure that provides predominantly systolic instead of diastolic blood flow to a coronary artery. METHODS AND RESULTS: In a pig model, a stent-based procedure (VSTENT) was developed to create a VCAB. After...
Gespeichert in:
Veröffentlicht in: | Circulation (New York, N.Y.) N.Y.), 2002-08, Vol.106 (8), p.1000 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | 8 |
container_start_page | 1000 |
container_title | Circulation (New York, N.Y.) |
container_volume | 106 |
creator | Boekstegers, Peter Raake, Philip Rasul Al Ghobainy Horstkotte, Jan |
description | BACKGROUND: Ventricle-to-coronary artery bypass (VCAB) is an experimental revascularization procedure that provides predominantly systolic instead of diastolic blood flow to a coronary artery. METHODS AND RESULTS: In a pig model, a stent-based procedure (VSTENT) was developed to create a VCAB. After thoracotomy, a covered VSTENT was implanted between the left ventricle and the left anterior descending coronary artery (LAD). Distal LAD flow, regional myocardial function, and intracoronary pressures were determined at different degrees of LAD stenosis and during complete LAD occlusion. During 3 hours of LAD occlusion, VSTENT preserved net forward flow at 70+/-6% and regional myocardial function at 71+/-8% of baseline. Preservation of net flow was influenced by the positioning of the VSTENT, with higher preservation also under conditions of increased oxygen demand if a "valve-like mechanism" was present during diastole. At a hemodynamically relevant level of LAD stenosis (>70%), systolic inflow was predominant after VSTENT implantation. Changes in mean diastolic intracoronary pressure that resulted from different degrees of LAD stenosis were linearly correlated to net flow after VSTENT implantation (r=0.88; P |
format | Article |
fullrecord | <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_journals_212680008</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>163835631</sourcerecordid><originalsourceid>FETCH-proquest_journals_2126800083</originalsourceid><addsrcrecordid>eNqNjckKwjAURYMoWId_CO4DadJ0wKUo7nVfXmOKlpLEvFTo35uFH-DqcAfuXZAsV6JghZLNkmSc84ZVUog12SAOSZayUhk53qKxkXWA5kHB--BAP2nvAv0k_6VHw6Jj2gVnIcwUQjQJ3ewBcUdWPYxo9j9uyeFyvp-uLK28J4OxHdwUbIpakYuyTqe1_Kv0BamBOG0</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>212680008</pqid></control><display><type>article</type><title>Stent-based approach for venticle-to-coronary artery bypass</title><source>American Heart Association Journals</source><source>Journals@Ovid Complete</source><source>EZB-FREE-00999 freely available EZB journals</source><creator>Boekstegers, Peter ; Raake, Philip ; Rasul Al Ghobainy ; Horstkotte, Jan</creator><creatorcontrib>Boekstegers, Peter ; Raake, Philip ; Rasul Al Ghobainy ; Horstkotte, Jan</creatorcontrib><description>BACKGROUND: Ventricle-to-coronary artery bypass (VCAB) is an experimental revascularization procedure that provides predominantly systolic instead of diastolic blood flow to a coronary artery. METHODS AND RESULTS: In a pig model, a stent-based procedure (VSTENT) was developed to create a VCAB. After thoracotomy, a covered VSTENT was implanted between the left ventricle and the left anterior descending coronary artery (LAD). Distal LAD flow, regional myocardial function, and intracoronary pressures were determined at different degrees of LAD stenosis and during complete LAD occlusion. During 3 hours of LAD occlusion, VSTENT preserved net forward flow at 70+/-6% and regional myocardial function at 71+/-8% of baseline. Preservation of net flow was influenced by the positioning of the VSTENT, with higher preservation also under conditions of increased oxygen demand if a "valve-like mechanism" was present during diastole. At a hemodynamically relevant level of LAD stenosis (>70%), systolic inflow was predominant after VSTENT