Cs2AgBiBr6 single-crystal X-ray detectors with a low detection limit

Sensitive X-ray detection is crucial for medical diagnosis, industrial inspection and scientific research. The recently described hybrid lead halide perovskites have demonstrated low-cost fabrication and outstanding performance for direct X-ray detection, but they all contain toxic Pb in a soluble f...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Nature photonics 2017-11, Vol.11 (11), p.726-732
Hauptverfasser: Pan, Weicheng, Wu, Haodi, Luo, Jiajun, Deng, Zhenzhou, Ge, Cong, Chen, Chao, Jiang, Xiaowei, Yin, Wan-Jian, Niu, Guangda, Zhu, Lujun, Yin, Lixiao, Zhou, Ying, Xie, Qingguo, Ke, Xiaoxing, Sui, Manling, Tang, Jiang
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 732
container_issue 11
container_start_page 726
container_title Nature photonics
container_volume 11
creator Pan, Weicheng
Wu, Haodi
Luo, Jiajun
Deng, Zhenzhou
Ge, Cong
Chen, Chao
Jiang, Xiaowei
Yin, Wan-Jian
Niu, Guangda
Zhu, Lujun
Yin, Lixiao
Zhou, Ying
Xie, Qingguo
Ke, Xiaoxing
Sui, Manling
Tang, Jiang
description Sensitive X-ray detection is crucial for medical diagnosis, industrial inspection and scientific research. The recently described hybrid lead halide perovskites have demonstrated low-cost fabrication and outstanding performance for direct X-ray detection, but they all contain toxic Pb in a soluble form. Here, we report sensitive X-ray detectors using solution-processed double perovskite Cs 2 AgBiBr 6 single crystals. Through thermal annealing and surface treatment, we largely eliminate Ag + /Bi 3+ disordering and improve the crystal resistivity, resulting in a detector with a minimum detectable dose rate as low as 59.7 nGy air  s −1 , comparable to the latest record of 0.036 μGy air  s −1 using CH 3 NH 3 PbBr 3 single crystals. Suppressed ion migration in Cs 2 AgBiBr 6 permits relatively large external bias, guaranteeing efficient charge collection without a substantial increase in noise current and thus enabling the low detection limit. Double perovskite Cs 2 AgBiBr 6 single crystals are used to make a sensitive X-ray detector. The device exhibits a high sensitivity of 105 µC Gy air −1  cm −2 and a low detection limit of 59.7 nGy air s −1 , and demonstrates long-term operational stability.
doi_str_mv 10.1038/s41566-017-0012-4
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2115238876</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2115238876</sourcerecordid><originalsourceid>FETCH-LOGICAL-c344t-c45d0fc895fce50da704c2148708d4d6d7dbc5fdb4555c4fdef9d0053b7d9b723</originalsourceid><addsrcrecordid>eNp9kMFKAzEQhoMoWKsP4C3gOZpkJ5vk2FarQsGLgrewm2Trlu1uTVJK396tW8SLnmYYvn9m-BC6ZvSW0UzdRWAizwllklDKOIETNGISNAGls9OfXolzdBHjilKRac5H6H4W-WQ5rachx7Ful40nNuxjKhr8TkKxx84nb1MXIt7V6QMXuOl2x2Hdtbip13W6RGdV0UR_daxj9DZ_eJ09kcXL4_NssiA2A0jEgnC0skqLynpBXSEpWM5ASaocuNxJV1pRuRKEEBYq5yvtDp-W0ulS8myMboa9m9B9bn1MZtVtQ9ufNJwxwTOlZP4fxbRQHEB-U2ygbOhiDL4ym1Cvi7A3jJqDUjMoNb1Sc1BqoM_wIRN7tl368Gvzn6EvkC13qA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1958244776</pqid></control><display><type>article</type><title>Cs2AgBiBr6 single-crystal X-ray detectors with a low detection limit</title><source>Springer Nature - Complete Springer Journals</source><source>Nature Journals Online</source><creator>Pan, Weicheng ; Wu, Haodi ; Luo, Jiajun ; Deng, Zhenzhou ; Ge, Cong ; Chen, Chao ; Jiang, Xiaowei ; Yin, Wan-Jian ; Niu, Guangda ; Zhu, Lujun ; Yin, Lixiao ; Zhou, Ying ; Xie, Qingguo ; Ke, Xiaoxing ; Sui, Manling ; Tang, Jiang</creator><creatorcontrib>Pan, Weicheng ; Wu, Haodi ; Luo, Jiajun ; Deng, Zhenzhou ; Ge, Cong ; Chen, Chao ; Jiang, Xiaowei ; Yin, Wan-Jian ; Niu, Guangda ; Zhu, Lujun ; Yin, Lixiao ; Zhou, Ying ; Xie, Qingguo ; Ke, Xiaoxing ; Sui, Manling ; Tang, Jiang</creatorcontrib><description>Sensitive X-ray detection is crucial for medical diagnosis, industrial inspection and scientific research. The recently described hybrid lead halide perovskites have demonstrated low-cost fabrication and outstanding performance for direct X-ray detection, but they all contain toxic Pb in a soluble form. Here, we report sensitive X-ray detectors using solution-processed double perovskite Cs 2 AgBiBr 6 single crystals. Through thermal annealing and surface treatment, we largely eliminate Ag + /Bi 3+ disordering and improve the crystal resistivity, resulting in a detector with a minimum detectable dose rate as low as 59.7 nGy air  s −1 , comparable to the latest record of 0.036 μGy air  s −1 using CH 3 NH 3 PbBr 3 single crystals. Suppressed ion migration in Cs 2 AgBiBr 6 permits relatively large external bias, guaranteeing efficient charge collection without a substantial increase in noise current and thus enabling the low detection limit. Double perovskite Cs 2 AgBiBr 6 single crystals are used to make a sensitive X-ray detector. The device exhibits a high sensitivity of 105 µC Gy air −1  cm −2 and a low detection limit of 59.7 nGy air s −1 , and demonstrates long-term operational stability.</description><identifier>ISSN: 1749-4885</identifier><identifier>EISSN: 1749-4893</identifier><identifier>DOI: 10.1038/s41566-017-0012-4</identifier><language>eng</language><publisher>London: Nature Publishing Group UK</publisher><subject>639/301/1005/1009 ; 639/624/1075/401 ; Applied and Technical Physics ; Crystals ; Dosage ; Fabrication ; Heat treatment ; Inspection ; Lead ; Medical research ; Perovskites ; Physics ; Physics and Astronomy ; Quantum Physics ; Single crystals ; Surface treatment ; X ray detectors ; X-rays</subject><ispartof>Nature photonics, 2017-11, Vol.11 (11), p.726-732</ispartof><rights>The Author(s) 2017</rights><rights>Nature Photonics is a copyright of Springer, 2017.</rights><rights>Copyright Nature Publishing Group Nov 2017</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c344t-c45d0fc895fce50da704c2148708d4d6d7dbc5fdb4555c4fdef9d0053b7d9b723</citedby><cites>FETCH-LOGICAL-c344t-c45d0fc895fce50da704c2148708d4d6d7dbc5fdb4555c4fdef9d0053b7d9b723</cites><orcidid>0000-0003-2574-2943</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.1038/s41566-017-0012-4$$EPDF$$P50$$Gspringer$$H</linktopdf><linktohtml>$$Uhttps://link.springer.com/10.1038/s41566-017-0012-4$$EHTML$$P50$$Gspringer$$H</linktohtml><link.rule.ids>314,777,781,27905,27906,41469,42538,51300</link.rule.ids></links><search><creatorcontrib>Pan, Weicheng</creatorcontrib><creatorcontrib>Wu, Haodi</creatorcontrib><creatorcontrib>Luo, Jiajun</creatorcontrib><creatorcontrib>Deng, Zhenzhou</creatorcontrib><creatorcontrib>Ge, Cong</creatorcontrib><creatorcontrib>Chen, Chao</creatorcontrib><creatorcontrib>Jiang, Xiaowei</creatorcontrib><creatorcontrib>Yin, Wan-Jian</creatorcontrib><creatorcontrib>Niu, Guangda</creatorcontrib><creatorcontrib>Zhu, Lujun</creatorcontrib><creatorcontrib>Yin, Lixiao</creatorcontrib><creatorcontrib>Zhou, Ying</creatorcontrib><creatorcontrib>Xie, Qingguo</creatorcontrib><creatorcontrib>Ke, Xiaoxing</creatorcontrib><creatorcontrib>Sui, Manling</creatorcontrib><creatorcontrib>Tang, Jiang</creatorcontrib><title>Cs2AgBiBr6 