Prototype studies for a forward EM calorimeter in ALICE

A forward electromagnetic calorimeter (FoCal) based on SiW technology is being considered as a possible upgrade to the ALICE detector. This device should in particular feature an extremely high granularity allowing gamma/pi0 discrimination out to very high momenta. The main option considered for the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:arXiv.org 2013-08
Hauptverfasser: Peitzmann, T, the ALICE FoCal collaboration
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page
container_title arXiv.org
container_volume
creator Peitzmann, T
the ALICE FoCal collaboration
description A forward electromagnetic calorimeter (FoCal) based on SiW technology is being considered as a possible upgrade to the ALICE detector. This device should in particular feature an extremely high granularity allowing gamma/pi0 discrimination out to very high momenta. The main option considered for the high granularity layers is the use of CMOS pixel sensors. We will discuss the motivation and design principles of the proposed calorimeter and will then focus on the experience gained with a full CMOS-pixel calorimeter prototype. Preliminary results of this device show very good capabilities for shower profile measurements, and reasonable results for linearity and resolution, which are limited by the currently incomplete calibration.
format Article
fullrecord <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_journals_2086107254</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2086107254</sourcerecordid><originalsourceid>FETCH-proquest_journals_20861072543</originalsourceid><addsrcrecordid>eNpjYuA0MjY21LUwMTLiYOAtLs4yMDAwMjM3MjU15mQwDyjKL8kvqSxIVSguKU3JTC1WSMsvUkgEkeWJRSkKrr4KyYk5-UWZuaklqUUKmXkKjj6ezq48DKxpiTnFqbxQmptB2c01xNlDt6Aov7A0tbgkPiu_tCgPKBVvZGBhZmgAtM_EmDhVAMAUNNQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2086107254</pqid></control><display><type>article</type><title>Prototype studies for a forward EM calorimeter in ALICE</title><source>Free E- Journals</source><creator>Peitzmann, T ; the ALICE FoCal collaboration</creator><creatorcontrib>Peitzmann, T ; the ALICE FoCal collaboration</creatorcontrib><description>A forward electromagnetic calorimeter (FoCal) based on SiW technology is being considered as a possible upgrade to the ALICE detector. This device should in particular feature an extremely high granularity allowing gamma/pi0 discrimination out to very high momenta. The main option considered for the high granularity layers is the use of CMOS pixel sensors. We will discuss the motivation and design principles of the proposed calorimeter and will then focus on the experience gained with a full CMOS-pixel calorimeter prototype. Preliminary results of this device show very good capabilities for shower profile measurements, and reasonable results for linearity and resolution, which are limited by the currently incomplete calibration.</description><identifier>EISSN: 2331-8422</identifier><language>eng</language><publisher>Ithaca: Cornell University Library, arXiv.org</publisher><subject>CMOS ; Linearity ; Pixels</subject><ispartof>arXiv.org, 2013-08</ispartof><rights>2013. This work is published under http://arxiv.org/licenses/nonexclusive-distrib/1.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>777,781</link.rule.ids></links><search><creatorcontrib>Peitzmann, T</creatorcontrib><creatorcontrib>the ALICE FoCal collaboration</creatorcontrib><title>Prototype studies for a forward EM calorimeter in ALICE</title><title>arXiv.org</title><description>A forward electromagnetic calorimeter (FoCal) based on SiW technology is being considered as a possible upgrade to the ALICE detector. This device should in particular feature an extremely high granularity allowing gamma/pi0 discrimination out to very high momenta. The main option considered for the high granularity layers is the use of CMOS pixel sensors. We will discuss the motivation and design principles of the proposed calorimeter and will then focus on the experience gained with a full CMOS-pixel calorimeter prototype. Preliminary results of this device show very good capabilities for shower profile measurements, and reasonable results for linearity and resolution, which are limited by the currently incomplete calibration.</description><subject>CMOS</subject><subject>Linearity</subject><subject>Pixels</subject><issn>2331-8422</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><recordid>eNpjYuA0MjY21LUwMTLiYOAtLs4yMDAwMjM3MjU15mQwDyjKL8kvqSxIVSguKU3JTC1WSMsvUkgEkeWJRSkKrr4KyYk5-UWZuaklqUUKmXkKjj6ezq48DKxpiTnFqbxQmptB2c01xNlDt6Aov7A0tbgkPiu_tCgPKBVvZGBhZmgAtM_EmDhVAMAUNNQ</recordid><startdate>20130812</startdate><enddate>20130812</enddate><creator>Peitzmann, T</creator><creator>the ALICE FoCal collaboration</creator><general>Cornell University Library, arXiv.org</general><scope>8FE</scope><scope>8FG</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>HCIFZ</scope><scope>L6V</scope><scope>M7S</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PTHSS</scope></search><sort><creationdate>20130812</creationdate><title>Prototype studies for a forward EM calorimeter in ALICE</title><author>Peitzmann, T ; the ALICE FoCal collaboration</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_journals_20861072543</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><topic>CMOS</topic><topic>Linearity</topic><topic>Pixels</topic><toplevel>online_resources</toplevel><creatorcontrib>Peitzmann, T</creatorcontrib><creatorcontrib>the ALICE FoCal collaboration</creatorcontrib><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Materials Science &amp; Engineering Collection</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Engineering Collection</collection><collection>Engineering Database</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Engineering Collection</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Peitzmann, T</au><au>the ALICE FoCal collaboration</au><format>book</format><genre>document</genre><ristype>GEN</ristype><atitle>Prototype studies for a forward EM calorimeter in ALICE</atitle><jtitle>arXiv.org</jtitle><date>2013-08-12</date><risdate>2013</risdate><eissn>2331-8422</eissn><abstract>A forward electromagnetic calorimeter (FoCal) based on SiW technology is being considered as a possible upgrade to the ALICE detector. This device should in particular feature an extremely high granularity allowing gamma/pi0 discrimination out to very high momenta. The main option considered for the high granularity layers is the use of CMOS pixel sensors. We will discuss the motivation and design principles of the proposed calorimeter and will then focus on the experience gained with a full CMOS-pixel calorimeter prototype. Preliminary results of this device show very good capabilities for shower profile measurements, and reasonable results for linearity and resolution, which are limited by the currently incomplete calibration.</abstract><cop>Ithaca</cop><pub>Cornell University Library, arXiv.org</pub><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier EISSN: 2331-8422
ispartof arXiv.org, 2013-08
issn 2331-8422
language eng
recordid cdi_proquest_journals_2086107254
source Free E- Journals
subjects CMOS
Linearity
Pixels
title Prototype studies for a forward EM calorimeter in ALICE
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-19T08%3A53%3A47IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=document&rft.atitle=Prototype%20studies%20for%20a%20forward%20EM%20calorimeter%20in%20ALICE&rft.jtitle=arXiv.org&rft.au=Peitzmann,%20T&rft.date=2013-08-12&rft.eissn=2331-8422&rft_id=info:doi/&rft_dat=%3Cproquest%3E2086107254%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2086107254&rft_id=info:pmid/&rfr_iscdi=true