implantation. Changes in mean diastolic intracoronary pressure that resulted from different degrees of LAD stenosis were linearly correlated to net flow after VSTENT implantation (r=0.88; P<0.001). CONCLUSIONS: VSTENT for ventricle-to-coronary artery bypass was feasible and preserved 70+/-6% of baseline flow during complete LAD occlusion. The degree of preservation was dependent on the position of the VSTENT creating a valve-like mechanism during diastole. Residual diastolic blood flow through a high-grade LAD stenosis influenced net flow favorably, because diastolic backflow decreased with increasing mean diastolic intracoronary pressure.</description><identifier>ISSN: 0009-7322</identifier><identifier>EISSN: 1524-4539</identifier><identifier>CODEN: CIRCAZ</identifier><language>eng</language><publisher>Baltimore: American Heart Association, Inc</publisher><ispartof>Circulation (New York, N.Y.), 2002-08, Vol.106 (8), p.1000</ispartof><rights>Copyright American Heart Association, Inc. Aug 20, 2002</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784</link.rule.ids></links><search><creatorcontrib>Boekstegers, Peter</creatorcontrib><creatorcontrib>Raake, Philip</creatorcontrib><creatorcontrib>Rasul Al Ghobainy</creatorcontrib><creatorcontrib>Horstkotte, Jan</creatorcontrib><title>Stent-based approach for venticle-to-coronary artery bypass</title><title>Circulation (New York, N.Y.)</title><description>BACKGROUND: Ventricle-to-coronary artery bypass (VCAB) is an experimental revascularization procedure that provides predominantly systolic instead of diastolic blood flow to a coronary artery. METHODS AND RESULTS: In a pig model, a stent-based procedure (VSTENT) was developed to create a VCAB. After thoracotomy, a covered VSTENT was implanted between the left ventricle and the left anterior descending coronary artery (LAD). Distal LAD flow, regional myocardial function, and intracoronary pressures were determined at different degrees of LAD stenosis and during complete LAD occlusion. During 3 hours of LAD occlusion, VSTENT preserved net forward flow at 70+/-6% and regional myocardial function at 71+/-8% of baseline. Preservation of net flow was influenced by the positioning of the VSTENT, with higher preservation also under conditions of increased oxygen demand if a "valve-like mechanism" was present during diastole. At a hemodynamically relevant level of LAD stenosis (>70%), systolic inflow was predominant after VSTENT implantation. Changes in mean diastolic intracoronary pressure that resulted from different degrees of LAD stenosis were linearly correlated to net flow after VSTENT implantation (r=0.88; P<0.001). CONCLUSIONS: VSTENT for ventricle-to-coronary artery bypass was feasible and preserved 70+/-6% of baseline flow during complete LAD occlusion. The degree of preservation was dependent on the position of the VSTENT creating a valve-like mechanism during diastole. Residual diastolic blood flow through a high-grade LAD stenosis influenced net flow favorably, because diastolic backflow decreased with increasing mean diastolic intracoronary pressure.</description><issn>0009-7322</issn><issn>1524-4539</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2002</creationdate><recordtype>article</recordtype><recordid>eNqNjckKwjAURYMoWId_CO4DadJ0wKUo7nVfXmOKlpLEvFTo35uFH-DqcAfuXZAsV6JghZLNkmSc84ZVUog12SAOSZayUhk53qKxkXWA5kHB--BAP2nvAv0k_6VHw6Jj2gVnIcwUQjQJ3ewBcUdWPYxo9j9uyeFyvp-uLK28J4OxHdwUbIpakYuyTqe1_Kv0BamBOG0</recordid><startdate>20020820</startdate><enddate>20020820</enddate><creator>Boekstegers, Peter</creator><creator>Raake, Philip</creator><creator>Rasul Al Ghobainy</creator><creator>Horstkotte, Jan</creator><general>American Heart Association, Inc</general><scope>K9.