single-crystal X-ray detectors with a low detection limit</title><title>Nature photonics</title><addtitle>Nature Photon</addtitle><description>Sensitive X-ray detection is crucial for medical diagnosis, industrial inspection and scientific research. The recently described hybrid lead halide perovskites have demonstrated low-cost fabrication and outstanding performance for direct X-ray detection, but they all contain toxic Pb in a soluble form. Here, we report sensitive X-ray detectors using solution-processed double perovskite Cs 2 AgBiBr 6 single crystals. Through thermal annealing and surface treatment, we largely eliminate Ag + /Bi 3+ disordering and improve the crystal resistivity, resulting in a detector with a minimum detectable dose rate as low as 59.7 nGy air  s −1 , comparable to the latest record of 0.036 μGy air  s −1 using CH 3 NH 3 PbBr 3 single crystals. Suppressed ion migration in Cs 2 AgBiBr 6 permits relatively large external bias, guaranteeing efficient charge collection without a substantial increase in noise current and thus enabling the low detection limit. Double perovskite Cs 2 AgBiBr 6 single crystals are used to make a sensitive X-ray detector. The device exhibits a high sensitivity of 105 µC Gy air −1  cm −2 and a low detection limit of 59.7 nGy air s −1 , and demonstrates long-term operational stability.</description><subject>639/301/1005/1009</subject><subject>639/624/1075/401</subject><subject>Applied and Technical Physics</subject><subject>Crystals</subject><subject>Dosage</subject><subject>Fabrication</subject><subject>Heat treatment</subject><subject>Inspection</subject><subject>Lead</subject><subject>Medical research</subject><subject>Perovskites</subject><subject>Physics</subject><subject>Physics and Astronomy</subject><subject>Quantum Physics</subject><subject>Single crystals</subject><subject>Surface treatment</subject><subject>X ray detectors</subject><subject>X-rays</subject><issn>1749-4885</issn><issn>1749-4893</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><sourceid>GNUQQ</sourceid><recordid>eNp9kMFKAzEQhoMoWKsP4C3gOZpkJ5vk2FarQsGLgrewm2Trlu1uTVJK396tW8SLnmYYvn9m-BC6ZvSW0UzdRWAizwllklDKOIETNGISNAGls9OfXolzdBHjilKRac5H6H4W-WQ5rachx7Ful40nNuxjKhr8TkKxx84nb1MXIt7V6QMXuOl2x2Hdtbip13W6RGdV0UR_daxj9DZ_eJ09kcXL4_NssiA2A0jEgnC0skqLynpBXSEpWM5ASaocuNxJV1pRuRKEEBYq5yvtDp-W0ulS8myMboa9m9B9bn1MZtVtQ9ufNJwxwTOlZP4fxbRQHEB-U2ygbOhiDL4ym1Cvi7A3jJqDUjMoNb1Sc1BqoM_wIRN7tl368Gvzn6EvkC13qA</recordid><startdate>20171101</startdate><enddate>20171101</enddate><creator>Pan, Weicheng</creator><creator>Wu, Haodi</creator><creator>Luo, Jiajun</creator><creator>Deng, Zhenzhou</creator><creator>Ge, Cong</creator><creator>Chen, Chao</creator><creator>Jiang, Xiaowei</creator><creator>Yin, Wan-Jian</creator><creator>Niu, Guangda</creator><creator>Zhu, Lujun</creator><creator>Yin, Lixiao</creator><creator>Zhou, Ying</creator><creator>Xie, Qingguo</creator><creator>Ke, Xiaoxing</creator><creator>Sui, Manling</creator><creator>Tang, Jiang</creator><general>Nature Publishing Group UK</general><general>Nature Publishing