Cost, reliability, and sensitivity of a stand-alone hybrid renewable energy system—A case study on a lecture building with low load factor
Single source renewable energy systems exhibit strong short term and seasonal variations in their outputs for which hybrid systems are the need of the hour. Taking consideration of the location, user requirements, cost, reliability, etc., the hybrid systems are designed. The objective of the present...
Gespeichert in:
Veröffentlicht in: | Journal of renewable and sustainable energy 2015-01, Vol.7 (1) |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | 1 |
container_start_page | |
container_title | Journal of renewable and sustainable energy |
container_volume | 7 |
creator | Gangwar, S. Bhanja, D. Biswas, A. |
description | Single source renewable energy systems exhibit strong short term and seasonal variations in their outputs for which hybrid systems are the need of the hour. Taking consideration of the location, user requirements, cost, reliability, etc., the hybrid systems are designed. The objective of the present study is to evaluate cost and reliability of a standalone hybrid renewable energy system (HRES) to be utilized for a lecture building of a technical institute with low load factor. Different combinations of HRES involving horizontal axis wind turbine, solar photo voltaic (PV), proton exchange membrane fuel cell with electrolyzer, and battery bank have been studied. Four such systems have been modeled using hybrid optimization model for electric renewable HOMER software, and these are techno-economically evaluated for the existing low load factor conditions of the building. Futuristic growth of load demand is also incorporated to analyze the results. It has been found that the combination of wind turbines, solar PV system, and battery bank gives the most cost effective hybrid system for both the load scenarios. And PV, fuel cell, wind turbine, and battery bank type HRES have the better reliability in terms of lower unmet load. |
doi_str_mv | 10.1063/1.4906916 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2124933273</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2124933273</sourcerecordid><originalsourceid>FETCH-LOGICAL-c257t-25eee09f2a71a762b5593ed59892353531e6ff4cc11a3b8de3238facdf0b2f183</originalsourceid><addsrcrecordid>eNpNUMtKAzEUDaJgrS78g4AroVPzmEezLMUXFNzoeshMbtqUdFKTjGV2foBLv9AvMdIu5HK5h8M598BB6JqSKSUlv6PTXJBS0PIEjajIaVYRyk7_4XN0EcKGkJKRgo3Q18KFOMEerJGNsSYOEyw7hQN0wUTzkQjsNJY4xERn0roO8HpovFHJ1MFeNhZwAn414DCECNufz-85bmWA5OlVsnfJbqGNvQfc9MYq063w3sQ1tm6fViqsZRudv0RnWtoAV8c7Rm8P96-Lp2z58vi8mC-zlhVVzFgBAERoJisqq5I1RSE4qELMBONFGgql1nnbUip5M1PAGZ-lBKVJwzSd8TG6OfzdeffeQ4j1xvW-S5E1oywXnLOKJ9XtQdV6F4IHXe-82Uo_1JTUf2XXtD6WzX8BuPdzvA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2124933273</pqid></control><display><type>article</type><title>Cost, reliability, and sensitivity of a stand-alone hybrid renewable energy system—A case study on a lecture building with low load factor</title><source>AIP Journals Complete</source><creator>Gangwar, S. ; Bhanja, D. ; Biswas, A.</creator><creatorcontrib>Gangwar, S. ; Bhanja, D. ; Biswas, A.</creatorcontrib><description>Single source renewable energy systems exhibit strong short term and seasonal variations in their outputs for which hybrid systems are the need of the hour. Taking consideration of the location, user requirements, cost, reliability, etc., the hybrid systems are designed. The objective of the present study is to evaluate cost and reliability of a standalone hybrid renewable energy system (HRES) to be utilized for a lecture building of a technical institute with low load factor. Different combinations of HRES involving horizontal axis wind turbine, solar photo voltaic (PV), proton exchange membrane fuel cell with electrolyzer, and battery bank have been studied. Four such systems have been modeled using hybrid optimization model for electric renewable HOMER software, and these are techno-economically evaluated for the existing low load factor conditions of the building. Futuristic growth of load demand is also incorporated to analyze the results. It has been found that the combination of wind turbines, solar PV system, and battery bank gives the most cost effective hybrid system for both the load scenarios. And PV, fuel cell, wind turbine, and battery bank type HRES have the better reliability in terms of lower unmet load.