A stability-indicating capillary electrophoresis method for the determination of emtricitabine and tenofovir disoproxil fumarate in pharmaceutical tablets

A stability-indicating capillary electrophoresis method coupled to a diode array detector (DAD) was developed and validated for the simultaneous determination of emtricitabine (FTC) and tenofovir disoproxil fumarate (TDF) in combined tablets. This proposed method utilized a fused silica capillary (e...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Acta Chromatographica 2017-12, Vol.29 (4), p.469-476
Hauptverfasser: Al-Johar, Haya I, Maher, Hadir M, Al-Zoman, Nourah Z, Al-Shammary, Dlayel J, Al-Showiman, Hessa
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 476
container_issue 4
container_start_page 469
container_title Acta Chromatographica
container_volume 29
creator Al-Johar, Haya I
Maher, Hadir M
Al-Zoman, Nourah Z
Al-Shammary, Dlayel J
Al-Showiman, Hessa
description A stability-indicating capillary electrophoresis method coupled to a diode array detector (DAD) was developed and validated for the simultaneous determination of emtricitabine (FTC) and tenofovir disoproxil fumarate (TDF) in combined tablets. This proposed method utilized a fused silica capillary (effective length, 62 cm; internal diameter [ID], 75 μm) and a background electrolyte (BGE) consisting of phosphate solution (pH 9.5, 50 mM). The separation was achieved at a voltage of 25 kV and a temperature of 21 °C using paracetamol as an internal standard. The described method was linear over the range of 5–200 μg/mL for both drugs ( r = 0.9992). Intra- and inter-day relative standard deviation (RSD) ( n = 9) was 0.41%. The limits of detection for FTC and TDF were 1.25 and 1.00 μg/mL, respectively. The average percentage recoveries of FTC and TDF from their tablet formulations were 99.66 ± 0.73 and 99.48 ± 0.33, respectively. The two drugs were subjected to thermal, photolytic, hydrolytic, and oxidative stress conditions, and then the stressed samples were analyzed by the proposed method. Degradation products produced as a result of stress studies did not interfere with the detection of FTC and TDF. The assay can thus be considered stability indicating.
doi_str_mv 10.1556/1326.2017.00057
format Article
fullrecord <record><control><sourceid>gale_proqu</sourceid><recordid>TN_cdi_proquest_journals_2114672620</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A518802253</galeid><sourcerecordid>A518802253</sourcerecordid><originalsourceid>FETCH-LOGICAL-c307t-e5a619aaf792741163e50824872937f1b961360811e4aa13742ed611e98c8e6b3</originalsourceid><addsrcrecordid>eNptUUuLFDEQbkTBdfXsNeC5Z_PoPPo4LL5gwYueQyZd2aklnbRJRpy_4q814woqSB3qwfd9VdQ3DK8Z3TEp1Q0TXO04ZXpHKZX6yXDFqRGj1EI9_at-Pryo9YFSLqfJXA0_9qQ2d8CI7TxiWtC7humeeLdhjK6cCUTwreTtmAtUrGSFdswLCbmQdgSyQIOyYuq0nEgOBNZW0ONFNAFxaSENUg75GxayYM1byd8xknBaXXENCCayHV1ZnYdT6-sj6dQIrb4cngUXK7z6na-HL-_efr79MN59ev_xdn83ekF1G0E6xWbngp65nhhTAiQ1fDKaz0IHdpgVE4oaxmByjgk9cVhU72bjDaiDuB7ePOr2y76eoDb7kE8l9ZWWMzYpzRWnf1D3LoLFFHIrzq9Yvd1LZgzlXIqO2v0H1WOBFX1OELDP_yHcPBJ8ybUWCHYr2D9ztozai6_24qu9-Gp_-Sp-AurClsU</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2114672620</pqid></control><display><type>article</type><title>A stability-indicating capillary electrophoresis method for the determination of emtricitabine and tenofovir disoproxil fumarate in pharmaceutical tablets</title><source>EZB-FREE-00999 freely available EZB journals</source><creator>Al-Johar, Haya I ; Maher, Hadir M ; Al-Zoman, Nourah Z ; Al-Shammary, Dlayel J ; Al-Showiman, Hessa</creator><creatorcontrib>Al-Johar, Haya I ; Maher, Hadir M ; Al-Zoman, Nourah Z ; Al-Shammary, Dlayel J ; Al-Showiman, Hessa</creatorcontrib><description>A stability-indicating capillary electrophoresis method coupled to a diode array detector (DAD) was developed and validated for the simultaneous determination of emtricitabine (FTC) and tenofovir disoproxil fumarate (TDF) in combined tablets. This proposed method utilized a fused silica capillary (effective length, 62 cm; internal diameter [ID], 75 μm) and a background electrolyte (BGE) consisting of phosphate solution (pH 9.5, 50 mM). The separation was achieved at a voltage of 25 kV and a temperature of 21 °C using paracetamol as an internal standard. The described method was linear over the range of 5–200 μg/mL for both drugs ( r = 0.9992). Intra- and inter-day relative standard deviation (RSD) ( n = 9) was 0.41%. The limits of detection for FTC and TDF were 1.25 and 1.00 μg/mL, respectively. The average percentage recoveries of FTC and TDF from their tablet formulations were 99.66 ± 0.73 and 99.48 ± 0.33, respectively. The two drugs were subjected to thermal, photolytic, hydrolytic, and oxidative stress conditions, and then the stressed samples were analyzed by the proposed method. Degradation products produced as a result of stress studies did not interfere with the detection of FTC and TDF. The assay can thus be considered stability indicating.</description><identifier>ISSN: 2083-5736</identifier><identifier>ISSN: 1233-2356</identifier><identifier>EISSN: 2083-5736</identifier><identifier>DOI: 10.1556/1326.2017.00057</identifier><language>eng</language><publisher>Budapest: Akademiai Kiado</publisher><subject>Capillary electrophoresis ; Degradation products ; Drugs ; Electrophoresis ; Emtricitabine ; Formulations ; Fused silica ; Methods ; Observations ; Oxidative stress ; Paracetamol ; Silica ; Silicon dioxide ; Stability ; Tablets ; Tenofovir</subject><ispartof>Acta Chromatographica, 2017-12, Vol.29 (4), p.469-476</ispartof><rights>COPYRIGHT 2017 Akademiai Kiado</rights><rights>Copyright Akademiai Kiado Zrt Dec 2017</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c307t-e5a619aaf792741163e50824872937f1b961360811e4aa13742ed611e98c8e6b3</citedby><cites>FETCH-LOGICAL-c307t-e5a619aaf792741163e50824872937f1b961360811e4aa13742ed611e98c8e6b3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids></links><search><creatorcontrib>Al-Johar, Haya I</creatorcontrib><creatorcontrib>Maher, Hadir M</creatorcontrib><creatorcontrib>Al-Zoman, Nourah Z</creatorcontrib><creatorcontrib>Al-Shammary, Dlayel J</creatorcontrib><creatorcontrib>Al-Showiman, Hessa</creatorcontrib><title>A stability-indicating capillary electrophoresis method for the determination of emtricitabine and tenofovir disoproxil fumarate in pharmaceutical tablets</title><title>Acta Chromatographica</title><description>A stability-indicating capillary electrophoresis method coupled to a diode array detector (DAD) was developed and validated for the simultaneous determination of emtricitabine (FTC) and tenofovir disoproxil fumarate (TDF) in combined tablets. This proposed method utilized a fused silica capillary (effective length, 62 cm; internal diameter [ID], 75 μm) and a background electrolyte (BGE) consisting of phosphate solution (pH 9.5, 50 mM). The separation was achieved at a voltage of 25 kV and a temperature of 21 °C using paracetamol as an internal standard. The described method was linear over