A portable electrochemical method for cocaine quantification and rapid screening of common adulterants in seized samples

[Display omitted] •The electrochemical oxidation of cocaine in acid media is proposed for the first time.•Excellent selectivity for cocaine quantification.•Two methods for fast screening of common adulterants in cocaine seized samples.•Minimal sample manipulation (dissolution in electrolyte). A simp...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Sensors and actuators. B, Chemical Chemical, 2017-05, Vol.243, p.557-565
Hauptverfasser: Freitas, Jhonys M., Ramos, David L.O., Sousa, Raquel M.F., Paixão, Thiago R.L.C., Santana, Mário H.P., Muñoz, Rodrigo A.A., Richter, Eduardo M.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 565
container_issue
container_start_page 557
container_title Sensors and actuators. B, Chemical
container_volume 243
creator Freitas, Jhonys M.
Ramos, David L.O.
Sousa, Raquel M.F.
Paixão, Thiago R.L.C.
Santana, Mário H.P.
Muñoz, Rodrigo A.A.
Richter, Eduardo M.
description [Display omitted] •The electrochemical oxidation of cocaine in acid media is proposed for the first time.•Excellent selectivity for cocaine quantification.•Two methods for fast screening of common adulterants in cocaine seized samples.•Minimal sample manipulation (dissolution in electrolyte). A simple and robust batch-injection analysis system with square-wave voltammetric (BIA-SWV) detection is proposed for the determination of cocaine and screening of the most common adulterants (benzocaine, caffeine, lidocaine, phenacetin, paracetamol, and procaine) in seized cocaine samples. The sample only requires a dissolution step in electrolyte (0.1molL−1H2SO4) prior injection into the BIA cell. SWV scanning is performed after injection of the sample plug and cocaine and adulterants are electrochemically oxidized on a boron-doped diamond electrode (BDDE), resulting in a unique voltammetric profile. The use of BDDE was essential to achieve, for the first time, the electrochemical oxidation of cocaine in an acid medium. Using the optimized experimental conditions, a linear response was found for cocaine concentrations ranging from 6 to 30mgL−1, with a detection limit of 0.27mgL−1 (0.89μmolL−1). The accuracy of the proposed method was estimated by comparing the results obtained for seized cocaine samples by GC-FID and with the addition and recovery protocol. Furthermore, BIA with multiple pulse amperometric (MPA) detection is also proposed as a promising protocol for faster screening of seized cocaine samples.
doi_str_mv 10.1016/j.snb.2016.12.024
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2098784405</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0925400516319906</els_id><sourcerecordid>2098784405</sourcerecordid><originalsourceid>FETCH-LOGICAL-c325t-914ec7cdc66cbf0365a89078e44519bd2ff498c21d714c39e3cd612eec70f5c93</originalsourceid><addsrcrecordid>eNp9kE1rHDEMhk1ooNskP6A3Q84zlT2eL3IKIU0LC720Z-OV5ayXGXvWni1Nf328bM89SaD3kcTD2GcBtQDRfTnUOexqWdpayBqkumIbMfRN1UDff2AbGGVbKYD2I_uU8wEAVNPBhv155EtMq9lNxGkiXFPEPc0ezcRnWvfRchcTx4jGB-LHkwmrd2W8-hi4CZYns3jLMyai4MMrj66k5_k8tadppVSIzH3gmfxfKkkzLxPlW3btzJTp7l-9Yb--Pv98-lZtf7x8f3rcVtjIdq1GoQh7tNh1uHPQdK0ZRugHUqoV485K59Q4oBS2FwqbkRq0nZBUIHAtjs0Nu7_sXVI8niiv-hBPKZSTWsI49INS0JaUuKQwxZwTOb0kP5v0pgXos2B90EWwPgvWQuoiuDAPF4bK-789JZ3RU0CyPhWR2kb_H_od7F-FvA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2098784405</pqid></control><display><type>article</type><title>A portable electrochemical method for cocaine quantification and rapid screening of common adulterants in seized samples</title><source>Elsevier ScienceDirect Journals</source><creator>Freitas, Jhonys M. ; Ramos, David L.O. ; Sousa, Raquel M.F. ; Paixão, Thiago R.L.C. ; Santana, Mário H.P. ; Muñoz, Rodrigo A.A. ; Richter, Eduardo M.