</description><identifier>ISSN: 1941-7012</identifier><identifier>EISSN: 1941-7012</identifier><identifier>DOI: 10.1063/1.4906916</identifier><language>eng</language><publisher>Melville: American Institute of Physics</publisher><subject>Alternative energy ; Annual variations ; Batteries ; Economic models ; Energy storage ; Fuel cells ; Horizontal Axis Wind Turbines ; Hybrid systems ; Photovoltaic cells ; Proton exchange membrane fuel cells ; Reliability analysis ; Renewable energy ; Renewable resources ; Solar cells ; User requirements ; Wind turbines</subject><ispartof>Journal of renewable and sustainable energy, 2015-01, Vol.7 (1)</ispartof><rights>2015 AIP Publishing LLC.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c257t-25eee09f2a71a762b5593ed59892353531e6ff4cc11a3b8de3238facdf0b2f183</citedby><cites>FETCH-LOGICAL-c257t-25eee09f2a71a762b5593ed59892353531e6ff4cc11a3b8de3238facdf0b2f183</cites><orcidid>0000-0002-3852-6564 ; 0000-0002-3074-5340</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27903,27904</link.rule.ids></links><search><creatorcontrib>Gangwar, S.</creatorcontrib><creatorcontrib>Bhanja, D.</creatorcontrib><creatorcontrib>Biswas, A.</creatorcontrib><title>Cost, reliability, and sensitivity of a stand-alone hybrid renewable energy system—A case study on a lecture building with low load factor</title><title>Journal of renewable and sustainable energy</title><description>Single source renewable energy systems exhibit strong short term and seasonal variations in their outputs for which hybrid systems are the need of the hour. Taking consideration of the location, user requirements, cost, reliability, etc., the hybrid systems are designed. The objective of the present study is to evaluate cost and reliability of a standalone hybrid renewable energy system (HRES) to be utilized for a lecture building of a technical institute with low load factor. Different combinations of HRES involving horizontal axis wind turbine, solar photo voltaic (PV), proton exchange membrane fuel cell with electrolyzer, and battery bank have been studied. Four such systems have been modeled using hybrid optimization model for electric renewable HOMER software, and these are techno-economically evaluated for the existing low load factor conditions of the building. Futuristic growth of load demand is also incorporated to analyze the results. It has been found that the combination of wind turbines, solar PV system, and battery bank gives the most cost effective hybrid system for both the load scenarios. And PV, fuel cell, wind turbine, and battery bank type HRES have the better reliability in terms of lower unmet load.</description><subject>Alternative energy</subject><subject>Annual variations</subject><subject>Batteries</subject><subject>Economic models</subject><subject>Energy storage</subject><subject>Fuel cells</subject><subject>Horizontal Axis Wind Turbines</subject><subject>Hybrid systems</subject><subject>Photovoltaic cells</subject><subject>Proton exchange membrane fuel cells</subject><subject>Reliability analysis</subject><subject>Renewable energy</subject><subject>Renewable resources</subject><subject>Solar cells</subject><subject>User requirements</subject><subject>Wind turbines</subject><issn>1941-7012</issn><issn>1941-7012</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><recordid>eNpNUMtKAzEUDaJgrS78g4AroVPzmEezLMUXFNzoeshMbtqUdFKTjGV2foBLv9AvMdIu5HK5h8M598BB6JqSKSUlv6PTXJBS0PIEjajIaVYRyk7_4XN0EcKGkJKRgo3Q18KFOMEerJGNsSYOEyw7hQN0wUTzkQjsNJY4xERn0roO8HpovFHJ1MFeNhZwAn414DCECNufz-85bmWA5OlVsnfJbqGNvQfc9MYq063w3sQ1tm6fViqsZRudv0RnWtoAV8c7Rm8P96-Lp2z58vi8mC-zlhVVzFgBAERoJisqq5I1RSE4qELMBONFGgql1nnbUip5M1PAGZ-lBKVJwzSd8TG6OfzdeffeQ4j1xvW-S5E1oywXnLOKJ9XtQdV6F4IHXe-82Uo_1JTUf2XXtD6WzX8BuPdzvA</recordid><startdate>20150101</startdate><enddate>20150101</enddate><creator>Gangwar, S.</creator><creator>Bhanja, D.</creator><creator>Biswas, A.