UbiBreathe: A Ubiquitous non-Invasive WiFi-based Breathing Estimator
Monitoring breathing rates and patterns helps in the diagnosis and potential avoidance of various health problems. Current solutions for respiratory monitoring, however, are usually invasive and/or limited to medical facilities. In this paper, we propose a novel respiratory monitoring system, UbiBre...
Gespeichert in:
Veröffentlicht in: | arXiv.org 2015-05 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | |
container_start_page | |
container_title | arXiv.org |
container_volume | |
creator | Abdelnasser, Heba Harras, Khaled A Youssef, Moustafa |
description | Monitoring breathing rates and patterns helps in the diagnosis and potential avoidance of various health problems. Current solutions for respiratory monitoring, however, are usually invasive and/or limited to medical facilities. In this paper, we propose a novel respiratory monitoring system, UbiBreathe, based on ubiquitous off-the-shelf WiFi-enabled devices. Our experiments show that the received signal strength (RSS) at a WiFi-enabled device held on a person's chest is affected by the breathing process. This effect extends to scenarios when the person is situated on the line-of-sight (LOS) between the access point and the device, even without holding it. UbiBreathe leverages these changes in the WiFi RSS patterns to enable ubiquitous non-invasive respiratory rate estimation, as well as apnea detection. We propose the full architecture and design for UbiBreathe, incorporating various modules that help reliably extract the hidden breathing signal from a noisy WiFi RSS. The system handles various challenges such as noise elimination, interfering humans, sudden user movements, as well as detecting abnormal breathing situations. Our implementation of UbiBreathe using off-the-shelf devices in a wide range of environmental conditions shows that it can estimate different breathing rates with less than 1 breaths per minute (bpm) error. In addition, UbiBreathe can detect apnea with more than 96% accuracy in both the device-on-chest and hands-free scenarios. This highlights its suitability for a new class of anywhere respiratory monitoring. |
format | Article |
fullrecord | <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_journals_2081615460</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2081615460</sourcerecordid><originalsourceid>FETCH-proquest_journals_20816154603</originalsourceid><addsrcrecordid>eNqNiksKwjAUAIMgWLR3CLgOpElTizs_LbpXXJYUo76iic1Len4LegBXwzAzIYmQMmNlLsSMpIgd51wUK6GUTMj-3MLWGx0eZk03dLQ-QnARqXWWHe2gEQZDL1ADazWaK_3eYO-0wgAvHZxfkOlNP9GkP87Jsq5OuwN7e9dHg6HpXPR2TI3gZVZkKi-4_O_6APDEOf8</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2081615460</pqid></control><display><type>article</type><title>UbiBreathe: A Ubiquitous non-Invasive WiFi-based Breathing Estimator</title><source>Free eJournals</source><creator>Abdelnasser, Heba ; Harras, Khaled A ; Youssef, Moustafa</creator><creatorcontrib>Abdelnasser, Heba ; Harras, Khaled A ; Youssef, Moustafa</creatorcontrib><description>Monitoring breathing rates and patterns helps in the diagnosis and potential avoidance of various health problems. Current solutions for respiratory monitoring, however, are usually invasive and/or limited to medical facilities. In this paper, we propose a novel respiratory monitoring system, UbiBreathe, based on ubiquitous off-the-shelf WiFi-enabled devices. Our experiments show that the received signal strength (RSS) at a WiFi-enabled device held on a person's chest is affected by the breathing process. This effect extends to scenarios when the person is situated on the line-of-sight (LOS) between the access point and the device, even without holding it. UbiBreathe leverages these changes in the WiFi RSS patterns to enable ubiquitous non-invasive respiratory rate estimation, as well as apnea detection. We propose the full architecture and design for UbiBreathe, incorporating various modules that help reliably extract the hidden breathing signal from a noisy WiFi RSS. The system handles various challenges such as noise elimination, interfering humans, sudden user movements, as well as detecting abnormal breathing situations. Our implementation of UbiBreathe using off-the-shelf devices in a wide range of environmental conditions shows that it can estimate different breathing rates with less than 1 breaths per minute (bpm) error. In addition, UbiBreathe can detect apnea with more than 96% accuracy in both the device-on-chest and hands-free scenarios. This highlights its suitability for a new class of anywhere respiratory monitoring.</description><identifier>EISSN: 2331-8422</identifier><language>eng</language><publisher>Ithaca: Cornell University Library, arXiv.org</publisher><subject>Breathing ; Chest ; Error detection ; Line of sight ; Respiratory rate ; Signal strength</subject><ispartof>arXiv.org, 2015-05</ispartof><rights>2015. This work is published under http://arxiv.org/licenses/nonexclusive-distrib/1.