</creator><creatorcontrib>Freitas, Jhonys M. ; Ramos, David L.O. ; Sousa, Raquel M.F. ; Paixão, Thiago R.L.C. ; Santana, Mário H.P. ; Muñoz, Rodrigo A.A. ; Richter, Eduardo M.</creatorcontrib><description>[Display omitted] •The electrochemical oxidation of cocaine in acid media is proposed for the first time.•Excellent selectivity for cocaine quantification.•Two methods for fast screening of common adulterants in cocaine seized samples.•Minimal sample manipulation (dissolution in electrolyte). A simple and robust batch-injection analysis system with square-wave voltammetric (BIA-SWV) detection is proposed for the determination of cocaine and screening of the most common adulterants (benzocaine, caffeine, lidocaine, phenacetin, paracetamol, and procaine) in seized cocaine samples. The sample only requires a dissolution step in electrolyte (0.1molL−1H2SO4) prior injection into the BIA cell. SWV scanning is performed after injection of the sample plug and cocaine and adulterants are electrochemically oxidized on a boron-doped diamond electrode (BDDE), resulting in a unique voltammetric profile. The use of BDDE was essential to achieve, for the first time, the electrochemical oxidation of cocaine in an acid medium. Using the optimized experimental conditions, a linear response was found for cocaine concentrations ranging from 6 to 30mgL−1, with a detection limit of 0.27mgL−1 (0.89μmolL−1). The accuracy of the proposed method was estimated by comparing the results obtained for seized cocaine samples by GC-FID and with the addition and recovery protocol. Furthermore, BIA with multiple pulse amperometric (MPA) detection is also proposed as a promising protocol for faster screening of seized cocaine samples.</description><identifier>ISSN: 0925-4005</identifier><identifier>EISSN: 1873-3077</identifier><identifier>DOI: 10.1016/j.snb.2016.12.024</identifier><language>eng</language><publisher>Lausanne: Elsevier B.V</publisher><subject>Acetanilide ; Adulterants ; Batch injection analysis ; Boron ; Caffeine ; Cocaine ; Diamonds ; Electrical measurement ; Electrochemical oxidation ; Oxidation ; Portable system ; Screening ; Seized cocaine ; Seizing ; Simultaneous analysis ; Sulfuric acid ; Voltammetry</subject><ispartof>Sensors and actuators. B, Chemical, 2017-05, Vol.243, p.557-565</ispartof><rights>2016 Elsevier B.V.</rights><rights>Copyright Elsevier Science Ltd. May 2017</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c325t-914ec7cdc66cbf0365a89078e44519bd2ff498c21d714c39e3cd612eec70f5c93</citedby><cites>FETCH-LOGICAL-c325t-914ec7cdc66cbf0365a89078e44519bd2ff498c21d714c39e3cd612eec70f5c93</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.snb.2016.12.024$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,777,781,3537,27905,27906,45976</link.rule.ids></links><search><creatorcontrib>Freitas, Jhonys M.</creatorcontrib><creatorcontrib>Ramos, David L.O.</creatorcontrib><creatorcontrib>Sousa, Raquel M.F.</creatorcontrib><creatorcontrib>Paixão, Thiago R.L.C.</creatorcontrib><creatorcontrib>Santana, Mário H.P.</creatorcontrib><creatorcontrib>Muñoz, Rodrigo A.A.</creatorcontrib><creatorcontrib>Richter, Eduardo M.</creatorcontrib><title>A portable electrochemical method for cocaine quantification and rapid screening of common adulterants in seized samples</title><title>Sensors and actuators. B, Chemical</title><description>[Display omitted] •The electrochemical oxidation of cocaine in acid media is proposed for the first time.•Excellent selectivity for cocaine quantification.•Two methods for fast screening of common adulterants in cocaine seized samples.