Molecularly imprinted electrochemical sensor prepared on a screen printed carbon electrode for naloxone detection
•First report on the preparation of a MIP-sensor for the determination of Naloxone.•Naloxone determination directly in the samples (diluted) without pre-treatment step.•The sensor is simple to fabricate, easy to operate and shows good performance. Naloxone (NLX) is a pharmaceutical used as opioid an...
Gespeichert in:
Veröffentlicht in: | Sensors and actuators. B, Chemical Chemical, 2017-05, Vol.243, p.745-752 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 752 |
---|---|
container_issue | |
container_start_page | 745 |
container_title | Sensors and actuators. B, Chemical |
container_volume | 243 |
creator | Lopes, Frederico Pacheco, João G. Rebelo, Patrícia Delerue-Matos, Cristina |
description | •First report on the preparation of a MIP-sensor for the determination of Naloxone.•Naloxone determination directly in the samples (diluted) without pre-treatment step.•The sensor is simple to fabricate, easy to operate and shows good performance.
Naloxone (NLX) is a pharmaceutical used as opioid antagonist. A molecular imprinted polymer electrochemical sensor for simple and rapid detection of NLX was prepared through the modification of commercial available screen printed carbon electrode (SPCE). The SPCE was modified with multi-walled carbon nanotubes (MWCNT) by drop coating to increase the signal response and improve the sensitivity. The MIP preparation was carried out via in situ electropolymerization using 4-aminobenzoic acid (4-ABA) as functional monomer. The morphology of the obtained sensor was characterized by scanning electron microscopy (SEM). Several parameters controlling the preparation and performance of the MIP sensor were studied and optimized. The electrochemical behavior of NLX at MIP and control non-imprinted (NIP) sensor was evaluated by differential pulse voltammetry (DPV), demonstrating a better MIP response and the success of the imprinting. The proposed MIP/MWCNT/SPCE sensor showed a linear relationship between peak current intensity and NLX concentration in the range between 0.25 and 10.0μM, with limits of detection (LOD) and quantification (LOQ) of 0.20μM and 0.67μM respectively. The repeatability and reproducibility were also tested with relative standard deviations (RSD) of 4.6 and 9.6% respectively. Moreover, the applicability of the method was successfully confirmed with detection of NLX in biological samples (urine and human serum). The sensor is promising to be used for screening NLX in point-of-care people with opioid overdose. |
doi_str_mv | 10.1016/j.snb.2016.12.031 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2098784468</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0925400516319931</els_id><sourcerecordid>2098784468</sourcerecordid><originalsourceid>FETCH-LOGICAL-c397t-93543179a9d3de94c4b4f16edddd0f3d9eefd42e41c505ad7dd1f022d9aa77d83</originalsourceid><addsrcrecordid>eNp9kE1LAzEQhoMoWKs_wFvA86752s0GT1L8gooXPYc0mcUs26RNtqL_3pTWq3OZ4Z15hpkXoWtKakpoezvUOaxqVsqasppweoJmtJO84kTKUzQjijWVIKQ5Rxc5D4QQwVsyQ9vXOILdjSaNP9ivN8mHCRyGIk4p2k9Ye2tGnCHkmPAmwcak0o8BG5xtAgj4j7EmrYp-RB3gvhDBjPE7BsAOpqL7GC7RWW_GDFfHPEcfjw_vi-dq-fb0srhfVpYrOVWKN4JTqYxy3IESVqxET1twJUjPnQLonWAgqG1IY5x0jvaEMaeMkdJ1fI5uDns3KW53kCc9xF0q92TNiOpkJ0S7n6KHKZtizgl6Xd5Zm_SjKdF7Z_Wgi7N676ymTBdnC3N3YKCc_-Uh6Ww9BAvOp_KjdtH_Q_8C7n-EWA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2098784468</pqid></control><display><type>article</type><title>Molecularly imprinted electrochemical sensor prepared on a screen printed carbon electrode for naloxone detection</title><source>Elsevier ScienceDirect Journals</source><creator>Lopes, Frederico ; Pacheco, João G. ; Rebelo, Patrícia ; Delerue-Matos, Cristina</creator><creatorcontrib>Lopes, Frederico ; Pacheco, João G. ; Rebelo, Patrícia ; Delerue-Matos, Cristina</creatorcontrib><description>•First report on the preparation of a MIP-sensor for the determination of Naloxone.•Naloxone determination directly in the samples (diluted) without pre-treatment step.•The sensor is simple to fabricate, easy to operate and shows good performance.