Group</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7QO</scope><scope>7SP</scope><scope>7U5</scope><scope>8FD</scope><scope>8FE</scope><scope>8FG</scope><scope>8FH</scope><scope>AEUYN</scope><scope>AFKRA</scope><scope>ARAPS</scope><scope>AZQEC</scope><scope>BBNVY</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>BHPHI</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FR3</scope><scope>GNUQQ</scope><scope>H8D</scope><scope>HCIFZ</scope><scope>L7M</scope><scope>LK8</scope><scope>M7P</scope><scope>P5Z</scope><scope>P62</scope><scope>P64</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><orcidid>https://orcid.org/0000-0003-2574-2943</orcidid></search><sort><creationdate>20171101</creationdate><title>Cs2AgBiBr6 single-crystal X-ray detectors with a low detection limit</title><author>Pan, Weicheng ; Wu, Haodi ; Luo, Jiajun ; Deng, Zhenzhou ; Ge, Cong ; Chen, Chao ; Jiang, Xiaowei ; Yin, Wan-Jian ; Niu, Guangda ; Zhu, Lujun ; Yin, Lixiao ; Zhou, Ying ; Xie, Qingguo ; Ke, Xiaoxing ; Sui, Manling ; Tang, Jiang</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c344t-c45d0fc895fce50da704c2148708d4d6d7dbc5fdb4555c4fdef9d0053b7d9b723</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>639/301/1005/1009</topic><topic>639/624/1075/401</topic><topic>Applied and Technical Physics</topic><topic>Crystals</topic><topic>Dosage</topic><topic>Fabrication</topic><topic>Heat treatment</topic><topic>Inspection</topic><topic>Lead</topic><topic>Medical research</topic><topic>Perovskites</topic><topic>Physics</topic><topic>Physics and Astronomy</topic><topic>Quantum Physics</topic><topic>Single crystals</topic><topic>Surface treatment</topic><topic>X ray detectors</topic><topic>X-rays</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Pan, Weicheng</creatorcontrib><creatorcontrib>Wu, Haodi</creatorcontrib><creatorcontrib>Luo, Jiajun</creatorcontrib><creatorcontrib>Deng, Zhenzhou</creatorcontrib><creatorcontrib>Ge, Cong</creatorcontrib><creatorcontrib>Chen, Chao</creatorcontrib><creatorcontrib>Jiang, Xiaowei</creatorcontrib><creatorcontrib>Yin, Wan-Jian</creatorcontrib><creatorcontrib>Niu, Guangda</creatorcontrib><creatorcontrib>Zhu, Lujun</creatorcontrib><creatorcontrib>Yin, Lixiao</creatorcontrib><creatorcontrib>Zhou, Ying</creatorcontrib><creatorcontrib>Xie, Qingguo</creatorcontrib><creatorcontrib>Ke, Xiaoxing</creatorcontrib><creatorcontrib>Sui, Manling</creatorcontrib><creatorcontrib>Tang, Jiang</creatorcontrib><collection>CrossRef</collection><collection>Biotechnology Research Abstracts</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>ProQuest Natural Science Collection</collection><collection>ProQuest One Sustainability</collection><collection>ProQuest Central UK/Ireland</collection><collection>Advanced Technologies &amp; Aerospace Collection</collection><collection>ProQuest Central Essentials</collection><collection>Biological Science Collection</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>Natural Science Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Engineering Research Database</collection><collection>ProQuest Central Student</collection><collection>Aerospace Database</collection><collection>SciTech Premium Collection</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>ProQuest Biological Science Collection</collection><collection>Biological Science Database</collection><collection>Advanced Technologies &amp; Aerospace Database</collection><collection>ProQuest Advanced Technologies &amp; Aerospace