•Minimal sample manipulation (dissolution in electrolyte). A simple and robust batch-injection analysis system with square-wave voltammetric (BIA-SWV) detection is proposed for the determination of cocaine and screening of the most common adulterants (benzocaine, caffeine, lidocaine, phenacetin, paracetamol, and procaine) in seized cocaine samples. The sample only requires a dissolution step in electrolyte (0.1molL−1H2SO4) prior injection into the BIA cell. SWV scanning is performed after injection of the sample plug and cocaine and adulterants are electrochemically oxidized on a boron-doped diamond electrode (BDDE), resulting in a unique voltammetric profile. The use of BDDE was essential to achieve, for the first time, the electrochemical oxidation of cocaine in an acid medium. Using the optimized experimental conditions, a linear response was found for cocaine concentrations ranging from 6 to 30mgL−1, with a detection limit of 0.27mgL−1 (0.89μmolL−1). The accuracy of the proposed method was estimated by comparing the results obtained for seized cocaine samples by GC-FID and with the addition and recovery protocol. Furthermore, BIA with multiple pulse amperometric (MPA) detection is also proposed as a promising protocol for faster screening of seized cocaine samples.</description><subject>Acetanilide</subject><subject>Adulterants</subject><subject>Batch injection analysis</subject><subject>Boron</subject><subject>Caffeine</subject><subject>Cocaine</subject><subject>Diamonds</subject><subject>Electrical measurement</subject><subject>Electrochemical oxidation</subject><subject>Oxidation</subject><subject>Portable system</subject><subject>Screening</subject><subject>Seized cocaine</subject><subject>Seizing</subject><subject>Simultaneous analysis</subject><subject>Sulfuric acid</subject><subject>Voltammetry</subject><issn>0925-4005</issn><issn>1873-3077</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><recordid>eNp9kE1rHDEMhk1ooNskP6A3Q84zlT2eL3IKIU0LC720Z-OV5ayXGXvWni1Nf328bM89SaD3kcTD2GcBtQDRfTnUOexqWdpayBqkumIbMfRN1UDff2AbGGVbKYD2I_uU8wEAVNPBhv155EtMq9lNxGkiXFPEPc0ezcRnWvfRchcTx4jGB-LHkwmrd2W8-hi4CZYns3jLMyai4MMrj66k5_k8tadppVSIzH3gmfxfKkkzLxPlW3btzJTp7l-9Yb--Pv98-lZtf7x8f3rcVtjIdq1GoQh7tNh1uHPQdK0ZRugHUqoV485K59Q4oBS2FwqbkRq0nZBUIHAtjs0Nu7_sXVI8niiv-hBPKZSTWsI49INS0JaUuKQwxZwTOb0kP5v0pgXos2B90EWwPgvWQuoiuDAPF4bK-789JZ3RU0CyPhWR2kb_H_od7F-FvA</recordid><startdate>201705</startdate><enddate>201705</enddate><creator>Freitas, Jhonys M.</creator><creator>Ramos, David L.O.</creator><creator>Sousa, Raquel M.F.</creator><creator>Paixão, Thiago R.L.C.</creator><creator>Santana, Mário H.P.</creator><creator>Muñoz, Rodrigo A.A.</creator><creator>Richter, Eduardo M.</creator><general>Elsevier B.V</general><general>Elsevier Science Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>7SR</scope><scope>7TB</scope><scope>7U5</scope><scope>8BQ</scope><scope>8FD</scope><scope>FR3</scope><scope>JG9</scope><scope>L7M</scope></search><sort><creationdate>201705</creationdate><title>A portable electrochemical method for cocaine quantification and rapid screening of common adulterants in seized samples</title><author>Freitas, Jhonys M. ; Ramos, David L.O. ; Sousa, Raquel M.F. ; Paixão, Thiago R.L.C. ; Santana, Mário H.P. ; Muñoz, Rodrigo A.A. ; Richter, Eduardo M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c325t-914ec7cdc66cbf0365a89078e44519bd2ff498c21d714c39e3cd612eec70f5c93</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Acetanilide</topic><topic>Adulterants</topic><topic>Batch injection analysis</topic><topic>Boron</topic><topic>Caffeine</topic><topic>Cocaine</topic><topic>Diamonds</topic><topic>Electrical measurement</topic><topic>Electrochemical oxidation</topic><topic>Oxidation</topic><topic>Portable system</topic><topic>Screening</topic><topic>Seized cocaine</topic><topic>Seizing</topic><topic>Simultaneous analysis</topic><topic>Sulfuric acid</topic><topic>Voltammetry</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Freitas, Jhonys M.</creatorcontrib><creatorcontrib>Ramos, David L.O.</creatorcontrib><creatorcontrib>Sousa, Raquel M.F.</creatorcontrib><creatorcontrib>Paixão, Thiago R.L.C.</creatorcontrib><creatorcontrib>Santana, Mário H.P.