A multi-spectral band stellar photo-polarimeter

We designed and built a new astronomical photo-polarimeter that can measure linear polarization simultaneously in three spectral bands. It has a Calcite beamdisplacement prism as the analyzer. The ordinary and extra-ordinary emerging beams in each spectral bands are quasi-simultaneously detected by...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:arXiv.org 2015-05
Hauptverfasser: Srinivasulu, G, Raveendran, A V, Muneer, S, Mekkaden, M V, Jayavel, N, Somashekar, M R, Sagayanathan, K, Ramamoorthy, S, Rosario, M J, Jayakumar, K
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page
container_title arXiv.org
container_volume
creator Srinivasulu, G
Raveendran, A V
Muneer, S
Mekkaden, M V
Jayavel, N
Somashekar, M R
Sagayanathan, K
Ramamoorthy, S
Rosario, M J
Jayakumar, K
description We designed and built a new astronomical photo-polarimeter that can measure linear polarization simultaneously in three spectral bands. It has a Calcite beamdisplacement prism as the analyzer. The ordinary and extra-ordinary emerging beams in each spectral bands are quasi-simultaneously detected by the same photomultiplier by using a high speed rotating chopper. A rotating superachromatic Pancharatnam halfwave plate is used to modulate the light incident on the analyzer. The spectral bands are isolated using appropriate dichroic and glass filters. We show that the reduction of 50% in the efficiency of the polarimeter because of the fact that the intensities of the two beams are measured alternately is partly compensated by the reduced time to be spent on the observation of the sky background. The use of a beam-displacement prism as the analyzer completely removes the polarization of background skylight, which is a major source of error during moonlit nights, especially, in the case of faint stars. The field trials that were carried out by observing several polarized and unpolarized stars show the performance of the polarimeter to be satisfactory.
format Article
fullrecord <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_journals_2082077978</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2082077978</sourcerecordid><originalsourceid>FETCH-proquest_journals_20820779783</originalsourceid><addsrcrecordid>eNqNikEKwjAQAIMgWLR_CHgOxo018Sii-ADvJeqKLWkTs5v_24MP8DQDMzNRgTFb5XYAC1ET9Vpr2FtoGlOJzVEOJXCnKOGDsw_y7senJMYQfJbpHTmqFCfvBmTMKzF_-UBY_7gU68v5drqqlOOnIHHbx5LHKbWgHWhrD9aZ_64vSVozFg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2082077978</pqid></control><display><type>article</type><title>A multi-spectral band stellar photo-polarimeter</title><source>Free E- Journals</source><creator>Srinivasulu, G ; Raveendran, A V ; Muneer, S ; Mekkaden, M V ; Jayavel, N ; Somashekar, M R ; Sagayanathan, K ; Ramamoorthy, S ; Rosario, M J ; Jayakumar, K</creator><creatorcontrib>Srinivasulu, G ; Raveendran, A V ; Muneer, S ; Mekkaden, M V ; Jayavel, N ; Somashekar, M R ; Sagayanathan, K ; Ramamoorthy, S ; Rosario, M J ; Jayakumar, K</creatorcontrib><description>We designed and built a new astronomical photo-polarimeter that can measure linear polarization simultaneously in three spectral bands. It has a Calcite beamdisplacement prism as the analyzer. The ordinary and extra-ordinary emerging beams in each spectral bands are quasi-simultaneously detected by the same photomultiplier by using a high speed rotating chopper. A rotating superachromatic Pancharatnam halfwave plate is used to modulate the light incident on the analyzer. The spectral bands are isolated using appropriate dichroic and glass filters. We show that the reduction of 50% in the efficiency of the polarimeter because of the fact that the intensities of the two beams are measured alternately is partly compensated by the reduced time to be spent on the observation of the sky background. The use of a beam-displacement prism as the analyzer completely removes the polarization of background skylight, which is a major source of error during moonlit nights, especially, in the case of faint stars. The field trials that were carried out by observing several polarized and unpolarized stars show the performance of the polarimeter to be satisfactory.</description><identifier>EISSN: 2331-8422</identifier><language>eng</language><publisher>Ithaca: Cornell University Library, arXiv.org</publisher><subject>Band spectra ; Calcite ; Celestial bodies ; Linear polarization ; Photomultiplier tubes ; Photopolarimeters ; Rotation ; Spacecraft ; Spectral bands</subject><ispartof>arXiv.org, 2015-05</ispartof><rights>2015. This work is published under http://arxiv.org/licenses/nonexclusive-distrib/1.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>780,784</link.rule.ids></links><search><creatorcontrib>Srinivasulu, G</creatorcontrib><creatorcontrib>Raveendran, A V</creatorcontrib><creatorcontrib>Muneer, S</creatorcontrib><creatorcontrib>Mekkaden, M V</creatorcontrib><creatorcontrib>Jayavel, N</creatorcontrib><creatorcontrib>Somashekar, M R</creatorcontrib><creatorcontrib>Sagayanathan, K</creatorcontrib><creatorcontrib>Ramamoorthy, S</creatorcontrib><creatorcontrib>Rosario, M J</creatorcontrib><creatorcontrib>Jayakumar, K</creatorcontrib><title>A multi-spectral band stellar photo-polarimeter</title><title>arXiv.org</title><description>We designed and built a new astronomical photo-polarimeter that can measure linear polarization simultaneously in three spectral bands. It has a Calcite beamdisplacement prism as the analyzer. The ordinary and extra-ordinary emerging beams in each spectral bands are quasi-simultaneously detected by the same photomultiplier by using a high speed rotating chopper. A rotating superachromatic Pancharatnam halfwave plate is used to modulate the light incident on the analyzer. The spectral bands are isolated using appropriate dichroic and glass filters. We show that the reduction of 50% in the efficiency of the polarimeter because of the fact that the intensities of the two beams are measured alternately is partly compensated by the reduced time to be spent on the observation of the sky background. The use of a beam-displacement prism as the analyzer completely removes the polarization of background skylight, which is a major source of error during moonlit nights, especially, in the case of faint stars. The field trials that were carried out by observing several polarized and unpolarized stars show the performance of the polarimeter to be satisfactory.