Naloxone (NLX) is a pharmaceutical used as opioid antagonist. A molecular imprinted polymer electrochemical sensor for simple and rapid detection of NLX was prepared through the modification of commercial available screen printed carbon electrode (SPCE). The SPCE was modified with multi-walled carbon nanotubes (MWCNT) by drop coating to increase the signal response and improve the sensitivity. The MIP preparation was carried out via in situ electropolymerization using 4-aminobenzoic acid (4-ABA) as functional monomer. The morphology of the obtained sensor was characterized by scanning electron microscopy (SEM). Several parameters controlling the preparation and performance of the MIP sensor were studied and optimized. The electrochemical behavior of NLX at MIP and control non-imprinted (NIP) sensor was evaluated by differential pulse voltammetry (DPV), demonstrating a better MIP response and the success of the imprinting. The proposed MIP/MWCNT/SPCE sensor showed a linear relationship between peak current intensity and NLX concentration in the range between 0.25 and 10.0μM, with limits of detection (LOD) and quantification (LOQ) of 0.20μM and 0.67μM respectively. The repeatability and reproducibility were also tested with relative standard deviations (RSD) of 4.6 and 9.6% respectively. Moreover, the applicability of the method was successfully confirmed with detection of NLX in biological samples (urine and human serum). The sensor is promising to be used for screening NLX in point-of-care people with opioid overdose.</description><identifier>ISSN: 0925-4005</identifier><identifier>EISSN: 1873-3077</identifier><identifier>DOI: 10.1016/j.snb.2016.12.031</identifier><language>eng</language><publisher>Lausanne: Elsevier B.V</publisher><subject>Biological properties ; Carbon ; Chemical sensors ; Electrochemical analysis ; Electrochemical sensor ; Electrodes ; Molecular imprinting ; Molecularly imprinted polymer ; Morphology ; Multi wall carbon nanotubes ; Multi-walled carbon nanotubes ; Naloxone ; Nanotubes ; Polymerization ; Polymers ; Reproducibility ; Scanning electron microscopy ; Screen printed electrode ; Sensors ; Urine</subject><ispartof>Sensors and actuators. B, Chemical, 2017-05, Vol.243, p.745-752</ispartof><rights>2016 Elsevier B.V.</rights><rights>Copyright Elsevier Science Ltd. May 2017</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c397t-93543179a9d3de94c4b4f16edddd0f3d9eefd42e41c505ad7dd1f022d9aa77d83</citedby><cites>FETCH-LOGICAL-c397t-93543179a9d3de94c4b4f16edddd0f3d9eefd42e41c505ad7dd1f022d9aa77d83</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0925400516319931$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids></links><search><creatorcontrib>Lopes, Frederico</creatorcontrib><creatorcontrib>Pacheco, João G.</creatorcontrib><creatorcontrib>Rebelo, Patrícia</creatorcontrib><creatorcontrib>Delerue-Matos, Cristina</creatorcontrib><title>Molecularly imprinted electrochemical sensor prepared on a screen printed carbon electrode for naloxone detection</title><title>Sensors and actuators. B, Chemical</title><description>•First report on the preparation of a MIP-sensor for the determination of Naloxone.•Naloxone determination directly in the samples (diluted) without pre-treatment step.•The sensor is simple to fabricate, easy to operate and shows good performance.