</creatorcontrib><creatorcontrib>Muñoz, Rodrigo A.A.</creatorcontrib><creatorcontrib>Richter, Eduardo M.</creatorcontrib><collection>CrossRef</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Materials Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Sensors and actuators. B, Chemical</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Freitas, Jhonys M.</au><au>Ramos, David L.O.</au><au>Sousa, Raquel M.F.</au><au>Paixão, Thiago R.L.C.</au><au>Santana, Mário H.P.</au><au>Muñoz, Rodrigo A.A.</au><au>Richter, Eduardo M.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A portable electrochemical method for cocaine quantification and rapid screening of common adulterants in seized samples</atitle><jtitle>Sensors and actuators. B, Chemical</jtitle><date>2017-05</date><risdate>2017</risdate><volume>243</volume><spage>557</spage><epage>565</epage><pages>557-565</pages><issn>0925-4005</issn><eissn>1873-3077</eissn><abstract>[Display omitted] •The electrochemical oxidation of cocaine in acid media is proposed for the first time.•Excellent selectivity for cocaine quantification.•Two methods for fast screening of common adulterants in cocaine seized samples.•Minimal sample manipulation (dissolution in electrolyte). A simple and robust batch-injection analysis system with square-wave voltammetric (BIA-SWV) detection is proposed for the determination of cocaine and screening of the most common adulterants (benzocaine, caffeine, lidocaine, phenacetin, paracetamol, and procaine) in seized cocaine samples. The sample only requires a dissolution step in electrolyte (0.1molL−1H2SO4) prior injection into the BIA cell. SWV scanning is performed after injection of the sample plug and cocaine and adulterants are electrochemically oxidized on a boron-doped diamond electrode (BDDE), resulting in a unique voltammetric profile. The use of BDDE was essential to achieve, for the first time, the electrochemical oxidation of cocaine in an acid medium. Using the optimized experimental conditions, a linear response was found for cocaine concentrations ranging from 6 to 30mgL−1, with a detection limit of 0.27mgL−1 (0.89μmolL−1). The accuracy of the proposed method was estimated by comparing the results obtained for seized cocaine samples by GC-FID and with the addition and recovery protocol. Furthermore, BIA with multiple pulse amperometric (MPA) detection is also proposed as a promising protocol for faster screening of seized cocaine samples.</abstract><cop>Lausanne</cop><pub>Elsevier B.V</pub><doi>10.1016/j.snb.2016.12.024</doi><tpages>9</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0925-4005
ispartof Sensors and actuators. B, Chemical, 2017-05, Vol.243, p.557-565
issn 0925-4005
1873-3077
language eng
recordid cdi_proquest_journals_2098784405
source Elsevier ScienceDirect Journals
subjects Acetanilide
Adulterants
Batch injection analysis
Boron
Caffeine
Cocaine
Diamonds
Electrical measurement
Electrochemical oxidation
Oxidation
Portable system
Screening
Seized cocaine
Seizing
Simultaneous analysis
Sulfuric acid
Voltammetry
title A portable electrochemical method for cocaine quantification and rapid screening of common adulterants in seized samples
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-19T09%3A13%3A52IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20portable%20electrochemical%20method%20for%20cocaine%20quantification%20and%20rapid%20screening%20of%20common%20adulterants%20in%20seized%20samples&rft.jtitle=Sensors%20and%20actuators.%20B,%20Chemical&rft.au=Freitas,%20Jhonys%20M.&rft.date=2017-05&rft.volume=243&rft.spage=557&rft.epage=565&rft.pages=557-565&rft.issn=0925-4005&rft.eissn=1873-3077&rft_id=info:doi/10.1016/j.snb.2016.12.024&rft_dat=%3Cproquest_cross%3E2098784405%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2098784405&rft_id=info:pmid/&rft_els_id=S0925400516319906&rfr_iscdi=true