the range of 5–200 μg/mL for both drugs ( r = 0.9992). Intra- and inter-day relative standard deviation (RSD) ( n = 9) was 0.41%. The limits of detection for FTC and TDF were 1.25 and 1.00 μg/mL, respectively. The average percentage recoveries of FTC and TDF from their tablet formulations were 99.66 ± 0.73 and 99.48 ± 0.33, respectively. The two drugs were subjected to thermal, photolytic, hydrolytic, and oxidative stress conditions, and then the stressed samples were analyzed by the proposed method. Degradation products produced as a result of stress studies did not interfere with the detection of FTC and TDF. The assay can thus be considered stability indicating.</description><subject>Capillary electrophoresis</subject><subject>Degradation products</subject><subject>Drugs</subject><subject>Electrophoresis</subject><subject>Emtricitabine</subject><subject>Formulations</subject><subject>Fused silica</subject><subject>Methods</subject><subject>Observations</subject><subject>Oxidative stress</subject><subject>Paracetamol</subject><subject>Silica</subject><subject>Silicon dioxide</subject><subject>Stability</subject><subject>Tablets</subject><subject>Tenofovir</subject><issn>2083-5736</issn><issn>1233-2356</issn><issn>2083-5736</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><recordid>eNptUUuLFDEQbkTBdfXsNeC5Z_PoPPo4LL5gwYueQyZd2aklnbRJRpy_4q814woqSB3qwfd9VdQ3DK8Z3TEp1Q0TXO04ZXpHKZX6yXDFqRGj1EI9_at-Pryo9YFSLqfJXA0_9qQ2d8CI7TxiWtC7humeeLdhjK6cCUTwreTtmAtUrGSFdswLCbmQdgSyQIOyYuq0nEgOBNZW0ONFNAFxaSENUg75GxayYM1byd8xknBaXXENCCayHV1ZnYdT6-sj6dQIrb4cngUXK7z6na-HL-_efr79MN59ev_xdn83ekF1G0E6xWbngp65nhhTAiQ1fDKaz0IHdpgVE4oaxmByjgk9cVhU72bjDaiDuB7ePOr2y76eoDb7kE8l9ZWWMzYpzRWnf1D3LoLFFHIrzq9Yvd1LZgzlXIqO2v0H1WOBFX1OELDP_yHcPBJ8ybUWCHYr2D9ztozai6_24qu9-Gp_-Sp-AurClsU</recordid><startdate>20171201</startdate><enddate>20171201</enddate><creator>Al-Johar, Haya I</creator><creator>Maher, Hadir M</creator><creator>Al-Zoman, Nourah Z</creator><creator>Al-Shammary, Dlayel J</creator><creator>Al-Showiman, Hessa</creator><general>Akademiai Kiado</general><general>Akademiai Kiado Zrt</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7QO</scope><scope>8FD</scope><scope>FR3</scope><scope>P64</scope></search><sort><creationdate>20171201</creationdate><title>A stability-indicating capillary electrophoresis method for the determination of emtricitabine and tenofovir disoproxil fumarate in pharmaceutical tablets</title><author>Al-Johar, Haya I ; Maher, Hadir M ; Al-Zoman, Nourah Z ; Al-Shammary, Dlayel J ; Al-Showiman, Hessa</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c307t-e5a619aaf792741163e50824872937f1b961360811e4aa13742ed611e98c8e6b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Capillary electrophoresis</topic><topic>Degradation products</topic><topic>Drugs</topic><topic>Electrophoresis</topic><topic>Emtricitabine</topic><topic>Formulations</topic><topic>Fused silica</topic><topic>Methods</topic><topic>Observations</topic><topic>Oxidative stress</topic><topic>Paracetamol</topic><topic>Silica</topic><topic>Silicon dioxide</topic><topic>Stability</topic><topic>Tablets</topic><topic>Tenofovir</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Al-Johar, Haya I</creatorcontrib><creatorcontrib>Maher, Hadir M</creatorcontrib><creatorcontrib>Al-Zoman, Nourah Z</creatorcontrib><creatorcontrib>Al-Shammary, Dlayel J</creatorcontrib><creatorcontrib>Al-Showiman, Hessa</creatorcontrib><collection>CrossRef</collection><collection>Biotechnology