Infusion Pump: Mathematical Modeling Graphic Bond for Blood Pressure Control
This article presents a proposal for a mathematical modeling based on Bond Graph (BG) technique to simulate a continuous infusion pump. It presents a mathematical model that controls the infusion of medication to control the Mean Arterial Pressure (MAP), in which there should be a linear pattern and...
Gespeichert in:
Veröffentlicht in: | Revista IEEE América Latina 2018-06, Vol.16 (6), p.1569 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | por ; spa |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | 6 |
container_start_page | 1569 |
container_title | Revista IEEE América Latina |
container_volume | 16 |
creator | Joziane Porcino da Silva Beatriz Araujo Rodrigues Jocyellen Christyne da Silva Casado Suelia de Siqueira Rodrigues Fleury Rosa |
description | This article presents a proposal for a mathematical modeling based on Bond Graph (BG) technique to simulate a continuous infusion pump. It presents a mathematical model that controls the infusion of medication to control the Mean Arterial Pressure (MAP), in which there should be a linear pattern and a very small error range in order to obtain the effectiveness of the procedure. For this, it uses dynamic modern control techniques knowledge of the mechanical parameters, for analyzing the pressure data and process control via an electronically controlled infusion pump. This study has two objectives: i) identification of the mathematical model of the infusion procedure by a bomb and ii) Fuzzy Controller. The contribution of this study is to present the mathematical model, with refinements based on prior knowledge of the phenomena involved and dynamic control analysis of the mathematical model with the use of fuzzy control. |
doi_str_mv | 10.1109/TLA.2018.8444151 |
format | Article |
fullrecord | <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_journals_2117147057</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2117147057</sourcerecordid><originalsourceid>FETCH-LOGICAL-p98t-86134d10dbbee903e631bbc18b8cbbad561a45c2a531bef540b3b8430d6937d43</originalsourceid><addsrcrecordid>eNpNjcFPwyAcRonRxDm9eyTx3MqvQAvetsbNJV3cofcFCnVdOqhA_3-X6MHT9_IO70PoGUgOQORr26zygoDIBWMMONygBXAmMiJlcfuP79FDjGdCqCgFXaBm5_o5Dt7hw3yZ3vBepZO9qDR0asR7b-w4uC-8DWo6DR1ee2dw7wNej94bfAg2xjlYXHuXgh8f0V2vxmif_naJ2s17W39kzed2V6-abJIiZaIEygwQo7W1klBbUtC6A6FFp7UyvATFeFcofvW254xoqgWjxJSSVobRJXr5zU7Bf882puPZz8FdH48FQAWsIryiP-AFT2I</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2117147057</pqid></control><display><type>article</type><title>Infusion Pump: Mathematical Modeling Graphic Bond for Blood Pressure Control</title><source>IEEE Electronic Library (IEL)</source><creator>Joziane Porcino da Silva ; Beatriz Araujo Rodrigues ; Jocyellen Christyne da Silva Casado ; Suelia de Siqueira Rodrigues Fleury Rosa</creator><creatorcontrib>Joziane Porcino da Silva ; Beatriz Araujo Rodrigues ; Jocyellen Christyne da Silva Casado ; Suelia de Siqueira Rodrigues Fleury Rosa</creatorcontrib><description>This article presents a proposal for a mathematical modeling based on Bond Graph (BG) technique to simulate a continuous infusion pump. It presents a mathematical model that controls the infusion of medication to control the Mean Arterial Pressure (MAP), in which there should be a linear pattern and a very small error range in order to obtain the effectiveness of the procedure. For this, it uses dynamic modern control techniques knowledge of the mechanical parameters, for analyzing the pressure data and process control via an electronically controlled infusion pump. This study has two objectives: i) identification of the mathematical model of the infusion procedure by a bomb and ii) Fuzzy Controller. The contribution of this study is to present the mathematical model, with refinements based on prior knowledge of the phenomena involved and dynamic control analysis of the mathematical model with the use of fuzzy control.</description><identifier>ISSN: 1548-0992</identifier><identifier>EISSN: 1548-0992</identifier><identifier>DOI: 10.1109/TLA.2018.8444151</identifier><language>por ; spa</language><publisher>Los Alamitos: The Institute of Electrical and Electronics Engineers, Inc. (IEEE)</publisher><subject>Blood pressure ; Computer simulation ; Dynamic control ; Fuzzy control ; Mathematical models ; Mechanical properties</subject><ispartof>Revista IEEE América Latina, 2018-06, Vol.16 (6), p.1569</ispartof><rights>Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) 2018</rights><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Joziane Porcino da Silva</creatorcontrib><creatorcontrib>Beatriz Araujo Rodrigues</creatorcontrib><creatorcontrib>Jocyellen Christyne da Silva Casado</creatorcontrib><creatorcontrib>Suelia de Siqueira Rodrigues Fleury Rosa</creatorcontrib><title>Infusion Pump: Mathematical Modeling Graphic Bond for Blood Pressure Control</title><title>Revista IEEE América Latina</title><description>This article presents a proposal for a mathematical modeling based on Bond Graph (BG) technique to simulate a continuous infusion pump. It presents a mathematical model that controls the infusion of medication to control the Mean Arterial Pressure (MAP), in which there should be a linear pattern and a very small error range in order to obtain the effectiveness of the procedure. For this, it uses dynamic modern control techniques knowledge of the mechanical parameters, for analyzing the pressure data and process control via an electronically controlled infusion pump. This study has two objectives: i) identification of the mathematical model of the infusion procedure by a bomb and ii) Fuzzy Controller. The contribution of this study is to present the mathematical model, with refinements based on prior knowledge of the phenomena involved and dynamic control analysis of the mathematical model with the use of fuzzy control.