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>776,780</link.rule.ids></links><search><creatorcontrib>Abdelnasser, Heba</creatorcontrib><creatorcontrib>Harras, Khaled A</creatorcontrib><creatorcontrib>Youssef, Moustafa</creatorcontrib><title>UbiBreathe: A Ubiquitous non-Invasive WiFi-based Breathing Estimator</title><title>arXiv.org</title><description>Monitoring breathing rates and patterns helps in the diagnosis and potential avoidance of various health problems. Current solutions for respiratory monitoring, however, are usually invasive and/or limited to medical facilities. In this paper, we propose a novel respiratory monitoring system, UbiBreathe, based on ubiquitous off-the-shelf WiFi-enabled devices. Our experiments show that the received signal strength (RSS) at a WiFi-enabled device held on a person's chest is affected by the breathing process. This effect extends to scenarios when the person is situated on the line-of-sight (LOS) between the access point and the device, even without holding it. UbiBreathe leverages these changes in the WiFi RSS patterns to enable ubiquitous non-invasive respiratory rate estimation, as well as apnea detection. We propose the full architecture and design for UbiBreathe, incorporating various modules that help reliably extract the hidden breathing signal from a noisy WiFi RSS. The system handles various challenges such as noise elimination, interfering humans, sudden user movements, as well as detecting abnormal breathing situations. Our implementation of UbiBreathe using off-the-shelf devices in a wide range of environmental conditions shows that it can estimate different breathing rates with less than 1 breaths per minute (bpm) error. In addition, UbiBreathe can detect apnea with more than 96% accuracy in both the device-on-chest and hands-free scenarios. This highlights its suitability for a new class of anywhere respiratory monitoring.</description><subject>Breathing</subject><subject>Chest</subject><subject>Error detection</subject><subject>Line of sight</subject><subject>Respiratory rate</subject><subject>Signal strength</subject><issn>2331-8422</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><sourceid>BENPR</sourceid><recordid>eNqNiksKwjAUAIMgWLR3CLgOpElTizs_LbpXXJYUo76iic1Len4LegBXwzAzIYmQMmNlLsSMpIgd51wUK6GUTMj-3MLWGx0eZk03dLQ-QnARqXWWHe2gEQZDL1ADazWaK_3eYO-0wgAvHZxfkOlNP9GkP87Jsq5OuwN7e9dHg6HpXPR2TI3gZVZkKi-4_O_6APDEOf8</recordid><startdate>20150510</startdate><enddate>20150510</enddate><creator>Abdelnasser, Heba</creator><creator>Harras, Khaled A</creator><creator>Youssef, Moustafa</creator><general>Cornell University Library, arXiv.org</general><scope>8FE</scope><scope>8FG</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>HCIFZ</scope><scope>L6V</scope><scope>M7S</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PTHSS</scope></search><sort><creationdate>20150510</creationdate><title>UbiBreathe: A Ubiquitous non-Invasive WiFi-based Breathing Estimator</title><author>Abdelnasser, Heba ; Harras, Khaled A ; Youssef, Moustafa</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_journals_20816154603</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Breathing</topic><topic>Chest</topic><topic>Error detection</topic><topic>Line of sight</topic><topic>Respiratory rate</topic><topic>Signal strength</topic><toplevel>online_resources</toplevel><creatorcontrib>Abdelnasser, Heba</creatorcontrib><creatorcontrib>Harras, Khaled A</creatorcontrib><creatorcontrib>Youssef, Moustafa</creatorcontrib><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Materials Science & Engineering Collection</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Engineering Collection</collection><collection>Engineering Database</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Engineering Collection</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Abdelnasser, Heba</au><au>Harras, Khaled A</au><au>Youssef, Moustafa</au><format>book</format><genre>document</genre><ristype>GEN</ristype><atitle>UbiBreathe: A Ubiquitous non-Invasive WiFi-based Breathing Estimator</atitle><jtitle>arXiv.org</jtitle><date>2015-05-10</date><risdate>2015</risdate><eissn>2331-8422</eissn><abstract>Monitoring breathing rates and patterns helps in the diagnosis and potential avoidance of various health problems. Current solutions for respiratory monitoring, however, are usually invasive and/or limited to medical facilities. In this paper, we propose a novel respiratory monitoring system, UbiBreathe, based on ubiquitous off-the-shelf WiFi-enabled devices. Our experiments show that the received signal strength (RSS) at a WiFi-enabled device held on a person's chest is affected by the breathing process. This effect extends to scenarios when the person is situated on the line-of-sight (LOS) between the access point and the device, even without holding it. UbiBreathe leverages these changes in the WiFi RSS patterns to enable ubiquitous non-invasive respiratory rate estimation, as well as apnea detection. We propose the full architecture and design for UbiBreathe, incorporating various modules that help reliably extract the hidden breathing signal from a noisy WiFi RSS. The system handles various challenges such as noise elimination, interfering humans, sudden user movements, as well as detecting abnormal breathing situations. Our implementation of UbiBreathe using off-the-shelf devices in a wide range of environmental conditions shows that it can estimate different breathing rates with less than 1 breaths per minute (bpm) error. In addition, UbiBreathe can detect apnea with more than 96% accuracy in both the device-on-chest and hands-free scenarios. This highlights its suitability for a new class of anywhere respiratory monitoring.</abstract><cop>Ithaca</cop><pub>Cornell University Library, arXiv.org</pub><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | EISSN: 2331-8422 |
ispartof | arXiv.org, 2015-05 |
issn | 2331-8422 |
language | eng |
recordid | cdi_proquest_journals_2081615460 |
source | Free eJournals |
subjects | Breathing Chest Error detection Line of sight Respiratory rate Signal strength |
title | UbiBreathe: A Ubiquitous non-Invasive WiFi-based Breathing Estimator |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-04T08%3A40%3A16IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=document&rft.atitle=UbiBreathe:%20A%20Ubiquitous%20non-Invasive%20WiFi-based%20Breathing%20Estimator&rft.jtitle=arXiv.org&rft.au=Abdelnasser,%20Heba&rft.date=2015-05-10&rft.eissn=2331-8422&rft_id=info:doi/&rft_dat=%3Cproquest%3E2081615460%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2081615460&rft_id=info:pmid/&rfr_iscdi=true |