</creator><general>American Institute of Physics</general><scope>AAYXX</scope><scope>CITATION</scope><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope><orcidid>https://orcid.org/0000-0002-3852-6564</orcidid><orcidid>https://orcid.org/0000-0002-3074-5340</orcidid></search><sort><creationdate>20150101</creationdate><title>Cost, reliability, and sensitivity of a stand-alone hybrid renewable energy system—A case study on a lecture building with low load factor</title><author>Gangwar, S. ; Bhanja, D. ; Biswas, A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c257t-25eee09f2a71a762b5593ed59892353531e6ff4cc11a3b8de3238facdf0b2f183</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Alternative energy</topic><topic>Annual variations</topic><topic>Batteries</topic><topic>Economic models</topic><topic>Energy storage</topic><topic>Fuel cells</topic><topic>Horizontal Axis Wind Turbines</topic><topic>Hybrid systems</topic><topic>Photovoltaic cells</topic><topic>Proton exchange membrane fuel cells</topic><topic>Reliability analysis</topic><topic>Renewable energy</topic><topic>Renewable resources</topic><topic>Solar cells</topic><topic>User requirements</topic><topic>Wind turbines</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Gangwar, S.</creatorcontrib><creatorcontrib>Bhanja, D.</creatorcontrib><creatorcontrib>Biswas, A.</creatorcontrib><collection>CrossRef</collection><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Journal of renewable and sustainable energy</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Gangwar, S.</au><au>Bhanja, D.</au><au>Biswas, A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Cost, reliability, and sensitivity of a stand-alone hybrid renewable energy system—A case study on a lecture building with low load factor</atitle><jtitle>Journal of renewable and sustainable energy</jtitle><date>2015-01-01</date><risdate>2015</risdate><volume>7</volume><issue>1</issue><issn>1941-7012</issn><eissn>1941-7012</eissn><abstract>Single source renewable energy systems exhibit strong short term and seasonal variations in their outputs for which hybrid systems are the need of the hour. Taking consideration of the location, user requirements, cost, reliability, etc., the hybrid systems are designed. The objective of the present study is to evaluate cost and reliability of a standalone hybrid renewable energy system (HRES) to be utilized for a lecture building of a technical institute with low load factor. Different combinations of HRES involving horizontal axis wind turbine, solar photo voltaic (PV), proton exchange membrane fuel cell with electrolyzer, and battery bank have been studied. Four such systems have been modeled using hybrid optimization model for electric renewable HOMER software, and these are techno-economically evaluated for the existing low load factor conditions of the building. Futuristic growth of load demand is also incorporated to analyze the results. It has been found that the combination of wind turbines, solar PV system, and battery bank gives the most cost effective hybrid system for both the load scenarios. And PV, fuel cell, wind turbine, and battery bank type HRES have the better reliability in terms of lower unmet load.</abstract><cop>Melville</cop><pub>American Institute of Physics</pub><doi>10.1063/1.4906916</doi><orcidid>https://orcid.org/0000-0002-3852-6564</orcidid><orcidid>https://orcid.org/0000-0002-3074-5340</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1941-7012 |
ispartof | Journal of renewable and sustainable energy, 2015-01, Vol.7 (1) |
issn | 1941-7012 1941-7012 |
language | eng |
recordid | cdi_proquest_journals_2124933273 |
source | AIP Journals Complete |
subjects | Alternative energy Annual variations Batteries Economic models Energy storage Fuel cells Horizontal Axis Wind Turbines Hybrid systems Photovoltaic cells Proton exchange membrane fuel cells Reliability analysis Renewable energy Renewable resources Solar cells User requirements Wind turbines |
title | Cost, reliability, and sensitivity of a stand-alone hybrid renewable energy system—A case study on a lecture building with low load factor |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-27T22%3A44%3A14IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Cost,%20reliability,%20and%20sensitivity%20of%20a%20stand-alone%20hybrid%20renewable%20energy%20system%E2%80%94A%20case%20study%20on%20a%20lecture%20building%20with%20low%20load%20factor&rft.jtitle=Journal%20of%20renewable%20and%20sustainable%20energy&rft.au=Gangwar,%20S.&rft.date=2015-01-01&rft.volume=7&rft.issue=1&rft.issn=1941-7012&rft.eissn=1941-7012&rft_id=info:doi/10.1063/1.4906916&rft_dat=%3Cproquest_cross%3E2124933273%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2124933273&rft_id=info:pmid/&rfr_iscdi=true |