</description><subject>Blood pressure</subject><subject>Computer simulation</subject><subject>Dynamic control</subject><subject>Fuzzy control</subject><subject>Mathematical models</subject><subject>Mechanical properties</subject><issn>1548-0992</issn><issn>1548-0992</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNpNjcFPwyAcRonRxDm9eyTx3MqvQAvetsbNJV3cofcFCnVdOqhA_3-X6MHT9_IO70PoGUgOQORr26zygoDIBWMMONygBXAmMiJlcfuP79FDjGdCqCgFXaBm5_o5Dt7hw3yZ3vBepZO9qDR0asR7b-w4uC-8DWo6DR1ee2dw7wNej94bfAg2xjlYXHuXgh8f0V2vxmif_naJ2s17W39kzed2V6-abJIiZaIEygwQo7W1klBbUtC6A6FFp7UyvATFeFcofvW254xoqgWjxJSSVobRJXr5zU7Bf882puPZz8FdH48FQAWsIryiP-AFT2I</recordid><startdate>20180601</startdate><enddate>20180601</enddate><creator>Joziane Porcino da Silva</creator><creator>Beatriz Araujo Rodrigues</creator><creator>Jocyellen Christyne da Silva Casado</creator><creator>Suelia de Siqueira Rodrigues Fleury Rosa</creator><general>The Institute of Electrical and Electronics Engineers, Inc. (IEEE)</general><scope>7SC</scope><scope>7SP</scope><scope>8FD</scope><scope>JQ2</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope></search><sort><creationdate>20180601</creationdate><title>Infusion Pump: Mathematical Modeling Graphic Bond for Blood Pressure Control</title><author>Joziane Porcino da Silva ; Beatriz Araujo Rodrigues ; Jocyellen Christyne da Silva Casado ; Suelia de Siqueira Rodrigues Fleury Rosa</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p98t-86134d10dbbee903e631bbc18b8cbbad561a45c2a531bef540b3b8430d6937d43</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>por ; spa</language><creationdate>2018</creationdate><topic>Blood pressure</topic><topic>Computer simulation</topic><topic>Dynamic control</topic><topic>Fuzzy control</topic><topic>Mathematical models</topic><topic>Mechanical properties</topic><toplevel>online_resources</toplevel><creatorcontrib>Joziane Porcino da Silva</creatorcontrib><creatorcontrib>Beatriz Araujo Rodrigues</creatorcontrib><creatorcontrib>Jocyellen Christyne da Silva Casado</creatorcontrib><creatorcontrib>Suelia de Siqueira Rodrigues Fleury Rosa</creatorcontrib><collection>Computer and Information Systems Abstracts</collection><collection>Electronics & Communications Abstracts</collection><collection>Technology Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><jtitle>Revista IEEE América Latina</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Joziane Porcino da Silva</au><au>Beatriz Araujo Rodrigues</au><au>Jocyellen Christyne da Silva Casado</au><au>Suelia de Siqueira Rodrigues Fleury Rosa</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Infusion Pump: Mathematical Modeling Graphic Bond for Blood Pressure Control</atitle><jtitle>Revista IEEE América Latina</jtitle><date>2018-06-01</date><risdate>2018</risdate><volume>16</volume><issue>6</issue><spage>1569</spage><pages>1569-</pages><issn>1548-0992</issn><eissn>1548-0992</eissn><abstract>This article presents a proposal for a mathematical modeling based on Bond Graph (BG) technique to simulate a continuous infusion pump. It presents a mathematical model that controls the infusion of medication to control the Mean Arterial Pressure (MAP), in which there should be a linear pattern and a very small error range in order to obtain the effectiveness of the procedure. For this, it uses dynamic modern control techniques knowledge of the mechanical parameters, for analyzing the pressure data and process control via an electronically controlled infusion pump. This study has two objectives: i) identification of the mathematical model of the infusion procedure by a bomb and ii) Fuzzy Controller. The contribution of this study is to present the mathematical model, with refinements based on prior knowledge of the phenomena involved and dynamic control analysis of the mathematical model with the use of fuzzy control.</abstract><cop>Los Alamitos</cop><pub>The Institute of Electrical and Electronics Engineers, Inc. (IEEE)</pub><doi>10.1109/TLA.2018.8444151</doi></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1548-0992 |
ispartof | Revista IEEE América Latina, 2018-06, Vol.16 (6), p.1569 |
issn | 1548-0992 1548-0992 |
language | por ; spa |
recordid | cdi_proquest_journals_2117147057 |
source | IEEE Electronic Library (IEL) |
subjects | Blood pressure Computer simulation Dynamic control Fuzzy control Mathematical models Mechanical properties |
title | Infusion Pump: Mathematical Modeling Graphic Bond for Blood Pressure Control |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-01T05%3A20%3A52IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Infusion%20Pump:%20Mathematical%20Modeling%20Graphic%20Bond%20for%20Blood%20Pressure%20Control&rft.jtitle=Revista%20IEEE%20Am%C3%A9rica%20Latina&rft.au=Joziane%20Porcino%20da%20Silva&rft.date=2018-06-01&rft.volume=16&rft.issue=6&rft.spage=1569&rft.pages=1569-&rft.issn=1548-0992&rft.eissn=1548-0992&rft_id=info:doi/10.1109/TLA.2018.8444151&rft_dat=%3Cproquest%3E2117147057%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2117147057&rft_id=info:pmid/&rfr_iscdi=true |