Collection</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><jtitle>Nature photonics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Pan, Weicheng</au><au>Wu, Haodi</au><au>Luo, Jiajun</au><au>Deng, Zhenzhou</au><au>Ge, Cong</au><au>Chen, Chao</au><au>Jiang, Xiaowei</au><au>Yin, Wan-Jian</au><au>Niu, Guangda</au><au>Zhu, Lujun</au><au>Yin, Lixiao</au><au>Zhou, Ying</au><au>Xie, Qingguo</au><au>Ke, Xiaoxing</au><au>Sui, Manling</au><au>Tang, Jiang</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Cs2AgBiBr6 single-crystal X-ray detectors with a low detection limit</atitle><jtitle>Nature photonics</jtitle><stitle>Nature Photon</stitle><date>2017-11-01</date><risdate>2017</risdate><volume>11</volume><issue>11</issue><spage>726</spage><epage>732</epage><pages>726-732</pages><issn>1749-4885</issn><eissn>1749-4893</eissn><abstract>Sensitive X-ray detection is crucial for medical diagnosis, industrial inspection and scientific research. The recently described hybrid lead halide perovskites have demonstrated low-cost fabrication and outstanding performance for direct X-ray detection, but they all contain toxic Pb in a soluble form. Here, we report sensitive X-ray detectors using solution-processed double perovskite Cs 2 AgBiBr 6 single crystals. Through thermal annealing and surface treatment, we largely eliminate Ag + /Bi 3+ disordering and improve the crystal resistivity, resulting in a detector with a minimum detectable dose rate as low as 59.7 nGy air  s −1 , comparable to the latest record of 0.036 μGy air  s −1 using CH 3 NH 3 PbBr 3 single crystals. Suppressed ion migration in Cs 2 AgBiBr 6 permits relatively large external bias, guaranteeing efficient charge collection without a substantial increase in noise current and thus enabling the low detection limit. Double perovskite Cs 2 AgBiBr 6 single crystals are used to make a sensitive X-ray detector. The device exhibits a high sensitivity of 105 µC Gy air −1  cm −2 and a low detection limit of 59.7 nGy air s −1 , and demonstrates long-term operational stability.</abstract><cop>London</cop><pub>Nature Publishing Group UK</pub><doi>10.1038/s41566-017-0012-4</doi><tpages>7</tpages><orcidid>https://orcid.org/0000-0003-2574-2943</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 1749-4885
ispartof Nature photonics, 2017-11, Vol.11 (11), p.726-732
issn 1749-4885
1749-4893
language eng
recordid cdi_proquest_journals_2115238876
source Springer Nature - Complete Springer Journals; Nature Journals Online
subjects 639/301/1005/1009
639/624/1075/401
Applied and Technical Physics
Crystals
Dosage
Fabrication
Heat treatment
Inspection
Lead
Medical research
Perovskites
Physics
Physics and Astronomy
Quantum Physics
Single crystals
Surface treatment
X ray detectors
X-rays
title Cs2AgBiBr6 single-crystal X-ray detectors with a low detection limit
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-21T02%3A34%3A03IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Cs2AgBiBr6%20single-crystal%20X-ray%20detectors%20with%20a%20low%20detection%20limit&rft.jtitle=Nature%20photonics&rft.au=Pan,%20Weicheng&rft.date=2017-11-01&rft.volume=11&rft.issue=11&rft.spage=726&rft.epage=732&rft.pages=726-732&rft.issn=1749-4885&rft.eissn=1749-4893&rft_id=info:doi/10.1038/s41566-017-0012-4&rft_dat=%3Cproquest_cross%3E2115238876%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1958244776&rft_id=info:pmid/&rfr_iscdi=true