Naloxone (NLX) is a pharmaceutical used as opioid antagonist. A molecular imprinted polymer electrochemical sensor for simple and rapid detection of NLX was prepared through the modification of commercial available screen printed carbon electrode (SPCE). The SPCE was modified with multi-walled carbon nanotubes (MWCNT) by drop coating to increase the signal response and improve the sensitivity. The MIP preparation was carried out via in situ electropolymerization using 4-aminobenzoic acid (4-ABA) as functional monomer. The morphology of the obtained sensor was characterized by scanning electron microscopy (SEM). Several parameters controlling the preparation and performance of the MIP sensor were studied and optimized. The electrochemical behavior of NLX at MIP and control non-imprinted (NIP) sensor was evaluated by differential pulse voltammetry (DPV), demonstrating a better MIP response and the success of the imprinting. The proposed MIP/MWCNT/SPCE sensor showed a linear relationship between peak current intensity and NLX concentration in the range between 0.25 and 10.0μM, with limits of detection (LOD) and quantification (LOQ) of 0.20μM and 0.67μM respectively. The repeatability and reproducibility were also tested with relative standard deviations (RSD) of 4.6 and 9.6% respectively. Moreover, the applicability of the method was successfully confirmed with detection of NLX in biological samples (urine and human serum). The sensor is promising to be used for screening NLX in point-of-care people with opioid overdose.</description><subject>Biological properties</subject><subject>Carbon</subject><subject>Chemical sensors</subject><subject>Electrochemical analysis</subject><subject>Electrochemical sensor</subject><subject>Electrodes</subject><subject>Molecular imprinting</subject><subject>Molecularly imprinted polymer</subject><subject>Morphology</subject><subject>Multi wall carbon nanotubes</subject><subject>Multi-walled carbon nanotubes</subject><subject>Naloxone</subject><subject>Nanotubes</subject><subject>Polymerization</subject><subject>Polymers</subject><subject>Reproducibility</subject><subject>Scanning electron microscopy</subject><subject>Screen printed electrode</subject><subject>Sensors</subject><subject>Urine</subject><issn>0925-4005</issn><issn>1873-3077</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><recordid>eNp9kE1LAzEQhoMoWKs_wFvA86752s0GT1L8gooXPYc0mcUs26RNtqL_3pTWq3OZ4Z15hpkXoWtKakpoezvUOaxqVsqasppweoJmtJO84kTKUzQjijWVIKQ5Rxc5D4QQwVsyQ9vXOILdjSaNP9ivN8mHCRyGIk4p2k9Ye2tGnCHkmPAmwcak0o8BG5xtAgj4j7EmrYp-RB3gvhDBjPE7BsAOpqL7GC7RWW_GDFfHPEcfjw_vi-dq-fb0srhfVpYrOVWKN4JTqYxy3IESVqxET1twJUjPnQLonWAgqG1IY5x0jvaEMaeMkdJ1fI5uDns3KW53kCc9xF0q92TNiOpkJ0S7n6KHKZtizgl6Xd5Zm_SjKdF7Z_Wgi7N676ymTBdnC3N3YKCc_-Uh6Ww9BAvOp_KjdtH_Q_8C7n-EWA</recordid><startdate>20170501</startdate><enddate>20170501</enddate><creator>Lopes, Frederico</creator><creator>Pacheco, João G.</creator><creator>Rebelo, Patrícia</creator><creator>Delerue-Matos, Cristina</creator><general>Elsevier B.V</general><general>Elsevier Science Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>7SR</scope><scope>7TB</scope><scope>7U5</scope><scope>8BQ</scope><scope>8FD</scope><scope>FR3</scope><scope>JG9</scope><scope>L7M</scope></search><sort><creationdate>20170501</creationdate><title>Molecularly imprinted electrochemical sensor prepared on a screen printed carbon electrode for naloxone detection</title><author>Lopes, Frederico ; Pacheco, João G. ; Rebelo, Patrícia ; Delerue-Matos, Cristina</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c397t-93543179a9d3de94c4b4f16edddd0f3d9eefd42e41c505ad7dd1f022d9aa77d83</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Biological properties</topic><topic>Carbon</topic><topic>Chemical sensors</topic><topic>Electrochemical analysis</topic><topic>Electrochemical sensor</topic><topic>Electrodes</topic><topic>Molecular imprinting</topic><topic>Molecularly imprinted polymer</topic><topic>Morphology</topic><topic>Multi wall carbon nanotubes</topic><topic>Multi-walled carbon nanotubes</topic><topic>Naloxone</topic><topic>Nanotubes</topic><topic>Polymerization</topic><topic>Polymers</topic><topic>Reproducibility</topic><topic>Scanning electron microscopy</topic><topic>Screen printed electrode</topic><topic>Sensors</topic><topic>Urine</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Lopes, Frederico</creatorcontrib><creatorcontrib>Pacheco, João G.</creatorcontrib><creatorcontrib>Rebelo, Patrícia</creatorcontrib><creatorcontrib>Delerue-Matos, Cristina</creatorcontrib><collection>CrossRef</collection><collection>Electronics & Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Materials Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Sensors and actuators. B, Chemical</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Lopes, Frederico</au><au>Pacheco, João G.</au><au>Rebelo, Patrícia</au><au>Delerue-Matos, Cristina</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Molecularly imprinted electrochemical sensor prepared on a screen printed carbon electrode for naloxone detection</atitle><jtitle>Sensors and actuators. B, Chemical</jtitle><date>2017-05-01</date><risdate>2017</risdate><volume>243</volume><spage>745</spage><epage>752</epage><pages>745-752</pages><issn>0925-4005</issn><eissn>1873-3077</eissn><abstract>•First report on the preparation of a MIP-sensor for the determination of Naloxone.•Naloxone determination directly in the samples (diluted) without pre-treatment step.•The sensor is simple to fabricate, easy to operate and shows good performance.