Research Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><jtitle>Acta Chromatographica</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Al-Johar, Haya I</au><au>Maher, Hadir M</au><au>Al-Zoman, Nourah Z</au><au>Al-Shammary, Dlayel J</au><au>Al-Showiman, Hessa</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A stability-indicating capillary electrophoresis method for the determination of emtricitabine and tenofovir disoproxil fumarate in pharmaceutical tablets</atitle><jtitle>Acta Chromatographica</jtitle><date>2017-12-01</date><risdate>2017</risdate><volume>29</volume><issue>4</issue><spage>469</spage><epage>476</epage><pages>469-476</pages><issn>2083-5736</issn><issn>1233-2356</issn><eissn>2083-5736</eissn><abstract>A stability-indicating capillary electrophoresis method coupled to a diode array detector (DAD) was developed and validated for the simultaneous determination of emtricitabine (FTC) and tenofovir disoproxil fumarate (TDF) in combined tablets. This proposed method utilized a fused silica capillary (effective length, 62 cm; internal diameter [ID], 75 μm) and a background electrolyte (BGE) consisting of phosphate solution (pH 9.5, 50 mM). The separation was achieved at a voltage of 25 kV and a temperature of 21 °C using paracetamol as an internal standard. The described method was linear over the range of 5–200 μg/mL for both drugs ( r = 0.9992). Intra- and inter-day relative standard deviation (RSD) ( n = 9) was 0.41%. The limits of detection for FTC and TDF were 1.25 and 1.00 μg/mL, respectively. The average percentage recoveries of FTC and TDF from their tablet formulations were 99.66 ± 0.73 and 99.48 ± 0.33, respectively. The two drugs were subjected to thermal, photolytic, hydrolytic, and oxidative stress conditions, and then the stressed samples were analyzed by the proposed method. Degradation products produced as a result of stress studies did not interfere with the detection of FTC and TDF. The assay can thus be considered stability indicating.</abstract><cop>Budapest</cop><pub>Akademiai Kiado</pub><doi>10.1556/1326.2017.00057</doi><tpages>8</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2083-5736
ispartof Acta Chromatographica, 2017-12, Vol.29 (4), p.469-476
issn 2083-5736
1233-2356
2083-5736
language eng
recordid cdi_proquest_journals_2114672620
source EZB-FREE-00999 freely available EZB journals
subjects Capillary electrophoresis
Degradation products
Drugs
Electrophoresis
Emtricitabine
Formulations
Fused silica
Methods
Observations
Oxidative stress
Paracetamol
Silica
Silicon dioxide
Stability
Tablets
Tenofovir
title A stability-indicating capillary electrophoresis method for the determination of emtricitabine and tenofovir disoproxil fumarate in pharmaceutical tablets
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-12T11%3A20%3A22IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale_proqu&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20stability-indicating%20capillary%20electrophoresis%20method%20for%20the%20determination%20of%20emtricitabine%20and%20tenofovir%20disoproxil%20fumarate%20in%20pharmaceutical%20tablets&rft.jtitle=Acta%20Chromatographica&rft.au=Al-Johar,%20Haya%20I&rft.date=2017-12-01&rft.volume=29&rft.issue=4&rft.spage=469&rft.epage=476&rft.pages=469-476&rft.issn=2083-5736&rft.eissn=2083-5736&rft_id=info:doi/10.1556/1326.2017.00057&rft_dat=%3Cgale_proqu%3EA518802253%3C/gale_proqu%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2114672620&rft_id=info:pmid/&rft_galeid=A518802253&rfr_iscdi=true