</scope><scope>NAPCQ</scope><scope>U9A</scope></search><sort><creationdate>20020820</creationdate><title>Stent-based approach for venticle-to-coronary artery bypass</title><author>Boekstegers, Peter ; Raake, Philip ; Rasul Al Ghobainy ; Horstkotte, Jan</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_journals_2126800083</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2002</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Boekstegers, Peter</creatorcontrib><creatorcontrib>Raake, Philip</creatorcontrib><creatorcontrib>Rasul Al Ghobainy</creatorcontrib><creatorcontrib>Horstkotte, Jan</creatorcontrib><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>Nursing & Allied Health Premium</collection><jtitle>Circulation (New York, N.Y.)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Boekstegers, Peter</au><au>Raake, Philip</au><au>Rasul Al Ghobainy</au><au>Horstkotte, Jan</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Stent-based approach for venticle-to-coronary artery bypass</atitle><jtitle>Circulation (New York, N.Y.)</jtitle><date>2002-08-20</date><risdate>2002</risdate><volume>106</volume><issue>8</issue><spage>1000</spage><pages>1000-</pages><issn>0009-7322</issn><eissn>1524-4539</eissn><coden>CIRCAZ</coden><abstract>BACKGROUND: Ventricle-to-coronary artery bypass (VCAB) is an experimental revascularization procedure that provides predominantly systolic instead of diastolic blood flow to a coronary artery. METHODS AND RESULTS: In a pig model, a stent-based procedure (VSTENT) was developed to create a VCAB. After thoracotomy, a covered VSTENT was implanted between the left ventricle and the left anterior descending coronary artery (LAD). Distal LAD flow, regional myocardial function, and intracoronary pressures were determined at different degrees of LAD stenosis and during complete LAD occlusion. During 3 hours of LAD occlusion, VSTENT preserved net forward flow at 70+/-6% and regional myocardial function at 71+/-8% of baseline. Preservation of net flow was influenced by the positioning of the VSTENT, with higher preservation also under conditions of increased oxygen demand if a "valve-like mechanism" was present during diastole. At a hemodynamically relevant level of LAD stenosis (>70%), systolic inflow was predominant after VSTENT implantation. Changes in mean diastolic intracoronary pressure that resulted from different degrees of LAD stenosis were linearly correlated to net flow after VSTENT implantation (r=0.88; P<0.001). CONCLUSIONS: VSTENT for ventricle-to-coronary artery bypass was feasible and preserved 70+/-6% of baseline flow during complete LAD occlusion. The degree of preservation was dependent on the position of the VSTENT creating a valve-like mechanism during diastole. Residual diastolic blood flow through a high-grade LAD stenosis influenced net flow favorably, because diastolic backflow decreased with increasing mean diastolic intracoronary pressure.</abstract><cop>Baltimore</cop><pub>American Heart Association, Inc</pub></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0009-7322 |
ispartof | Circulation (New York, N.Y.), 2002-08, Vol.106 (8), p.1000 |
issn | 0009-7322 1524-4539 |
language | eng |
recordid | cdi_proquest_journals_212680008 |
source | American Heart Association Journals; Journals@Ovid Complete; EZB-FREE-00999 freely available EZB journals |
title | Stent-based approach for venticle-to-coronary artery bypass |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-09T11%3A41%3A23IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Stent-based%20approach%20for%20venticle-to-coronary%20artery%20bypass&rft.jtitle=Circulation%20(New%20York,%20N.Y.)&rft.au=Boekstegers,%20Peter&rft.date=2002-08-20&rft.volume=106&rft.issue=8&rft.spage=1000&rft.pages=1000-&rft.issn=0009-7322&rft.eissn=1524-4539&rft.coden=CIRCAZ&rft_id=info:doi/&rft_dat=%3Cproquest%3E163835631%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=212680008&rft_id=info:pmid/&rfr_iscdi=true |