Naloxone (NLX) is a pharmaceutical used as opioid antagonist. A molecular imprinted polymer electrochemical sensor for simple and rapid detection of NLX was prepared through the modification of commercial available screen printed carbon electrode (SPCE). The SPCE was modified with multi-walled carbon nanotubes (MWCNT) by drop coating to increase the signal response and improve the sensitivity. The MIP preparation was carried out via in situ electropolymerization using 4-aminobenzoic acid (4-ABA) as functional monomer. The morphology of the obtained sensor was characterized by scanning electron microscopy (SEM). Several parameters controlling the preparation and performance of the MIP sensor were studied and optimized. The electrochemical behavior of NLX at MIP and control non-imprinted (NIP) sensor was evaluated by differential pulse voltammetry (DPV), demonstrating a better MIP response and the success of the imprinting. The proposed MIP/MWCNT/SPCE sensor showed a linear relationship between peak current intensity and NLX concentration in the range between 0.25 and 10.0μM, with limits of detection (LOD) and quantification (LOQ) of 0.20μM and 0.67μM respectively. The repeatability and reproducibility were also tested with relative standard deviations (RSD) of 4.6 and 9.6% respectively. Moreover, the applicability of the method was successfully confirmed with detection of NLX in biological samples (urine and human serum). The sensor is promising to be used for screening NLX in point-of-care people with opioid overdose.</abstract><cop>Lausanne</cop><pub>Elsevier B.V</pub><doi>10.1016/j.snb.2016.12.031</doi><tpages>8</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0925-4005 |
ispartof | Sensors and actuators. B, Chemical, 2017-05, Vol.243, p.745-752 |
issn | 0925-4005 1873-3077 |
language | eng |
recordid | cdi_proquest_journals_2098784468 |
source | Elsevier ScienceDirect Journals |
subjects | Biological properties Carbon Chemical sensors Electrochemical analysis Electrochemical sensor Electrodes Molecular imprinting Molecularly imprinted polymer Morphology Multi wall carbon nanotubes Multi-walled carbon nanotubes Naloxone Nanotubes Polymerization Polymers Reproducibility Scanning electron microscopy Screen printed electrode Sensors Urine |
title | Molecularly imprinted electrochemical sensor prepared on a screen printed carbon electrode for naloxone detection |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-03T08%3A19%3A10IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Molecularly%20imprinted%20electrochemical%20sensor%20prepared%20on%20a%20screen%20printed%20carbon%20electrode%20for%20naloxone%20detection&rft.jtitle=Sensors%20and%20actuators.%20B,%20Chemical&rft.au=Lopes,%20Frederico&rft.date=2017-05-01&rft.volume=243&rft.spage=745&rft.epage=752&rft.pages=745-752&rft.issn=0925-4005&rft.eissn=1873-3077&rft_id=info:doi/10.1016/j.snb.2016.12.031&rft_dat=%3Cproquest_cross%3E2098784468%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2098784468&rft_id=info:pmid/&rft_els_id=S0925400516319931&rfr_iscdi=true |