</description><subject>Band spectra</subject><subject>Calcite</subject><subject>Celestial bodies</subject><subject>Linear polarization</subject><subject>Photomultiplier tubes</subject><subject>Photopolarimeters</subject><subject>Rotation</subject><subject>Spacecraft</subject><subject>Spectral bands</subject><issn>2331-8422</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><recordid>eNqNikEKwjAQAIMgWLR_CHgOxo018Sii-ADvJeqKLWkTs5v_24MP8DQDMzNRgTFb5XYAC1ET9Vpr2FtoGlOJzVEOJXCnKOGDsw_y7senJMYQfJbpHTmqFCfvBmTMKzF_-UBY_7gU68v5drqqlOOnIHHbx5LHKbWgHWhrD9aZ_64vSVozFg</recordid><startdate>20150516</startdate><enddate>20150516</enddate><creator>Srinivasulu, G</creator><creator>Raveendran, A V</creator><creator>Muneer, S</creator><creator>Mekkaden, M V</creator><creator>Jayavel, N</creator><creator>Somashekar, M R</creator><creator>Sagayanathan, K</creator><creator>Ramamoorthy, S</creator><creator>Rosario, M J</creator><creator>Jayakumar, K</creator><general>Cornell University Library, arXiv.org</general><scope>8FE</scope><scope>8FG</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>HCIFZ</scope><scope>L6V</scope><scope>M7S</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PTHSS</scope></search><sort><creationdate>20150516</creationdate><title>A multi-spectral band stellar photo-polarimeter</title><author>Srinivasulu, G ; Raveendran, A V ; Muneer, S ; Mekkaden, M V ; Jayavel, N ; Somashekar, M R ; Sagayanathan, K ; Ramamoorthy, S ; Rosario, M J ; Jayakumar, K</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_journals_20820779783</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Band spectra</topic><topic>Calcite</topic><topic>Celestial bodies</topic><topic>Linear polarization</topic><topic>Photomultiplier tubes</topic><topic>Photopolarimeters</topic><topic>Rotation</topic><topic>Spacecraft</topic><topic>Spectral bands</topic><toplevel>online_resources</toplevel><creatorcontrib>Srinivasulu, G</creatorcontrib><creatorcontrib>Raveendran, A V</creatorcontrib><creatorcontrib>Muneer, S</creatorcontrib><creatorcontrib>Mekkaden, M V</creatorcontrib><creatorcontrib>Jayavel, N</creatorcontrib><creatorcontrib>Somashekar, M R</creatorcontrib><creatorcontrib>Sagayanathan, K</creatorcontrib><creatorcontrib>Ramamoorthy, S</creatorcontrib><creatorcontrib>Rosario, M J</creatorcontrib><creatorcontrib>Jayakumar, K</creatorcontrib><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Materials Science &amp; Engineering Collection</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Engineering Collection</collection><collection>Engineering Database</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Engineering Collection</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Srinivasulu, G</au><au>Raveendran, A V</au><au>Muneer, S</au><au>Mekkaden, M V</au><au>Jayavel, N</au><au>Somashekar, M R</au><au>Sagayanathan, K</au><au>Ramamoorthy, S</au><au>Rosario, M J</au><au>Jayakumar, K</au><format>book</format><genre>document</genre><ristype>GEN</ristype><atitle>A multi-spectral band stellar photo-polarimeter</atitle><jtitle>arXiv.org</jtitle><date>2015-05-16</date><risdate>2015</risdate><eissn>2331-8422</eissn><abstract>We designed and built a new astronomical photo-polarimeter that can measure linear polarization simultaneously in three spectral bands. It has a Calcite beamdisplacement prism as the analyzer. The ordinary and extra-ordinary emerging beams in each spectral bands are quasi-simultaneously detected by the same photomultiplier by using a high speed rotating chopper. A rotating superachromatic Pancharatnam halfwave plate is used to modulate the light incident on the analyzer. The spectral bands are isolated using appropriate dichroic and glass filters. We show that the reduction of 50% in the efficiency of the polarimeter because of the fact that the intensities of the two beams are measured alternately is partly compensated by the reduced time to be spent on the observation of the sky background. The use of a beam-displacement prism as the analyzer completely removes the polarization of background skylight, which is a major source of error during moonlit nights, especially, in the case of faint stars. The field trials that were carried out by observing several polarized and unpolarized stars show the performance of the polarimeter to be satisfactory.</abstract><cop>Ithaca</cop><pub>Cornell University Library, arXiv.org</pub><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier EISSN: 2331-8422
ispartof arXiv.org, 2015-05
issn 2331-8422
language eng
recordid cdi_proquest_journals_2082077978
source Free E- Journals
subjects Band spectra
Calcite
Celestial bodies
Linear polarization
Photomultiplier tubes
Photopolarimeters
Rotation
Spacecraft
Spectral bands
title A multi-spectral band stellar photo-polarimeter
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-15T00%3A37%3A24IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=document&rft.atitle=A%20multi-spectral%20band%20stellar%20photo-polarimeter&rft.jtitle=arXiv.org&rft.au=Srinivasulu,%20G&rft.date=2015-05-16&rft.eissn=2331-8422&rft_id=info:doi/&rft_dat=%3Cproquest%3E2082077978%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2082077978&rft_id=info:pmid/&rfr_iscdi=true